Ace DLX Features Extra Powerful motor for high air thrust Optimum performance even at low voltages 2 year warranty Technical Specification Sweep(MM) 1200 Speed(RPM) 390 Power(Watts) 75
There are various types of electric fan such as desk fan, stand fan, oval fan, and industrial fan.
Specification 1.Working voltage: 12V,24V 2.Static pressure: 100Pa 3.Air volume: 1700m3/h, 2000m3/h, 2200m3/h 4.Curved blades and straight blades 5.Pull type and Push type with various dimension
Electrical fan We have a variety of model available to you for information, pls tell us and send the details for you.
Oscillation; with timer; 3 speed setting; ABS switch box; With overheat cutoff protection
Electric fans Voltage:220v-240v/50-60hz Power:20w Size:300mm Wind:34m3/hr Lighting time:360hrs With warning function Packing:1pc/ctn Meas:41*19*61cm The storage battery :12a
Electric fan Standard packing
Stan fan, stand table fan, table fan, box fan, industrial fan, mini fan, floor fan
Electric fan Available in 85mmx85mmx145mm size Packing: 30 pcs/carton box, 20,000 pcs/20' container
Auto A/C blower fan motor for Cat Caterpillar JCB 4178129 417-8129 335E9706 12V Item HY-FM177 Details TUYoung ID: HY-FM177 Specification Voltage: 12V OEM NO.: 4178129 CA4178129 417-8129 335-E9706 335/E9706 335E9706 1000361066 Suitable for Caterpillar 428F2 excavator fan blower motor JCB heater motor fan
We are one of the highly trusted names in the industry well-known in offering a superlative grade spectrum of Electric Fans for its application in schools, offices, households, factories, showrooms, shops and industries. These are highly demanded by our clients owing to their reliability and flawless performance. We are deal in Cabin Fan, Ceiling Fan, Exhaust Fan, Heavy Duty Metal Exhaust Fan, Table Fan, Pedestal Fan, Ventilation Fans and Wall Fans with superior quality and best price.
BRAND: NICOTRA I GEBHARDT PRODUCT: A/C BLOWER FAN MODEL: RDH-E2-0200 COD-6E21022ZZ0000000/15 3000WATT 6000 RPM
Insulation Double Insulated Air Volume 3.8m3/min Rated Voltage 235V AC Watts Input (full Load) 600 W No Load Speed 6000-16000 r.p.m. Full Load Current 2.55A Approx Net Weight 1.8 kg. Dual function with blowing and suction applications Powerful 600 W motor Air flow of 3.8m3min for superior cleaning performance Variable speed control with 6 step speed settings provides Extra versatility in different applications Ergonomic handle Light Weight
MODEL RB 500 Capacity 3.8m 3 / min Watts Input (full Load) 600 Watts No Load Speed 6000 - 16000 r.p.m. Approx Net Weight 1.8 kg. Variable speed Light weight Portable Double insulated
Type: Axial Flow Fan Applicable Industries: Hotels, Building Material Shops, Food & Beverage Factory, Restaurant, Home Use, Food Shop, ETC. Electric Current Type: AC Mounting: Duct Fan Blade Material: Plastic, Plastics Place of Origin: China Brand Name: Deflecto or OEM Model Number: HQ-S Voltage: 220~240V Power: 12W / 18W Certification: CE, ROHS, ISO9001 Material: ABS Size: 100mm/ 150mm Color: White Noise: 34~35dB Air Volume: 78CFM / 188CFM Frequency: 50Hz-60Hz Motor Material: Copper
Product description High-temperature fans are generally used in kaji furnace, high-pressure forced ventilation and the transport for meterials , wind and non-corrosive, not spontaneous, non-explosive, gluten-free gas. Product feature 1.High efficiency, low noise, easy operation 2.Adjustable blades Application High-temperature fans are generally used in kaji furnace, high-pressure forced ventilation and the transport for meterials , wind and non-corrosive, not spontaneous, non-explosive, gluten-free gas. Other information Export records Saudi arabia, vietnam, south korea, india, philippines, iran and so on
Product description High-temperature fans are generally used in kaji furnace, high-pressure forced ventilation and the transport for meterials , wind and non-corrosive, not spontaneous, non-explosive, gluten-free gas. About product feature:high efficiency, low noise, easy operation ;adjustable blades High-temperature fans are generally used in kaji furnace, high-pressure forced ventilation and the transport for meterials , wind and non-corrosive, not spontaneous, non-explosive, gluten-free gas. Zibo dingxian mechanical equipment co., ltd which was founded in 1985, mainly designs and manufactures centrifugal fans and axial flow fans which are applied to industrial systems, which is the senior member of china general machinery industry association (cgma). As one of the main large fan manufacturers in north china, which owns more than 200 employees and the production capacity of 15000 sets one year, we have an advanced air flow test laboratory in our company. We master mature fan designing, testing, manufacturing technology, and can design and manufacture multipurpose fans according to users' requirements. So, we are able to meet users' complex and professional applications.
Product Characteristics Model:9-19,9-26 Flow:824-123090m3/h Pressure:3253-16250Pa Rotation speed:960-2900r/min Power:2.2-850KW Transmission Way:A type(4~6.3)and D type(7.1~16) The 9-26 centrifugal fan belongs to single suction,could be made two kinds as right-handed and left-handed.Front view is taken from the end of motor,if the impeller turns clockwise,it is called right-handed ventilator,expressed by "Right";if it turns counterclock wise,called left-handed ventilator,expressed by "Left". The air outlet position is expressed by the air outlet of shell."Clockwise"and "anticlockwise" could be made into totally six angles such as 0°,45°,90°,135°,180°,225°.
3. Product characteristics Model: 2.8,3.2,3.6,4,4.5,5,6,6.3,7,8,10,12.5,16,20,etc. Transmission way: 2.8~5(A type);6~12.5(C,D,E type);16~20(B type) Flow: 565-239654 m3/h Pressure: 166-3863 Pa Power: 0.55-220 KW Rotating speed: 250-2900 r/min 1. Product Introduction Model 4-72 centrifugal blower is applicable in ventilating and conveying air and other gases that non-flammable, non-explosive, non-volatile, harmless to the human body, non -corrosive to steel in general factory and large buildings indoor. B4-72 centrifugal blower can be used for pumping flammable and volatile gases.F4-72 model is mainly used for conveying corrosive gases.But there must be no any sticky substance in the gases that Model 4-72,B4-72,F4-72 centrifugal blower conveys, and the dust and hard particles contained no more than 150mg/m3. Gas temperature should not exceed 80ºC.
The fan is divided into an axial flow fan, a centrifugal fan and a diagonal flow (mixed flow) fan according to the flow direction of the airflow after entering the impeller. The fan can also be divided into single-stage, two-stage or multi-stage pressurized fans according to the form of pressure. For example, 4-72 is a single-stage pressurization, and a high-end fan is a multi-stage pressurized fan. Fans can be divided into: axial flow fans, mixed flow fans, roof fans, air conditioning fans, etc. according to the purpose. The fan can be divided into a negative pressure fan, a low pressure fan, a medium pressure fan and a high pressure fan according to the pressure. According to the outlet pressure (boost), it is divided into: fan (â?¤ 15,000 Pa), blower (1.5 to 350,000 Pa), compressor (â?¥ 350,000 Pa) [7]. Sort by layer There are many classification methods for ventilators, which can be roughly classified by the following types: (1) According to the level of pressure generated, it can be divided into: volumetric type: reciprocating type and rotary type; turbine type: centrifugal type, axial flow type, mixed flow type and cross flow type, and jet type. Fans generally refer to turbine type, ie, centrifugal, axial, mixed flow, cross flow, and the like. [1] Its main features are: Centrifugal fan: higher pressure, but less air. Axial fan: Higher air volume, but lower pressure. Mixed flow fan: The air volume and pressure are between the centrifugal and axial fans. Cross-flow fan: It has a high dynamic pressure and can get a flat air flow. (2) According to the different materials used, it can be divided into: iron shell fan (common fan), fiberglass fan, plastic fan, aluminum fan, stainless steel fan, etc. (3) According to the direction of gas flow, it can be divided into centrifugal type, axial flow type, diagonal flow type (mixed flow type) and cross flow type. (4) The flow direction after entering the impeller according to the airflow can be divided into: axial flow fan, centrifugal fan and diagonal flow (mixed flow) fan. (5) According to the application, it can be divided into: the push-in partial fan and the explosion-proof motor are placed outside the flow channel or in the flow channel, and the explosion-proof motor is placed in the explosion-proof sealed cavity. (6) It can also be divided according to the form of pressure: single-stage, double-stage or multi-stage pressure fan [1].