Features of digital hour meter: Displays rpm, hours Programmable no. Of teeth Programmable Specifications : Supply: 8 – 35vdc Dimension 72*72*80
Description Applicable to the movement of the holzer signal device, without the valve base meter. Features Only meter reading, network remote transmission, urban networking, mechanical and electrical separation.
High accuracy : It is a high sensitivity water meter that detects a little flow with R200 high accuracy. Battery Life: The low-power design enables the water meter to last longer than 10 years.
Product Description Major technical data: Accuracy class: 1.0 Power consumption: 20 years. Main functions: 1) Measurement of 50hz for 3-phase active power 2) 4 tariffs and 8 time periods for user's option 3) RS 485 communication functions 4) Manual and remote control program, and remote-metering functions 5) To record the parameters automatically through CMRI. Features: 1) High accuracy, reliability, overload capability 2) Low power consumption 3) Smt technology and re-flow soldering technology 4) Light weight, small size, easy to install. Model: DTSF318/DSSF318 Standard: IEC 62052-11 IEC 62053-21 IEC 62056-21 Productivity: 100.000pcs/year.
Single phase long life electronic energy meter Major technical data: Name of product: single phase long life electronic energy meters Type: dds 318 Accuracy class: 1.0 Power consumption :< 6va Rated voltage: 220v 240v Rated current: 2.5(10) a 5(30) a 10(50) a Application: By adopting advanced pcb and smt technology, dds318 single phase long life electronic energy meter is used to measure the energy of 50hz single phase a.C power. Salient feature: 1.High accuracy:1.0class 2.High overload capacity: 6 times of overload. 3.High reliability: long operating life. 4.Low power consumption, small size, light weight, tamper proof and easy to install. 5.Smt and re-flow soldering technology is adopted. Meter has strong capability for disturbance. Emc can comply with requirement of iec61036-2000. 6.With impulse output interface for direct calibration of the meterf+s accuracy, or for measurement of the impulse input in case of mass-metering. 7.Power indicator to test the optical power end and calibrate the accuracy of the meter. 8.Electric power line carrier system and telephone remote-metering system can be supplied for userf+s option. 9.It can be changed into single phase plc electronic energy meter
Features: 1) high accuracy, reliability, overload capability 2) low power consumption 3) smt technology and re-flow soldering technology Major technical data: 1) accuracy class: 1.0 2) power consumption: less than 4va 3) rated voltage: 200v 4) rate current: 2.5(10)a, 5(25)a, 10(40)a Main functions: 1) measurement of single-phase 50hz active power and power consumed 2) set up maximum load, overload warning and power off 3) warning of remained energy and remind user for payment 4) re-read power consumed, remained energy and number of prepayments for power 5) power off when no energy in the meter 6) parameter transferring through ic card Salient features: 1) high accuracy: 1.0 class 2) high overload: 6 times of overload 3) high reliability: long operating life 4) low power consumption, tamper-proof, light weight, small size and easy to install 5) register displays consumed power, and led displays status of consumed power 6) smt technology and re-flow soldering technology are adopted. Meter has strong Capability for disturbance. Emc can comply with requirement of iec 61036-2000 High overload capacity, high reliability of relay Single-phase and 3-phase pre-payment electronic energy meters can share one set Light weight, small size, easy to install Of prepayment control system
Electronic single-phase power meter Reference voltage 220v Voltage reference un-1 .2 0.7ub Current specifications 5-30a Reference frequency 50hz Grading accuracy + level Starting current 0.005ib = 0.025a Voltage power lines Communication transmission distance no Environmental conditions -25f¬f+70f¬ Relative humidity -_85% Automatic relay depth Data transmission speed Center frequency Dimensions
DEM101 three phase electronic prepayment watt-hour meter Application 1. After power cut down, data reserved forever, The direction of electric power can be distinguished automatically, and has function of anti-stealing electricity. 3. May select many kinds of IC card, have IC card with code and data against false. 4. May select 6 digits LED display or 7 digits LCD display. 5. May select payment controls by kWh or money. Technical parameters Name Type Accuracy Rated voltage) Rated current A) Connection Mode Three phase four wire electronic prepayment watt-hour mete31(2),31.5(6),33(6) Input through current transformer Three phase four wire electronic prepayment watt-hour meter DTSY223(DEM101) Class 1 3380/220 35(25),310(50),315(60),320(80),320(100) Directly input Three phase three wire electronic prepayment watt-hour meter DSSY223(DEM101) Class 1 3380 31(2),31.5(6),33(6) Input through current transformer Three phase three wire electronic prepayment watt-hour meter DSSY223(DEM101) Class 1 3380 35(25),310(50),315(60),320(80),320(100) Directly input
DDS22 Single-phase Electronic Watt-hour Meter adopts special large-scale integrated circuit, high-performance parts as well as advanced SMT technology. Therefore, the meter is characterized with high accuracy, tamper-proof function, high anti-interference, and long service life. The meter is easy to operate and can meet the customers' requirements well for its reasonable design. It is the optimum product for customers and public utilities. Functions and Characteristics: Accuracy Class: 1.0class The meter adopts special anti-magnet impulse meter reading mechanical register to prevent strong disturbance form external AC, DC magnetic field. Flat error curve, stable for temperature and time, and reliable. To cumulate both direct and reverse energy, prevent tamper of reversal of lines. Light weight, reliable structure. Easy to be handled and installation. Anti-tamper in condition that load is connected between the line and the earth. The meter can also prevent U ring short circuit and other tampers. Low consumption: ≤ 0.6W Distant-motion-width-determination pulse output and multifunctional output ports . 20units/Pack
Single phase electronic kwh meter Main features: Active e. C measure mode is optional. Lcd display format is optional. Tamper function(option): 1p2w 1p1w Cover open alarm(option): meter cover or terminal cover Communication port (option): optical port or rs485 Terminal cover: short or long (transparent) One or two rates controlled by external device (option). Ip53 in accordance with iec60529: 198 Sea transportation standard packing
Digital Electronic Tension Meter (DTM-501) for Yarn Copper Wire Fibre DTM Series Digital Tension Meter Tension measuring 128 * 64 LCD display, late-model design, comfor table handfeel , easy operation, measure the value of direct display tension, maximum, minimum, and can store records of measurements to determine the quality control of the actual tension values. It can be widely used in wire, strip processing time of tension measurements (such as: yarn, steel wire, copper wire, copper strip, tape, film, fiber-optic cable, carbon fiber lines, etc.).
Yokogawa mechanical tension meters (yan tension meter) are for accurately measuring the running line tensions on all kinds of wires (cooper, metal, aluminum, plastic and etc). Yarns and fibers. With precise jeweled movement, Precision ball bearing mounted rollers and built-in damper, T1 tension meter completely eliminate the vibration and resistance caused by instrument itself, to provide reliable, accurate and steady tension reading as tension fluctuate. 1. Easy to read: 128*64 LCD display panel, clear display with high bright backlight. 2. Easy to operate: Simple and user friendly fuctional buttons. 3. Easy to hand: Clean Streamlined handle design. 4: Direct display of real time measurement. 5. Powered by replaceable lithium battery. 6. High precision, long service life 7. With memory back up function. Product specification of the tension meter Model Test range Minimum degree T-101 -02 0-20g 0.5g -05 0 -50g 1.0g -10 0 -100g 2.0g -20 0 -200g 5.0g -30 0 -300g 10.0g -50 0 -500g 10.0g T-102 -01 0 -1000g 20.0g -02 0 -2000g 50.0g Advantage of our coil winding wire tension meter 1. Precise tension scale 2. Competitive price 3. Excellent quality of tension meter 4. Various kinds of tension meter for choosen 5. Fast response speed 6. Professional tensioner engineering team 7. Good after-sales service
Electronic KWH Energy Meter Single/three phase static energy meter single/ three phase prepaid static energy meter single/three phase multi-tariff static energy meter single/three phase tamper-proof static energy meter single/three phase wave carrier static energy meter single/three phase multi-function static energy meter single/three phase wireless multi-function static energy meterenergy distribution monitor. And the accuracy class is 0.5, 0.5s and 1.0. The voltage range is from 100v to 480v. And the current range is from 1.5a to 100a. It is packaged by box.
DTZY1122 Three Phase Four Wire Multi-function Electronic Smart Meter brings many enhancements that support emerging needs of smart grid initiatives, such as enhanced memory, greater security, and remote upgrade ability. Developed with technology and communications flexibility in mind, DDZY1122 platform is both a smart metering element that supports RS485, PLCor low-power RF modules. The meter's modular design provides a cost effective solution for many metering applications. Functions and Characteristics Three phase active(reactive) power consumption measurement at different time segment Display: Large LCD display Record, display and store the total active/reactive power consumption and multi rate power consumption during latest 3months. Measurement of maximum demand and billing Two time zones, four rates, ten time periods. Event record of voltage/current missing, programming, demand clearance, etc. Real time data: Time, voltage and current Self verifying and monitoring of power supply, power Network, operation situation of meter. The function setting, programming and reading (concentrated reading possible) can be realized via infrared and RS-485 ports.
Single Phase DIN-Rail Energy Meter (DDS-1Y-L) Executive Standard: IEC62052-11 2003; IEC62053-21 2003 and IEC62056-21(IEC1107) DIN-rail standard: "SO"43864. Function and characteristic: Single measurement(optional RS485 or RS485 Modbus) High accuracy of measure, convenient installation; Logical design of Anti-creep. Technical data: Rated voltage: 110V, 120V, 220V, 230V Rated Current: 1.5(6)A, 5(60)A, 10(100)A Frequency: 50-60Hz Connection mode: CT type; Direct type Display mode: LCD 5+2 = 99999.99kWh Accuracy Class: 1.0 Power consumption: 1W (when 220V 20A) Start current: 0.004Ib Constant: 12800 imp/kWh; 800/1600/3200/6400 imp/kWh Standard work temperature: -20-45 degree Climate work temperature: -30-55 degree Relative humidity: 85%. Size: 100*76*65 mm.
DIN-Rail Single Phase Energy Meter with Counter(DDS-1Y-M) Executive Standard: IEC62052-11 2003; IEC62053-21 2003 DIN-rail standard: "SO"43864. Function and characteristic: Long terminal block; Nameplate inside; Measure power accurately; Anti-creep. Technical Data: Rated voltage: 110V, 220V, 230V, 240V; Rated current: 5(30)A, 5(60)A, 10(80)A, 5(80)A; Frequency: 50-60Hz Connection mode: Direct type Display: Counter 6+1=999999.9kWh Accuracy Class: 1.0 Power consumption: Un1W (when 220V 20A) Start current: 0.004Ib Standard work temperature: -20-45degree. Crelative humidity: 85%. Size: 115*78*65mm.
Three Phase Double Tariff Meter (DTS353) Executive Standard: IEC62052-11 2003; IEC62053-21 2003 DIN-rail standard: "SO"43864. Function and characteristic: Two tariffs; Double LCD; Control tariff by exterior controller; Two display window for two different tariffs T1, T2. Technical data: Rated Voltage: 3*220V/380V; 3*230V/400V Rated Current: 3*5(30)A; 3*10(60)A; 3*10(100)A Frequency: 50-60Hz Connection Mode: Direct type Display: LCD 5+1=99999.9kWh Accuracy Class: 1.0; Power Consumption: Less than 0.6W; Less than 0.3VA Start current: 0.004Ib Constant: 800/1600/3200/6400imp/kWh. Size: 122*100*65mm.
Single Phase kWh Meter Executive Standard: IEC62052-11 2003; IEC62053-21 2003 Function and characteristic: Infrared function; Measurement accurately. Technical data: Rated current: 1.5(6)A 5(30)A 10(40)A 5(60)A 20(80)A Rated voltage: 110V 220V 230V 240V Display mode: LCD 6+1=999999.9kWh Accuracy class: 1.0 Frequency: 50Hz (60Hz) Impulse constant: 800/1600imp/kWh Connetion mode: CT type; Direct type. Size: 153*118*50mm.
DEM031 single phase electronic multi-rate watt-hour meter Application Type DEM031 single phase DIN rail watt-hour meter is a kind of new style single phase electronic multi-rate watt-hour meter, energy data display adopt 7 digits wide temperature type crystal display, with many functions of multi-rate (time-of use) energy measurement, infrared carrier wave communication and RS485 serial port communication reading meter, etc. The meter completely accord with relevant technical requirements of class 1 and class 2 single phase energy meter stipulated in National standard GB/T17215-2002 and international standard IEC61036. it has following features: Good reliability, small volume, light weight, specious nice appearance, convenient installation, etc.1. May select 35mm DIN rail installation or installation on the board. 2. Have 3 tariffs, 12 daily period of times, may select single tariff function in weekend. 3. Inner emplaced clock, after power cut down, the message is preserved forever, inner emplaced spare batteries and free of maintenance. 4. The direction of electric power can be distinguished automatically, accident is checked automatically. 5. Infrared carrier wave communication and RS48 5 serial port communication, meter is set up by program and password is protected. Technical parameters Type Accuracy Rated voltage) Rated current A) Starting Current Insulation Performance DDSF977(DEM031) Class 1 220V 2.5(10),3(15),5(30),10(50),15(90),20(100),5(40),5(100) 0.4%lb AC voltage 2KV for 1 minute impulse voltage 6kv DDSF977(DEM031) Class 2 220V 2.5(10),3(15),5(30),10(50),15(90),20(100),5(40),5(100) 0.5%lb AC voltage 2KV for 1 minute impulse voltage 6kv
Features and benefits Range up to 8m/12m 6 mm range accuracy Easy remote operation, diagnosis and adjustment with KEY/LCD or PC Low processing power Capable 2-wire, loop powered, intrinsically safe inner temperature compensation to ensure accuracy of measurement Non-contact measurement Easy mounting via 1¿÷ NPT Low cost Application Continuous, non-contact level measurement in fluids, pastes, sullies and coarse bulk materials Characteristics Measuring Range Solids applications: 4m/6m (transducer dependent) Liquid applications: 8m/10m (transducer dependent) Measuring Resolution 2mm Accuracy 0.25% of range or 6mm, whichever is greater Max. Pulse Frequency 43.5KHz Operating Temperature -20..+80í+ Operating Pressure 0.7..3 mbar Power Supply 15..30V Power Consumption 51 mW ... 800 mW PCB Size Driver board(Ñ+:84mm), Main CTL board(Ñ+:80mm) PCB Material FR4 LCD Size 128*64dot Description ANL-4012 Ultrasonic Level Measurement Instruments use sound waves to determine level. A piezoelectric crystal inside the transducer mounted on top of the tank converts electrical pulses into sound energy that travels in the form of a wave at the established frequency and at a constant speed in a given medium. The sound waves are emitted in bursts and received back at the transducer as echoes. The Ultrasonic Level Measurement Instrument measures the time for the bursts to travel down to the reflecting surface and return. This time will be proportional to the distance from the transducer to the surface and can be used to determine the level in the tank. Ultrasonic systems are accurate within a range of approximately 8m. A typical installation consists of two parts: A Transducer, consisting of both a transmitter and receiver. Ultrasonic energy is transmitted from the í¦headí¦ in the direction of the liquid surface. When the ultrasonic waves contact the surface, they are reflected back to the receiver in the head. Electronics, which produce, control and time the ultrasonic pulses which are transmitted and received by the head. The electronics also transmit control signals to remote monitoring devices such as displays and process control systems.