Measuring system It is a portable measuring system with ip67 coverage. These features predetermine Magic xbm to outdoor measuring and working in heavier climatic Conditions. The system enables to measure three values at a time (depending on The type of the smart probe) and gives the possibility to use a submersible probe With ip 68 coverage. Laboratory probes can be connected as well. All types of Smart probes are interchangeable and compatible. The linking interface is a part Of the pda. The time of data recording during the dataloger function Example: when the record interval is 20 minutes, the outdoor xbm can work About 1 month on its own internal energy source. A reserve accumulator can be Supplied for longer lasting or more frequent monitoring. 7 Another version of magic xbm is a bench pda, which can measure up to 4 Values at a time. The pda is placed in a voltage bolster from which up to 4 Sensors can be supplied. Next to the bolster one sensor can be connected directly To the pda. When the pda is not used for measuring, it can be used as a Personal organiser. This version of magic xbm is capable of precise laboratory measurements and Can replace all types of bench and portable measuring instruments
Specifications: Model: YVM-2010CSPC Measuring Range ( X,Y axis ): 200x100mm Accuracy: ( 3+L/200 ) ¦Ìm Dimensions ( L*W*H ): 550,500,680mm Weight ( KG ): 150 Optional Parts: 0.5X , 2X lens Warranty: One Year. Wooden case.
Specifications: Model: YVM-2010VT Measuring Range ( X,Y axis ): 200x100mm Accuracy: ( 3+L/200 ) ¦Ìm Dimensions ( L*W*H ): 550,500,950mm Weight ( KG ): 175 Optional Parts: 0.5X , 2X lens Warranty: One Year. Wooden Case.
HCL2840 precision capacitance and dissipation bridge (2.5kv, can be upgrade to 12kv.). Strong wooden case, Dimensions: 670x500x650 Weight :30kg.
Models • Urocomp 2000 Uroflow + Cystometry • Urocomp 2000E Uroflow + Cystometry + Emg • Urocomp 2000U Uroflow + Cystometry + UPP • Urocomp 2000 EU uroflow + cystometry + EMG + UPP + Video + Gynaecology study. 1 number.
Video measuring system
Antenna measuring system. EMC, EMI, EMI-sight. SAR system. RF communication system.
8''All Infrared Detection Body Temperature Intelligent Fast Face Recognition Android all-in-one machine Suitable for scenic spot,office,hotel,school,shopping mall,community or any other places require auto face recognition.
LDC-X200 Laser Diameter Measurement System Overview The non-contact diameter measuring system, is mainly used in the measurement of the outer diameter of various wire rods, bars, wires and pipes. The system can detect the change of the diameter (outer diameter) of the measured object in real time under the high temperature state. The working principle The diameter measuring system takes the laser scanning method as an example. It adopts the probe imported from Japan, which can achieve an accuracy of plus or minus 2 microns in the range of 0.3 to 30 mm. The acquisition frequency reaches 2000 times/second. The probe uses a self-excited infrared light source, which overcomes the measurement problem in dim environments. It adopts the measurement method of pulse parallel light scanning, and has a strong ability to resist the jitter of the measured object. (As shown in Figure 1) Since the shaking frequency of the measured object is much smaller than the scanning frequency, when the measured object A moves in the shakeable area, the measurement result will be able to ensure its accuracy because the time it blocks the beam does not change. Figure 1: Probe Scanning Radiation Area The detection principle is as follows Figure 2: Working Principle First, the crystal oscillator generates self-excited high-frequency pulses, which are sent to the comparator and the stepping servo motor respectively. The stepping servo motor drives the octahedral prism to rotate at a high speed, and reflects the infrared laser emitted by the laser generator to the convex lens A. It becomes parallel light, and then collects on the photosensitive element C through the convex lens B in the infrared receiving probe. The photosensitive element C converts this signal into a corresponding electrical signal and sends it to the other end of the comparator to compare with the original signal. When there is no object to be measured in the measuring probe, the pulse signal at both ends of the comparator will be the same. Therefore, there is no difference output: when there is an object to be measured in the measuring probe, the photosensitive element C will output no pulse signal during the period of scanning through the object to be measured. Therefore, there will be a difference input for a period of time at both ends of the comparator, which corresponds to the diameter of the measured object. By calculating the oscillation period of the pulse and the length of the time slice without pulse, the diameter of the measured object can be known.
Specification - Lamp Wavelength Range: 250nm-2500nm - Measuring Wavelength Rane: 300nm-1100nm, 300nm-1800nm, 300nm-2500nm - Un-Repeatability:
M(Magneto)-EL(Electroluminescence) Measurement System (CTS-104): Applications Measurement of luminescence intensity change according to the influence of magnetic field of organic materials (MEL) Specification Magnetic field range: 1mT to 270mT Input Range: (Voltage/Current) 20V / 1A Key components Permanent Magnet, Source Meter, Photo Detector, Multimeter, Automatic Transfer Device, Element fixing device, Fiber Optic Measurement/Analysis Software, Operating PC (Option) Temperature Control Element Fixing Device, Low Temperature Cryostat
Transient Electroluminescence Measurement System(CTS-103): Applied Areas & Characteristics - OLED Device : TEG, CELL(Panel) - QLED Device - uLED Device - T-EL(Transient Electroluminescence) : Rising/Falling Characteristic Measurement, Electron Mobility - Data Analysis : Slop Calculation, Normalization, Turn-on Time(T0) Calculation, Raise/Falling Sections, EL Reserve Dataprocessing Applications :Measurement and analysis of electroluminescence response characteristics Specification : Contact separately Key components : Pulse signal generator, Oscilloscope, Photodetector, Element fixing device, Measurement/analysis software, Facility operating PC (Option) Optical system, Temperature control device
M(Magneto)-EL(Electroluminescence) Measurement System (CTS-104): Applications Measurement of luminescence intensity change according to the influence of magnetic field of organic materials (MEL) Specification Magnetic field range: 1mT to 270mT Input Range: (Voltage/Current) 20V / 1A Key components Permanent Magnet, Source Meter, Photo Detector, Multimeter, Automatic Transfer Device, Element fixing device, Fiber Optic Measurement/Analysis Software, Operating PC (Option) Temperature Control Element Fixing Device, Low Temperature Cryostat
--General Type 1.Measure item: Ratio Error and Phase Error of the CT& PT 2.Complying with ANSI / IEEE C57.13 Standard or IEC 60044-1 Standard (According to the User`s requirements) 3.Testing system included: ï?·HES Series Control Bench ï?·HES-1C Series Transformer Tester ï?·FY Series Current Transformer Burden ï?·HLS Series Standard Current Transformer (with Current Source) ï?·FY Series Voltage Transformer Burden ï?·HJS Seires Standard Voltage Transformer (with Voltage Source) ï?·High Current Testing Cables ï?·Secondary Testing Cables of the CT&VT
7ich screen 4gb capacity core 200w piexl camera
OLED Mobility(TOF) Measurement System(CTS-102) Characteristics & Strengths -Automated TOF Data Measurement System -Owing to the application of ND-Yag Laser, it could be Semi-Permanently used without Consumables. -With the improvement of noise characteristic, it is possible to measure the TOF Characteristic Signal in Low-Voltage Field Bias. -Convenient Measurement of GUI & Automated Sequence Function -Zero-Field Mobility Analysis Function Applications :Measurement and Analysis of Electronic Material Charge Mobility Specification : Contact separately Key components :Laser, oscilloscope, Source meter, Optical system, Element fixing device Measurement / Analysis software, Facility operation PC Temperature control device (option)
Stage Introduction: FS-G series are used to measure optical characteristics of monitor from 17 to 65 inches, TV BLU, light-emitting panel, diffuser, brightness enhancement film, CCFL and LED Light bar Module. Hardware Motion Characteristics: Measured BLU is placed flat on the object-loading platform and is motionless when being measured. Optical measurement instrument is driven by motor and can move along X axis and Y axis linearly in two dimensions. It's possible to manually adjust measurement distance between optical instrument and measured BLU surface. Object-loading platform can extend out/withdraw to place big sized measured BLU. FS-G series' standard accessories are dark room with dark light-shielding cloth and options are sealed metal dark room with dark baking varnish. FS-G3 Series Stage Introduction: As CCFL light source's BLU needs to be warmed up for tens of minutes before measurement and begins measurement after luminance is steady, warm up process takes stage's most of time. FS-G3 series optical measurement stage, produced by FSTAR can warm up and measure multi plates of BLU at the same time so that stage and optical instrument's usage efficiency is greatly improved.
Every Component of Measurement System Specifications: 1. Programmable Power Supplier: Voltage and current output are controlled by measurement software. Voltage range is 0~300V. Voltage output precision is 0.01V; current range is 0~2A. Current output precision is 1mA. Max output power is 600W. 2. Optical Measurement Instrument SR-3AR Please refer SR-3AR specification for specific specification. 3. Optical Measurement Stage Hardware Specification: Max placed Light bar number: 12 bars. Single light bar max measurement length: 800mm. X axis automatic motion distance: 800mm. Precision: 0.01mm Y axis automatic motion distance: 400mm. Precision: 0.01mm Z axis manual motion distance: 400~600mm (distance between SR-3AR lens and Diffuse Sheet).
WGS-L020 Flat Steel/Ribbon Iron Width Measuring System Overview Whether the width and thickness of the flat steel/ribbon iron width measurement device can meet the standard in the production process directly determines the quality of the flat steel/ribbon iron. How to carry out high-precision measurement of flat steel produced at high speed is the key technology to improve the production efficiency and quality of flat steel. The flat steel/ribbon iron high-speed width measuring system developed by our company can monitor the whole process of flat steel production in real time. It can be used for the on-line analysis, processing, display and function alarm for the detected parameters of the width and thickness. We can provide customers with professional solutions. The measuring principle of the system The device adopts industrial laser sensor, through the principle of laser triangulation reflection: the laser beam is amplified to form a laser line and projected onto the surface of the object to be measured, the reflected light passes through the high-quality optical system to be projected onto the imaging matrix. Then the distance (Z axis) from the sensor to the measured surface and position information (X axis) along the laser line can be got after calculating. By moving the measured object or sensor, a set of three-dimensional measured value can be obtained. When measuring, we need to install a laser measurement sensor device directly above and below the ribbon iron. When the ribbon iron passes through, the width distance from the left and right of the ribbon iron and the height distance from the sensor to the ribbon iron can be measured by laser scanning. The thickness of flat steel can be measured by two sensors up and down. The flat steel width measuring system is mainly composed of line laser measurement sensors, connectors, front-end data acquisition, operation station (workstation) and server, mechanical structure, cooling protection device, etc. These devices form an independent measurement and calculation network, and through the high-speed data measurement and calculation of the system to achieve the alarm control of the detection record. The technical parameters Measuring distance: less than 300m (according to the on-site environment) Resolution: 0.05mm Repeatability: 0.1mm Measurement frequency: 80KHz Measurement output frequency: 50Hz (adjustable) Laser class: 2 (IEC60825-1:2014) Protection class: IP65 Communication: TCP/IP communication Measurement range of temperature Working temperature
Rain Water Sensing and Alerting System-Remote Operation Installation: The system Contains one main Module. This can be placed inside building The rain sensor is installed at the place of measurement.There is wire connection between sensor and main Module Operation: The sensor reads the rain drops and send data to main unit. The main unit alert the operator about the rain condition through Missed Call / SMS. Optional: The main unit attached with the Wifi Module can send data to any cloud server for continuous data logging.