Biocompatibility: all patient contact materials are latex free and have been tested About us: 1)high quality and competitive price; 2)standard packing and timely delivery; 3)we supply oem service; 4)sample order and small order are acceptable; 5)the terms of payment: t/t , paypal; 6)the methods of delivery: dhl, ems, ups or fedex (fast and safer); 7)all products are shifting one-year warranty and three months guarantee for replacement; 8)we are a processional manufacturer in mainland china, we have various brands of spo2 sensor, ecg cable and lead wire, ekg cable and lead wire, nibp cuff, ibp cable, temperature probe, holter cable and lead wire, etc; 9)we have ce and iso certificate. We also produce the following items Reusable spo2 sensor Disposable spo2 sensor Spo2 extension cable Ecg cable with leadwires Ekg cable with leadwires, ekg /ecg trunk cable Temperature probe Fetal transducer Ecg electrode Eeg cable Plastic bag with outer carton to protect
ECG Electrodes.
10k series reusable skin temperature probes Specifications 1.3m/10ft, 2.252k resistance 2.12mm disk, 6.3mm mono plug 3.Excellent thermal cycle endurance 4.Stable performance 5.Ce&iso Features: 1.Fast thermal response time constant: 3.5sec max in still air 2.Stable stability and good bio-compatibility 3.High accuracy: tolerance up to ¡¨¤0.02¡ãc 4.Excellent thermal cycle endurance 5.Ce&iso13485 met 6.One year warranty Application: 1.Skine / coelom / body temperature measurement 2.Esophageal / rectal / air / skin chemical sterilisation 3.Disposal or reusable temperature probe for medical application We also produce the following items: Reusable spo2 sensor Disposable spo2 sensor Spo2 extension cable Ecg cable with leadwires Ekg cable with leadwires, ekg /ecg trunk cable Temperature probe Fetal transducer Ecg electrode Eeg cable Ibp cable and transducer Nibp cuff and hose Esu electrosurgical pencil Wire harness Plastic bag with outer carton
Performance characteristics of ultra-high power graphite electrode in 400 arc furnace Our products are characterized by high strength, good electrical conductivity, good thermal shock resistance and low consumption, and are widely used in metallurgical, chemical and mechanical industries. 50 % of the products are sold well in 30 provinces, cities and autonomous regions in China, and 50 % are exported to more than 30 countries and regions including Southeast Asia, Japan and South Korea, Europe, the Americas, and Africa. Technical parameters of ultra-high power graphite electrode in 400arc furnace Specification for the Use of Ultra-High Power Graphite Electrodes in 400 Electric Arc Furnace Points to note for the use of graphite electrodes: 1, wet graphite electrode, dry before use. 2, remove the foam protective cap on the spare graphite electrode hole, check whether the inner thread of the electrode hole is complete. 3, clean up spare graphite electrode surface and hole thread with compressed air without oil and water; Avoid cleaning sand cloth with steel or metal brushes. 4, carefully rotating the connector into the electrode hole at one end of the backup graphite electrode(it is not recommended to load the connector directly into the electrode removed from the furnace), not to collide threads. 5, the electrode hanging equipment(recommended graphite hanging equipment) into the electrode hole at the other end of the backup electrode. 6, when lifting the electrode, loosen the soft material to the bottom of the end of the standby electrode connector to prevent the ground from hitting the connector; Lift the pendant ring with a hook, and the lifting electrode must be stable to prevent the electrode from loosening from the B end or colliding with other fixing devices. 7, hanging the spare electrode to the top of the electrode to be connected, pointing at the electrode hole and slowly falling; Rotate the backup electrode so that the spiral hook rotates with the electrode to drop; When the two electric extremes are 10-20mm apart, the exposed parts of the two ends and joints of the electrode are cleaned again with compressed air; When the electrode is finally completely decentralized, it must not be too violent. Otherwise, due to violent collisions, the electrode holes and joints will be damaged.
Features£º With auto-interpretation function can assist doctor to diagnose Color lcd makes the images more clear for guaranteeing the reliability of the images Designed with technology of digital signal processing and digital isolation Synchronously 12 lead acquisition and printing 3 live leads record of them, using high resolution thermal roll paper for recording ecg waveform, multiple optional digital filter ( including baseline drift filter ), using auto-regulation baseline drift filter which can inhibit any baseline drift , or curb caused by patient's movement and auto- optimize the position for printing Auto measurement / analysis system shows the real-time heart rate which makes it easier for Doctor's diagnosis Can store maximum of 100 patients' ecg data and enable user to replay data analyze and print it From database High-speed usb interface and traditional rs-232 interface are both built¨cin for communicating With computer as well as other devices Data can be received through one of the interfaces and displayed by the software which is also Provided by our company (optional) Specifications: Lcd display: 640¡á480 tft 5.7 inch graphic lcd Lead: standard 12 leads Sampling method: 12 leads synchronously acquisition Cmrr: >80db, > 100db (with ac filter) Sensitivity: auto2.5 5 10 20 mm / mv Paper speed: 6.25 12.5 25 50 mm / s( ¡à 3%) Paper size: 80mm x 30m roll type Recording mode: thermal array printing Power supply: ac: 110-230v (¡à10%) , 50/60 hz¡à1hz 40 va Dc: 14.4v rechargeable li-ion battery Package collocation: Single unit size: 42cm x 26cm x 30cm gross weight: 7 kg 4 pcs/carton dimension : 42cm x 52cm x 60cm gross weight: 27kg Normal collocation: roll paper, patient cable, power cable, limb electrode (limbnip) 4 pcs, chest Electrode ( sucking ball ) 6 pcs, ac electric fuse 2 purchase.
Graphite electrode RP,HP,UHP grade. 1) diameter: 100--600mm 2) grade: rp, hp, shp, uhp 3) packing: wooden crates with steel straps 4) characteristic: A. Superior electric conductivity B. Superior thermal conductivity C. Oxidation & corrosion resistance in high temperature D. Low ash content E. High bending strength F. Reasonable price
Disposable ECG electrodes.
Electrode, ECG, 42mmx50mm, Adult, Foam, Solid Gel 1. Fair average qualiy assured; 2. Comfortable and conveniet; 3. No gel left and non-irritable; 4. Single use only; 5. Recommended for ICU/CCU, Surgery, Emergency.
1. Compatible with Multi-pot system fur serie SC6000, SC6002XL, SC7000, SC9000, Art.Nr. 3368391 (8.2ft). Art.Nr. 5950196(4.9ft) 2. Connected with ECG leadwire, so that to monitor the patient's ECG information, when connected with the monitor; 3. The male connector is made by injection molded, which is durable; And the outer material is made of soft TPU material, which is anti-allergic, anti-corrosion and easy to clean; 4. The products can be disinfected and reused. So it is very cost-effective.
ECG electrode.
ECG gel, also known as electrocardiogram gel or EKG gel, is a conductive medium used in electrocardiography (ECG) procedures to improve the quality of electrical signal transmission between the skin and the electrodes of the ECG machine. Here's more information about ECG gel: Purpose: The primary purpose of ECG gel is to enhance the conductivity and reduce impedance between the skin and the ECG electrodes. This improves the quality and accuracy of the electrical signals detected by the electrodes, resulting in clearer and more reliable ECG readings. Composition: ECG gel is typically a water-based, conductive gel formulated to be non-greasy, non-staining, and hypoallergenic. It may contain ingredients such as water, glycerin, propylene glycol, carbomer, preservatives, and conductivity-enhancing agents. Conductivity: ECG gel is formulated to have high electrical conductivity, allowing it to effectively transmit electrical signals between the skin and the electrodes. This conductivity helps minimize impedance and artifacts, ensuring accurate ECG readings even in challenging conditions. Viscosity: ECG gel is usually designed to have a suitable viscosity that allows for easy application and smooth spreading on the skin. It should be thick enough to stay in place during the procedure but not so thick that it hinders electrode placement or skin contact. Compatibility: ECG gel is compatible with various types of ECG electrodes, including disposable electrodes, reusable electrodes, and adhesive electrodes. It can be used with both standard ECG procedures and specialized cardiac tests such as stress tests, Holter monitoring, and echocardiography. Application: ECG gel is applied directly to the skin at the electrode sites before attaching the electrodes. A sufficient amount of gel should be applied to ensure good contact between the electrodes and the skin surface. Excess gel can be wiped away after electrode placement. Hygiene: ECG gel should be stored in a clean and dry environment to prevent contamination. Disposable single-use packets or bottles with dispensing caps are commonly used to maintain hygiene and prevent cross-contamination between patients. Removal: After the ECG procedure, any remaining gel should be wiped off the skin using a clean, dry cloth or disposable wipe. Residual gel left on the skin can cause discomfort or irritation if not properly removed.
ECG/TMT/CTG papers, medical gels, ultrasound paper, ECG electrodes, plain thermal paper rolls, PFT/spirometry mouthpieces & circular charts .Manufacturer
An ECG bulb, made of silicone, is a component used in certain types of electrocardiogram (ECG) machines. Here's more information about ECG bulbs made of silicone: Material: ECG bulbs made of silicone are designed to be flexible, durable, and resistant to wear and tear. Silicone is chosen for its properties, including flexibility, biocompatibility, and resistance to temperature extremes and chemical exposure. Purpose: The ECG bulb, also known as an ECG electrode or sensor, is a crucial component of the ECG machine. It serves as the interface between the patient's skin and the machine's electrical circuitry, allowing the machine to detect and record the electrical signals produced by the heart. Design: ECG bulbs made of silicone typically have a bulbous or rounded shape with a flat surface that comes into contact with the patient's skin. The silicone material provides a comfortable and secure fit while ensuring good electrical conductivity for accurate signal transmission. Compatibility: Silicone ECG bulbs are designed to be compatible with specific models of ECG machines. They may come in different sizes and shapes to accommodate different electrode configurations and patient needs. Hygiene: Silicone ECG bulbs are often designed for single-use or disposable use to maintain hygiene and prevent cross-contamination between patients. Disposable ECG bulbs help reduce the risk of infection transmission in clinical settings.
Packaging Type Sacks Type Whole Form Packed Shelf Life 2 years Packaging Size Upto 25 kg Benefits Almonds are rich in valuable nutrients for your body. Is It Organic Yes Is It Fssai Certified Yes Added Preservatives No Storage Instructions Store in Cool & Dry Places. Is It Flavoured Non-Flavoured Grade A Product Type Almond in shell Our Almonds are best in quality and are available the best market price.Kagzi almond shell is� extremely soft, which one can easily break with fingers. They are one of the best sources of vitamin E, magnesium, copper, and rich in quality protein, a handful of almonds, contains one-eighth of our necessary required protein. Additional Information: Production Capacity: 10 ton Delivery Time: depends on location and mode of transport Packaging Details: corrugated cases
KINDLY CHECK OUR OTHER POSTS FOR DIP PAY and TTV JET A1 and EN590 IN Fujairah, Rotterdam, Jurong, Bukon, Klang and Houston EN590 available in the following ports: Fujairah: 400,000MT Rotterdam: 600,000MT Jurong: 800,000MT Bukon: 200,000MT Klang: 500,000MT Houston: 700,000MT TANK TO TANK-STANDARD PROCEDURE AGREEMENT (TTT) 1. Buyer confirms Soft Offer and issues an official Irrevocable Corporate Purchase Order (ICPO) along with company registration and Valid Passport Copy. CIS on buyer's company letterhead along with TANK STORAGE AGREEMENT (TSA) 2. Seller issues commercial invoice of products in tank at port, buyer signs and returns commercial invoice with acceptance letter stating to adhere to seller procedure 3. Seller provides buyer with the below listed PPOP: A. Tank to Tank Injection agreement (TTIA) B. Product Passport (product analysis report) C. Irrevocable Commitment Letter to Supplier D. Statement of Product Availability 4. Buyer returns signed Tank to Tank Injection agreement (TTIA) with ATV to verify from buyer's Tank Farm which means buyer has storage facilities in favor of buyer to receive product 5. Seller issues injection schedule to sign and seal from buyer Tank Farm and Seller commence injection of the product into buyer's tank. 6. The seller issues the following POP documents to the buyer; the buyer performs a Dip test on the product if needed and makes payment for the total value of the product injected into the tank via MT103 -TT: (a) SGS report for quality and quantity at shore tank not older than 48 hours (b) Product Certificate of Origin (c) Tank storage receipt with full GPS coordinates (d) Unconditional Dip Test authorization letter (e) Authorization to sell and collect (f) NCNDA-IMFPA agreement (g) Q&A (i) Company Registration Certificate 7. (NCNDA/IMFPA) will be signed, within 24 hours of giving POP document 8. Seller transfer title ownership to buyer with all exportation documents required of buyer for the transaction. 9. Upon conclusion of first lift transaction seller pays all intermediaries involved in the Transaction and proceeds with the signing of contract with Buyer. Current Prices and commissions: EN590 A) FOB DIP PAY (TTT) USD530MT B) FOB (TTT_TTV) USD510MT JET FUEL A1 A) FOB (TTT_TTV) USD70 B) FOB DIP PAY (TTT) USD80 BUYER SIDE COMMISSIONS: EN590 DIP PAY (TTT) USD15 TTT/TTV: USD20 JET A1: TTT/TTV: USD2 DIP PAY(TTT) USD2
High-conductivity gel for electrocardiography (ECG) is a specialized conductive gel used to improve electrical conductivity between the skin and ECG electrodes during cardiac monitoring procedures. Here's more information about high-conductivity gel for ECG: Purpose: The primary purpose of high-conductivity gel is to reduce impedance and improve the transmission of electrical signals between the skin and the ECG electrodes. This ensures accurate and reliable recording of the heart's electrical activity during ECG testing. Composition: High-conductivity gel is typically water-based and contains conductive agents that enhance its electrical conductivity properties. Common ingredients may include water, glycerin, propylene glycol, carbomer, electrolytes (e.g., sodium chloride), and preservatives. Conductivity: High-conductivity gel is formulated to have superior electrical conductivity compared to standard ECG gels or other electrode contact solutions. This allows for better signal quality and minimizes the risk of artifacts or interference during ECG recordings. Viscosity: The gel's viscosity is designed to be suitable for easy application and spreadability on the skin. It should be thick enough to adhere to the skin and maintain contact with the electrodes but not too thick that it hinders electrode placement or skin contact. Non-Staining: High-conductivity gel is typically formulated to be non-greasy and non-staining, ensuring minimal residue on the skin after use. This helps maintain patient comfort and prevents staining of clothing or bedding. Compatibility: High-conductivity gel is compatible with various types of ECG electrodes, including disposable electrodes, reusable electrodes, and adhesive electrodes. It can be used with standard ECG machines and Holter monitors. Application: Before applying the gel, the skin should be cleaned to remove any oils, lotions, or dirt that may interfere with electrode contact. A thin layer of high-conductivity gel is then applied to the skin at the electrode sites before attaching the electrodes. Hygiene: High-conductivity gel should be stored in a clean and dry environment to prevent contamination. Disposable single-use packets or bottles with dispensing caps are commonly used to maintain hygiene and prevent cross-contamination between patients. Overall, high-conductivity gel plays a crucial role in ensuring optimal electrode-skin contact and signal quality during ECG testing. Its superior conductivity properties make it an essential accessory in cardiac diagnostic procedures, allowing for accurate interpretation of the heart's electrical activity.
ECG: 12-lead resting PC-ECG with auto interpretation VCG: Vector-cardiograph with auto interpretation Hardware Features: High sampling rate of 1000Hz Digital filter system Applying anti-baseline-drift technology ensuring the stability of ECG baseline Wilson and Frank hookup system Meet the international standard of IEC60601-1 Easy operation and perfect printout Diagnosis of coronary heart disease Perfect time domain, frequency domain and non-linear HRV analysis Perfect ECG database management system Specification for PC-ECG: Sample rate: 1000Hz, simultaneous 12 leads recording Resolution:12bit Power: 5.0V (DC) Patient Insulation: 4000V AC Defibrillation Protection: Built-in box Digital resolution: 2V Frequency response: 0.05-250 Hz Common mode rejection: >90dB Input impedance: >10MΩ Time constant: 3.2 s Max electrode potential: ±300mV DC Dynamic range: ±10mV Isolate voltage: 4000V Current leak:
ECG disposable electrodes, preparing adult ECG electrodes, stress ECG electrodes.Iron, copper, scraps sellers
Specifications: Measurement: 12-lead resting ECG ECG analysis frequency: 500 samples per second Digital sampling speed: 8000 samples per channel and second ECG visualization: Real-time graphic representation Acquisition mode: Real-time acquisition (delay between channels < 10us) Dynamic range: 400mV Resolution: 24 bits per channel (< 1uV) Frequency specifications: Adaptative line frequency filter: 50Hz and 60Hz CMRR: > 115dB Input impedance: > 100Mohms with defibrillation protection Current leaks in patient: < 10uA Initial stabilization time: 3s Software: Operative System: PC: Windows 7 or later, macOS, Android 4 or later, iOS (iPhone/iPad) 8 or later Patient information: Name, identificator, birth date, gender and comments Report information: Patient, physician, date, time and diagnosis Device information: Battery level and electrodes status DICOM compatibility: C-ECHO test, C-STORE operation and Modality Worklist SCP query Reports: Number of leads: 6 and 12 leads Operation modes: Monitoring: 0.67 Hz ~ 40 Hz Diagnostic: 0.05 Hz ~ 150 Hz Raw data: no filter Vertical resolution: 10mm/mV Horizontal resolution: 10, 25 and 50mm/s Export: Email (DICOM and PDF files), DICOM C-STORE and ECG Cloud Analysis: Heart rate, QRS annotations and normal/abnormal classifier Heart rate interval: 20 bpm to 240 bpm
Disposable ECG electrodes, esu pads, esu pencils .Manufacture