Grand electronics specialises in providing onestop service of pcb prototype from pcb layout, pcb fabrication, components sourcing to contract assembly. Its facility locates in Shenzhen and Huizhou covering 16,000 sqft with 650 workforce. It oprates strictly in line with ISO9001, ISO14001, TS16949. The main field our customer serve is communication, home appliance, security, sensor and underwater electronics, instrumentation. No MOQ and one year quality warranty for your boards.
Grand electronics specialises in providing onestop service of pcb prototype from pcb layout, pcb fabrication, components sourcing to contract assembly. Its facility locates in Shenzhen and Huizhou covering 16,000 sqft with 650 workforce. It oprates strictly in line with ISO9001, ISO14001, TS16949. The main field our customer serve is communication, home appliance, security, sensor and underwater electronics, instrumentation. No MOQ and one year quality warranty for your boards.
1.Abt leaded glass: Lead glass is a silica type, of high quality optical grade with over 60 percent heavy metal oxide. Zf2 and zf3 lead glass is mainly used in x-ray room and ct scanning room. Zf6 and zf7 lead glass is mainly used in nuclear industry such as nuclear power station and atomic energy application. 2.Terms: Payment terms:t/t;western union. Shipment terms:fob qingdao, tianjin, shanghai. Delivery time:1-15days to your orders. Packing details:first packed with foams then wooden case 1.With foams 2.With wooden case
Product Model: XXQ-2505 Output Voltage (KV): 150-250 Input (KW): 2.5 Focus Spot (mm): 2.0,2.0 Beam Angle: 40 +5 Max Penetration (mm): 39 (Steel A3) Weight (kg): Generator: 37 Controller: 20 Dimensions (mm): Generator: 320,730 Controller: 365,310,225. * Compact X-ray generator, anode grounded, forced air cooling * Light weight, portable, easy to use * The radio of the exposure time to the stop time is 1:1 * Aging the X-ray generator and checking the exposure parameter automatically * High-voltage time-delay function protects the operator from radiation * Strictly controlled the production technique, nice outward, reasonable designing. Wooden cases, and two cases for one set of x-ray equipment.
Our company produce and supply Industrial X-ray Equipment, X-ray Tube, X-ray Flaw Detector; Medical X-ray Tube; X-ray Tube for security check; and X-ray Pipeline Crawler. Features of X-ray Equipment: Compact X-ray generator, anode grounded, forced air cooling; Light weight, portable, easy to use; The radio of the exposure time to the stop time is 1:1; Aging the X-ray generator and checking the exposure parameter automatically; High-voltage time-delay function protects the operator from radiation; Strictly controlled the production technique, nice outward, reasonable designing. Wooden cases, and two cases for one set of x-ray equipment.
Power output : 15kw Inverter frequency : 40khz X-ray tube : xd56-5 17/130 Small focus: 0.3 large focus: 0.6 Thermal capacity: 212kj (300 khu) The speed of the rotary anode: 3000rpm Tube voltage : 40~125kv Tube current : 200ma Mas : 0.4~360mas Bucky grid : grid density 103l/inch; grid ratio:10:1 Focus distance:150cm stationary 18"íß18"(import) Power supply : 220vía10% 50hz, capacity: í²16kw Operation method : graphic remote-control lcd touch screen And wireless remote-control exposure (optional: control box of graphic remote-control Lcd touch screen)
Bed transverse movement range distance: a110mm Portrait movement of photography frame and track spot film: ²720mm Photography dimension of whole film: 8¦10¦~14¦ 17¦ Spot film division: whole film, 2-division film, 3-division film, 4-division film Method to control bed: remote control, bed-control, soft boot and stay of frequency conversion Beam applicator: electrodynamics multi-pin Bed-applied fixed bucky grid: grid density: 103l/inch Grid ratio: 10:1, focus distance: 120cm, 15¦ 18¦ Digital tv system Ega: 9¦ toshiba, high resolution ccd (digital camera); imported low-light 0.47 mega pilexs Monitor: 14¦ medical high definition monitor, horizontal central resolution 1000 thread, edge 800 Thread, video wideband 12.5mhz, 50bit, 25 pictures per second Picture-process system: high definition and non-interlaced output, 8-grade noise reduction, 7 Pictures in storage, lih, mirror image rotation in vertical and horizontal, positive-negative Image; osd (monitor display)
Category item content Fluoroscopy capacity perspective max rated capacity tube current 8 ma , tube voltage 120 kv Automatic fluoroscopy tube voltage: 40kví½120kv , adjust automatically Tube current :0.3ma~4ma .Adjust automatically Manual fluoroscopy tube voltage 40 kv, 110kv, continuous Tube current :0.3ma~~4ma continuous Pulse frequencetube voltage 40kví½120kv, continuous Tube current : 4.1maí½8ma continuous X ray tubex ray tube special for high frequency bifocus rotary anode x-ray tube: large focus:1.5, s mall focus :0.3; high frequency power supply , main inverter frequency :60khz, thermal capacity :34kj(47khu) Imaging system image intensifier Toshiba 9 "image intensifier (230mm) Video camera ultra-low-light digital camera for medical a / d digits 12bit
Fx-50 mobile x-ray machine Power supply:a.C220v+/-10%, 50hz+/-1hz Especially for medical institutions with poor power supply Technological parameter: Radiography:30ma 50-90kv shifting adjust from 0.1 to 6.3s 50ma-90kv shifting adjustment from 0.1 to 2s X-ray tube :xd61.1.35/100 kv Up and down scope of the arm :500-1800mm Feature: Full-wave communicate, compact structure, especially for areas with poor power supply, universal wheel and brake wheel are adopted, and convenient turning and brake are realized.The whole machine are of compact structure and can conduct radiography in ward Measure:1890mm*740mm*1225mm Gross weight:291kg Measure:1890mm*740mm*1225mm Gross weight:291kg Pack: wood box
Medical green sensitive x-ray film 18x24cm 18x43cm 24x30cm 30x40cm 35x35cm 35x43cm 5x7in 8x10in 10x12in 11x14in 12x15in 14x14in 14x17in
X Ray Doors X-ray doors are a common feature in X-ray rooms, as they provide an effective barrier against harmful radiation. The lead lining in these doors is designed to absorb and block the radiation, protecting those outside the X-ray room from exposure. When it comes to choosing lead lined doors for an X-ray room, there are a few key factors to consider. These include: Level of radiation protection required: Depending on the type of X-ray equipment being used and the frequency of use, different levels of radiation protection may be required. Make sure to consult with a radiation safety expert to determine the appropriate level of lead lining for your doors. Door size and configuration: Lead lined doors can be customized to fit a wide range of sizes and configurations, from single doors to double doors and sliding doors. Consider the layout of your X-ray room and the traffic flow when selecting the right door configuration. Material and finish: Lead lined doors can be made from a variety of materials, including wood, steel, and aluminum. Choose a material and finish that meets your aesthetic and durability requirements.
Year: 11/2007 Remote controlled R/F system
Model Winscope 5000 Manufacturer TOSHIBA Only High voltage generator/KXO-50XM
Year:2011 Name Digital X-ray TV System Model POPULUS Ti Manufacturer HITACHI
Shimadzu Flexavision X-Ray Year: 11/2007 Remote controlled R/F system
GE Proteus X-Ray Year:20/12/2012 Generator:80KW With Ceiling Suspension, Wall buckies and Elevating Table Tube year:03/2017
X-ray TV System Model Winscope 5000 Manufacturer TOSHIBA Only High voltage generator/KXO-50XM
Digital X-ray Year:2011 Name Digital X-ray TV System Model POPULUS Ti Manufacturer HITACHI
Compatible with select DRYVIEW Laser Imagers Offers extended shelf life with 24-month dating to avoid aging inventory issues and costs. A printed virtual notch provides smooth film edges, properly orients the film on view boxes and helps the film more easily slide into envelopes for storage. Suited to a range of imagers and general radiology applications Five film sizes on 7-mil blue polyester base AIQC system-matched with the DRYVIEW Laser Imagers AIQC ensures contrast and density meet preset user preferences Quality control performed without operator intervention to enhance productivity Choose from five sizes on 7-mil polyester base to suit your DRYVIEW Laser Imager and imaging applications: 14 x 17 in. (35 x 43 cm.) 14 x 14 in. (35 x 35 cm.) 11 x 14 in. (28 x 35 cm.) 10 x 12 in. (25 x 30 cm.) 8 x 10 in. (20 x 25 cm.)
Dynamic FPD Radiography and Fluoroscopy System PLD6000 PLD6000 Dynamic FPD Radiography and Fluoroscopy System Features Benefits High Performance and lntelligent DAP Dose visualized safety assuredOptional The pioneer usher in intelligent radiation dose monitoring system Synchronous dose monitoring system of hardware and software guaranteeing more accurate diagnosis Pulsed fluoroscopy Low dose and sharp images Multiple fluoroscopy modes lnstant exposure Lower dose to protect doctors and patients Automatic stiching function accurate and preciseOptional Panoramic images of full spine full lower limbs Accurate measurements of preoperative planning and postoperative surgery Onestep radiography providing more reliable diagnostic basis for clinical practice SlD electrically stretched to 18m Meeting special radiography needs such as standard chest radiography and occupational pneumoconiosis examinations Digital radiography Suitable for radiography of all body parts Digital fluoroscopy Suitable for fluoroscopy of all body parts Digital Gastrointestinal Angiography Esophageal angiographyupper gastrointestinal angiography total gastrointestinal angiography salpingography etc Precise digital spot imaging obtain highdefinition images and accurately capture lesions during fluoroscopy avoiding missed diagnoses and misdiagnosis caused by blind shots 360 rotating foot pedalOptional The loadbearing capacity up to 200KG safely and easily satisfy the inspection needs of various body types Stable and Reliable Image Chain Selfdeveloped ultrahigh frequency and high voltage generator Good Xray source Strong penetration ability Lowdose radiation Stable performance Highquality image High efficiency Flexible flat panel detector Standard highresolution dynamic flatpanel detector SymphonyImage Post Processing System Great image post processing function Only oneclick can finish your work lmported highquality Xray tube Large heat capacity High rotate speed of Xray tube Suitable for long time and highintensity work Have long service life Cloud lmage Interconnection Preset various examine modes The system brings convenience to staff by multiple intelligence control modessimple and fast control interface and efficient image collection will accelerate the speed and improve accuracy of clinical radiography Peset various examine modes Meet the different requirements of outpatient emergencyphysical examination on different cases The system can be maintained remotely it can perform fault selfdiagnosis and display the fault code quickly and accurately determine the fault status and has selfprotection function lt can share information with PACS system bring benefits for remote diagnosis