Please click here to check who's online and chat with them.

Find Verified Miniature Circuit Breaker Hgb9 63 Suppliers, Manufacturers and Wholesalers

May-23-19
 
Standard: IEC/EN60898-1 GB/T10963.1
Instantaneous trip type: B/C/D
The number of poles: 1P/1P+N/2P/3P/3P+N/4P
Rated short circuit breaking capacity (Icn): 6kA
Rated working current (In): 1-63A
Rated working voltage (Ue): AC 230/400V
Rated operating frequency: 50/60Hz
Rated insulation voltage (Ui): 500V
Rated impulse withstand voltage (Uimp): 4kV
Mechanical/electrical life: 10000/4000 Times
GOLD Member
Jun-17-25

Eaton Kd3350 Series 3 Industrial Circuit Breaker, NEW

$1.44K - $1.56K / Box (FOB)
MOQ: 1  Boxes
Supplier From Doral, United States
 
brand new Eaton KD3350 Series 3 Industrial Circuit Breaker with 3 poles and a rating of 350A at 600V. It is a premium quality product from a reputable brand and is designed for use in industrial automation and motion control applications. The breaker is compatible with the Automate controller platform and is perfect for use in PLC processors
May-23-19
 
Standard: IEC/EN60898-1 GB/T10963.1
Instantaneous trip type: B/C/D
The number of poles: 1P/1P+N/2P/3P/3P+N/4P
Rated short circuit breaking capacity (Icn): 10kA
Rated working current (In): 1-63A
Rated working voltage( Ue): AC 230/400V
Rated operating frequency: 50/60Hz
Rated insulation voltage (Ui): 500V
Rated impulse withstand voltage (Uimp): 4kV
Mechanical/electrical life: 10000/4000 Time
May-23-19
 
Standard: IEC/EN60898-1 GB/T10963.1
Instantaneous trip type: B/C/D
The number of poles: 1P/1P+N/2P/3P/3P+N/4P
Rated short circuit breaking capacity (Icn): 6kA
Rated working current (In): 1-63A
Rated working voltage (Ue): AC 230/400V
Rated operating frequency: 50/60Hz
Rated insulation voltage (Ui): 500V
Rated impulse withstand voltage (Uimp): 4kV
Mechanical/electrical life: 10000/4000 Times
May-23-19
 
Standard: EC/EN60898-1 GB/T10963.1
Instantaneous trip type: B/C/D
The number of poles: 1P/1P+N/2P/3P/3P+N/4P
Rated short circuit breaking capacity (Icn): 4.5/6kA
Rated working current: In 1-63A
Rated working voltage (Ue): AC 230/400V
Rated operating frequency: 50/60Hz
Rated insulation voltage (Ui): 500V
Rated impulse withstand voltage (Uimp): 4kV
Mechanical/electrical life: 10000/4000 Times
3047 Miniature Circuit Breaker Hgb9 63 Suppliers
Short on time? Let Miniature Circuit Breaker Hgb9 63 sellers contact you.
May-23-19
 
Standard: IEC/EN60898-1 GB/T10963.1
Instantaneous trip type: B/C/D
The number of poles: 1P/1P+N/2P/3P/3P+N/4P
Rated short circuit breaking capacity( Icn): 10kA
Rated working current (In): 1-63A
Rated working voltage (Ue): AC 230/400V
Rated operating frequency: 50/60Hz
Rated insulation voltage (Ui): 500V
Rated impulse withstand voltage (Uimp): 4kV
Mechanical/electrical life: 10000/4000 Times
May-23-19
 
Standard: IEC/EN60898-1 GB/T10963.1
Instantaneous trip type: B/C/D
The number of poles: 1P/1P+N/2P/3P/3P+N/4P
Rated short circuit breaking capacity (Icn): 6kA
Rated working current (In): 1-63A
Rated working voltage (Ue) : AC 230/400V
Rated operating frequency: 50/60Hz
Rated insulation voltage (Ui): 500V
Rated impulse withstand voltage (Uimp): 4kV
Mechanical/electrical life: 10000/4000 Times
Jun-27-17
 
Our featured products automatic transfer switch, circuit breaker, contactor, pilot light,relay, SPD, etc. with solid quality and considerable price and could equip them with enclosure.

Circuit Breaker
DZ47 is an automatically operated electrical switch designed to protect an electrical circuit from damage caused by overload or short circuit. Its basic function is to detect a fault condition and, by interrupting continuity, to immediately discontinue electrical flow. When a current is interrupted, the arc must be contained, cooled, and extinguished in a controlled way. So that the gap between the contacts can again withstand the voltage in the circuit.
Electric ratings: 
a. AC: up to 63A, AC230/400V, AC50/60Hz;
b. DC: up to 63A, DC110V/1P, DC125V/2P;
Application: for protection of circuits from over-load and short-circuit; and for infrequent making and breaking of circuits under normal operation conditions, as well;
Standard: IEC/EN 60898.
Mar-08-17
 
Miniature circuit breakers protect installations against overload and short-circuit, warranting reliability and safety for operations. They have two different tripping mechanisms, the delayed thermal tripping mechanism for overload protection and the magnetic tripping mechanism for short circuit protection.
ï?? Extra-wide and complete range of MCBs to cover most applications and markets
ï?? Meeting worldwide standards
ï?? Certificates, documentation, training or background information to support customers due to their daily work
ï?? Space and time saving thanks to frame degree updates

Main features
MCB range offer the possibility to select among different characteristics (B, C, D), configurations (1P, 1P+N, 2P, 3P, 3P+N, 4P), breaking capacities (up to 15 kA) and rated currents (up to 125A).
Compliance to the worldwide standards,
IEC/EN 60898-1
IEC/EN 60947-2
IEC/EN 60947-3
IEC/EN 61009-1
GB10963.1
GB1096.1
GB14048.2
GB14048.3
GB16917.1
Allowing the use for residential, commercial and industrial applications 25 mm2 and 10 mm2 cylinder lift twin terminals for challenging industrial use. Cross Real contact position indication, directly connected to the moving contact, for more comfort and safety
ï?? Environmental
Ambient Air Temperature: Operation -5 ... +55°C Storage -40 ... +70 °C
Resistance to Shock acc. to IEC 60068-2-27: 30g / 2 shocks / 13 ms
Resistance to Vibrations acc. to IEC 60068-2-6: 5g, 20 cycles at 5 ... 150 ... 5 Hz
Environmental Conditions: 28 cycles with 55 °C / 90-96 % and 25 °C / 95-100 %
Technical Standards: IEC/EN 60898-1
Rated Current (In): 6A, 10A,16A, 20A, 25A, 32A, 40A, 50A, 63A, 80A, 125A
Rated Operational Voltage: acc. to IEC 60898-1 230 V AC & 400V AC
Rated Insulation Voltage (Ui): acc. to IEC/EN 60664-1 440 V
Rated Frequency (f): 50 Hz 60 Hz
Rated Ultimate Short-Circuit Breaking Capacity (Icu): (230V AC & 400V AC) 15 kA
Rated Service Short-Circuit Breaking Capacity (Ics): (230V AC & 400V AC) 6 kA
Instantaneous release: Type C: Lighting protection ; Type D: Motor protection
Dec-05-11
 
The series of (MCB) mini circuit breakers are suitable for circuit of AC 50HZ or 60HZ.rated voltage up to 400V,rated current up to 63A,they are mainly used in office,singe-pole lighting,distribution system for overload and short circuit protection. The series of miniature circuit-breakers conform to IEC60898 and GBI0963 standards,and comply with CCC,CE...certificate.



42.5*23.5*34cm
22kg
240pcs.
Sep-30-20

Miniature Circuit Breaker Mcb

$1
MOQ: Not Specified
Supplier From Delhi, New Delhi, India
 
More Information
Brands : Schneider, Siemens, Chint, Havells, Abb, Hager, C&S, L&T, HPL etc
HSN : 85362030
Number of Poles : 1, 2, 3, 4 Poles
Current Rating (Amp) : 0.5 A to 125A
Curve : B Curve, C Curve, D Curve
Frequency Rating : 50/60 Hz
Jan-30-11
Supplier From Lauf-A-D-Pegnitz, Germany
 
Functional design
* Modern design
* User-friendly ergonomics
* Easy-to-understand product designation
* Clearly legible On/Off marking.

Compact construction
* Minimum dimensions - with an installation height of 82.5 mm, one of the smallest miniature circuit breakers on the market
* Maximum saving of space for comfortable wiring.


Easier busbar removal
* Innovative fixing slides for easy removal from a busbar combination
* No laborious moving of the mounted miniature circuit breakers
* "Singlefix" for removal from a bottomfixed busbar
* "Twinfix" for removal from a busbar on both sides.


Perfect compatibility
* Multi-system compatibility of the S, SL and T product ranges, the RCCBs and DIN-rail panel products
* Suitable for bottom busbar installation with previous products
* Use of standard busbars
* Attachments compatible with all product ranges.
May-14-09
 
GSB2 series Micro Circuit Breakers comply with IEC60898-1:

Rated Isolation Voltage: up to AC500V

Rated Voltage: 240V AC for 1P 415V AC for 2P, 3P and 4P

Rated Current of Frame (A): 63A

Rated Current (A): 1A, 3A, 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A

Rated Ultimate Short-circuit Breaking Capacity (KA): 6

Rated Impulse Withstand Voltage or Uimp (KV): 4

Instantaneous Release: C or D

Mechanical Life: 20000 times

Grade of Protection: IP20

Connection Capacity: 1-25MM2

Frequency: 50Hz or 60Hz

Poles: 1, 2, 3 or 4.

Width of single pole: 18mm.
Sep-24-04
 
Pole number: 1,2,3P
Rated voltage: 120/240V
Rated current: 10,15,20,25,30,40,50,60A
Interrupting Capability: 10KA
Standard: US standard
Feb-05-15
Supplier From Vadodara, Gujarat, India
 
Bis approval for isi marking as per latest is/iec 60898:2002 for assured quality and protection
Green product – recyclable, low watt loss, free from hazardous material like cfc and silicon (rohs)
Mcb with patented unique slr (slide latch-release) feature for tool free removal from din rail. It also allows individual mcbs to be removed from bus mounted assembly
Ergonomically designed, with a user friendly lever for effortless switching
To highlight exact switching position, easily recognizable color coded on-off is embedded on the attractive grey lever
VERIFIED
Sep-19-22
 
* 1P, 2P, 3P, 4P
* Rated Current In(A):1~125
* Rated Voltage Ue(V): 230/ 400
* Rated Frenquency(HZ): 50/60
* Rated Short Circuit Capacity Icn (A): 10000
Mar-06-09
 
Mini circuit breaker has novel structure , reliable performance, high breaking capacity, pleasing outlook and small size. Its case and items are adopted by high fireresistant and shockproof plastics, it mainly used in the building office, house and similar building for illuminating at ac 50hz(60 hz), rated voltage below 400v , rated current below 100 a, distribution circuit and equipment overload, short circuit protection .It can also be used for unfrequent switch over of the circuit under normal conditions .This product conforms to the requirement of iec 60898&gb 10963 standards.
Mar-06-09
 
Mini circuit breaker has novel structure , reliable performance, high breaking capacity, pleasing outlook and small size. Its case and items are adopted by high fireresistant and shockproof plastics, it mainly used in the building office, house and similar building for illuminating at ac 50hz(60 hz), rated voltage below 400v , rated current below 100 a, distribution circuit and equipment overload, short circuit protection .It can also be used for unfrequent switch over of the circuit under normal conditions .This product conforms to the requirement of iec 60898&gb 10963 standards.
Mar-06-09
 
Mini circuit breaker has novel structure , reliable performance, high breaking capacity, pleasing outlook and small size. Its case and items are adopted by high fireresistant and shockproof plastics, it mainly used in the building office, house and similar building for illuminating at ac 50hz(60 hz), rated voltage below 400v , rated current below 100 a, distribution circuit and equipment overload, short circuit protection .It can also be used for unfrequent switch over of the circuit under normal conditions .This product conforms to the requirement of iec 60898&gb 10963 standards.
Mar-06-09
 
Mini circuit breaker has novel structure , reliable performance, high breaking capacity, pleasing outlook and small size. Its case and items are adopted by high fireresistant and shockproof plastics, it mainly used in the building office, house and similar building for illuminating at ac 50hz(60 hz), rated voltage below 400v , rated current below 100 a, distribution circuit and equipment overload, short circuit protection .It can also be used for unfrequent switch over of the circuit under normal conditions .This product conforms to the requirement of iec 60898&gb 10963 standards.
3047 Miniature Circuit Breaker Hgb9 63 Suppliers
Short on time? Let Miniature Circuit Breaker Hgb9 63 sellers contact you.
Explore Miniature Circuit Breaker Hgb9 63 related import export discussions