The tile design in the image features a soft beige to cream base with subtle variations in tone, giving it a natural and elegant appearance. It has delicate veining patterns that mimic the organic flow seen in natural stone, particularly marble. The veins are light, mostly off-white, with occasional hints of gray and faint earthy undertones. These lines and patterns are sporadic, adding depth and texture without overwhelming the surface. This tile would be ideal for creating a luxurious yet understated look in interior spaces, offering a timeless aesthetic. It is versatile enough for use in floors, walls, bathrooms, kitchens, or even large-format installations like feature walls. The overall effect is calming and neutral, allowing it to pair well with various interior styles, from modern minimalism to classic elegance. Tile size (in cm or inches): Standard sizes like 60x60, 80x80, etc. Finish: Polished, matte, or natural? Quantity: How many square meters or tiles are required? Location for shipping: Where will the tiles be shipped?
Turbine Flow Meters which have advantages of simple structure, light weight, high accuracy and easy installation, measure liquid which has no impurities and no chemical corrosive reaction with stainless steel . The measurable liquids include water , diesel and methanol, etc. FINE-FLOW FLOW METERS BY H&L FROM KOREA FEATURES Wide range of liquid measurement High accuracy and excellent repeatability Easy installation and energy saving Easy to read LCD Back light. Specific Gravity Correction 0.01 2.00 Display Accumulated amount reset, accumulated flow display, instantaneous flow rate display, gallon or liter unit change, automatic integration Lamp indication Flow display Battery life 4 5 years Auto on and off
White Sugar Icumsa 45 RBU, Brazilian White Sugar Specifications: 45 Icumsa rbu Attenuation index units Method # 10-1978 Ash content : 0.04% Maximum by Weight Moisture : 0.04% Maximum by Weight Magnetic particles : mg/kg 4 Solubity : 100% DRY & Free Flowing Granulation : Fine Standard Polarization : 99.80 Minimum Max AS : 1 P. P. M. Max OS : 2 P. P. M. Max CU : 3 P. P. M. Colour : Sparkling White Sediments : None SO : mg/kg 20 Reducing sugar : 0.010% Maximum in Dry Mass Radiation : Normal w/o presence of cesium or iodine SO2: Certified Substance : Solid, Crystal Smell : Free of any Smell Hpn Staph Aureus : per 1 gram Nil Microbiological limits : Pathogenic Bacteria including Salmonella per 1 gram Nil Bacillus per 1 gram Nil Pesticide tracing : Maximum mg/kg Basis DDT 0.005 Photoxin 0.01 Hexachloran Gamma Isomar 0.005 Crop: :2022 / 2023 or more recent crop Phytosanitary certificate of no radiation, no virus', no insect parts, no rodent excrement, no husks and no poisonous matter. Product is suitable for Human consumption. White Sugar Icumsa 45, Brazilian White Sugar
Overview SPECIFICATIONS: ICUMSA : 45 RBU ICUMSA Attenuation index units Method # 10-1978 ASH CONTENT : 0.04% Maximum by Weight MOISTURE : 0.04% Maximum by Weight MAGNETIC PARTICLES : mg/kg 4 SOLUBILITY : 100% DRY & Free Flowing GRANULATION : Fine Standard POLARIZATION : 99.80 Minimum Max AS : 1 P.P.M. Max OS : 2 P.P.M. Max CU : 3 P.P.M. COLOUR : Sparkling White SEDIMENTS : NONE SO : mg/kg 20 REDUCING SUGAR : 0.010% Maximum in Dry Mass RADIATION : Normal w/o presence of cesium or iodine SO2: Certified SUBSTANCE : Solid, Crystal SMELL : Free of any Smell HPN STAPH AUREUS : per 1 gram NIL MICROBIOLOGICAL LIMITS : Pathogenic Bacteria including Salmonella per 1 gram NIL Bacillus per 1 gram NIL PESTICIDE TRACES : Maximum mg/kg Basis DDT 0.005 PHOTOXIN 0.01 HEXACHLORAN GAMMA ISOMER 0.005 CROP: :recent crop Refined ICUMSA 45 TO 1200 Sugar. Refined Beet Sugar.
Input voltage: 12v Work voltage: 8-18v Outpt voltage: 1-5v Response time:
Process connection as per ASME / EN / AWWA / JIS 3 line LCD backlit display SS construction Bidirectional flow Multiple communication protocols Built-in diagnostics"
Inert Gas Flow Meter
The RBBF Clamp-on Ultrasonic Flow Meter is a fixed-mount, low cost transit-time ultrasonic flow meter with clamp-on transducers for non-invasive liquid flow rate measurement. Our microprocessor-based, user friendly field programmable creates no interruption of the process flow and has low installation costs. This versatile series of flow meters is available in a variety of configurations. Available transducer types include clamp-on, in-line, and insertion. Wall-mount, panel-mount, pipe-mounted and compact din-rail mounted display types are also offered. Additional available features include pulse, 0-20mA & 4-20mA outputs, RS-232 communication, user-selectable engineering units, and a data logger function.
We can also provide the following products: Burkert flow transmitter Gf signet flow transmitter Foxboro flow transmitter Yokogawa flow transmitter Honeywell flow transmitter Coriolis flow transmitter Rosemount flow transmitter Siemens flow transmitter. -
We can also provide the following products: Burkert flow transmitter Gf signet flow transmitter Foxboro flow transmitter Yokogawa flow transmitter Honeywell flow transmitter Coriolis flow transmitter Rosemount flow transmitter Siemens flow transmitter -
We can also provide the following products: Burkert flow transmitter Gf signet flow transmitter Foxboro flow transmitter Yokogawa flow transmitter Honeywell flow transmitter Coriolis flow transmitter Rosemount flow transmitter Siemens flow transmitter
Residential Diaphragm Gas Meter ITRON (MID approved) Steel Version Basic Features 3 Compact size: 1.2 dm cyclic volume Range: G1.6, G2.5, G4 EN 1359 & O.I.M.L compliance Design Long -term accuracy & safety Ready for remote reading & data management Quality World-class, ISO9001 certified, European Engineering and Manufacturing APPLICATION The ITRON, with an installed base of over 30 million units, is a versatile meter that makes it the preferred choice of many large utilities world-wide. METROLOGY The ITRON meets O.I.M.L, EN 1359 and MID (certificate delivered by the LNE), and more than 25 national metrological standards (DVGW,NMI Class 1....). Its design and the careful choice of materials enable the ITRON to meet the highest demand in international markets in terms of accuracy and long-term stability. During the preliminary test controls on the sonic nozzle test benches, all meters are tested at Qmin, 0.2 Qmax and Qmax. OPERATING PRINCIPLE The ITRON is a positive displacement diaphragm gas meter with a stand-alone twin chamber measuring unit. The twin chambers are each fitted with a flexible and gas-tight diaphragm which is moved by the differential between the inlet and outlet pressure. The Gas enters one side of the diaphragm pan while on the other side it comes out through a separate port on the valve. When one side is full, the rotating mono-valve moves on to the next position, allowing the gas to fill the empty side. A transmission gear and a mechanical coupling or stuffing box transfer the reciprocating motion to the mechanical retrofitable index. The measuring unit is housed in a robust gas-tight casing. CONSTRUCTION With its casing in steel, high protection against corrosion is ensured by 500 hours salt fog spray test resistant cataphoresis treatment. The aluminum version can withstand up to 1000 hours salt fog spray test. The extreme strength of the case joint is achieved by rolling the belt & compressing the flanges into contact with a sealant applied between the faces. This forms a joint which is both gas-tight and fire- resistant. MEASURING UNIT The achievement of the fixed stroke mechanism is the result of precision and high quality automation, and eliminates the need for an adjustable tangent. This confines all registration adjustments to the accessible change wheels behind the index. The long life synthetic diaphragms, coupled to the well-proven movement design, combine to give excellent stability and accuracy during the whole life of the metre. All materials have been selected for their superior resistance to chemicals and gas. The valve and the grid, thanks to a special Bakelite formulation, enjoy high gliding properties and are protected against premature wear. Finally, a back-run stop prevents the metre from running backwards in case of tampering. INDEX The metres are available with metric or cubic inch indexes. They come with a permanent magnet for pulse generation and can be retrofitted with a pulse transmitter. Ip54 and Ip67 versions are available for specific environments. QUALITY ASSURANCE Quality assurance procedures- such as ISO 9001- and strict controls throughout the manufacturing process ensure a very high quality level. APPLICATION The ITRON, with an installed base of over 30 million units, is a versatile meter that makes it the preferred choice of many large utilities world-wide. METROLOGY The ITRON meets O.I.M.L, EN 1359 and MID (certificate delivered by the LNE), and more than 25 national metrological standards (DVGW,NMI Class 1....). Its design and the careful choice of materials enable the ITRON to meet the highest demand in international markets in terms of accuracy and long-term stability. During the preliminary test controls on the sonic nozzle test benches, all meters are tested at Qmin, 0.2 Qmax and Qmax. OPERATING PRINCIPLE The ITRON is a positive displacement diaphragm gas meter with a stand-alone twin chamber measuring unit. The twin chambers are each fitted with a flexible and gas-tight diaphragm which is moved by the differential between the inlet and outlet pressure. The Gas enters one side of the diaphragm pan while on the other side it comes out through a separate port on the valve. When one side is full, the rotating mono-valve moves on to the next position, allowing the gas to fill the empty side. A transmission gear and a mechanical coupling or stuffing box transfer the reciprocating motion to the mechanical retrofitable index. The measuring unit is housed in a robust gas-tight casing. CONSTRUCTION With its casing in steel, high protection against corrosion is ensured by 500 hours salt fog spray test resistant cataphoresis treatment. The aluminum version can withstand up to 1000 hours salt fog spray test. The extreme strength of the case joint is achieved by rolling the belt & compressing the flanges into contact with a sealant applied between the faces. This forms a joint which is both gas-tight and fire- resistant. MEASURING UNIT The achievement of the fixed stroke mechanism is the result of precision and high quality automation, and eliminates the need for an adjustable tangent. This confines all registration adjustments to the accessible change wheels behind the index. The long life synthetic diaphragms, coupled to the well-proven movement design, combine to give excellent stability and accuracy during the whole life of the metre. All materials have been selected for their superior resistance to chemicals and gas. The valve and the grid, thanks to a special Bakelite formulation, enjoy high gliding properties and are protected against premature wear. Finally, a back-run stop prevents the metre from running backwards in case of tampering. INDEX The metres are available with metric or cubic inch indexes. They come with a permanent magnet for pulse generation and can be retrofitted with a pulse transmitter. Ip54 and Ip67 versions are available for specific environments. QUALITY ASSURANCE Quality assurance procedures- such as ISO 9001- and strict controls throughout the manufacturing process ensure a very high quality level. Prepaid Gas Meter Sensus Meters satndars
1. accuracy :1% repeatability 0.5% cycle:500ms 2. OCT output 3. data interface :RS-232 4. DN: 15mmí¬6000mm 5. medium: temparature: 0-1600C 6.Turbidity: í_10000 ppm flow rate: 0~í+30m/s 7.power:AC220V ,DC8-36V ,AC7-30V Solid structure with die-cast aluminium enclosure Weight : 2.5Kg
Open Channel Flow Meters
Digital meter Digital meters Major technical parameter Basic error;0.5%fsa1db;resolving power;1, 0.1, 0.01, 0.001 Max.Display;1999;display;red digital tube Input;single terminal ;power supply;ac220v, 50/60hz Frequency;45~65hz(to ac);compression resistance;ac2000v/1min. Spill display;1or 1;insulation resistance;dc1000v100m Polar display;only display(to dc);weight;÷300g We can also produce the meters according to your drawings or models We can supply a variety of ammeter/wattmeter / shipped meter/current Transformers/voltmeter/shunt/regulator/frequentcy meter. Our company is an enterprise that produces setting style ammeters and accessories. It specializes in the production of ammeters for ac/dc current, voltmeters for ac/dccurrent, power meters, power factor meters, frequency metersm shunts, currenttransformers, and corresponding complements and fullset products. We have passed through the test of gb/t19001:iso9001:2000 quality management system.
X-meter mass flow meter
Water meter flow meters Porter:sales9@gnflowmeter.com Site:www.microflowmeter.com Skype:shcixi_ru water meter flow meters(mini oil water flow meter) principle is a liquid pushing one pair of oval gears; volume of each cavity is a fixed volume; gear speed leads, the sensor sends the sync pulse count, oval gear rotated by the magnetic seal coupling and reduction gear mechanism passed directly to the counter indicates the total flow through the meter. If the additional transmission means, the display of water meter flow meters together with electrical instrument can achieve remote only instantaneous flow or accumulated flow. The water meter flow meters with 0.2% accuracy and low flow range.the high temperature is 200C,the max pressure is 1000Bar.the output is pulse and material is stainless steel and aluminum. Model Flow range Connection CX-M2-SS/AL 0.5~150 ml/min G1/8 female thread CX-M3-SS/AL 1-300 ml/min G1/8 female thread CX-M5-SS/AL 5-1000 ml/min G1/8 female thread CX-M6-SS/AL 0.5-100 l/H G1/4 female thread CX-M9-SS/AL 5-550 l/H G1/4 female thread CX-M12-SS/AL 1~30 L/min G1/2 female thread CX-M25-SS/AL 5-110 l/min G1 female thread CX-M40-SS/AL 10-250L/min G1 1/2 female thread CX-M50-SS/AL 10-500L/min G2 female thread Feature 1) Compact and economical design suited for OEM 2) High accuracy and repeatability 3) No requirement for flow conditioning 4)Stainless steel rotors 5) Measures high and low viscosity liquids 6)Original Equipment Manufacturers Select the JSN and select the water meter flow meters,we will provide the professional service for you.
An ultrasonic flow meter is a type of flow meter that measures the velocity of a fluid with ultrasound to calculate volume flow. Using ultrasonic transducers, the flow meter can measure the average velocity along the path of an emitted beam of ultrasound, by averaging the difference in measured transit time between the pulses of ultrasound propagating into and against the direction of the flow or by measuring the frequency shift from the Doppler effect. Ultrasonic flow meters are affected by the acoustic pr
An ultrasonic flow meter is a type of flow meter that measures the velocity of a fluid with ultrasound to calculate volume flow. Using ultrasonic transducers, the flow meter can measure the average velocity along the path of an emitted beam of ultrasound, by averaging the difference in measured transit time between the pulses of ultrasound propagating into and against the direction of the flow or by measuring the frequency shift from the Doppler effect. Ultrasonic flow meters are affected by the acoustic pr
Product overview Hand-held ultrasonic flow meters enable non-contact measurement of liquid flow. The flow is measured by mounting the sensor on the outer wall of the pipe. It has the characteristics of small size, convenient carrying and accurate measurement. It is widely used in tap water, heating, water conservancy, metallurgy, chemical, machinery, energy and other industries. It can be used for production monitoring, flow verification, flow inspection, water balance adjustment, energy saving monitoring, and is an essential tool for real-time flow detection. Technical parameters Category Performance, parameters Host Principle Ultrasonic time difference principle Accuracy ±1% Display 48 Chinese or 416 Western-style dot matrix backlit LCD monitors, supporting Chinese, English, Italian and French. Signal output 1 channel OTC pulse output (pulse width 6~1000ms, default 200ms) Data interface The RS232 serial interface is isolated and the flowmeter can be upgraded via a PC. Pipe condition Pipe material All dense pipes such as steel, stainless steel, cast iron, copper, PVC, aluminum, and glass reinforced plastic are allowed to be lined. Pipe inner diameter 15~6000mm Straight pipe The sensor installation point is best to meet: upstream 10D, downstream 5D, Distance to pump outlet30D (D is the pipe diameter) Measuring medium Kind Water, sea water, industrial sewage, acid and alkali, alcohol, beer, various oils and other single average liquids that can conduct ultrasonic waves. Temperature -30�ºC~160�ºC Turbidity 10000ppm and small bubble content Flow rate 0~�±10m/s Working environment Temperature Host:-20C~60C Flow Sensors:-30C~160C Humidity Host:85%RH Sensor protection level IP67 Power supply Three built-in 1.2V rechargeable NI-MH batteries with a capacity of 2000AH, which can work continuously for more than 12 hours every time. Different measurement can be achieved by using the AC90~260V power adapter. Power consumption 1W Shell material Flame retardant ABS Host weight 390g