Specifications Op 2.1 duplex service drop Applications To supply 120 volt aerial service for temporary service at construction sites, outdoor or street lighting. For service at 600 volts or lower at a conductor temperature of 75 maximum. 2.2 triplex service drop Applications To supply power from the ulility`s lines to the consumer`s weatherhead. For service at 600 volts or less(phase to phase ) at a conductor temperature of 75 maximum for pe insulation or 90 maximum for xlpe insulation. 2.3 quadruplex service drop Applications To supply 3 phase power, from a pole-mounted transformer to the use`s servic head where connection to the service entance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperature not to exceed 75 for pe insulated conductors or 90 for xlpe insulated conductors. Conductor standards: 1. B-230 aluminum wire, 1350-h19 for electrical purposes. 2. B-231 aluminum conductors, concentric-lay-stranded. 3. B-232 aluminum conductors, concentric-lay-stranded, coated steel reinforced (acsr). 4. B-399 concentric-lay_stranded 6201-t81 aluminum alloy conductors. 5. B498 zinc-coated steel core wire for aluminum conductors, steel reinforced (acsr). 6. Duplex service drop cable meets or exceeds all applicable requirements of ansi/icea s-76-474
Application :- The XLPE (Cross Link Poly Ethylene) Power Cables are used under ground as well as over head transmission of power in power plants, industries, projects and all other electrical installations. Features :- Manufactured from bright annealed 99.97% pure bare copper & aluminum conductors. These cables are insulated with XLPE compound. Taped/Extruded inner sheath. Round steel wire / flat galvanised steel grip armoured. The outer sheaths can be PVC, HR PVC, FRLS or FR depending upon the application and requirement. Technical Advantage of XLPE Insulation :- Higher current rating, higher short circuit rating (approx 1.2 times that of PVC), thermosetting in nature, higher insulation resistance (1000 times more than PVC cables), higher moisture resistance, better resistance to surge currents, low dielectric losses, better resistance to chemicals and corrosion, longer service life. Comparatively higher cable operating temperature 90�°C and short circuit temperature 250�°C. Technical Data :- Working Voltage : Up to 1100 V Temperature Range : -15�°C to +90�°C Power Cable Sizes : 1.50 Sq. mm to 400.00 Sq. mm in 2, 3, 3 Copper Control Cable Sizes : 1.50 Sq. mm, 2.50 Sq. mm up to 24 cores. Color Codes : 2 Core Cables - Red, Black 3 Core Cables - Red, Yellow & Blue 3 Core Cables - Red, Yellow, Blue & Black (for Neutral) 4 Core Cables - Red, Yellow, Blue & Black 5 Core Cables - Red, Yellow, Blue, Black & Grey 6 Core Cables & above - Adjacent cores are blue for reference and yellow for direction in each lay Black outer sheath Specification : IS:7098 (Part-1) Packing : 500 / 1000 meters on drums
Glazing glass is a combination of two or more pieces of glass spaced apart with a spacer bar and hermetically sealed with a primary and secondary sealant to form a single unit with one or more air spaces between each other. Max size :3300*12000mm Main character : Energy saving , improving the thermal performance Sound insulated Security and comfort Component : 1.� Glass items:� consists of hard or soft low E glass ,reflective glass ,clear glass ,tinted glass, with types of flat tempered ,bent ,laminated processing ,according to the application 2.� Spacer bar :is the material used to separate the two glass lites in an IGU. It can be made by aluminum,stainless steel,hybrid ,plastic material . The spacer width usually from 6mm-18mm.
Application :- The Power Cables are used under ground as well as over head transmission of power in power plants, industries, projects and all other electrical installations. Features :- Manufactured from bright annealed 99.97% pure bare copper & aluminum conductors. These cables are insulated with PVC compound. Taped/Extruded inner sheath. Round steel wire / flat galvanised steel grip armoured. The inner & outer sheaths can be PVC, HR PVC, FRLS, HR-FRLS or FR depending upon the application and requirement. Technical Data :- Working Voltage : Up to 1100 V Temperature Range : -15�°C to +70�°C or +85�°C in HR PVC Power Cable Sizes : 1.50 Sq. mm to 400.00 Sq. mm in 2, 3, 3 & 4 core. Copper Control Cable Sizes : 1.50 Sq. mm, 2.50 Sq. mm up to 24 cores. Color Codes : 2 Core Cables - Red, Black 3 Core Cables - Red, Yellow & Blue 3 Core Cables - Red, Yellow, Blue & Black (for Neutral) 4 Core Cables - Red, Yellow, Blue & Black 5 Core Cables - Red, Yellow, Blue, Black & Grey 6 Core Cables & above - Adjacent cores are blue for reference and yellow for direction in each lay Black outer sheath Specification : IS:1554 (Part-1) Packing : 500 / 1000 meters on drums
NFC 33209 0.6/1 kV Aerial bundled Cable ABC Cable NFC 33209 0.6/1kV Aerial bundle Cable ABC Cable XLPE Insulated Cable ABC Cable Application NFC 33209 0.6/1kV Aerial bundle Cable ABC Cable XLPE Insulated Cable is the overhead insulated cable, used as public lighting wire or testing wire etc. Aerial bunched cable 0.6/1kV is extensively installed in urban and forest region which provides the safety and reliance for public power distribution network. ABC Cable Characteristics Rated Voltage Uo/U (Um) :0.6/1kV (1.2kV) Temperature Rating: Operation temp.:90 Short Circuit Temp.:250 Minimum Bending Radius:Single core: 13�?OD; Multi-core: 6OD(min) while 12OD during installation ABC Cable Construction Aerial Bundle Conductor(ABC) Aerial Bundled Conductors (Phase Core): Circular, Class 2 stranded conductor, round compacted or non-compacted AAC conductor, AAAC conductor, or ACSR. Aerial Bundled Conductor Messenger or Neutral Core:Circular, Class 2 stranded conductor, round compacted or non-compacted AAAC conductor (All Aluminium Alloy Conductor), AAC conductor(all aluminium conductor); ACSR conductor(Aluminium Conductor Steel Reinforced conductor), Neutral Core Sizes: 54.6mm2, 70mm2, 95mm2 ABC Conductor Lighting Conductor:Circular, Class 2 stranded conductor, round compacted or non-compacted AAC conductor, AAAC conductor, or ACSR Aluminium conductors ABC standard as per NF C 32-013, IEC 228 & IEC 228A LV Aerial Bundled Cable Insulation Overhead Conductor (ABC) Insulation: Low Density Polyethylene (LDPE), High Density Polyethylene(HDPE), XLPE(cross-linked polyethylene ), Polyvinyl chloride(PVC). Aerial Bunch Cable Standard As one of leading ABC Cable suppliers, we produce aerial bunched cables meeting NFC 33029, IEC60228, NF C 32-013ï¼?NFC 32 013, AS/NZS 3560.1,BS 7870-5,ANSI/CEA S-76-474,NTP 370.254 etc
http://www.xlpecable.com/zmscable/cable_119_1.html
http://www.xlpecable.com/zmscable/cable_119_1.html
Cable wire, AAAC, AAC, ABC cable and XLPE and PVC insulated cables.
XPS Insulation (Extruded Polystyrene): "XPS" commonly refers to extruded polystyrene insulation. This type of insulation is known for its closed-cell structure, providing good thermal resistance and moisture resistance. It is often used in various construction applications, such as insulating walls, roofs, and foundations. B1 Fire Rating: The "B1" component might refer to a fire rating. In some fire classification systems, materials are rated based on their fire resistance, and "B1" could indicate a certain level of fire resistance. For example, in the European fire classification system (Euroclass), B1 represents a material with limited combustibility.
Floating cable which can be applied to underwater robot equipment, either in fresh water environment or in seawater environment. It is widely used in marine exploration robot, underwater ROV UAV remote control submersible, underwater camera, underwater construction, underwater search and rescue robot, pipeline detection robot, submersible pump and the link between various underwater electrical equipment and shore based equipment; Link of signal transmission, power supply and equipment control system from underwater to water.
Application Use for control and connecting cable on data transmission within building management system, speaker audio system and control measurement. Suitable for use in dry and damp environment. Cable Structure & Features Conductor Material : Tinned copper stranded Insulation : Semi-Rigid PVC Drain Wire : Tinned copper stranded Shielding : Aluminium foil laminated screen Outer Sheath ; PVC Sheath Colour : black or gray Technical Data Standard : UL Style 2464 Approvals : UL apporoved Rated Voltage : 300V Testing Voltage : 1500V Flame Retardant : VW-1 Insulation Resistance : Min 20Mx km Min. Bending Radius : 10 x cable diameter Operating Temp. : -30C / +80C
Flat Cable M&P is able to support a full line of flat cable and flat ribbon cable for electronic applications. Providing both power and data transmissions, flat cables are mainly used for internal connections within the equipment. They are available in a wide range of configurations to accommodate different connection and data transmission requirements and the range of sizes of the equipment using the cables. Flat cables provide consistent performance due to their layout and the spacing between the cables and are lighter, thinner and more flexible than other cables. Features of Our Flat Cables & Wire * Flat, ribbon and twisted configurations, with different levels of flexibility. * Shielded or jacketed cable to reduce signal interference. * Range of pitches and pin configurations to accommodate the application requirements. * Easy to fasten with clamps, adhesive, and tape. We provide custom services, including marking, kitting and custom cable design to provide you with a custom solution for your cabling application. Contact us to find out more about Flat Cables and Wires.