yinuo-link industrial 5 ports 100Mbps ethernet switch support positive and negative dc input Description: YN-IES10502 is 5 port industrial grade unmanaged Ethernet switch, it has 5*10/100Mbps self-adaption Ethernet ports. Provide DC input and positive and negative connection protection to prevent burnout. Small size design, and support industry-standard DIN Rail mounting and wall mounting, it is easy to install in any industrial environment. Advantages: 1. Using 8 Port high-temperature and low-temperature industrial-grade import chip, the processing capacity is stronger. 2. PCB using high temperature plate TG150 KB material, immersion gold process; good antioxidant capacity. 3. Crystal import from Japan Kyocera brand (the world's most famous crystal). 4. Network port using gold-plated 1.5U, conventional is 0.6-0.8u, itâ??s good for pull and plug time. 5. Import Power Supply, the largest support 12-50V. 6. All capacitors use Murata brand, the filter effect is strong stability. 7. Static support 4KV contact, power supply and network port surge support IEC61000-4-5 standard differential mode 2KV, common mode 4KV. Features: 1. Support IEEE 802.3, IEEE 802.3u, IEEE 802.3ab standard; 2. Full-duplex use IEEE 802.3x standard, half-duplex use Backpressure standard; 3. 5*10/100M self-adaption RJ45 port, all ports support auto flip (Auto MDI / MDIX) 4. Each port support auto-negotiation function, automatic adjust the transmission mode and transmission rate; 5. Support MAC address self-learning; 6. Dynamic LED indicator, to provide a simple working status tips and troubleshooting; 7. Lightning, surge, static full protection, surge differential mode 2KV, common mode 4KV. 8. Redundant dual DC power input overload protection; 9. Using industrial 3P terminal 24-36V input maximum support 50V. Power supply use US chips
Description 410 stainless steel is food grade, 410 stainless steel is not toxic, and it is not harmful to the human body when used as tableware. 410 stainless steel is a stainless steel grade produced in accordance with the American ASTM standard, equivalent to China's 1Cr13 stainless steel, S41000 (American AISI, ASTM). Carbon 0.15%, chromium 13%,410 stainless steel: has good corrosion resistance, machinability, general purpose blade class, valve class. Choose stainless steel products, recommended to choose 304 steel. 304 steel (refers to stainless steel with chromium content of 18% and nickel content of 8%) is widely used in corrosion-resistant containers, tableware, furniture, railings, medical equipment and so on. The purchase of stainless steel products should be optimistic about the type of labeling. There are often "13-0" (420 steel), "18-0" (430 steel), "18-8" (304 steel) on the stainless steel tableware, the number in front of the code indicates the chromium content, and the number behind represents the nickel content. Whether stainless steel utensils are safe is mainly a problem of heavy metal migration. In general, the 304 steel common on the market now is less chromium migration. 410 stainless steel Features: 1, high strength. 2. Excellent machinability. 3. Hardening occurs after heat treatment. 4. Magnetic. 5, not suitable for harsh corrosive environment. 6, scope of application: general blade, mechanical parts, class 1 tableware (spoon, fork, knife, etc.).
The compact Dtorque 111 is designed to revolutionize the small workboat market where its expected lifespan of well over 10,000 hours at least doubles that of any comparable outboard gasoline engine. The Dtorque 111 offers a remarkably smooth and quiet diesel engine, delivering 50 hp at the propeller with a stunning torque output of 111 Nm at just 2,500 rpm. This is considerably better than the latest 70 hp 4-stroke gasoline models and more than enough to quickly accelerate most small craft onto the plane with plenty of low-down lugging power for heavy displacement duty. The Dtorque is the ideal choice if you operate or manage: work boats safety/rescue boats fishing boats governmental and port authority vessels passenger boats superyacht tenders Increased Safety Diesel is less flammable than gasoline, and so the Dtorque is the safer choice for potentially hazardous environments, such as in the oil and gas industry. Superyacht and cruise ship operators, for example, will also benefit from the time and cost savings associated with having fewer fire safety precautions and regulations. In addition, there is only one type of fuel to manage, which is more widely available in ports all over the world. The Dtorque also exceeds EU RDC Stage II emissions regulations, however, is not yet EPA compliant. Low Noise and Vibration The Dtorque has a two-cylinder, common rail, turbo-charged diesel engine that uses a unique system of dual counter-rotating crankshafts in an aluminum block. This technology, with its patented â??Spaceballâ?? design, helps reduce vibrations and noise. Another advantage of these crankshafts is the lack of rotating and operating (steering) torques. This results in less fatigue during the engines operation.
Specifications Rated Output 419 kW 57 mhp Rated Speed 3000 rpm Displacement 219 L 134 cu in No of cylinders 4 cylinders Cylinder Bore x Stroke 88 mm x 90 mm 346 in x 354 in Combustion system Direct Injection Bosch Common Rail System Aspiration Natural Alternator 12V 125A Dry weight without gear 220 kg 485 lbs Dimensions 870 mm x 589 mm x 627 mm Controls Mechanical optional VC10 system Certifications RCD 2 EPA Tier 3 EPA Tier 3C BSO II EMC SOLAS NOTE 1 kW 13596 mhp 134102 bhp Fuel condition density at 15C 0842 gcm Technical data is according to ISO 8665 ISO 3046 Fuel temperature 40C at the inlet of the fuel injection pump ISO 8665 Length includes KM35P marine gear Dimensions may vary with other gearselbow Standard Engine Package Exhaust mixing elbow Ltype Alternator 12V 125A B25 panel Flexible mounts Mechanical throttle sensor Fuel prefilter with water separator Fresh water expansion tank Belt safety cover Optional Accessories Highriser mixing elbow instead of Lelbow Secondary alternator 12V 125A or 24V 60A C35 panel Extension harness 3m 5m 10m Second station TFX Sidemount control head VC10 Vessel Control System NMEA2000 Engine monitoring system Semi 2pole SOLAS including Certificate factory fit only Hot water kit with cocks Extension saildrive leg 75 mm Propeller cone nut kit SD60 Onboard spare parts kit
Specifications Rated Output 588 kW 80 mhp Rated Speed 3200 rpm Displacement 2 L 122 cu in No of cylinders 4 cylinders Cylinder Bore x Stroke 84 mm x 90 mm 331 in x 354 in Combustion system Direct Injection Bosch Common Rail System Aspiration Turbocharged Intercooled Alternator 12V 125A Dry weight without gear 229 kg 505 lbs Dimensions 909 mm x 613 mm x 675 mm Controls Mechanical optional VC10 system Certifications RCD 2 EPA Tier 3 EPA Tier 3C BSO II EMC SOLAS NOTE 1 kW 13596 mhp 134102 bhp Fuel condition density at 15C 0842 gcm Technical data is according to ISO 8665 ISO 3046 Fuel temperature 40C at the inlet of the fuel injection pump ISO 8665 Length includes KM4A2 marine gear Dimensions may vary with other gearselbow Standard Engine Package Exhaust mixing elbow Ltype Alternator 12V 125A Seawater pump rear mounted B25 panel Flexible mounts Mechanical throttle sensor Fuel prefilter with water separator Fresh water expansion tank Belt safety cover Optional Accessories Highriser mixing elbow instead of Lelbow Secondary alternator 12V 125A or 24V 60A Seawater pump front mounted C35 panel Extension harness 3m 5m 10m Second station Sidemount control head VC10 Vessel Control System NMEA2000 Engine monitoring system Semi 2pole SOLAS including Certificate factory fit only Opposite dipstick Hot water kit with cocks Extension saildrive leg 75 mm Propeller cone nut kit SD60 Onboard spare parts kit
Product Introduction The mold transport cart is designed for die or mold handling. The mold transport cart is powered by dragged cable. The capacity load of the mold transport cart can reach 500 tons. Depending on the size of the die or mold, you can choose the size and load capacity of the mold transport cart. Working Principle When the mold transport cart moves, the cable pulls behind the mold transport cart. The cable is connected to the ground at one end, while the other is powered by an electric control box on mold transport cart, and then provide the power to the engine. The mold transport cart conduct AC 380V directly into the electrical control system of the mold transport cart to let it start, stop, go forward and backward and so on. Performance Characters 1. As a common tool for short-distance transit across the factory, the mold transport cart has a simple structure, low production cost. 2. This series mold transport carts are suitable to be used in the bad environment, for example, high-tempeture and anti-explosion condition. Compared with KPX series cart, the using time is not limited. 3. Compared with KPD series cart, it has no strict requirement on the rail's installation. Compared with KPJ series cart, the cost is lower. 4. Mesa size, the gauge can be customized. Various non-standard mold transport cart can also be obtained. 5. Choose import wireless remote control, control the distance of 100 meters.
Our comprehensive product range encompasses Head Rotors, Nozzles, Plungers, Diesel Injectors, Delivery Valves, Pencil Nozzles, Common Rail Parts, and more.
Want to buy best parts with a competitive price ? we will response you in 24 hours! Product description For the switching and control of lighting systems, heating, ventilation, pumps, heat pumps and other building automation systems. Devices for panel mounting on mounting rails (35 mm) according to DIN EN 60715. Depth of assembly: 58 mm. Gray. Magnetic drive without hum, silent switching, switching position indication, integrated coil circuit, mountable auxiliary switch, coil overvoltage protection up to 5 kV, high switching capacity and long service life, fast clamping with push button pressure, large connections with open-frame terminals, contact protection according to VDE 0106 part 100. The nominal operating voltage is 440 V. The nominal operating current is 24 A. The rated operating voltage is 230 V. The supply voltage is AC. The operating voltage type is AC / DC. With 4 contacts. With 0 opening contacts. Maximum capacity: Charge of the incandescent lamp: 1000 W. Fluorescent lamp charge: 700 VA. Maximum capacity: Fluorescent lamp charge (double circuit): 1400 VA. Maximum capacity: Fluorescent lamp. Lead-acid battery voltage for the buffer of ABB I Bus ® system to work for average network time periods for min. 10 minutes (full load) connection via standard 4-core cable. Additional Information ASIN B0020LSJE6 Average customer rating Be the first to review this item Ranking in the Amazon best sellers 27.426 in DIY and tools (See the 100 best sellers) 92 in DIY and tools> Electrical installation> Surge protectors 32116 in Electronics> Computers Frequently Asked Questions. How about your stock? We have large quantity for common used items, Can you send goods in time? We can ship to you via DHL/TNT/UPS/EMS/Fedex in 3 days after payment. it takes about maximum 7 days by air to most of the world. How long about your guarantee: our guarantee period is one year. Are your products are origin and brand new? Yes, we only do business of Origin and brand new products. If there is anything else you want to know, ABB: 1) AC800M series controller I/O module 2) AC800F series controller module 3) AC31 series controller module 4) 800xA series modules 5) Bailey INFI 90 module 6) DSQC robot module spare parts 7) Advant OCS system spare parts 8) H&B Freelance Select the right products & services to meet your needs!
Want to buy best parts with a competitive price ? we will response you in 24 hours! Product description For the switching and control of lighting systems, heating, ventilation, pumps, heat pumps and other building automation systems. Devices for panel mounting on mounting rails (35 mm) according to DIN EN 60715. Depth of assembly: 58 mm. Gray. Magnetic drive without hum, silent switching, switching position indication, integrated coil circuit, mountable auxiliary switch, coil overvoltage protection up to 5 kV, high switching capacity and long service life, fast clamping with push button pressure, large connections with open-frame terminals, contact protection according to VDE 0106 part 100. The nominal operating voltage is 440 V. The nominal operating current is 24 A. The rated operating voltage is 230 V. The supply voltage is AC. The operating voltage type is AC / DC. With 4 contacts. With 0 opening contacts. Maximum capacity: Charge of the incandescent lamp: 1000 W. Fluorescent lamp charge: 700 VA. Maximum capacity: Fluorescent lamp charge (double circuit): 1400 VA. Maximum capacity: Fluorescent lamp. Lead-acid battery voltage for the buffer of ABB I Bus ® system to work for average network time periods for min. 10 minutes (full load) connection via standard 4-core cable. Additional Information ASIN B0020LSJE6 Average customer rating Be the first to review this item Ranking in the Amazon best sellers 27.426 in DIY and tools (See the 100 best sellers) 92 in DIY and tools> Electrical installation> Surge protectors 32116 in Electronics> Computers Frequently Asked Questions. How about your stock? We have large quantity for common used items, Can you send goods in time? We can ship to you via DHL/TNT/UPS/EMS/Fedex in 3 days after payment. it takes about maximum 7 days by air to most of the world. How long about your guarantee: our guarantee period is one year. Are your products are origin and brand new? Yes, we only do business of Origin and brand new products. If there is anything else you want to know, ABB: 1) AC800M series controller I/O module 2) AC800F series controller module 3) AC31 series controller module 4) 800xA series modules 5) Bailey INFI 90 module 6) DSQC robot module spare parts 7) Advant OCS system spare parts 8) H&B Freelance Select the right products & services to meet your needs!
Want to buy best parts with a competitive price ? we will response you in 24 hours! Product description For the switching and control of lighting systems, heating, ventilation, pumps, heat pumps and other building automation systems. Devices for panel mounting on mounting rails (35 mm) according to DIN EN 60715. Depth of assembly: 58 mm. Gray. Magnetic drive without hum, silent switching, switching position indication, integrated coil circuit, mountable auxiliary switch, coil overvoltage protection up to 5 kV, high switching capacity and long service life, fast clamping with push button pressure, large connections with open-frame terminals, contact protection according to VDE 0106 part 100. The nominal operating voltage is 440 V. The nominal operating current is 24 A. The rated operating voltage is 230 V. The supply voltage is AC. The operating voltage type is AC / DC. With 4 contacts. With 0 opening contacts. Maximum capacity: Charge of the incandescent lamp: 1000 W. Fluorescent lamp charge: 700 VA. Maximum capacity: Fluorescent lamp charge (double circuit): 1400 VA. Maximum capacity: Fluorescent lamp. Lead-acid battery voltage for the buffer of ABB I Bus ® system to work for average network time periods for min. 10 minutes (full load) connection via standard 4-core cable. Additional Information ASIN B0020LSJE6 Average customer rating Be the first to review this item Ranking in the Amazon best sellers 27.426 in DIY and tools (See the 100 best sellers) 92 in DIY and tools> Electrical installation> Surge protectors 32116 in Electronics> Computers Frequently Asked Questions. How about your stock? We have large quantity for common used items, Can you send goods in time? We can ship to you via DHL/TNT/UPS/EMS/Fedex in 3 days after payment. it takes about maximum 7 days by air to most of the world. How long about your guarantee: our guarantee period is one year. Are your products are origin and brand new? Yes, we only do business of Origin and brand new products. If there is anything else you want to know, ABB: 1) AC800M series controller I/O module 2) AC800F series controller module 3) AC31 series controller module 4) 800xA series modules 5) Bailey INFI 90 module 6) DSQC robot module spare parts 7) Advant OCS system spare parts 8) H&B Freelance Select the right products & services to meet your needs!
Want to buy best parts with a competitive price ? we will response you in 24 hours! Product description For the switching and control of lighting systems, heating, ventilation, pumps, heat pumps and other building automation systems. Devices for panel mounting on mounting rails (35 mm) according to DIN EN 60715. Depth of assembly: 58 mm. Gray. Magnetic drive without hum, silent switching, switching position indication, integrated coil circuit, mountable auxiliary switch, coil overvoltage protection up to 5 kV, high switching capacity and long service life, fast clamping with push button pressure, large connections with open-frame terminals, contact protection according to VDE 0106 part 100. The nominal operating voltage is 440 V. The nominal operating current is 24 A. The rated operating voltage is 230 V. The supply voltage is AC. The operating voltage type is AC / DC. With 4 contacts. With 0 opening contacts. Maximum capacity: Charge of the incandescent lamp: 1000 W. Fluorescent lamp charge: 700 VA. Maximum capacity: Fluorescent lamp charge (double circuit): 1400 VA. Maximum capacity: Fluorescent lamp. Lead-acid battery voltage for the buffer of ABB I Bus ® system to work for average network time periods for min. 10 minutes (full load) connection via standard 4-core cable. Additional Information ASIN B0020LSJE6 Average customer rating Be the first to review this item Ranking in the Amazon best sellers 27.426 in DIY and tools (See the 100 best sellers) 92 in DIY and tools> Electrical installation> Surge protectors 32116 in Electronics> Computers Frequently Asked Questions. How about your stock? We have large quantity for common used items, Can you send goods in time? We can ship to you via DHL/TNT/UPS/EMS/Fedex in 3 days after payment. it takes about maximum 7 days by air to most of the world. How long about your guarantee: our guarantee period is one year. Are your products are origin and brand new? Yes, we only do business of Origin and brand new products. If there is anything else you want to know, ABB: 1) AC800M series controller I/O module 2) AC800F series controller module 3) AC31 series controller module 4) 800xA series modules 5) Bailey INFI 90 module 6) DSQC robot module spare parts 7) Advant OCS system spare parts 8) H&B Freelance Select the right products & services to meet your needs!
Want to buy best parts with a competitive price ? we will response you in 24 hours! Product description For the switching and control of lighting systems, heating, ventilation, pumps, heat pumps and other building automation systems. Devices for panel mounting on mounting rails (35 mm) according to DIN EN 60715. Depth of assembly: 58 mm. Gray. Magnetic drive without hum, silent switching, switching position indication, integrated coil circuit, mountable auxiliary switch, coil overvoltage protection up to 5 kV, high switching capacity and long service life, fast clamping with push button pressure, large connections with open-frame terminals, contact protection according to VDE 0106 part 100. The nominal operating voltage is 440 V. The nominal operating current is 24 A. The rated operating voltage is 230 V. The supply voltage is AC. The operating voltage type is AC / DC. With 4 contacts. With 0 opening contacts. Maximum capacity: Charge of the incandescent lamp: 1000 W. Fluorescent lamp charge: 700 VA. Maximum capacity: Fluorescent lamp charge (double circuit): 1400 VA. Maximum capacity: Fluorescent lamp. Lead-acid battery voltage for the buffer of ABB I Bus ® system to work for average network time periods for min. 10 minutes (full load) connection via standard 4-core cable. Additional Information ASIN B0020LSJE6 Average customer rating Be the first to review this item Ranking in the Amazon best sellers 27.426 in DIY and tools (See the 100 best sellers) 92 in DIY and tools> Electrical installation> Surge protectors 32116 in Electronics> Computers Frequently Asked Questions. How about your stock? We have large quantity for common used items, Can you send goods in time? We can ship to you via DHL/TNT/UPS/EMS/Fedex in 3 days after payment. it takes about maximum 7 days by air to most of the world. How long about your guarantee: our guarantee period is one year. Are your products are origin and brand new? Yes, we only do business of Origin and brand new products. If there is anything else you want to know, ABB: 1) AC800M series controller I/O module 2) AC800F series controller module 3) AC31 series controller module 4) 800xA series modules 5) Bailey INFI 90 module 6) DSQC robot module spare parts 7) Advant OCS system spare parts 8) H&B Freelance Select the right products & services to meet your needs!
Want to buy best parts with a competitive price ? we will response you in 24 hours! Product description For the switching and control of lighting systems, heating, ventilation, pumps, heat pumps and other building automation systems. Devices for panel mounting on mounting rails (35 mm) according to DIN EN 60715. Depth of assembly: 58 mm. Gray. Magnetic drive without hum, silent switching, switching position indication, integrated coil circuit, mountable auxiliary switch, coil overvoltage protection up to 5 kV, high switching capacity and long service life, fast clamping with push button pressure, large connections with open-frame terminals, contact protection according to VDE 0106 part 100. The nominal operating voltage is 440 V. The nominal operating current is 24 A. The rated operating voltage is 230 V. The supply voltage is AC. The operating voltage type is AC / DC. With 4 contacts. With 0 opening contacts. Maximum capacity: Charge of the incandescent lamp: 1000 W. Fluorescent lamp charge: 700 VA. Maximum capacity: Fluorescent lamp charge (double circuit): 1400 VA. Maximum capacity: Fluorescent lamp. Lead-acid battery voltage for the buffer of ABB I Bus ® system to work for average network time periods for min. 10 minutes (full load) connection via standard 4-core cable. Additional Information ASIN B0020LSJE6 Average customer rating Be the first to review this item Ranking in the Amazon best sellers 27.426 in DIY and tools (See the 100 best sellers) 92 in DIY and tools> Electrical installation> Surge protectors 32116 in Electronics> Computers Frequently Asked Questions. How about your stock? We have large quantity for common used items, Can you send goods in time? We can ship to you via DHL/TNT/UPS/EMS/Fedex in 3 days after payment. it takes about maximum 7 days by air to most of the world. How long about your guarantee: our guarantee period is one year. Are your products are origin and brand new? Yes, we only do business of Origin and brand new products. If there is anything else you want to know, ABB: 1) AC800M series controller I/O module 2) AC800F series controller module 3) AC31 series controller module 4) 800xA series modules 5) Bailey INFI 90 module 6) DSQC robot module spare parts 7) Advant OCS system spare parts 8) H&B Freelance Select the right products & services to meet your needs!
Want to buy best parts with a competitive price ? we will response you in 24 hours! Product description For the switching and control of lighting systems, heating, ventilation, pumps, heat pumps and other building automation systems. Devices for panel mounting on mounting rails (35 mm) according to DIN EN 60715. Depth of assembly: 58 mm. Gray. Magnetic drive without hum, silent switching, switching position indication, integrated coil circuit, mountable auxiliary switch, coil overvoltage protection up to 5 kV, high switching capacity and long service life, fast clamping with push button pressure, large connections with open-frame terminals, contact protection according to VDE 0106 part 100. The nominal operating voltage is 440 V. The nominal operating current is 24 A. The rated operating voltage is 230 V. The supply voltage is AC. The operating voltage type is AC / DC. With 4 contacts. With 0 opening contacts. Maximum capacity: Charge of the incandescent lamp: 1000 W. Fluorescent lamp charge: 700 VA. Maximum capacity: Fluorescent lamp charge (double circuit): 1400 VA. Maximum capacity: Fluorescent lamp. Lead-acid battery voltage for the buffer of ABB I Bus ® system to work for average network time periods for min. 10 minutes (full load) connection via standard 4-core cable. Additional Information ASIN B0020LSJE6 Average customer rating Be the first to review this item Ranking in the Amazon best sellers 27.426 in DIY and tools (See the 100 best sellers) 92 in DIY and tools> Electrical installation> Surge protectors 32116 in Electronics> Computers Frequently Asked Questions. How about your stock? We have large quantity for common used items, Can you send goods in time? We can ship to you via DHL/TNT/UPS/EMS/Fedex in 3 days after payment. it takes about maximum 7 days by air to most of the world. How long about your guarantee: our guarantee period is one year. Are your products are origin and brand new? Yes, we only do business of Origin and brand new products. If there is anything else you want to know, ABB: 1) AC800M series controller I/O module 2) AC800F series controller module 3) AC31 series controller module 4) 800xA series modules 5) Bailey INFI 90 module 6) DSQC robot module spare parts 7) Advant OCS system spare parts 8) H&B Freelance Select the right products & services to meet your needs!
Want to buy best parts with a competitive price ? we will response you in 24 hours! Product description For the switching and control of lighting systems, heating, ventilation, pumps, heat pumps and other building automation systems. Devices for panel mounting on mounting rails (35 mm) according to DIN EN 60715. Depth of assembly: 58 mm. Gray. Magnetic drive without hum, silent switching, switching position indication, integrated coil circuit, mountable auxiliary switch, coil overvoltage protection up to 5 kV, high switching capacity and long service life, fast clamping with push button pressure, large connections with open-frame terminals, contact protection according to VDE 0106 part 100. The nominal operating voltage is 440 V. The nominal operating current is 24 A. The rated operating voltage is 230 V. The supply voltage is AC. The operating voltage type is AC / DC. With 4 contacts. With 0 opening contacts. Maximum capacity: Charge of the incandescent lamp: 1000 W. Fluorescent lamp charge: 700 VA. Maximum capacity: Fluorescent lamp charge (double circuit): 1400 VA. Maximum capacity: Fluorescent lamp. Lead-acid battery voltage for the buffer of ABB I Bus ® system to work for average network time periods for min. 10 minutes (full load) connection via standard 4-core cable. Additional Information ASIN B0020LSJE6 Average customer rating Be the first to review this item Ranking in the Amazon best sellers 27.426 in DIY and tools (See the 100 best sellers) 92 in DIY and tools> Electrical installation> Surge protectors 32116 in Electronics> Computers Frequently Asked Questions. How about your stock? We have large quantity for common used items, Can you send goods in time? We can ship to you via DHL/TNT/UPS/EMS/Fedex in 3 days after payment. it takes about maximum 7 days by air to most of the world. How long about your guarantee: our guarantee period is one year. Are your products are origin and brand new? Yes, we only do business of Origin and brand new products. If there is anything else you want to know, ABB: 1) AC800M series controller I/O module 2) AC800F series controller module 3) AC31 series controller module 4) 800xA series modules 5) Bailey INFI 90 module 6) DSQC robot module spare parts 7) Advant OCS system spare parts 8) H&B Freelance Select the right products & services to meet your needs!
Want to buy best parts with a competitive price ? we will response you in 24 hours! Product description For the switching and control of lighting systems, heating, ventilation, pumps, heat pumps and other building automation systems. Devices for panel mounting on mounting rails (35 mm) according to DIN EN 60715. Depth of assembly: 58 mm. Gray. Magnetic drive without hum, silent switching, switching position indication, integrated coil circuit, mountable auxiliary switch, coil overvoltage protection up to 5 kV, high switching capacity and long service life, fast clamping with push button pressure, large connections with open-frame terminals, contact protection according to VDE 0106 part 100. The nominal operating voltage is 440 V. The nominal operating current is 24 A. The rated operating voltage is 230 V. The supply voltage is AC. The operating voltage type is AC / DC. With 4 contacts. With 0 opening contacts. Maximum capacity: Charge of the incandescent lamp: 1000 W. Fluorescent lamp charge: 700 VA. Maximum capacity: Fluorescent lamp charge (double circuit): 1400 VA. Maximum capacity: Fluorescent lamp. Lead-acid battery voltage for the buffer of ABB I Bus ® system to work for average network time periods for min. 10 minutes (full load) connection via standard 4-core cable. Additional Information ASIN B0020LSJE6 Average customer rating Be the first to review this item Ranking in the Amazon best sellers 27.426 in DIY and tools (See the 100 best sellers) 92 in DIY and tools> Electrical installation> Surge protectors 32116 in Electronics> Computers Frequently Asked Questions. How about your stock? We have large quantity for common used items, Can you send goods in time? We can ship to you via DHL/TNT/UPS/EMS/Fedex in 3 days after payment. it takes about maximum 7 days by air to most of the world. How long about your guarantee: our guarantee period is one year. Are your products are origin and brand new? Yes, we only do business of Origin and brand new products. If there is anything else you want to know,pleases contact Sandy Contact: Sandy Lin Email:unity@mvme.cn Skype:onlywnn_1 Telegram:+8618020776786 Mobile(Whatsapp): (+86)-18020776786 QQ :2851195456 ABB: 1) AC800M series controller I/O module 2) AC800F series controller module 3) AC31 series controller module 4) 800xA series modules 5) Bailey INFI 90 module 6) DSQC robot module spare parts 7) Advant OCS system spare parts 8) H&B Freelance Select the right products & services to meet your needs!
Want to buy best parts with a competitive price ? we will response you in 24 hours! Product description For the switching and control of lighting systems, heating, ventilation, pumps, heat pumps and other building automation systems. Devices for panel mounting on mounting rails (35 mm) according to DIN EN 60715. Depth of assembly: 58 mm. Gray. Magnetic drive without hum, silent switching, switching position indication, integrated coil circuit, mountable auxiliary switch, coil overvoltage protection up to 5 kV, high switching capacity and long service life, fast clamping with push button pressure, large connections with open-frame terminals, contact protection according to VDE 0106 part 100. The nominal operating voltage is 440 V. The nominal operating current is 24 A. The rated operating voltage is 230 V. The supply voltage is AC. The operating voltage type is AC / DC. With 4 contacts. With 0 opening contacts. Maximum capacity: Charge of the incandescent lamp: 1000 W. Fluorescent lamp charge: 700 VA. Maximum capacity: Fluorescent lamp charge (double circuit): 1400 VA. Maximum capacity: Fluorescent lamp. Lead-acid battery voltage for the buffer of ABB I Bus ® system to work for average network time periods for min. 10 minutes (full load) connection via standard 4-core cable. Additional Information ASIN B0020LSJE6 Average customer rating Be the first to review this item Ranking in the Amazon best sellers 27.426 in DIY and tools (See the 100 best sellers)92 in DIY and tools> Electrical installation> Surge protectors 32116 in Electronics> Computers Frequently Asked Questions. How about your stock? We have large quantity for common used items, Can you send goods in time? We can ship to you via DHL/TNT/UPS/EMS/Fedex in 3 days after payment. it takes about maximum 7 days by air to most of the world. How long about your guarantee: our guarantee period is one year. Are your products are origin and brand new? Yes, we only do business of Origin and brand new products. If there is anything else you want to know, ABB: 1) AC800M series controller I/O module 2) AC800F series controller module 3) AC31 series controller module 4) 800xA series modules 5) Bailey INFI 90 module 6) DSQC robot module spare parts 7) Advant OCS system spare parts 8) H&B Freelance Select the right products & services to meet your needs!
Want to buy best parts with a competitive price? we will response you in 24 hours! Product description For the switching and control of lighting systems, heating, ventilation, pumps, heat pumps and other building automation systems. Devices for panel mounting on mounting rails (35 mm) according to DIN EN 60715. Depth of assembly: 58 mm. Gray. Magnetic drive without hum, silent switching, switching position indication, integrated coil circuit, mountable auxiliary switch, coil overvoltage protection up to 5 kV, high switching capacity and long service life, fast clamping with push button pressure, large connections with open-frame terminals, contact protection according to VDE 0106 part 100. The nominal operating voltage is 440 V. The nominal operating current is 24 A. The rated operating voltage is 230 V. The supply voltage is AC. The operating voltage type is AC / DC. With 4 contacts. With 0 opening contacts. Maximum capacity: Charge of the incandescent lamp: 1000 W. Fluorescent lamp charge: 700 VA. Maximum capacity: Fluorescent lamp charge (double circuit): 1400 VA. Maximum capacity: Fluorescent lamp. Lead-acid battery voltage for the buffer of ABB I Bus ® system to work for average network time periods for min. 10 minutes (full load) connection via standard 4-core cable. Additional Information ASIN B0020LSJE6 Average customer rating Be the first to review this item Ranking in the Amazon best sellers n º27.426 in DIY and tools (See the 100 best sellers) 92 in DIY and tools> Electrical installation> Surge protectors 32116 in Electronics> Computers Frequently Asked Questions. How about your stock? We have large quantity for common used items, Can you send goods in time? We can ship to you via DHL/TNT/UPS/EMS/Fedex in 3 days after payment. it takes about maximum 7 days by air to most of the world. How long about your guarantee: our guarantee period is one year. Are your products are origin and brand new? Yes, we only do business of Origin and brand new products. If there is anything else you want to know, ABB: 1) AC800M series controller I/O module 2) AC800F series controller module 3) AC31 series controller module 4) 800xA series modules 5) Bailey INFI 90 module 6) DSQC robot module spare parts 7) Advant OCS system spare parts 8) H&B Freelance Select the right products & services to meet your needs!
Product Description Double beam box type two trolley gantry crane Double beam box type two trolley gantry crane is applied outside warehouse or railway sideways to do common lifting and unloading works, Double beam box type two trolley gantry crane is composed of bridge, support legs, crane traveling organ, trolley, electric equipment, strong lifting winch, the frame adopts box-type welding mechanism, crane traveling mechanisms are operated in the driver cabin or remote control, Power is supplied by cable or slide wire, there are different capacity double beams gantry crane for your choice according to your different use. Electrical and Control Equipment Double beam box type two trolley gantry crane that we are offering is designed to meet the required functions and requirement stated in your specifications, as well as for the operating conditions. Packing & Delivery Packing: 1. Electric parts are packed by high quality plywood crate, to reduce distortion in conveying; 2. Main beams, end beams and electric hoist are packed by plastic woven cloth. It can reduce abrasion when transport. Delivery: 1. If the size of whole Double beam box type two trolley gantry crane are suitable for container ship, usually by container; 2. If the size is too big, usually by bulk ship or by container after truncation; 3. Transport ways are based on reducing cost for you and keep the crane performance! FAQ 1. What's the information should I provide when inquiry? a: Lift capacity. b: Lift height. c: Span. d: Power source. e:Working environment. More details, better. If you have the drawing will be very better. 2. Operating methods for selection? A: Pendent controller with push buttons. B: Remote control with push buttons. C: Cabin control with joystick. 3. Can you provide the various lifting tools? Sure, we can provide any tools other specials you need, please tell us it when enquiry. 4. How to install the Double beam box type two trolley gantry crane? Our senior engineer can be your side to do the installation guide service and training. Moreover, our best sales can visit your country. 5. Safety device Overload limiter, Limit Switch (lifting and traveling), Interlock protection device, Buffer, Overhaul cage, Rail clear plate, Protective cover, Bus bar preventer plate, Anticollision device, Main isolating switch, Emergency stop system, Motor overload protection, and so on.
SK200-8 Excavator J05E Engine Parts VHS227621070 S2276-21070 Common Rail Pressure Sensor.The fuel rail sensor, commonly referred to as the Fuel Pressure Sensor, it is installed at one end of the oil rail to measure the fuel pressure in the common rail pipe. The sensor is a part of vehicles fuel system and designed to monitor the fuel pressure that is present at the fuel rail.It sends this signal to the ECU, which then uses it to make adjustments to the vehicle s fuel and timing. When the sensor has an issue it can cause problems with the performance of the vehicle. Quality Guarantee :1 year, and strictly in accordance with the standard quality inspection The products are 100% new and carefully packed.