Main Specification Trademark:CNHUNG/OEM Poles:2P/4P Rated current(A): 25,40, 63 Rated Voltage(V):AC230 / 400V Frequency:50 / 60Hz Rated residual action current(mA):30, 100, 300 -
ABE/ABS moulded case circuit breakeris suitable for industrial or commercial power and lighting with AC50/ 60Hz, rated working voltage up to AC600V/DC250V, rated current up to 630A. Its a kind of economical breaker with the characters of stable and reliable function, beautiful appearance, small size and long life. It can be used for conversion of line and infrequent starting motor. It can also be attached to ins all the accessories which have protection function for avoiding loss of voltage, undervoltage. The product can install connection line with front board and back board, it also can equip hand-operating apparatus or motor-operating apparatus to control in a remote distance.
L7 Miniature Circuit Breaker Application L7 series circuit breaker is used in lighting distribution system or motor distribution system for protection overload and short-circuits in the system. The product is neoteric in structure, reliable and excellent in performance. It has high breaking capacity, can trip quickly, and its case and items are adopted by high fire-resistant and shockproof plastic. The product, with long life, is mainly used in AC 50HZ/60HZ single-pole 230V or two, three, four poles 400V circuit for overload and short-circuit protection as well as for infrequent on-and-off switching electric equipment and lighting circuit in normal case. The products comply with IEC 60898.
DPX series MCCBs are made by Legrand company.And DPX series Moulded Case Circuit Breaker is one of the most advanced type breakers in the world, which adopts international advanced design and manufacture technology. They are suitable for short circuit and overload protection for circuit of AC 690V 50/60Hz, rated current from 12.5A to 630A.Its rated insulation voltage is 690V. It can make and break the nonfrequently circuit in the normal conditions. It takes protect effect when mouse cage motors non-frequent start, breaking off working and protecting overload, short circuit and lacking voltage. It complies with IEC60947-2.
We can supply c45n mcb dz47 mcb, dz47le, c60n mcb, c65n mcb, ic65n mcb, merlin gerin mcb, lg mcb, abb mcb, mem mcb, legrand mcb, lg mcb, nt-50 safety breaker, s101 screw mcb, e4cb mcb, 200b mcb 200bz mcb, l7 mcb, nc-100h mcb, my mcb mt mcb mu mcb, sx mcb, bh mcb, hydraulic magnetic miniature circuit breaker Cm1 mccb cdm1, dpx mccb, hhb mccb, 3vl siemens mccb, am7 mccb, ns mccb, ds mccb, ea mccb, sa mccb, ab mccb, hfd mccb, 3ve mpcb, 3vu cb, gv Mpcb isomax s molded case circuit breaker (abb mccb) , nf-cs mccb(mitsubishi mccb), dpx mccb(legrand mccb), ns mccb (merlin gerin mccb) etc. Moulded case circuit breaker 1. Product net weight: 128g/pole 2. Packing quantity& weight: 12 pole /box, 20 box/carton, 240 pole/carton . 3. N.W: 22.5 kg/carton 4. G.W:24kg/carton 5. Packing measurement: inner box 22.5¡Á9¡Á8 cm, carton 45¡Á23.5¡Á33.5 cm ( ie 0.036 cbm)
Dz47-63(c45n) series circuit breaker is used in lighting distribution system or motor distribution system for protecting overload and short circuit in the system. This circuit breaker is neoteric in structure, light in weight, reliable and excellent in performance. Its frame and parts adopt plastics of high fire resistant and shockproof. The product, with long life, is mainly used in ac 50hz/60hz single pole 240v or two, three, four poles up to 415v circuit for overload and short circuit protection, as well as for unfrequently switching on&off electric equipment and lighting circuit in normal case. The products comply with iec 60898 & gb10963-1999. Specification: Number of pole: 1, 2, 3, 4pole Rated voltage: 240/415ac Rated current: 1, 3, 6, 10, 16, 20, 25, 32, 40, 50, 63a Breaking capacity: 4.5/6ka Electrical endurance: 10, 000 times
Zn68-12 series of indoor high voltage vacuum circuit breaker is three phase a.C.50(60) hz indoor high voltage distribution equipment with 12kv rated voltage and below. This kind of circuit breaker is characterized by simple construction, strong breaking capability, long life with complete operating functions and convenient maintenance. It is suitable for controlling and protecting transmission and distribution system such as power generation plant and substation, especially used in the field where it is frequently operated.This kind of vacuum circuit breaker can be used for fixed switchgears (xgn2 and ggia), it also can be equipment with truck used for varies panels like jyn2, kyn1 and kyn49 as well as used for reconstruction for old-fashioned oil switchgear.
HKKM2L Series of moulded case circuit breakers HKKM2L Series of Elec. leakage protective breakers is a new model Elec. leakage protective breaker of rated voltage up to 800V, designed and manufactured by the company with advanced international technology and with the aim of satisfying the most advanced market requirements for AC. 50Hz, rated working voltage of 400V and rated working current up to 800A circuit to non-frequently start motor or changeover circuits
Vsm-12 series vacuum circuit breaker
Sell dz47-63 mini circuit breaker Dz47-63 Standard:iec60898 Construction and feature Protection against the overload and short circuit High short circuit capacity Easy mounting onto35 mm din rail The certificate:ccc, ce, cb, s, iram. 43*23.5*17cm 13/12kg 120pcs/ctn
2-wire & 4-wire circuit breakers Description It is an electronic type circuit breaker. The PG circuit breaker range, from 5 to 60 A, 2P (1 Ph + N) or 4P (3 Ph + N), with or without earth leakage protection (300 mA - 500 mA or 650 mA), offers the right product to suit each type of installation. It complies with NFC 61-450; IEC60947-2 French standard. DISJONCTEURS DIFFERENTIELS BIPOLAIRES 5/15A 1 Tension de fonctionnement 220V 2 Calibrage (REGLABLE) 5A, 10A, ou 15A 3 Fr�©quence 50Hz 4 Nombre de p�´les 2 5 Nombre de p�´les prot�©g�©s 1 6 500mA 7 Chute de tension
MCB has the characteristics of advanced structure, reliable performance, high breaking capacity and beautiful appearance. It is mainly used for AC 50HZ or 60HZ, rated voltage 400V or below and rated working current 63A or below. It is used for overload and short-circuit protection of lighting, distribution lines, equipment in office buildings, residential buildings and etc. It can also be used for infrequent on-off operations and conversion of lines.
Mini hydraulics electromagnetic AC DC Toggle Type Circuit Breaker for Equipment Electrical Panel Control trip free 1-50A
Standard: IEC/EN61009-1 GB/T16917.1 Instantaneous trip type: B/C/D The number of poles: 1P+N Rated short circuit breaking capacity (Icn): 6kA Leakage protection trip type: Electronic /Electromagnetic Rated working current (In): 6-40A Rated working voltage (Ue): AC 230 Rated operating frequency: 50/60Hz Rated insulation voltage (Ui): 500V Rated residual operating current : 10/30/100/300mA Life : 4000 Times Type of residual current: A/AC
Standard: IEC/EN60898-1 GB/T10963.1 Instantaneous trip type: Electronic /Electromagnetic The number of poles: 1P+N/3P+N Rated limit short circuit breaking capacity (Inc): 6kA Rated working current (In): 16-63A (can be extended to 125A) Rated working voltage (Ue): AC 230/400V Rated operating frequency: 50/60Hz Rated impulse withstand voltage (Uimp): 4kV Rated residual operating current : 10/30/100/300mA Mechanical/electrical life: 4000/4000 Times Type of residual current : A/AC
Standard: IEC/EN61009-1 GB/T16917.1 Instantaneous trip type: B/C/D The number of poles: 1P+N Rated short circuit breaking capacity( Icn): 6kA Release Type of Leakage Protection: Electronic Rated working current In: 6-40A Rated working voltage (Ue): AC 230V Rated operating frequency: 50/60Hz Rated insulation voltage (Ui): 500V Rated residual operating current : 10/30/100/300mA Life :4000 Times Residual current type: A/AC
Standard: IEC/EN61009-1 GB/T16917.1 Instantaneous trip type: B/C/D The number of poles: 1P+N Rated short circuit breaking capacity (Icn): 6kA Leakage protection trip type: Electronic /Electromagnetic Rated working current (In): 6-40A Rated working voltage (Ue): AC 230/400V Rated operating frequency: 50/60Hz Rated insulation voltage (Ui): 500V Rated residual operating current : 10/30/100/300mA Life: 4000 Times Type of residual current : A/AC
Standard: IEC/EN61008-1 GB/T16916.1 Release Type of Leakage Protection: Electronic /Electromagnetic The number of poles: 1P+N/3P+N Rated limit short circuit breaking capacity (Inc): 6kA Rated working current (In): 16-63A Rated working voltage (Ue): AC 230/400V Rated operating frequency: 50/60Hz Rated impulse withstand voltage (Uimp): 4kV Rated residual operating current : 10/30/100/300mA Mechanical/electrical life: 4000/4000 Times Type of residual current: A/AC
Standard: IEC/EN61009-1 GB/T16917.1 Instantaneous trip type: B/C/D The number of poles: 1P+N/3P+N Rated short circuit breaking capacity (Icn): 6kA Leakage protection trip type: Electronic Rated working current (In): 6-40A Rated working voltage (Ue): AC 230/400V Rated operating frequency: 50/60Hz Rated insulation voltage (Ui): 500V Rated residual operating current : 10/30/100/300mA Life: 4000 Times Type of residual current: A/AC
Standard: IEC/EN61009-1 GB/T16917.1 Instantaneous trip type: B/C/D The number of poles: 1P+N Rated short circuit breaking capacity (Icn): 4.5kA Release Type of Leakage Protection: Electronic Rated working current (In): 6-40A Rated working voltage (Ue): AC 230V Rated operating frequency: 50/60Hz Rated insulation voltage (Ui): 500V Rated residual operating current : 10/30/100/300mA Life: 4000 Times Residual current type: A/AC