Goniophotometric 1) auto range switch 2) function: luminous flux, luminance, illuminance. 3) fine v() and cos corrected detector, class 1 according to gb/t7403 standard 4) low zero drift, high accuracy 5) 5 digit display 6) accuracy of luminous intensity: class 1 7) rs-232-c interface Hp200z-measurement accessories Integrating spheres 1) internal diameters: 0.5m/1.0m/1.5m/2.0m 2) work with all instrument systems spectrometers Photodetector 1) fine v()-approximation and cosine corrected. 2) accuracy: classa 1) auto range switch 2) function: luminous flux, luminance, illuminance. 3) fine v() and cos corrected detector, class 1 according to gb/t7403 standard 4) low zero drift, high accuracy 5) 5 digit display 6) accuracy of luminous intensity: class 1 7) rs-232-c interface Hp200z-measurement accessories Integrating spheres 1) internal diameters: 0.5m/1.0m/1.5m/2.0m 2) work with all instrument systems spectrometers Photodetector 1) fine v()-approximation and cosine corrected. 2) accuracy: classa
Photometer 1) voltage output range: dc 6v/12v/24v/50v(auto range switch) 2) current output range: dc 0.1ma - 2.500a 3) current drift at full range: 0.05% reading/8 minutes 4) accuracy of a: (0.08% reading 0.02% range) 1) voltage output range: dc 6v/12v/24v/50v(auto range switch) 2) current output range: dc 0.1ma - 2.500a 3) current drift at full range: 0.05% reading/8 minutes 4) accuracy of a: (0.08% reading 0.02% range)
Spectrometer 1)meet the requirements of gb & cie 2)tested luminaires installation with cross laser aiming 3)intelligent photodetector with fine v(d) correction 4)photometric accuracy: first-grade standard 5)angle accuracy: ¦0.2¦ 6)testing optical distance: 0.5m, 1m, 1.6m 7)range of effective intensity: 0.1lx - 30, 000lx 8)spread angle of light beam: (50%), (75%), (25%) 9)measuring data can be applied for lighting design by other lighting softwares 10) rs-232c interface, based on window sxp/2000
Spectrometer, spectroradiometric measurement system, photometer, goniophotometric, led chip measurement system, luminous intensity distribution meter, digital power meter, constant current power source, emi testing system, multiplex temperature meter, integrating spheres, standard light source, optical.
Spectrometer 1)peak value and quasi-peak value range: 20db¦v--130db¦v(9khz--150khz), 10db¦v--90db¦v(150khz--30mhz). 2)frequency scaning range: 9khz--150khz(band width:200hz), 150khz-30mhz(band width:9khz). 3)frequency scaning step length: 100hz/200hz/400hz/(9khz-150khz), 5khz/10khz/20khz (150khz-30mhz). 4)scaning interval: 50ms/100ms/200ms(9khz-150khz), 5ms, 10ms, 20ms(150khz-30mhz). 5)accuracy: ¦3 dbuv. 6)input resistance 50, max input signal:2v. 7)use 50/50¦h+5 single phase v-type simulative network according to cispr standard. 8)meet the testing requirement of fcc, en55015, en55022, gb17743, limit value freely set, for the convenience of customer. 9)windows xp pro and windows 2000 compatible software. 1)peak value and quasi-peak value range: 20db¦v--130db¦v(9khz--150khz), 10db¦v--90db¦v(150khz--30mhz). 2)frequency scaning range: 9khz--150khz(band width:200hz), 150khz-30mhz(band width:9khz). 3)frequency scaning step length: 100hz/200hz/400hz/(9khz-150khz), 5khz/10khz/20khz (150khz-30mhz). 4)scaning interval: 50ms/100ms/200ms(9khz-150khz), 5ms, 10ms, 20ms(150khz-30mhz). 5)accuracy: ¦3 dbuv. 6)input resistance 50, max input signal:2v. 7)use 50/50¦h+5 single phase v-type simulative network according to cispr standard. 8)meet the testing requirement of fcc, en55015, en55022, gb17743, limit value freely set, for the convenience of customer. 9)windows xp pro and windows 2000 compatible software.
LSG-1800B Lamp LED on-line Goniophotometer for LED Light Measurement Introduction: LSG-1800B Goniophotometer is high precision automatic goniophotometric instrument for luminous intensity distribution measurements with facility for turning the light source. The LSG-1800B is an update version for LSG-1800, the LSG-1800B use a constant temperature detector, Japanese Motor and Germany precision angle coder which keeps high test accuracy. It is for industrial laboratory measurements the photometric data of luminaires. Be utilized to measure photometric parameters of luminaires for LED road lighting fixture, room lighting fixture and projecting lighting fixture, such as spatial intensity distribution curve, spatial iso-intensity curve, intensity distribution curve on each section (represent by right-angled coordinates or polar coordinates, luminance limitation curve, luminaire efficiency, glare grade, effective beam angle, upward luminous flux ratio, downward luminous flux ratio, total luminous flux, effective luminous flux, utilization factor and electric parameters voltage, current, wattage, power factor and etc. The measured data meets IES standard format and can be applied for lighting design by lighting design software. The measurement system fully satisfies the requirement of lighting design work. http://www.lisungroup.com/ wooden case
LSG-1800BCCD Goniospectroradiometer is high precision automatic goniophotometric instrument for luminous intensity distribution measurements with facility for turning the light source. The LSG-1800BCCD can do the spatial CCT test when do the intensity distribution test. It is for industrial laboratory measurements the photometric data of luminaires such as LED luminaries, HID lamps, fluorescent lamps and so on. Measurement: Luminous Intensity Data, Luminous Intensity Distribution, Zonal Luminous Flux, Luminaries Efficiency, Luminance Distribution, Coefficient Of Utilization, Luminance Limitation Curves Glare, Maximum Ratio of Distance to Height, Equal Illuminance Diagrams, Curves of Luminaires VS Lighting Area, Isocandela Diagrams, Efficient Luminescence Angle, EEI, UGR, CCT, CRI, Color Temperature Distribution, Spectrum, (x, y)/(u, v) and etc. Specification: LSG-1800BCCD Goniospectroradiometer=LSG-1800B Goniophotometer System + LPCE-2 Integrating sphere Spectroradiometer System The Europe classical goniophotometer which is fully meet EN13032-1 clause 6.1.1.3 goniophotometer type 1. â?¢ The goniophotometer can do the B-β test with two pillars and C-γ test with single pillar & multi-function jigs â?¢ The accuracy of angle: 0.1° (LSG-1800XCCD/LSG-1800BCCD) and 0.2° (LSG-1700BCCD) â?¢ Work with High Accuracy and quick CCD Spectraidomeeter to measure spatial color parameters. â?¢ Accuracy of chromaticity coordinate: ±0.0005 (under standard A lamp) â?¢ Spectral Range Wavelength: 380nm ~780nm; Accuracy of wavelength: ±0.5nm â?¢ Accuracy of photo detector: CIE Class A (Class L is for option) â?¢ Connect to PC via USB, English version software can be run in Win7, Win8 or Win10 â?¢ The test result can be exported as CIE, IES, LDT and other format files. This kind of format files can be transferred by other illumination and luminaire design software such as DiaLux Max Size for the Testing Lamp (mm) The Max Size for the Testing Lamp Max Weight Non-Flood Lamp Diameter*Depth Flood Lamp (L*M) LSG-1800XCCD Φ 2500*550mm 700*600mm 60Kg LSG-1800BCCD Φ 1600*550mm 700*600mm 50Kg LSG-1700BCCD Φ 1600*580mm 700*600mm 30Kg