The KCT range of split core current transformers have been specifically designed to be small CT and easy to open and yet maintain the accuracy required for kwh meters. The benefit of a split core current transformer is that it can be placed into position easily and without disturbing or disconnecting the main cables it is monitoring. The KCT range of current transformers has two insulated terminal covers for connecting the S1 and S2 cables which lock down over the terminal screws fully insulating the connections. This makes it ideal to use Autometers cable hamesses which are colour coded and individually numbered on each conductor ensuring simple and easy connection from the current transformer to the electricity meter.
The Aluminium Incinerated scrap is the by-product derived from the reprocessing IBA Incinerator bottom ash). It can be classified as follows: Basel code B1010. EW Code: 17 04 02. With a low melting point at 660'C, on visual inspection, aluminium can be found as melted and re-solidified particles or rocks. This happens to aluminium foil that is converted into small droplets during the incineration process. Some larger and thicker aluminium packaging items can still be partially recognised as they retain their shape. The heterogeneous nature of the processed material is due to the diversified conditions present in the combustion chamber, (some relatively cooler regions in the furnace). The stock can contain all kind of aluminium packing. We can currently provide this material in three different fractions and with different aluminium content: 3-8 mm split in two different qualities: 65% ± 3% Al 85% ± 3% Al 8-16 mm: about 70% ± 3% Al 16-60 mm: about 80% ± 3% Al The material contains minor impurities typically stones, ash, glass. Such components are inherent and adhere to the scrap surface. The total impurities can be sorted, but not fully removed. The collected stock is stored in warehouse on cemented flooring. It can be loaded loose in 20' Feet heavy duty container.
HK Series split core current transformer is HEYI Electrical current transformer manufacturer newly developed products and the split core CT are designed in particular for esay installation, the quick release button makes the ct the most convenient to fit around cables without cutting off the circuitry. HK current transformer has advantages of bigger capacity and bigger mounting hole size, could be used in more power applications.
SCT range of split core current transformers have been specially designed to facilitate their installation in new or already existing net works. They may be installed without opening any cable or bus-bar circuit. An ineternal precision resistor across the secondary winding of the ct provides a low safe voltage output.
UK Series split-core current transformer has been specially designed to facilitate their installation in new or already existing networks. They may be installed without opening any cable or bus-bar circuit.An internal precision resistor across the secondary winding of the CT provides a low safe voltage output.It can save time and the installations costs. Features Doubie-screw fastening,safe,easy to install,portable. Wide inner window,allowing clamping of big cables or bus-bars. Wide range of sizes to accommodate all the existing installations. Application Current measurement,monitoring and protection for electrical wiring and equipment. Current and power measurement for electric motors,lighting,air compressor,heating and ventilation system,air-condition equipment and automation-control system. Current,power and energy monitoring device. Relay protection device
KF series split-core current transformers. The CT can be mounted to existing panels, such as control centers or load centers, to measure or monitor voltage. These CTs can be mounted without removing existing cables for easily installation.
Ginger (Zingiber Officinale) is a commodity that is highly valued in international markets for its aroma, pungency and high oil and Aleo resin content. Nigeria is the third largest exporter of ginger in the world after China and India. Most of the dried ginger that are available for international trade are simply sun dried over a few days, but artificial drying is also used in areas lacking a defined dry season to coincide with the harvest. The rhizome is dried to 10-12 percent moisture content. Dried ginger is usually presented in a split or sliced form. Splitting is said to be preferred to slicing, as slicing loses more flavor, but the sliced are easier to grind and this is the predominant form of dried ginger currently in the market
Jiangyin Spark XH-SCT-T24 Series split-core current transformer , Diameter 24mm , Max rated current 300A ,output 0.333V ,1.0% class ,UL list Features: Small size, low cost High secondary turns Secure locking hinge Features: Maximum continuous primary current 5A to 300AAC Current Ratio: 3000: 1 Output: 0.333 Volt or mA at rated current Accuracy: �± 1% from 5% to 120% of rated current Insulation Voltage: 600VAC Maximum Primary Voltage: 5000VAC(Insulated Conductor) Phase angle: Less than 2 degrees at 50% of rated current Frequency Range: 50 Hz to 400 Hz Operating Temperature: -15C to 60C. Leads: 4Foot(105cm), UL 1015, Twisted Pair, 0.34 mm2(22AWG) CE recognized, and RoHS compliant Output and leads can be customized
DAQGPCT485 split core current transformer is a kind of current sensor transformer which can convert AC analog signal into RS485 digital signal launched by Shanghai Data Acquisition IOT Technology Co LTD The product has builtin 32bit ARM series MCU and highprecision metering chip and is a multipoint calibrated current conversion module It has the characteristics of high precision and fast response DAQGPCT485 can directly interact with common data acquisition gateways DTU programmable controller PLC and host computer This product is widely used in AC motor lighting equipment air compressor heating ventilation and air conditioning equipment building selfcontrol system equipment OEE open rate industrial Internet rural power transformation projects and other scenarios of current monitoring and acquisition scenarios 2 Service Concept Our company solemnly promise you You buy more than just products but also meticulous and thoughtful technical support We provide free remote guidance remote configuration and commissioning services and send data to the server specified by the customer Free IOT solution consulting services 3 Product Characteristic Parameters Line Sequence Definition Red12V BlackGND Yellow485A White485B Length of LineDefault 1 meter Acquisition Characteristic Current detection range AC 02A100AOther large range transformers can be customized Electrical Characteristic Power supply mode524V DC Operating power consumption05W Operating frequency5060Hz Communication Characteristic Transmission modeRS485 Communication protocol Modbus RTU Structural Characteristic MaterialABS plastic housing Installation methodBuckle mounting Working Environment Temperature 20C70C Storage Environment Temperature 20C80C 4 The Core Advantages of the Product High precision measuring chip high measurement accuracy Open type design easy to install Easy installation and fast deployment helping IOT projects land quickly 5 Description of the Modbus Communication Protocol 51 Serial Port Communication Parameters Baud rate9600 Data bit8 Verify NONE Stop bit1 52 Function Code Definition The upper computer uses 03 function code to read data or receive alarm data The host computer controls the lower machine equipment transformer using 06 function code
Technical parameters Standards IEC60044-1; IEC 61869-2; NTC 2205; GB1208-2006; ANSI C57.13 Accuracy Class 0.5S, 0.5%, 1%, 3% Range of primary rated current 100-1000A Range of Rated load 10VA Rated frequency 50/60Hz Rated secondary current 5A or 1A Rated short-time thermal current 40kA, 1S Rated continuous thermal current 150%I1n Secondary winding power frequency withstand voltage 3kV, 1min Safety Factor Rating (FS)
Divanti Group generates large volume of iCORE and Core 2 Duo Laptops monthly. Each lot is separated by either iCORE Laptops or Dual Core/Core 2 Duo Laptops. Our approximate order ranges from 100-300 units on average. If you are interested in purchasing laptops in bulk, feel free to send me your email address and I can send over current stock lists that is available. Thank you.
1.Features: Double-screw fastening, safe, easy to install, portable Wide inner window, allowing clamping of big cables or bus-bars Wide range of sizes to accommodate all the existing installations 2.Application: Current measurement, monitoring and protection for electrical wiring and equipment. Current and power measurement for electric motors, lighting, air compressheating and ventilation system, air-condition equipment and automation - control system. Current, power and monitoring device. Relay protection device. Company introduction 1.certification We have passed ISO9001:2015,CE,SGS approval and IEC report 2.Company profile Tianjin Grewin is concentrating on transformers for 20 Years and complianted by ISO9001:2015,CB,IEC CB,CE etc.We're always pay great attention to its business philosophy "Quality and Honesty First".Grewin is specialized in the design and manufacture of wound components such as transformer,current sensors, chokes etc .windely used in communications,electronics,meters,industrial control,medical equipments and other fields.We are also a provider of power meters and instruments locators. 85% of its products exported to America, Europe, and Asia etc.We sincerely invite you to join us to create a bright future. 3.Shipping: (1)Products are shipped via UPS / DHL / EMS / HK EMS / FedEx / TNT and so on expresses (door to door). (2)We Provide Drop shipping Service. (3)20 days around delivery upon receiving payment if the qty is lower than 1000PCS and it is not customized products. (4)Shipping via EMS. UPS. FedEx and TNT express usually takes 3~7days dependent on the destination country. 4.Payment terms: (1)T/T 100% or 50% deposit by T/T in advance, balance amount to be paid 7 days before delivery. (2) By irrevocable L/C at sight, to be issued immediately against confirmed order. (3)Payment by T/T, if order amount is less than USD 20,000. 5.Warranty: (1)We provide 1 year warranty. (2)If the product is defective, please notify us within 3 days of delivery. (3)All products must be returned on their original condition, in order to qualify for a refund or exchange of goods
CY-KCT02 From 100A~6000A , Secondary current could be 5A 1A .. Features: .High quality compressivemeasurements .Available in a wide range oftransformer ratings .Accuracy up to Class 0.5 .Foot or burbar mounted TypicalApplication: .Switchgear .EnergyManagement Systems .InstrumentationEquipment .SplitCore Current Transformers are designed for assembly to an existing electrical installation no needto dismantle the primary busbar or cables.
RATTAN NATURAL CORE Rattan is a type of climbing palm that is very long with a slender stem which maintains an almost uniform diameter throughout its length. It grows in a manner similar to a vine, but has an inner core and is not hollow like bamboo. The outer portion of the stem is extremely hard and durable, while the inner portion of the stem is softer and porous. The shade in the rain forests is very dense and climbing on tree limbs is the most practical way for the rattan vines to reach the light above the forest canopy. This makes Rattan ideal for continuous strips of reed and it is considered to be one of the strongest woods available ideal for weaving. The straight rattan is usually steamed and then bent into the desired shape through the use of specialized shapers. Once the rattan has dried, it will retain its shape forever. These rattan poles are often used to form the frames of what will become rattan/ wicker/ woven conservatory furniture such as chairs, tables and sofas. Rattan is incredibly durable and can withstand extreme heat without splitting or drying out so is the ideal solution in conservatories.
HEYI open core transformer KCT
The KCT range of split core current transformers have been specifically designed to be small CT and easy to open and yet maintain the accuracy required for kwh meters. The benefit of a split core current transformer is that it can be placed into position easily and without disturbing or disconnecting the main cables it is monitoring. The KCT range of current transformers has two insulated terminal covers for connecting the S1 and S2 cables which lock down over the terminal screws fully insulating the connections. This makes it ideal to use Autometers cable hamesses which are colour coded and individually numbered on each conductor ensuring simple and easy connection from the current transformer to the electricity meter. Features: 1:The structure of the self-locking, safe, easy to install, portable 2:Wide inner window, allowing clamping of big cables or bus-bars 3:Wide range of sizes to accommodate all the existing installations 4:Isolated plastic case recognized according to UL94-V0 5:Wires plugs,Audio plugs,Power plugs and so on five kinds of plugs Applications: 1:Current measurement, monitoring and protection for electrical wiring and equipment. 2:Current and power measurement for electric motors, lighting, air compressor,heating and ventilation system, air-condition equipment and automation â?? control system. 3:Current, power and energy monitoring device. 4:Relay protection device. Model Guide: 1) KCT-6: inner hole size: 6mm, Ratio: 5A/2.5mA, 10A/5mA, 20A/10mA 2) KCT-10: inner hole size: 10mm, Ratio: 5A/2.5mA, 20A/10mA, 60A/20mA, 75A/25mA, 1~75A/0.333V 3) KCT-16: inner hole size: 16mm, Ratio: 100A/33.3mA, 100A/40mA,120A/40mA, 200A/66.7mA, 100~200A/0.333V 4) KCT-24: inner hole size: 24mm, Ratio: 100A/40mA, 200A/40mA, 200A/66.7mA, 400A/80mA, 100~400A/0.333V 5) KCT-36: inner hole size: 36mm, Ratio: 300A/100mA, 400A/40mA, 500A/50mA, 600A/60mA, 300~600A/0.333V
The KCT range of split core current transformers have been specifically designed to be small CT and easy to open and yet maintain the accuracy required for kwh meters. The benefit of a split core current transformer is that it can be placed into position easily and without disturbing or disconnecting the main cables it is monitoring.
Technical parameters Standards IEC60044-1; IEC 61869-2; NTC 2205; ANSI C57.13; GB1208-2006 Rated primary current 500-1500A Rated load 20VA Rated frequency 50Hz or 60Hz Rated secondary current 5A or 1A Rated short-time thermal current 40kA, 1S Rated continuous thermal current 120%I1n Secondary winding power-frequency voltage 3kV, 1min Instrument security factor FS10 Mechanical parameters Dimensions (WDH) (mm) 120x185x100 Weight (kg) 7 Operating conditions Operating temperature -35C to +55C Daily average temp
FEATURES Most cost-effective Faster installation Safe and easy installations High accuracy 0.5 Holding wire diameter: �?16mm Measurement range of 1mA to 200A AC Low phase shift for power measurement Output model: Lead output(2.5m) Isolated plastic case recognized according to UL94-V0 Small-size, compact size, light-weight Over-Voltage protection circuit is installed. CE, UL / EN 61010 - 1 certified PARAMETERS Technical parameters Standards IEC/EN60044-1 & IEC61010-1 & IEC61869-2&ANSI C57.13 Ratio 1000: 1 or 2000:1 , customized Nominal input current Primary current 20A/30A/40A/50A/60A/80A/100A/150A/200A Overload withstand 1.2 times rated current continuously Accuracy 0.2%, 0.5 %, 1% System Voltage 720V(0.72kV) Output signal 10mA-200mA AC optional 333mV AC or 100mV-2V optional Frequency range 40 Hz-500 Hz Dielectric strength 3KV 50Hz/60Hz at 1 minute Output Standard 2.5 meter cable Protection Level 3.0V0-P Installation Category CAT or CAT 600VAC Max. jaw opening 16 mm Mechanical parameters Dimensions (WDH) (mm) 38mm 55mm 18mm Weight(g) 60 Operating conditions Operating temperature -25C to +55C Relative Humidity 0-85% non-condensing Altitude
Technical parameters Standards IEC60044-1; IEC 61869-2; NTC 2205; ANSI C57.13; GB1208-2006 Rated primary current 100-1500A Rated load â?¤10VA Rated frequency 50Hz or 60Hz Rated secondary current 5A or 1A Rated short-time thermal current 40kA, 1S Rated continuous thermal current 120%I1n Secondary winding power-frequency voltage 3kV, 1min Instrument security factor FS10 Mechanical parameters Dimensions (WDH) (mm) 80x110x50 Weight (kg) 2.1 Operating conditions Operating temperature -35C to +55C Daily average temp