Technical parameters: - Voltage ranges from 200 V up to 1000 V, - Current ranges from 200 A up to 20 A, - Frequency ranges from 20 Hz up to 100 kHz, - Resistance from 1 up to 19 M, - Voltage accuracy from 35 ppm, - Current accuracy from 150 ppm, - Ample software, - High output load, - RS 232C , IEEE488 interfaces. The INMEL 7000 calibrator is device with very high precision and simultaneously high load, thanks that it pulls ones weight very well with checking modern type as well older types of meters. It is characterized elastic and open systemic structure. We offer varius version of this calibrator from very simple e.g the DC voltage calibrator up to full configuration : DCV, DCI,ACV,ACI and R. Thanks to ergonomic desc and rich internal software the INMEL 7000 calibrator is very handly. In calibrator INMEL 7000 used modern construction solution, in which used new generation of electronics elements of renowned worldwide companies. Thanks that ones received very good metrological parameters, reduced quantity of compnents, and in this way augment the reliability of this calibrator. Application: Checking and calibration: - AC and DC voltmeters, - AC and DC ammeters, - frequency meters, - measuring transducers, - ohmmeters.
Technical parameters: - Voltage ranges 0.2 do 1000 V, - Current ranges od 20 mA do 20 A, - Frequency ranges od 40 Hz do 5000 Hz, - Voltage and current accuracy DC 0.02%, - Voltage and current accuracy AC 0.05%, - Load carrying capacity 40 VA, - Serial interface RS232, USB, Ethernet. The INMEL 1000 calibrator was made on base of modern componenets of microprocessor technologies. Applicated technologies are comparable with technologies used by leading global companies.The INMEL 1000 calibrator characterize oneself the innovative structure of operation in range of output signals and operation of measuring and regulatory loop.For AC course possible is the synchronous operation with the main. This possibility influence on output parameters, reliability, comfort of work, the communication way with user and external devices. The calibrator INMEL 1000 fulfils directives of the European Union within the range safeties and the electromagnetic compatibility:The production of the INMEL 1000 calibrator does not create threats for environment. Application: Checking ang calibration: - AC and DC voltmeters, - AC and DC ammeters, - frequency meters, - measuring transducers.
Parameters: - voltage measure: 0 100mV, 0 10V, - current measure: 0-24 mA, - voltage generation: 0 100 mV, 0 10V, - current generation: 0 24 mA, - voltage accuracy: 0.02% + 2 digits, - current accuracy: 0.015% + 2 digits, - loop power output: 24V Calibrator INMEL 50 integrate generation and measurement function of electric signals, used in automatic industry. The main features of this devices is high accuracy and resolution of generating or measuring signals, friendly operation and large display. Application: Checking and calibration: - measuring transducers, - measuring and control lines, - current loop.
DTDL-8110 Cablefault Test Set is an integrated set of Cablefault Detection and Location Devices. It is applicable for many types of power cable, communication cable and optical cable. It can accurately measure the distance of cablefault and locate the fault point. The system includes: 1) DTDL-8110 Mainframe. 2) DTDL-8032R Receiver. 3) RF Inductive Tracking Rod. 4) Potential Difference Locating Rack with 2 pins. 5) AF Stethoscope and Headphones (for Listening mode). 6) Grounding Pin.
Parameters WEW-100 Accuracy 1% of indicated value Measuring range of force(kN) 2-100kN Subsection of force 1,2,5,10 Accuracy of deformation measurement 0.5%F.S Clamping diameter for round specimen(mm) ;6-22 Clamping width of flat specimen(mm) 40 Clamping thickness of flat specimen(mm) 0-15 Testing space Tension 550 Compression 500 Platen size 100 Distance of bending by pass roll(mm) 30-400 Piston stroke(mm) 250 Power supply : 50Hz Working environment Room temperature : relative humidity Overall dimension(mm) Frame machine730x500x2000 Control System 1070x810x1730 Weight(Kg) 1370
Digital control hydraulic compression testing machine 1. Maximum Testing Load: 600kN 2. Measuring Range of Load: (24-600) kN 3. Accuracy of Testing Load: 1% 7. Distance between Upper and Lower Platen: 225mm (Adjustable) 8. Size of Upper Compression Platen: 180mm 9. Size of Lower Compression Platen: 250mm 10. Piston Ram Stroke: 150mm 11. Power Supply: three phase, 380/220V;50/60Hz 12. Working Environment: 80% Overall dimension: Frame: 1120, 1650(MM) Weight: Frame:950kg
1. Maximum Testing Load: 2000kN 2. Measuring Range of Load: (80-2000) kN 3. Accuracy of Testing Load: 1% 4. Rate of Loading Speed: 0.5N/s~10kN/s 5. Accuracy of Rate of Loading Speed: 5% 6. Accuracy of constant testing Loading: 1% 7. Distance between Upper and Lower Platen: 500mm (Adjustable) 8. Size of Upper Compression Platen: 230;280mm 9. Size of Lower Compression Platen: 230;280mm 10. Piston Ram Stroke: 200mm 11. Power Supply: three phase, 380/220V;50/60Hz 12.Working Environment: 80% Overall dimension: Frame: 1115 Control System : 187; Weight: Frame:4850kg, 200kg
his series testing machine is suitable for tensile, compression, bending, shearing, peeling and tearing test of metal and nonmetal materials, such as rubber, plastic, electrical wire and cable, composite, profiled bar, bar metal, board, spring, components and so on. It confirms to ISO 75001ú¼ASTM A370, ASTM E4 ASTM E8 and JIS, DIN, BSEN testing standards. AD800 in this machine is whole digit multi center closed loop measuring and control system. It adequately absorbs advanced functional characteristics and integrates the latest international professionally developed measuring and control system. Control software can automatically finger out routine data, such as tensile strength, yield strength, modulus of elasticity, extend rate after rupture, non-proportional extend strength RP0.2, etc. It can adopt many kinds of controlling modes, such as constant force, constant displacement, constant deformation, and real time display many testing curves of force-displacement, force-time, stress-strain. These curves automatically switch. Testing process control and data processing conform to the requirements of International standards. This machine is beautiful, multifunctional, safe and easy. Parameters: WDW-1 WDW-2 WDW-5 Maximum force: 1KN 2KN 5KN Accuracy: í_í+1% (0.5% as special order) Measuring range of force (KN): 0.2%--100%FS Resolution of force: 1/200000 of maximum force and no subsection of all scale Accuracy of displacement measuring: í+0.5% Resolution of displacement: 0.03ª¦m Speed adjusting range of displacement: 0.001-500mm/min Accuracy of deformation measuring: í+0.5% Range of deformation measuring: 2%í½100%FS Speed adjusting range of force; 0.005-5%F.S / S Speed controlling accuracy of force: ¿Qí+2.0% of the set value (speedú+0.05%FS/S) ¿Qí+0.5%/í+1.0% of the set value ( speed¿R0.05%FS/S) Speed adjusting range of deformation: 0.005-5%FS/S Speed controlling accuracy of deformation:¿Qí+2.0% of the set value (speedú+0.05%FS/S) ¿Q í+0.5% of the set value ( speed¿R0.05%FS/S) Valid tension testing space: 800 Compression testing space: 700 Clamping sample: Flat and round sample Power supply: 380V/220ú¼50/60Hz Working environment: Room temperature 10íµí½30íµ, relative humidityí_80% Base configuration : Panasonic servo motor, precision photoelectric encoder Weight(Kg): 300
Test load: 0.098N (10gf), 0.246N (25gf), 0.49N (50gf), 0.98N (100gf), 1.96N (200gf), 2.94N (300gf), 4.90N (500gf), 9.80N (1000gf) Leus/indenter switch: With hand Turret Carriage control: Automatic loading and unloading method Magnification of microscope: For measurement: 400X (Object lens 40x , eyepiece 10x) For observation:200X (object lens 20x, eyepiece 10x) Load holding time: 5-60 second Measuring microscope: Min measuring unit: 0.0625um Testing field: 1-2967HV Micro test table: Dimensions 100x100mm Movement: 25mm in X&Y axis Max. height of specimen: 70mm ; Max. depth of specimen: 95mm Output: Installed with innner-printer and RS232 interface ; Power Supply: AC110V/220V 60/50HZ Dimensions: (L ) 425 X (W) 245X (H)490mm; Gross Weight:: 42KG, Net Weight: 35KG
2m transmission analyzer Basic functions 2m measurement Hdb3 and ami line codes Out-of-service 2mb/s, n*64kb/s ber testing In-service framed and unframed double-channel testing Pcm simulator''mode testing Frame data control and monitoring Timeslot activity monitoring, fas, n-fas, ts16mfo analysis Built-in 64kb/s tone channel listen capability Cas and ccs signaling generation and monitoring Round trip delay measurement Aps delay measurement Extensive error and alarm generation Vf tone generation and measurement Level measurement Pulse mask measurement Jitter measurements to itu-t standard o. 172 Frequency and offset measurement Clock slip measurement Up to +/-999ppm transmit clock deviation Clock source: internal, interface or external 2m clock/signal Real-time transmit circuit open/short indication
Product Description TLD1500 Series is high quality of Optical Fiber Checker. It contains the most advanced laser technology and microelectronics technology, and can be measured with various fiber optic adapter with 2.5mm common Interface. It is very convenient for them to check the single-mode and multimode fiber. Features High visible red laser output Easy-to-use "quick access" interface Small size, light weight, high reliability Battery for power supply Suitable for all 2.5 mm optical fiber connector Applications Fiber production and research devices Fiber network testing and maintenance Optical communication teaching and test
Six impact devices are available for special applications(d, dc, d+15, c, dl, g) Direct display of hardness scales hrb, hrc, hv, hb, hs, hl; Software to connect with pc and dataview for pc operation; Automatic identification impact devices and test direction (except g); Software data and upperlower limits setting and sound alarm; Time and date setting; auto-clock; On-board memory holds 240-1000 groups of data; Integral thermal printer, print all test results and histogram; For all metallic materials; Li battery , low voltage indication and sound alarm; Lcd with blue back-light, showing all functions and parameters; Wide measuring range; Long standby time and stable performance of field work;
Introduction Dj-500p demagnetizer has the biggest demagnetizing surface at the flat demagnetizer. It is the leading level at the demagnetizer surface, power consumption and work efficiency in china. It can produce a damping magnetic field.And it need not move the workpiece during demagnetizing.Based on fully taking into account demagnetisers reliability andstability , the design and special selection of materials make dj-500p type demagnetizer to be widely used. Dj-500p demagnetizer do not pollute the powerline.Large parts, large devices (such as calipers, needles, screws, nuts, change knives, scissors, blade) can be demagnetized easily. Major technical character 1. Application: magnetic metal parts and molds. 2. Demagnetized voltage (v): ~~ 380v 3. Demagnetized time (s): 2-5 s 4. Demagnetized area (mm): 500 ~{!a~} 500 5. Residual flux:
1.1 General introduction APVA-403 CT analyzer is special tester for current transformer. It takes IPC as core to sample and data process. The instrument finishes CT tests based on different low frequency. It has 8.4 inches LCD to display and a 8.4 inches touch pad for operation. The tester has the characteristic of high precision, strong anti-jamming and easy operation. 1.2 Functions 1. Excitation curve, volt-ampere curve and error curve drawing 2. Second burden measurement 3. CT coil DC resistance measurement 4. CT transformation ratio test 5. CT phase polarity test 6. Automatically make WORD and EXCEL test report. 1.3 Technique index 1. transformation ratio test error
1.1 General introduction APLB-601 is an instantaneous signal recorder used for kinds of industry. It takes IPC as the core to sample and data process. It has 12.1 LCD to show, touch pad for operation, strong anti-jamming and easy operation. 1.2 Functions 1. Sample isolation between channels completely. 2. The instrument software has waveform zoom, data statistics, spectrum transformer and wavelet transformer tools. 3. Lots of test template to make customers finish test rapidly. 4. All the data can be exported through U-disk or wireless network. 5. Automatic upgrade interface of the tester make it easy to get latest software package and test template. 6. 12.1 LCD to show, touch pad for operation. 7. Automatically makes WORD and EXCEL test reports. 1.3 Technique parameters 1. Analog signal sample channels:12 2. Optional stalls: -450V~450Vú¼-100V~100Vú¼~10V~10Vú¼-20mA~20mA 3. Sample error: -450V~450V error
Sensitivity 0.1 ppm Accuracy 2 % Response T90 = 1 sec
Accuracy or tolerance ¦ when valve 20ppm1ppm While > 20ppm 10% Oil sample ¦50ml2ml gas sample ¦ 5ml0.2ml
PE-AOBDV Automatic Oil Breakdown Voltage Testeris a highly precise instrument, which can be applied to measure either the breakdown voltage or also check the withstanding voltage for a predefined time. Usual available automatic test sets only perform the former function, but PE-AOBDV can do both. PE-AOBDV can measure the breakdown voltage repetitively and computes an average reading, for a proper decision making. PE-AOBDV consists of an integrated Oil Cup, HV AC power source. Features - 0-80kV or 0-100kV smooth operation, 5mA trip current - Complete Automatic operation - Non-contact magnetic stirring - Programmable Stir, Hold, and Intermediate Stand times - Programmable voltage ramp rate - Repetitive test sequence and average readings - Digital display output - Integrated thermal Printer - Internal memory for data storage and recall - Included IS 6792, IEC 60156 and GB507-86 test sequences - Programmable test sequences as per requirement. 1 pc - 25 kgs.
Specifications Function AC leak currentú¼high-harmonic currentú¼0n line current testú¼phaseíóelectrical energyú¼power factor revise Test mode Clip-onCT Output mode Current mutual inductance output uA/mAú+mA/A or voltage output mV/mAú+mV/Aú¿lectotypeú¬ Dimensions Widthí-heightí-thicknessú¦64mmí-160mmí-23mm Clamp mouth ª+40mm Wire length 2.0mú¿by orderú¬ Measure range AC 1uAí½80Aú+10uAí½300Aú+10mAí½600Aú¿lectotypeú¬ Resolution 1uAú+10uAú+5mAú¿lectotypeú¬ Accuracy 1% ú+2%ú¿50Hzú+25íµí+3íµú¬ú¿lectotypeú¬ Linearity degree 1% ú+2%ú¿50Hzú+25íµú¬ú¿lectotypeú¬ Work frequency 10í½100KHz Wire voltage Line test under AC600V Quality About120g Working temperature and humidity -25íµí½70íµú+below 80%rh Storage temperature and humidity -10íµí½60íµú+below 70%rh Insulation AC2kV/rms (between core and box) Applicable safety rules IEC1010-1íóIEC1010-2-032íópollution, etc 2íóCAT ó=(600V).
Specifications Function AC leak currentú¼high-harmonic currentú¼0n line current testú¼phaseíóelectrical energyú¼power factor revise Test mode Clip-onCT Output mode Current mutual inductance output uA/mAú+mA/A or voltage output mV/mAú+mV/Aú¿lectotypeú¬ Dimensions Widthí-heightí-thicknessú¦138mmí-42mmí-20mm Clamp mouth ª+7.5mm Wire length 2.0mú¿by orderú¬ Measure range AC 1uAí½10Aú+ 5uAí½20Aú+10uAí½50A Resolution 1uAú+5uA ú¦10uAú+ú¿lectotypeú¬ Accuracy 0.1-0.2ú¿50Hzú+25íµú¬ Ungraded load í_50ª+ Work frequency 10í½100KHz Wire voltage Line test under AC600V Quality About175g Working temperature and humidity -25íµí½70íµú+below 80%rh Storage temperature and humidity -10íµí½60íµú+below 70%rh Insulation AC2kV/rms (between core and box) Applicable safety rules IEC1010-1íóIEC1010-2-032íópollution, etc 2íóCAT ó=(600V).