HVT-SM Sealed Metering System
HVT-Halmi Venturi Flow Meters
Coating thickness meter cm-8823 Application: Product synopsis Measurement range 0200um/500um/1000um/15000um Resolution 0.1/1 Tolerance +(13%n) or +2um Power supply 4x1.5v aa(um-3)battery Dimension 161x69x32
Tachometer Eatures: Measuring rpm is safe & accurate without attachment to object. Wide measuring range & high resolution. Digital display gives exact rpm with no guessing or errors. Used the exclusive micro-computer lsi-circuit and crystal time base to offer the high accuracy measurement & fast measuring time. The last value/max. Value/min. Value will be automatically stored in memory and can be displayed by turn. The use of durable, long-lasting components, including a strong, light weight abs-plastic housing assures maintenance free performance for many years. Product synopsis Model: dt Measuring range: rotative velocity laser . - r/min Contact . - r/min Laser tach detecting distance: - mm Accuracy: f+( . %n+ d) Resolution: . / . / Memory: max/min/last value Power supply: x . V aa (um- ) battery Battery indicator: low battery indicator Dimensions: x x mm Weight (not including probe): g
DIGITAL MULTIMETER Range Accuracy Dc voltage 200mv-500v (0.5%+2dgt) Ac voltage 200-500v (1.2%+10dgt) Dc current 200µa-10a (1%+2dgt) Resistance 200 +-2000k+ (0.8%+2dgt) Diode test Yes Transistor test Yes Power supply 12v battery a12 Maximum display 1999 Products size 100,-50,-20mm Product net weight 58g Standard accessories Test lead, battery, manual
Digital multimeters DC V 400mV/4V/40V/400V/1000V Basic accuracy 0.3%+5d AC V 400mV/4V/40V/400V/700V Basic accuracy 0.75%+10d DC Current 40mA/400mA/4A/20A Basic accuracy 1.2%+10d AC Current 40mA/400mA/4A/20A Basic accuracy 1.2%+10d Resistance 400+/4K+/40K+/400K+/4M+/40M Basic accuracy 0.5%+10d Capacitance 40nF/400nF/4uF/40uF/100uF Basic accuracy 2.0% Data hold Min/Max/Avg. Measurement Peak Hold Continuity test Diode test Low battery sign Backlight Signal output Frequency Counter 0.5Hz-45MHz Basic Accuracy 0.1%+5d Automotive RPM 0-12000RPM Duty Cycle 0-100% Dwell 2/4/5/6/8/12 Logic Analyzer 2/4/5/6/8/12 Power Source 6 -1.5V AA or 6 -1.2V A
Wired Solution for Apartment (RS232/RS485) Wried and wireless Solution for Independent house (RF Base) Walk/Drive by Solution (Bluetooth) Bluetooth 5.0 Drop by Drop Water Management Solution
Prepaid meters are now, The government is also taking initiative and making policies to make it happen. Commercial establishments like offices, retail, industrial, multifamily, malls, complexes can install prepaid meters. With Adwards Intellitech Pvt Ltd you don't have to bargain, we provide Low cost prepaid meters for all commercial establishments. Our prepaid meter is flexible in adapting to the ever-changing requirements and conditions.
Place of Origin: Shanghai, China (Mainland) Brand Name: GN Model Number: CX-GMF Function: Multiple Operation: Easy Application: Widely Maintenance: Easy and little Technology: Advanced Standard: ISO and CE Working: Stable and Reliable Warranty: One year Exported: More 80 countries Experience: More 20 years
Digital Grain Moisture Meter Model : GA-271 Range : 3.5 to 40% Accuracy :±0.2% Display : Three Seven Segment FND Principle : Resistance Measurement Power : Six 9v Dry Cells or 230 Volts 50 Hz AC through Adaptor Temperature : Automatic Size : 300x170x260 mm. approx. Weight : 9.5 Kg approx. without accessories.
MF5000 series Gas Mass Flow Meters General description MF5000 series mass flow meters are specially designed for small pipe flow monitoring and feature an extremely low pressure loss compared to the traditional by-pass thermal mass flow meters in this application scope. The accuracy of the meters are generally (1.5+0.5FS)% or better depending on the requests. The meters can work at an environment of -20 to 60'C and pressure up to 1.5 MPa. Applications include semiconductor gas process monitoring and control, hospital oxygen gas monitoring, etc. MF5000 Series have 5 designs, with model number: MF5003/MF5006/MF5008/MF5012/MF5019. MF5000 series Gas Mass Flow Meters Features and Applications - Highly sensitive, measuring as low as 8 mm/sec, and as high as 65 m/sec with a single assembly - Directly sense mass flow using thermal mass flow principle - Proprietary MEMS sensor package design for better reliability - Standard 12 ~ 24 Vdc power supply - Low pressure loss forreducing energy cost - Industrial standard Modbus protocol for easy networking and remote control MF5000 series Gas Mass Flow Meters Specifications * â??Accuracy: (1.5+0.5 FS)% * Environment: - Temperature: -20 ~ +60'C; - Humidity: < 95%RH (No icing or condensation ) * Flow channel: 3 ~ 19 mm * Display: Flow rate and accumulated flow * Interface: 4 ~ 20 mA; RS485; Pulse * Calibration: Air @ 20'C; 101.325 kPa
Vasthi uses heated probe to collect the sample from the sample line, it will maintain constant temperature and removes the dust and mist from the sample gas. This gas sample passes through electrically heated tube to cooler. It will remove the vapour content and cools the gas sample to 5áµ?c dew point range and this sample gas goes through the filter that eliminates the dust particle remaining and finally sensor senses and gives the exact readings in syngas analyzer.
This instrument adopts the pulse xenon lamp as light source and the ultraviolet optical fiber spectrometer as detector is capable for real-time gathering of absorption spectrum of water pollutants ranging from 200nm to 800nm and real-time analysis of the content of water pollutants by means of chemometric algorithm technology. Optical path as shown below.For more information.
Description - It Use A Magnetic Field Applied To The Metering Tube, Which Results In A Potential Difference Proportional To The Flow Velocity Perpendicular To The Flux Lines. Origin - Korea Size - 10a ~ 900a "packaging Details (w*d*h)/mm" - 600*500*500 Weight(kg) - 6 ~ 31 FOB ($) - " Retail Price + (shipping Cost) " MOQ - 1 Set Note - All The Product Information May Be Changed Depending On The Specification.
Description - It Is A Type Of Flow Meter That Requires Fluid To Mechanically Displace Components In The Meter In Order For Flow Measurement. Origin - Korea Size - 25a ~ 300a "packaging Details (w*d*h)/mm" - 500*300*200 Weight(kg) - 13 ~ 120 Fob ($) - " Retail Price + (shipping Cost) " MOQ - 1set NOTE - All the product information may be changed depending on the specification.
Top mounted magnetic float liquidometer Product name:high temperature and high pressure type magnetic flap level gauge Product code:15644-178 Update time:2015.08.25 Views:501 Processing custom origin:in kaifeng Accuracy:+ / - 10 mm Measuring range:0.3-6 m (standard), up to 15 meters Temperature range:0-485 Pressure range:vacuum - 42 mpa The process connection:flange/spool/thread Protection grade:ip68 Display type:vacuum glass tube packaging, magnetic shows
MF5806 Series Digital Oxygen Flow Meters General description MF5806 series oxygen flow meters are specially designed for hospital individual oxygen therapy applications. it provides precise measurement of instant oxygen intake rate and accumulated oxygen dosage for the individual oxygen delivery system. the design provides low power consumption that make it possible for operation on battery when power is an concern. themeter can be directly connected to the central station via RS485 that can provide remote monitoring and control which will reduce the risk of oxygen over dosing. MF5806 Series Digital Oxygen Flow Meters Features and Applications - Plug-and-paly hospital oxygen deliver design for easy usage - Mass flow technology provide precise instant rate and accumulated dosage - Historical data storage and retrieval - Password protected access - Instant rate and accumulated dosage alarm - Excellent repeatability and accuracy - Low power design with stand-alone operation by battery MF5806 Series Digital Oxygen Flow Meters Specifications * Flow Range: 0 ~ 10 SLPM * Accuracy: �±(1.5+0.5 FS)% * Repeatability: 0.5% * Respâ??onse Time: 2 sec * Digital Output: RS485 (Modbus) * Working Pressure: 0.1 ~ 0.6 MPa * Working Temperature: -10 ~ +55'C
Applications: *Measture the cast iron thickness,aluminum thickness,quartz glass thickness,PVC thickness,PE thickness,red copper thickness etc. Details: Case Material: Aluminum Alloy Operating Principle: Ultrasonic Measuring Range (metric / Imperial):0.75~400 mm ( 45 # steel, Depend on Probe ) Sound Velocity: 500~9,990 m/s Resolution:0.01 mm / 0.1 mm Accuracy: � (0.5%n + 0.05) For more details,please do not hesitate to contact us.Thank you!
Esd simulator (electrostatic discharge generator or electrostatic gun) is in full compliance with iec 61000-4-2, en61000-4-2, iso10605, gb/t17626.2, gb/t17215.301 and gb/t17215.322. The esd generator is designed for the assessment of electrical and electronic equipment to withstand esd performance. Esd61000-2/esd61000-2a has lcd display in both english and chinese, they equipped with an infrared remote control which can allow you do the test in some special place.
Specification: Detection frequency range: 9khz~30mhz (kh3961) or 9khz~300mhz (kh3962) Frequency stability: 1x 10-6 Frequency resolution: (9khz~150khz) 30hz; (150khz~30mhz) 1khz Test tolerance:2 db Measure and detection method: pk, qp and av range from 20db|¨¬v to 140db|¨¬v Test time: setting by customers Frequency scanning step length: 20hz~2mhz Sweep bandwidth: 200hz; 9khz; 120khz