Product Description Pyrogenic Free treatment of PRP tube : KEALOR PRP tubes : As known, PRP tubes must be sterilized in order to ensure the safety during used for PRP therapy, but the normal glass tube will be changed to brown color after irradiation sterilization, KEALOR brand PRP tubes are used specifical glass material, that can be sterilized by Co. 60 Ray and tube is still transparent . Professional Gel: KEALOR PRP tubes are developed by our technologist, the gel is different from normal gel, special proportion, density and will not dissolved in blood. Easy to use: It is convenient to use and can complete extraction in 10-20 minutes. In fact, in China, only a few companies are authorized to produce PRP extraction devices, and our products come from one of them. Skin Care after PRP Treatment 1.the injection site within a few days after inje may appear slightly swelling, bruises, this belongs to the normal phenomenon, can fade in about three days, need not nervous. 2.treatment for 15 days, please avoid taking non-steroidal anti-inflammatory drugs, antipyretic analgesics, such as aspirin, he will receive, helped him Lin, etc. 3.please don't swim in a week after treatment, sauna, etc. 4.please pay attention to your diet, and within a week after treatment, no drinking, eating seafood and excitant food.
PRP Vacuum Blood Collection Tubes.
PRP tubes.
Inconel Instrumentation Fittings are made from an austenitic alloy that contains chromium and nickel in their composition. The addition of these elements in their alloy enables Inconel Instrumentation Fittings to be extremely resistant to corrosion and oxidation. Inconel Instrumentation Fittings hold their integrity even in extremely high temperatures. corrosion is a serious issue for clients who use instrumentation findings in environments rich in corrosive elements. As a result, Inconel Instrumentation Fittings is an ideal choice as they can withstand these environments. With an increase in the amount of titanium and niobium content, the alloy can significantly be strengthened by the heat treatment process. Inconel alloy offers high strength along with corrosion resistance. When heated, these fittings create an oxide layer that protects them from the corrosive environment. Because of its corrosion resistance, Inconel Instrumentation Fittings would be an ideal choice in harsh environments. The compounds in the alloy act like an adhesive at the grain boundaries. When the material is heated to a high temperature, this adhesive prevents the size of the particles from expanding (smaller particles are stronger and larger particles are more ductile). In comparison to stainless steel, Inconel Instrumentation Fittings have significantly higher corrosion resistance and strength at high temperatures. In cryogenic circumstances, stainless steel outperforms Inconel. Specification of Inconel Instrumentation Fittings Imperial Size 1/2 to 2 Size 1/16 OD to 2 OD, 2mm OD to 50mm OD Thread NPT, BSP, BSPT, UNF, ISO, SAE, MS, AN, weld ends etc. Pressure Rating 6000PSI for Stainless Steel, 300/1000/3000PSI for Brass Temperature Ratings Up to 1000 F (537 C) Types Tube to Union, Tube to Male, Tube to Female, Instrument Pipe Fittings, Accessories Application Power/ gas/ petroleum/ chemical/ metallurgy/ shipbuilding etc. Our service Nace Mr 01 75 Sour Service Impact Test As Per Ug 84 Macro Structure Analysis Hydrogen Induce Cracking Test (Hic) Sulphide Stress Cracking Test (Sscc) Cryogenic Services (Cryo),hydrogen Services (H2) Helieum Leak Test Dye Peniterant Test (Dp) Magnetic Partius Test (Mp) Post Weld Heat Treatment (Pwht) Ultrasonic Test (Ut) Hydro Test, Etc. Test Certificates EN 10204/3.1B Raw Materials Certificate 100% Radiography Test Report Third Party Inspection Report, etc Production Technique Forged/ Heat treated and machined
Blood Collection Tube 1. Whole Blood Tube 1.1 ESR Tube 1.2 K2 EDTA tube 1.3 K3 EDTA tube 1.4 ACD Tube. 2 Serum Tube 2.1 Plain Tube without Additive 2.2 Tube with Clot Activator 2.3 SST Tube. 3 Plasma Tube 3.1 Glucose Tube 3.2 Coagulation Tube 3.3 Sodium Heparin Tube 3.4 Lithium Heparin Tube Available size: 13*75mm, 13*100mm, 16*100mm, 8*12mm.
Disposable plastic cpda-1 blood bag mainly compose collection bag,best sale bags and relevant anticoagulant. Single cpda-1 blood bag is used for collection, preservation and transfusion of whole blood, Multi-cpda-1 blood bag is mainly used for collecting whole blood land for separation, preservation and transfusion of red blood cell, plasma and platelet etc.
Led bulbs, led tvs, electricity wires, switches and home made pickles..
colostomy bag- Disposable One-piece open (hydrocolloid adhesive) colostomy bag. One piece system,drainable with hydrocolloid skin barrier. size:15 - 70mm 1.Curegard adhesive plate (Hydrocolloid) 2.Odor/noise-free pouch (beige/transparent) 3. Extra-thin nonwoven liner (single) 4. Pouch size: 15CM x 28.5CM 5.Plate size: DIA:10CM,thickness: 0.75mm 6.one clamp/5pc 20pcs/ mid-box packing
standard endotracheal tube A. without cuff Size: ID2.0--ID10.0 B. with cuff Size: ID3.0--ID10.0 X-ray opaque line. Clear markings for easy observation. Murphy eye design. Standard 15mm connector. Smooth cuff edges reduce trauma. High Volume low pressure cuff maintains good sealing.
Stethoscope: Single-head stethoscope Dual-head stethoscope Stainless steel stethoscope II Neonate And Baby stethoscope Acrylic stethoscope timing stethoscope Standard Sprague Rappaport Stethoscope Cardioligy Stainless Steel Stethoscope 1pc in a color box.
Specificationsbest diabetes insulin pump: 1.Dimensions: 78*52*20mm. 2.Accurancy of basal: 0.1/0.05u 3.Infsion frequency :2-6 times/hour 4.Minimun insulin capacity per time: 0.05u 5.Alarm mode : ring 6.CPU QTY: dual CPU 7.Reservoir: 305u 8.Infusion turbing interface : standard luer interface(positive and negative spin) 9.Water proof level:IPX7
Specifications: 1. Single use, sterilization By EO gas, non-toxic, non-pyrogenic 2. The barrel is transparent enough to help user observe the mixture and liquid flow easily. 3. The indelible graduation make the reading easy 4. The distance between finger grips and barrel is according to the ISO standard, It can guarantee an easy grip. 5. Sterilized by Ethylene, Oxide Gas( EOG) 6. Validity life: 5 years Production description: 1. Barrel and plunger: Made of medical transparent polypropylene. 2. Piston: Made of natural rubber or latex free pistion, they are internation strandard pistion 3. Needle: Strandard steel medical grade material 4. Neddle protector: Make of medical grade transparent PVC 5. Neddle come form NIPRO or KDL, It's very sharp 6. Packing: Individual package have polybag or blister, middle have polybag and box, strandard carton .
Specifications: Tube Voltage): 60kV Tube Current: 1mA Exposure Time: 0.02~2S Tube Focus: 0.3*0.3mm Frequency: 30kHz Battery: DC14.8V 6400mA Rated Power: 60VA Charger Input: AC100V-240V±10% Charger Output:DC16.8V Weight:2.2kg Size:138*165*185mm The distance from skin to cone: 130mm
Digital arm blood pressure monitor Features: Measuring range HV / LV: 0kPa ~ 37.3 kPa (0mmHg ~ 280mmHg) Pulse: (40~199) times / min Measurement accuracy Static pressure: ± 0.4kpa (± 3mmHg) Pulse: Reading the value within ± 5% Operating temperature (Wet) Temperature: 5 ? ~ 40 ? Humidity: 10% RH ~ 90% RH Resolution rate 0.1kPa(1mmHg) Measuring method Oscillometric Memory 90 groups Display:LCD display Body color:White Product Size:Long 153mm wide 90mm thick 48mm Weight About 380g (No battery) Power Supply 6V (AA.1.5V battery×4) Standard Accessories Dry battery4, manual
electroplating frame ,fixed armrests,fixed foot cares, solid front and rear wheels. 8'' PVC castor and 24'' solid wheel Weight capacity:100kg
Vacuum Blood Collection Tube introduced by us promises to live up the expectations of the buyers. It is manufactured completely in clean room environment by using the best of the quality materials and assembled on a 100% Automatic assembly Line. We believe in quality and the same has been inculcated in our products. We produce the tubes in two volumes 13 75 mm and 13 100 mm. Variants : K2 EDTA (2 ml - 6 ml) K3 EDTA (2 ml - 6 ml) Clot Activator (2 ml - 6 ml) Sodium Heparin (2 ml - 6 ml) Lithium Heparin (2 ml - 6 ml) Sodium Fluoride (2 ml - 6 ml) Sodium Citrate (2 ml - 6 ml) Gel with Clot Activator (3.5 ml - 5 ml) We follow the colour codes of ISO 6710:2016 for the manufacturing process of the tube.
Prp tubes ( pharma).
Blood bank equipment , laboratory items , plasma extactor , vdrl shaker , centrifuges , plasma refrigerator , blood bag shaker , tube stripper , extractor , stirrer , rotator , cooling centrifuges , collection monitor , ultra low freezer , blood donor chair , humidity chambers , water bath , gerber centrifuges , vaccum oven , cold cabinets , research centrifuges ..
PRP tube.
SODIUM CITRATE Trisodium citrate is used as an anticoagulant for coagulation investigations. It works as an anticoagulant as it forms complexes with metal ions such as calcium inhibiting the coagulation cascade. Anticoagulation with trisodium citrate is reversible. LYBCON Vacutainer Citrate tubes contain buffered citrate in accordance with recommendations: 0.105 M or 0.109 M of buffered trisodium citrate solution, equivalent to 3.2% trisodium citrate The blood to additive ratio is 9:1. The citrate solution in the acts as LYBCON Vacutainer a buffer. Therefore, no additional buffer substances are added as these can adversely affect laboratory analysis. LYBCON Vacutainer Citrate tubes are also suitable for carrying out special test procedures such as the platelet function test PFA-100. Special tubes and the associated additional costs are therefore unnecessary. FILL LINE MARKING The significance of the correct ratio of blood to additive for coagulation samples is well documented. The correct fill amount is critical for correct coagulation analysis. All LYBCON Vacutainer coagulation tubes have a mark indicating the minimum fill level. CENTRIFUGING CONDITIONS For coagulation analysis different plasma specifications can be obtained from the citrated blood. Platelet rich plasma:150-200g for 5 minutes at 18-25 C Platelet poor plasma:2000-2500g for 10-15 minutes at 18-25 C Platelet free plasma: >3000g for 15-30 minutes at 18-25 C MIXING RECOMMENDATION Citrate tubes should be gently inverted 180 and back 3-4 times. SPECIFICATION Specimen: Plasma or Whole Additive: Sodium citrate 3.2% or 3.8% (9NC) Cap color: Blue Tube Size: 13x75mm Draw Volume: 1.8mL, 2.7mL Max. draw volume Tolerance: ±10%