The adp9000 offer of configurations for differential, gas, absolute vacuum liquid-level measurements including integrated solutions for pressure, level and flow. Features Updating time of output current in 200 ms Improved performance, increased accuracy, greater stability Two years stability of 0.2% 0.075% accuracy Parameter setting by local keypad or rs485 communication port 4-20 ma output plus direct digital hart communication Automatic zero calibration by push button Explosion proof and weather proof housing Specification Process fluid: liquid, gas of vapor Application: differential pressure, gauge pressure, absolute pressu Measuring range:0 - 0.25 kpa ~ 0 - 1.5 kpa ( minimum ) 0 - 4.0 mpa ~ 0 - 25.0 kpa ( maximum ) Accuracy:+/- 0.75% of span Material: Flange/adapters: stainless steel 304 / stainless steel 316 Drains/vents: stainless steel 304 / stainless steel 316 Diaphragms: stainless steel 316l / hastelloy b /hastelloy c / monel / tantalum Wetted o-rings: Buna n / viton / ptfe Bolts & nuts: carbon steel / stainless steel 316 Mounting bracket: carbon steel / stainless steel 304 / 316 Name / tag plate: stainless steel 304 / stainless steel 316 Converter housing: low copper cast aluminum alloy with polyurethane, light blue paint Enclosure:ip67 ( standard )/intrinsically safe eex ia iic t5 ( standard )/ex Standard
Description of 4-20ma pressure transmitter with display : YA-SED1 type pressure transmitter is design for the site with bad environment. Adopt silicon piezoresistive sensor, micro amplifier processing circuit. With the characteristic of vibration resistance and good impact resistance, high precision, stability. Widely used in pressure and level measurement and process control of petroleum, chemical and metallurgical, food industries. Features of 4-20ma pressure transmitter with display : Stainless steel high strength shape structure Shape structure diversification, can be customized Strong anti-interference, good long-term stability LED, LCD header display can be selected Corrugated cardboard boxes outer and foam paper inner packing size: 4x5x14cm
Rosemount 2088 Gage and Absolute Pressure Transmitter Specifications Warranty Up to 5-year limited warranty Rangedown Up to 50:1 Communication Protocol 4-20 mA HART, 1-5 V Low Power HART Measurement Range Up to 4,000 psig (275,8 bar) Gage, Up to 4,000 psia (275,8 bar) Absolute Process Wetted Material 316L SST, Alloy C-276 Diagnostics Basic Diagnostics Certifications/Approvals NSF, NACE, hazardous location, see full specs for complete list of certifications Features Local Operator Interface (LOI) features straightforward menus and built-in configuration buttons for ease-of-use Factory-assembled and leak-checked integral manifold and remote seal solutions deliver a quick start-up Available protocols include 4-20 mA HART and 1-5 Vdc HART Low Power for application flexibility Lightweight, compact design allows for easy installation Normal Models 2088G1S22A1B4E5M5 2088G2S22A1B4E5M5 2088G3S22A1B4E5M5 2088G4S22A1B4E5M5 2088G1S22A1B4E5M5 2088G1S22A1B4E5M5 2088G1S22A1B4E5M5 2088G1S22A1B4E5M5 2088G1S22A1B4E5M5 2088G1S22A1B4E5M5 2088A1S22A1B4E5M5 2088A2S22A1B4E5M5 2088A3S22A1B4E5M5 2088A4S22A1B4E5M5 2088AS22A1B4E5M5 2088AS22A1B4E5M5 2088AS22A1B4E5M5 2088AS22A1B4E5M5 2088AS22A1B4E5M5 2088AS22A1B4E5M5 2088G1S33A1B4E5M5 2088G2S33A1B4E5M5 2088G3S33A1B4E5M5 2088G4S33A1B4E5M5 2088G1S33A1B4E5M5 2088G1S33A1B4E5M5 2088G1S33A1B4E5M5 2088G1S33A1B4E5M5 2088G1S33A1B4E5M5 2088G1S33A1B4E5M5 2088A1S33A1B4E5M5 2088A2S33A1B4E5M5 2088A3S33A1B4E5M5 2088A4S33A1B4E5M5 2088A1S33A1B4E5M5 2088A1S33A1B4E5M5 2088A1S33A1B4E5M5 2088A1S33A1B4E5M5 2088A1S33A1B4E5M5 2088A1S33A1B4E5M5 2088G1S2BA1B4E5M5 2088G2S2BA1B4E5M5 2088G3S2BA1B4E5M5 2088G4S2BA1B4E5M5 2088G1S2BA1B4E5M5 2088G1S2BA1B4E5M5 2088G1S2BA1B4E5M5 2088G1S2BA1B4E5M5
Rosemount 2051 Coplanar Pressure Transmitter Specifications Warranty Up to 5-year limited warranty Rangedown Up To 100:1 Communication Protocol 4-20 mA HARWirelessHART FOUNDATION� Fieldbus, PROFIBUS 1-5 V Low Power HART® Measurement Range Up to 2000 psi (137,9 bar) Differential, Up to 2000 psig (137,9 bar) Gage Process Wetted Material 316L SST, Alloy C-276, Tantalum Diagnostics Basic Diagnostics Certifications/Approvals SIL 2/3 certified to IEC 61508 by an independent 3rd party, NSF, NACE hazardous location, see full specs for complete list of certifications Features Performance up to 0.05% of span accuracy Patented coplanar technology allows direct mounting to pressure, flow or level solutions for installation flexibility Delivered fully assembled to manifolds, diaphragm seals or primary flow elements for straightforward installation Local Operator Interface offers easy-to-use menus and built-in configuration buttons for streamline commissioning SIL 2/3 certified to IEC 61508 (via 3rd party) and prior-use certificate of FMEDA data for safety installations Normal Models 2051CD0A02A1AB1H2L4M5 2051CD0A02A1AB1H2L4M5K5 2051CD1A02A1AB1H2L4M5K5 2051CD2A02A1AB1H2L4M5K5 2051CD3A02A1AB1H2L4M5K5 2051CD4A02A1AB1H2L4M5K5 2051CG5A02A1AB1H2L4M5K5 2051CG1A02A1AB1H2L4M5E5 2051CG2A02A1AB1H2L4M5E5 2051CG3A02A1AB1H2L4M5E5 2051CG4A02A1AB1H2L4M5E5 2051CG5A02A1AB1H2L4M5E5 2051CG1A02A1AB1H2L4M5I5 2051GP1A2B21AB4M5 2051GP2A2B21AB4M5 2051GP3A2B21AB4M5 2051GP4A2B21AB4M5 2051GP5A2B21AB4M5 2051GP1A2B21AB4M5K5 2051GP2A2B21AB4M5K5 2051GP3A2B21AB4M5K5 2051GP4A2B21AB4M5K5 2051GP5A2B21AB4M5K5 2051GP1A2B21AB4M5E5 2051GP2A2B21AB4M5E5 2051GP3A2B21AB4M5E5 2051GP4A2B21AB4M5E5 2051GP5A2B21AB4M5E5 2051GP1A2B21AB4M5I5 2051GP2A2B21AB4M5I5 2051GP3A2B21AB4M5I5 2051GP4A2B21AB4M5I5
Rosemoun 3051S Coplanar Pressure Transmitter Introduction The Rosemount 3051S Coplanar Pressure Transmitter is designed with the patented Coplanar technology and is the no-equal solution for pressure, flow and level measurements. This scalable platform seamlessly integrates with manifolds, primary elements and seal solutions and optimizes performance for accurate differential, gage and absolute pressure measurements. With the SuperModule platform, this transmitter resists overpressure and line pressure effects to maintain unmatched performance. Specifications Warranty Up to 15-year limited warranty Rangedown Up to 200:1 Communication Protocol 4-20 mA HART,WirelessHART, FOUNDATION fieldbus Measurement Range Up to 2000psi (137,89 bar) Differential, Up to 2000psig (137,89 bar) Gage, Up to 4000psia (275,79 bar) Absolute Process Wetted Material 316L SST, Alloy C-276, Alloy 400, Tantalum, Gold-plated Alloy 400, Gold-plated 316L SST Diagnostics Basic Diagnostics, Power Advisory Diagnostics, Advanced Diagnostics Certifications/Approvals SIL 2/3 certified to IEC 61508 by an independent 3rd party, NSF, NACE, hazardous location, see full specs for complete list of certifications Features Patented Rosemount Coplanar technology offers optimized performance as a pressure, DP Flow and DP Level solution Best-in-class, scalable architecture enhances performance, functionality and process connections Transmitter arrives fully assembled and leak tested for simple installation and maintenance All-welded hermetic SST SuperModule platform resists overpressure and line pressure effects to ensure 0.025% accuracy Ultra and Ultra for Flow performance classes deliver 15-year stability and 15-year limited warranty 200:1 rangedown produce reliable measurements and wide application flexibility Integrates seamlessly with 4-20 mA HARTÂ WirelessHART, FOUNDATIONâ?¢ fieldbus protocols for application flexibility SIL 2/3 certified to IEC 61508 (via 3rd party) and prior-use certificate of FMEDA data for safety installations Advanced diagnostics provide diagnostic coverage to detect electrical loop issues and abnormal process conditions Remote display and interface offers easy access to process and device information
Rosemount 3051 Coplanar Pressure Transmitter Specifications Warranty Up to 5-year limited warranty Rangedown Up to 150:1 Communication Protocol 4-20 mA HART,WirelessHART, FOUNDATION fieldbus, Profibus, 1-5 V Low Power HART Measurement Range Up to 2000psi (137,89 bar) Differential, Up to 2000psig (137,89 bar) Gage, Up to 4000psia (275,79 bar) Absolute Process Wetted Material 316L SST, Alloy C-276, Alloy 400, Tantalum, Gold-plated Alloy 400, Gold-plated 316L SST Diagnostics Basic Diagnostics, Power Advisory Diagnostics Certifications/Approvals SIL 2/3 certified to IEC 61508 by an independent 3rd party, NSF, NACE, hazardous location, see full specs for complete list of certifications Common models 3051CD2A02A1AB1H2L4M5 3051CD3A02A1AB1H2L4M5 3051CD4A02A1AB1H2L4M5 3051CD5A02A1AB1H2L4M5 3051CD1A02A1AB3H2L4M5 3051CD2A02A1AB3H2L4M5 3051CD3A02A1AB3H2L4M5 3051CD4A02A1AB3H2L4M5 3051CD5A02A1AB3H2L4M5 3051CD1A02A1AB1H2L4M5K5 3051CD2A02A1AB1H2L4M5K5 3051CD3A02A1AB1H2L4M5K5 3051CD4A02A1AB1H2L4M5K5 3051CD5A02A1AB1H2L4M5K5 3051CD1A02A1AB1H2L4M5E5 3051CD2A02A1AB1H2L4M5E5 3051CD1A02A1AB1H2L4M5I5 3051CD2A02A1AB1H2L4M5I5 3051CD3A02A1AB1H2L4M5I5 3051CD4A02A1AB1H2L4M5I5 3051CD5A02A1AB1H2L4M5I5 3051CD1A02A1AB3H2L4M5K5 3051CD2A02A1AB3H2L4M5K5 3051CD3A02A1AB3H2L4M5K5 3051CD4A02A1AB3H2L4M5K5 3051CD5A02A1AB3H2L4M5K5 3051CD1A02A1AB3H2L4M5E5 3051CD2A02A1AB3H2L4M5E5 3051CD3A02A1AB3H2L4M5E5 3051CD4A02A1AB3H2L4M5E5 3051CD5A02A1AB3H2L4M5E5 3051CD1A02A1AB3H2L4M5I5 3051CD2A02A1AB3H2L4M5I5 3051CD3A02A1AB3H2L4M5I5 3051CD4A02A1AB3H2L4M5I5 3051CD5A02A1AB3H2L4M5I5 3051CD1A22A1AB4M5 3051CD2A22A1AB4M5 3051CD3A22A1AB4M5 3051CD4A22A1AB4M5 3051CD5A22A1AB4M5 3051CD1A22A1AB4M5DF 3051CD2A22A1AB4M5DF 3051CD3A22A1AB4M5DF 3051CD4A22A1AB4M5DF 3051CD5A22A1AB4M5DF 3051CD1A22A1AB4M5K5 3051CD2A22A1AB4M5K5 3051CD3A22A1AB4M5K5 3051CD4A22A1AB4M5K5 3051CD5A22A1AB4M5K5 3051CD1A22A1AB4M5E5 3051CD2A22A1AB4M5E5 3051CD3A22A1AB4M5E5 3051CD4A22A1AB4M5E5 3051CD5A22A1AB4M5E5 3051CD1A22A1AB4M5I5 3051CD2A22A1AB4M5I5 3051CD3A22A1AB4M5I5 3051CD4A22A1AB4M5I5 3051CD5A22A1AB4M5I5
Rosemount 2090P Pulp and Paper Pressure Transmitter Introduction With its compact size and rugged construction, the Rosemount 2090P Pulp and Paper Pressure Transmitter is ideal for the pulp and paper industries. This lightweight transmitter is engineered with a 1 in. flush mount compatible with PMC process connection or 1 1/2 in. threaded mounting connection. This transmitter can be calibrated to ranges as low as 0 to 1.5 psi (0.1 bar) and as high as 0 to 300 psi (20.7 bar) for reliable measurement capabilities. Specifications Accuracy 0.20% Power Supply 10.5-42.4 V Warranty Up to 5-year limited warranty Rangedown Up to 20:1 Communication Protocol 4-20 mA HART Measurement Range Up to 300 psig (20,7 bar) Gage, Up to 300 psia (20,7 bar) Absolute Process Wetted Material 316L SST Diagnostics Basic Diagnostics Certifications/Approvals Hazardous location, see full specs for complete list of certifications Features 1 in. flush mount compatible with PMC process connection or 1 1/2 in. threaded mounting connection available Calibrates as low as 0 to 1.5 psi (0.1 bar) and as high as 0 to 300 psi (20.7 bar) for application flexibility Lightweight, compact design for easy installation Fully configurable LCD displays process variable, percent of range and diagnostic message Communicates via 4-20 mA HART� protocol for streamlined host integration Normal Models 2090PA1S22A1B4M5 2090PA2S22A1B4M5 2090PA3S22A1B4M5 2090PG1S22A1B4M5 2090PG2S22A1B4M5 2090PG3S22A1B4M5 2090PA1S22C1B4M5 2090PA2S22C1B4M5 2090PA3S22C1B4M2090PG1S22C1B4M5 2090PG2S22C1B4M5 2090PG3S22C1B4M5 2090PA1S22C2B4M5 2090PA2S22C2B4M5 2090PA3S22C2B4M5 2090PG1S22C2B4M5 2090PG2S22C2B4M5 2090PG3S22C2B4M5 2090PA1S22D1B4M5 2090PA2S22D1B4M5 2090PA3S22D1B4M5 2090PG1S22D1B4M5 2090PG2S22D1B4M5 2090PG3S22D1B4M5 2090PA1S22D2B4M5 2090PA2S22D2B4M5 2090PA3S22D2B4M5 2090PG1S22D2B4M5 2090PG2S22D2B4M5 2090PG3S22D2B4M5 2090PA1S22G1B4M5 2090PA2S22G1B4M5 2090PA3S22G1B4M5 2090PG1S22G1B4M5 2090PG2S22G1B4M5 2090PG3S22G1B4M5 2090PA1S22G2B4M5 2090PA2S22G2B4M5 2090PA3S22G2B4M5 2090PG1S22G2B4M5 2090PG2S22G2B4M5 2090PG3S22G2B4M5
Rosemount 2090f hygienic pressure transmitter Introduction Designed for hygienic applications, the rosemount 2090f hygienic pressure transmitter is specifically engineered for the pharmaceutical and food and beverage industries. Built with industry standard process connections, this device connects to sanitary fittings without special mounting hardware. In addition, this hygienic pressure transmitter conforms to 3-a sanitary standards, allowing you to meet tough process requirements. Specifications Accuracy 0.20% Power supply 10.5-42.4 v Warranty Up to 5-year limited warranty Rangedown Up to 20:1 Communication protocol 4-20 ma hart Measurement range Up to 300 psig (20, 7 bar) gage, up to 300 psia (20, 7 bar) absolute Process wetted material 316l sst Diagnostics Basic diagnostics Certifications/approvals 3-a sanitary standards, hazardous location, see full specs for complete list of certifications Features Tri clamp process connection designed for standard sanitary fittings Conforms to 3-a sanitary standards for hygienic application compliance Utilizes single-filled sensor system for reliability and accuracy Features cip/sip service for process temperatures of up to 140 â?? Fully configurable lcd displays process variable, percent of range and diagnostic messages Normal models 2090fa1s2de1b4m5 2090fa2s2de1b4m5 2090fa3s2de1b4m5 2090fg1s2de1b4m5 2090fg2s2de1b4m5 2090fg3s2de1b4m5 2090fa1s2df1b4m5 2090fa2s2df1b4m5 2090fa3s2df1b4m5 2090fg1s2df1b4m5 2090fg2s2df1b4m5 2090fg3s2df1b4m5 2090fa1s2de2b4m5 2090fa2s2de2b4m5 2090fa3s2de2b4m5 2090fg1s2de2b4m5 2090fg2s2de2b4m5 2090fg3s2de2b4m5 2090fa1s2df2b4m5 2090fa2s2df2b4m5 2090fa3s2df2b4m5 2090fg1s2df2b4m5 2090fg2s2df2b4m5 2090fg3s2df2b4m5
Key Features: 1.Configurable pressure display units 2. 2 independent limit switches with many configuration options 3.Analog signal output with possibility of characteristic curve spread, curve reversal and offset setting 4.Characteristic curve implementation via table with max. 30 measuring points 5.Complete configurable parameters and measuring point protocol possible through optional transmitter PC interface Key Specifications: 1.Relative pressure Measuring range: 0 ~ + 1.6 bar to 0 ~ +60 bar Overpressure: 4 bar ~ 200 bar Burst pressure: 7 bar ~ 250 bar Characteristics curve deviation: 0.5% FS or 1.0% FS 2.Vacuum and ± measuring ranges: Measuring range: 0 ~ (-) 1.0 bar to (-) 1 ~ +24 bar Overpressure: 4 bar ~ 100 bar Burst pressure: 7 bar ~ 150 bar Characteristics curve deviation: 1.0% Full scale 3.Permissible ambient temperature: -10° C ~ +70° C 4.Permissible media temperature: -10° C ~ + 70° C 5.Protection class: IP65 per DIN EN 60529 6.Non-linearity: < 1.0% full scale 7.Hysteresis: < 0.5% full scale 8.Power supply: 24 V AC/DC 9.Analog output signal: (0) 4-20mA / 0-10V 10.Output contacts: 2 potential free relay contact (32V AC/DC , 2A) or semiconductor switches (3~32 V AC/DC, 0.25A), configurable 11.EMC: EN 61326-1:2013, EN 61326-2:2013 12.Material (housing): stainless steel 1.4301 13.Process connection (media contact): stainless steel 1.4404 14.Measuring diaphragm: ceramic 15.Display: 4..6 digit LCD, full graphic, color changing 16.Configurable: attenuation, switching output, measuring range unit, output signal, zero point stability, implementation of characteristic curve, password Application areas: 1.Pump Control system 2.pump and compressors monitoring 3.Filling level measuring Industrial areas: 1.Process engineering 2.Environment engineering 3.Renewable energy eg. biogas etc 4.Waste Water Engineering 5.Effluent treatment 6.Breweries, alcohol industry
Vacuum pressure transmitter ZS-II by Yoyik YOYIK, with advanced technical equipment and rich industry experience, provides all-round solutions for technical transformation and overhaul projects in thermal power, hydropower, steel and other fields. From equipment selection to installation and commissioning, to after-sales service, every link reflects the company's professionalism and meticulousness. At the same time, as a multi-brand agent, YOYIK ensures that every product is authentic and reliable to meet the personalized needs of different customers. Yoyik can offer many spare parts for power plants as below: #DF-Vacuum pressure transmitter ZS-II by Yoyik-DF Fuse RT 18-32 [1A,2A,6A,10A] proximity sensor eddy current PR6424/010-140 Pressure gauge Z1203888 Battery Holder Storage Box with Gold Plated Phosphor Bronze Pins 2x18650 LVDT Sensor CZTD-6A-250T Locator 6DR5020-0NN00-0AA0 Low voltage control valve LVDT 0BJ-B31-25.4 Base Terminal Module FM131-A-B Bolt electric heating rod ZJ-20-12(R) thermal resistance constant WZP2-221 WEIGHING SENSOR GD2151107 Cooling fan HIER 465117 P001 Generator Hydrogen Purity Meter Flow Meter LZB-39 Heating rod DJ-24.5 RTD sensor WZPM2-08-75-M18-8 LVDT transmitter XCBSQ-01/500-01-11 Transformers oil-surface thermometer BWY-804JJ(TH) speed sensor CS-1-A00-B00-C08-D01 linear position sensor ZDET-200B level indicator tank LU83-5101 LVDT Sensor LVDT-250-6 Aviation plug ZKE-DJZ03(380)-12B analog pressure switch D505/18D Motor protection circuit breaker PKZM0/PKZMC-1.6(1-1.6A)MOE.225387 Excitation Acquisition Card (MUB Card) 3BHE009319R0001 desiccant respirator 3KG Nemicon encoder OVW2-10-2MHC Load cell RTNC3/10t Linear variable differential transformer of CV valve 0508.902T0201.AW021 Eddy Current Sensor PR6424/102-000 speed sensor CS-1H-G-060-03-02 Double platinum thermistor WZP2-221(Pt100) IGNITION ELECTRODE XDH -20W Vibration Gauge CWY-DO-810507 Eddy Current Sensor PR6422/003-121 lvdt in control system TD-1 Vacuum pressure transmitter ZS-II by Yoyik MY-DFYL-2024-7-18
Pressure transmitter CY-I for Thermal Power YOYIK, located in Deyang, Sichuan, is a comprehensive power station equipment and accessories company integrating R&D, manufacturing and sales. It is well-known in the industry for its exquisite craftsmanship and strict quality control. The company not only provides key components for thermal power and hydropower stations at home and abroad, but also involves in new energy fields such as wind energy and nuclear energy, showing strong innovation and adaptability. With customized services and global market layout, YOYIK has become a trusted partner of many large projects. Yoyik can offer many spare parts for power plants as below: #DF-Pressure transmitter CY-I for Thermal Power-DF Level Gauge Sight Glass With Seal AL-Si 88412 No-0019 TLTG Eddy Current Sensor PR6422/003-031 Displacement sensor LVDT for GV TD-1-250-10-01-0 Eddy Current Sensor PR6422/001-030 pressure switch price RC861CZ090HYR speed sensor CS-4-100-02-01 card CI-132I Presure Sensor SZ010BF-C2 Turbine Expansion Sensor TD-2 (0-35mm) Thermal Case Expansion TD-2-26 Eddy Current Signal Converter CON041/915-040 Temperature Transmitter JM-B-T010-562D2 VACCUM CIRCUIT BREAKER ZN63-VS1-3150-40KA Proximity switch E2B-M12LS04-WZ-B1 PNP industrial displacement sensor HTD-200-3 SFP Multimode LC OSP155-312DTR tachometer magnetic sensor ZS-04 L=65 differential pressure sensor 1NN-K45-M4-F1A INTELLIGENT REVERSE ROTATING SPEED MONITORING DEVICE JM-C-337 sensor CS-3-M10-L100 LVDT Sensor TDZ-1E-20B Pressure Controller RC778NZ097Z Thyristor NFP-KC5 Embedded touch screen HSDS-30/C vibration transmitter STA-SZ6-50 LVDT Sensor 4000TD-15-01 Intermediate relay UEG/C-3H3D LVDT Governor Valve 191.36.09.07 RANGE:�±127mm Furnace tube leakage data acquisition board AD6311 Coil 1240-220V Eddy Current Sensor PR6426/000-120 linear motion sensor 14000TD 0-700mm magnetic level sensor UHZ-618C17 Thermohygrograph Monitor L2W2K-Z3A(TH) Thermal expansion monitoring instrument DF9032/05 Auxiliary power PSMU-1-12V/480W Pressure transmitter CY-I for Thermal Power MY-DFYL-2024-7-17
Features: 1. Completely submersible liquid level transmitter 2. Wide variety of sensors, e.g. extension tube or flexible cable, standard or high temperature 3. Measuring range up to 328ft (100m) 4. 4-20mA output, 2-wire loop powered 5. Pressure transducer also available
The ec series is a hydrostatic pressure level transmitter for measuring the level of liquids in various tanks and other types of vessels. The ec hydrostatic pressure level transmitter consists of a piezoresistive sensor and wheatstone bridge to directly measure head pressure exerted on the diaphragm of the ec level transmitter. When the pressure is exerted on the diaphragm, as a result of the liquid level, the pressure is transferred to the wheatstone bridge electrical circuit through silicon oil contained in the ec sensing unit. This creates a differential voltage, which is then amplified to create a variable 4-20ma output that varies as a result of the changing liquid level. In addition, a pressure transducer is available for measuring pressure in tanks or pipes and producing a variable 4-20ma output. Application: Use 1.Extension cable unit can measure in deep wells or reservoirs 2.Tank level measurement and control 3.Plc or dcs input for level control functions 4.Pressure measurement of gas or liquid (ec1500) Industry 1.Water treatment and distribution 2.Chemical 3.Many others
Smartline st 800 differential pressure transmitters (std800) bring smart technology to a wide spectrum of measurement applications ranging from furnace combustion airflow rate to hydrostatic tank gauging. The transmitters can be used with any primary flow element to provide proven, repeatable flow measurement. Std800 differential pressure transmitters are ideal for critical process loops and high-value applications such as. -
Key Features: 1.Very low pressure measurable without long-term drift 2.Rugged design 3.Maintenance free 4.Over-pressure protected Key Specifications: 1.Measuring range: 0 ~ 25 Pa to 0 ~ 1000 Pa 2.Maximum static operating pressure: 1.0 bar 3.Maximum safe pressure: 1.7 bar 4.Straight line error (max.): 1.0 % Full scale 5.Pressure connection: screw clamp connectors (aluminum) for 6/4 mm or 8/6 tube 6.Repeatability: 0.1 % full scale 7.Operating ambient & media temperature: -10° C to +70° C 8.Protection class: IP65 per DIN EN 60529 9.Linearity: < 2% Full scale 10.Electrical output: 4-20mA linear, 2 â?? wire 11.Power supply: 24 V DC 12.Material, housing: Polyamide PA 6,6 13.Materials, media contact: Silicon, PVC, aluminum, brass Application areas: 1.Filter status / condition monitoring 2.Precision air duct measurement 3.Clean room pressure balance monitoring 4.Burner air feed low pressure detection 5.Oven air feed control Industrial areas: 1.Air conditioning and ventilation systems 2.Auditorium, office, conference rooms 3.HVAC and ventilation application 4.Environment monitoring 5.Clean room and laboratory rooms
Product Range Design Code ASME Section VIII, Div I, PD 5500, AD Merkblatter, PED 97/23/EC, IS 2825 or any other international standard. Capacity Upto 500 M3 ( 5,00,000 Liters water volume) Diameter Upto 6 meters Shell & Dished End Thickness Upto 100 mm or more Weight Upto 250 tons Length Upto 60 meters, with suitable field joints. Material of Construction Carbon Steel, LTCS, NACE & HIC resistant Material, Low Alloy Steel for high temperature service (SA 387 Gr 11 and Gr 22), Cladded Steel (CS with SS, Cupronickel, Aluminum Nickel Bronze, Aluminum brass, Titanium, Inconel and many more), SS (300 & 400 series), Duplex & Super Duplex stainless steel, Cupronickel, Monel , Inconel, Nickel & Nickel Alloys, Hastelloy, Titanium, Aluminum & Aluminum alloys.
High precision air pressure regulator: T10 is a very higy precision pressure regulator, pressure stability is achieved by a high performance servo-operated control mechanism utilized in the regulator and the pressure supplied to the pneumatic servo amplifier is reduced and held constant. A stainless steel measuring capsule is used as a sensing element to activate the high gain servo balanced control mechanism in which the main valve is controlled by a pilot valve.This allows for greater accuracy and eliminates many of the problems associated with conventional regulators using range springs and diaphragms. Feature: Accurate pressure regulation: control output pressure to within 0.5% accuracy, regulated pressure variation as small as 0.06kpa is self corrected. Satable output: substantial changes in flow have virtually no effect on regulated pressure within 12 scfm. Dependable startup: retuns the regulated pressure to its original output setting even after long í¦down timeí¦. Temperature stability: a stainless steel measuring capsule which activates the servo control, no effects on regulated pressure in wide vaviations operating temperature. Feature data Exhaust capacity: 5 psig (35kpa) above 20 psig (140 kpa) setpointú¼type100hr - 10 scfm (17.0 m3/hr.) (high relief). Sensitivityú¦less than 1/8" (3.2mm) water Mounting options: pipe or panel. Port sizes: 1/4" npt Maximum supply pressure: 1mpa(1050kpa) Main materials: diecast zinc alloy, stainless steel, metal lacquer on body. Weight: 0.63kg Output pressure ranges: 14~500kpa Plastic bag, inner box, master carton
Outstanding quality is definitely your best choice for pressure gauge. Standard export packaging
Pressure transmitter, digital pressure gauges, differential pressure transmitter, pressure transducer, level pressure transmitter, industrial pressure transmitter, air compressor pressure transmitter, melt pressure transmitter, smart differential pressure transmitter, pressure switch.Design, OEM