EPGT tube stands on EDTAK2 with Gel Tube. It is coated with lithium heparin and inside the tube a barrier Gel presented at the bottom. Product Feature they are normally made of glass and plastic. In addition, the plastic tube includes PET, PP and PS. Product Specification/Models 1ml 13í-75mm VP10041S 2ml VP20031S 3ml VP30031S 4ml 13í-100mm VP40042S 5ml VP50032S 6ml VP60032S 8ml 16í-100mm VP80043S 9ml VP90043S Application. Through centrifugation, the separation gel can form a barrier between plasma and blood cell and totally separate them. Clinical specimen obtained is suitable for analysis of virus capacity and molecular diagnostics of undiluted plasms. Other Information We are professional manufactory dealing especially with the export of blood collection kits. We are in a position to accept orders according to the customer's samples. 100pcs/tray 1200pcs/carton
Product feature They are normally made of glass and plastic. In addition, the plastic tube includes pet , pp and ps. Product specification/models 3ml 13íß75mm vp30011s 4ml vp40011s 5ml vp50011s 3ml 13íß100mmvp30012s 4ml vp40012s 5ml vp50012s 6ml vp60012s 8ml 16íß100mmvp80013s 9ml vp90013s Application It is used for collecting blood specimen for biochemistry and immunology tests, especially fast in blood coagulation. Other information We are professional manufactory dealing especially with the export of blood collection kits. We are in a position to accept orders according to the customer's samples. 100pcs/tray 1200pcs/carton
Ssgt tube stands on clot activator with gel tube. It is coated with clot activator and inside the tube a barrier gel presented at the bottom. Product feature They are normally made of glass and plastic. In addition, the plastic tube includes pet, pp and ps. Product specification/models 3ml 13íß75mm vp30021s 3.5ml vp35021s 3ml 13íß100mm vp30022s 4ml vp40022s 5ml vp50022s 7ml 16íß100mm vp70023s 8ml vp80023s Application It is used for clinical biochemistry and immunology. The obvious characteristic of ssgt tube is used to obtain high-quality plasma specimen for medical laboratories. Other information We are professional manufactory dealing especially with the export of blood collection kits. We are in a position to accept orders according to the customer's samples. 100pcs/tray 1200pcs/carton
Product specification/models Infant blood collection tube: 8*45mm Color: red, yellow, lavender, green, black, gray, blue. Application It's used for children's blood collection Other information We are professional manufactory dealing especially with the export of blood collection kits. We are in a position to accept orders according to the customer's samples. 100pcs/tray 1200pcs/carton
Butterfly Blood Collection Set. EO STERILIZATION Single Blister Package Specification: 21G, 23G, 25G, CUSTOMIZED MOQ 100K Sterile Pack, Single use only Color coded for easy identification of needle sizes Ultra-sharp needle tip minimizes patient discomfort More comfortable double wings design, easy operation Customized sizes available 510K approved CE approved ISO
Hemodialysis Blood Tubing Set Product Code: MED 171 Specifications: Sterile, medical grade paper pouch with standard plastic film Description Blood tubing set has been specially designed for the patient to connect external systems which extracts patientâ??s blood to the dialyzer and then returns patientâ??s blood from the dialyzer. Consists of 2 parts â?? Arterial and Venous Line-use during dialysis and attached fistula and dialyzer. Unique chambers reduce foaming, increase air removal and does not trap EPO (Erythropoietin) compliant material of transducer protectors. This helps in ensuring secure Machine fit and less incidence of wet out. Color coded ergonomic clamps and dialyzer connectors with tethered caps that seal tightly for disposal. Kink resistant tubing dandles easily and ensures fast priming
Vacuum Blood Collection Tubes.
Blood Collection Tubes Additives.
Vacuum Blood Collection Tube..
Cutter, syringe, strips, needles, thermometer, cannula, glucometer, harmonic focus shears, ace circulation, adhesive mini wrap, blades, blood collection tube, blood pressure monitor, nutella, onion, dried apricot, bioderma, sensibio.
EDTA salts (ethylene diamine tetra acetic acid) are used for the anticoagulation of whole blood for haematological investigations as the cellular components of the blood are particularly well preserved by EDTA. It works as an anticoagulant as it forms complexes with metal ions such as calcium, therefore inhibiting the coagulation cascade. Anticoagulation with EDTA is irreversible. The EDTA concentration in tubes is LYBCON Vacutainer 1.8mg per ml of complete blood when the fill level is correct, as recommended by the ICSH (International Council Society of Haematology) and the CLSI (Clinical and Laboratory standards institute). The institutes recommend dipotassium EDTA salt (K EDTA) for 2 haematological investigation. K EDTA is used in 2 LYBCON Vacutainer tubes in spray dried form.
Micro Collection Tube Micro Collection Tube is mainly used for peripheral blood collection. It is specially suitable for small children and geriatric patient. The inner surface has an excellent hemorepellency where it is necessary for a good preparation of high quality blood sample. Item GD005A , Specification: Micro Collection tube, Plain, 0.5ml , Item GD005CA , Specification: Micro Collection tube, Clot Activator 0.5ml , Item GD005EK3 , Specification: Micro Collection tube, EDTA K3, 0.5ml , Item GD005EK2 , Specification: Micro Collection tube, EDTA K2, 0.5ml , Item GD005LH , Specification: Micro Collection tube, Heparin Lithium, 0.5ml , Item GD005SH , Specification: Micro Collection tube, Heparin Sodium, 0.5ml , Item GD005SFH , Specification: Micro Collection tube, Heparin Sodium + Sodium Fluoride, 0.5ml , Item GD005SGC , Specification: Micro Collection tube, Gel + Clot Activator, 0.5ml , Item GDNM005A , Specification: Micro tube (High Type ) 0.5ml Plain 0.5ml, Item GDNM005CA , Specification: Micro tube (High Type ) 0.5ml Clot activator 0.5ml, Item GDNM005EK3 , Specification: Micro tube (High Type ) 0.5ml EDTAK3 0.5ml, Item GDNM005EK2 , Specification: Micro tube (High Type ) 0.5ml EDTAK2 0.5ml, Item GDNM005LH , Specification: Micro tube (High Type ) 0.5ml Gel 0.5ml, Item GDNM005SGC , Specification: Micro tube (High Type ) 0.5ml Gel 0.5ml, Item GDNM005SFH , Specification: Micro tube (High Type ) Glucose ( Heparin sodium,/ Sodium Fluoride) 0.5ml
Vacuum blood collection tube assembly machine.Blood collection tube manufacturing skills, technical support
Specification:50ml,60ml,100ml Unique labeling urine collection hole makes urine collecting and transferring convenient sanitary and safe. This container can prevent outer substance and bacteria contaminating urine specimen and urine spilling, which maximally avoids the risk of contacting pathogenic urine specimen by patient and medial people. The label is easy to tear and re-seal. Packing:500pcs/ctn Weight:G.W.7.8kg/ctn, N.W.6.0kg/ctn Dimension:595mm*490mm*400mm
Pro-coagulation tube with orange stopper. Clot activator is prefilled for quik serum measurement and immunology test. (glass & plastic 12/13*75,12/13*100, 15/16*100) Packing:100pcs/plate,1200pcs/ctn Weight:G.W.12.5kg/ctn,N.W.11.5kg/ctn Dimension:470mm*370mm*215mm
SERUM TUBES In order to obtain serum samples from plastic tubes, the tube must have coagulation activator added. As the plastic suface alone is insufficient to trigger the coagulation within an acceptable time, LYBCON VACUTAINER serum tubes have silica particles added for this purpose. CLOTTING TIMES The recommended minimum time for the coagulation of samples from patients who have not been treated with anticoagulants is 30- 45 minutes for serum (red).
LYBCON Vacutainer GEL-SST Advance tubes During the centrifugation of the LYBCON Vacutainer GEL-SST Advance tubes, an inert LYBCON Vacutainer gel separates the serum and the blood clot preventing the contamination of the serum from the separated cellular components. For example, the serum for certain analytes such as potassium, phosphorus and glucose must be separated from the cells within a few hours - otherwise the results will be significantly distorted. Using LYBCON GEL-SST Advance tubes routine analyses in clinical chemistry such as potassium and glucose are still stable after a week of storage at 2-8 C. Clinical evaluations of special chemistry demonstrate a high degree of analyte stability with the acrylic gel in the LYBCON GEL-SST Advance, with detection of >90% of the therapeutic drugs and other special analytes(proteins/peptides, steroids and vitamins) tested. As a result of the type of gel used in the GEL-SST Advance tubes, LYBCON Vacutainer short centrifugation times of 5 minutes at 3000g can be achieved. The stability of the gel barrier is a distinct advantage during transport and storage. The main advantages of gel tubes versus non-gel tubes are: Stable barrier between serum and clotted blood, therefore better analyse stability. Better sample quality. Optimisation of the work flow: Short centrifugation time, sample processing and archiving in the primary tube. No possibility of misidentification due to the use of secondary tubes. CLOTTING TIMES The minimum recommended coagulation time for GEL-SST Advance tubes for patients who have not LYBCON Vacutainer received anticoagulation treatment is 30 minutes. CENTRIFUGING CONDITIONS 1600-2000g for 10 minutes MIXING RECOMMENDATION Serum Separation Tubes should be gently inverted 180 and back 6-8 times. EFFECTS OF TEMPERATURE LYBCON Vacutainer GEL-SST Advance should be stored at 4-25C and protected from direct sunlight during storage. Cooling of the tube by or during centrifuging can affect the movement capability of the gel. The optimum separation of serum and coagulated blood is achieved at a temperature of 20-25C. Serum Separation Tubes should be gently inverted 180 and back 6-8 times. CLOT ACTIVATOR LYBCON Vacutainer GEL-SST Advance tubes contain silica particles. SPECIFICATION Specimen: Serum Additive: Gel & Clot Activator Cap color: Dark yellow Tube Size: 13x75mm Draw Volume: 3.5mL Max. draw volume Tolerance: ±10%
SODIUM CITRATE Trisodium citrate is used as an anticoagulant for coagulation investigations. It works as an anticoagulant as it forms complexes with metal ions such as calcium inhibiting the coagulation cascade. Anticoagulation with trisodium citrate is reversible. LYBCON Vacutainer Citrate tubes contain buffered citrate in accordance with recommendations: 0.105 M or 0.109 M of buffered trisodium citrate solution, equivalent to 3.2% trisodium citrate The blood to additive ratio is 9:1. The citrate solution in the acts as LYBCON Vacutainer a buffer. Therefore, no additional buffer substances are added as these can adversely affect laboratory analysis. LYBCON Vacutainer Citrate tubes are also suitable for carrying out special test procedures such as the platelet function test PFA-100. Special tubes and the associated additional costs are therefore unnecessary. FILL LINE MARKING The significance of the correct ratio of blood to additive for coagulation samples is well documented. The correct fill amount is critical for correct coagulation analysis. All LYBCON Vacutainer coagulation tubes have a mark indicating the minimum fill level. CENTRIFUGING CONDITIONS For coagulation analysis different plasma specifications can be obtained from the citrated blood. Platelet rich plasma:150-200g for 5 minutes at 18-25 C Platelet poor plasma:2000-2500g for 10-15 minutes at 18-25 C Platelet free plasma: >3000g for 15-30 minutes at 18-25 C MIXING RECOMMENDATION Citrate tubes should be gently inverted 180 and back 3-4 times. SPECIFICATION Specimen: Plasma or Whole Additive: Sodium citrate 3.2% or 3.8% (9NC) Cap color: Blue Tube Size: 13x75mm Draw Volume: 1.8mL, 2.7mL Max. draw volume Tolerance: ±10%
The tubes are designed for blood The tubes are designed for blood LYBCON Vacutainer sedimentation without the use of sedimentation pipettes. The blood is taken directly into the tubes and LYBCON Vacutainer turned end-over-end 8-10 times. Immediately before the tubes are placed in the stand for measurement, LYBCON Vacutainer the tubes must be mixed again. After one or two hours the results are read. The stand holds a LYBCON Vacutainer maximum of 10 tubes and has a height Lybcon adjustable zero mark. The measurement results achieved correspond to the Westergren method. MIXING RECOMMENDATION ESR (Erythrocyte Sedimentation Rate) tubes should be gently inverted 180 and back 8-10 times. SPECIFICATION Specimen: Whole Additive: Sodium citrate 3.8% (4NC) Cap color: Black Tube Size: 13x75mm Draw Volume: 1.6mL, 1.8mL Max. draw volume Tolerance: ±10% sedimentation without the use of sedimentation pipettes. The blood is taken directly into the tubes and LYBCON Vacutainer turned end-over-end 8-10 times. Immediately before the tubes are placed in the stand for measurement, LYBCON Vacutainer the tubes must be mixed again. After one or two hours the results are read. The stand holds a LYBCON Vacutainer maximum of 10 tubes and has a height LYBCON Vacutainer adjustable zero mark. The measurement results achieved correspond to the Westergren method. MIXING RECOMMENDATION ESR (Erythrocyte Sedimentation Rate) tubes should be gently inverted 180 and back 8-10 times. SPECIFICATION Specimen: Whole Additive: Sodium citrate 3.8% (4NC) Cap color: Black Tube Size: 13x75mm Draw Volume: 1.6mL, 1.8mL Max. draw volume Tolerance: ±10%