High frequency oscillatory ventilator , hfov , infant warmers, phototherapy, cpap, conventional ventilators.
Hospital furniture, electric ICU bed, electric ot table, medical ventilator, neonatal ventilator, ICU ventilator, ambulance ventilator, transport ventilator, bubble generating cpap, analysers.
ITEM D.S Viscosity Brookfield Purity PH Moisture FL6 Y0.7 70-100 Y98.5 6.5-8.5 ¨¹10 FL9 Y0.9 FM9 Y0.9 400-700 FH9 Y 0.9 FVH6 Y 0.7 800-1200 FVH9 Y 0.9 FBC-1 Y 0.8 1500-4000 FBC-2 Y0.9 Y2000 FBC-3 Y0.9 Y4000 Deli CMC is widely used in foodstuff industry. Among those acid resistant products, special measures are taken in selction of raw material, control of producing and its final products, which insures stability of our CMC. Our food grade cmc are widely used in various kinds of milky drinks, condiments. It plays a role of stabilization, taste improvement and thickening. Packaging Details: craft paper bags of 25 kgs per bag. container: 16000kgs with pallet or 18000 kgs without pallet. The products are stored in clean, dry and ventilated warehouse and shall never be mixed with toxic and smelly matters in package, storage and transportation. This product easily absorbs water so during transportation, it should be made sure that the package is waterproof. Shelf life: 2 years. Delivery Time:2 days after the payment of the buyers
BiPAP Ventilator Circuit Corrugated Tube 72 Inch Tube Single Limb Adult Without Breathing Bag Single Patient Use UOM: 10/BX Product Number: 312107 Manufacturer: Respironics
RT-Series Ventilator Circuit Corrugated Tube 60 Inch Tube Single Limb Adult Without Breathing Bag Single Patient Use Heated Circuit UOM: 10/BX Product Number: RT114 Manufacturer: Fisher & Paykel
The air ventilator manufactured by ambica engineering works functions without electricity, leaving no scope for any kind of shock or short circuit. It works by utilizing wind energy to induce air flow by centrifugal action. Huge choice of selecting ventilators is offered to our customers ranging from 16" to 36" diameter and of various material of construction for any working atmosphere. Our entire chain of products includes:
Tg-500b are used in the houses, the ventilating pipes and the small buildings. 1. The ball diameter (body diameter) is 620mm (25inch), and the throat diameter (inner diameter) is 500mm (20inch). 2. There are three kinds of materials they are made of: (a) stainless steel, (b) vanes stainless steel+ others galvanized sheet, (c) vanes aluminum + others galvanized sheet. 3. The volume of air discharge is about 950-4000 cbm/h. 4. It is about 8 kg/set and the ubc bearings we use are from the usa. 5. We guarantee the usage for 15 years. 6. We can design and manufacture other sizes according to your demands. 650mm*650mm*200mm
Ventilation modes: IPPV, A/C, PCV, SIMV, SPONT/CPAP, PSV, APRV, PRVC, BI-PAP Ventilator parameter ranges Tidal volume(Vt) 0 ~ 2000mL Frequency (Freq) Oxygen concentration 1bpm ~ 100 bpm 21%-100% I/E 4:1~1:8 PEEP 0cmH2O ~ 40 cmH2O Pressure Limit 20 cmH2O ~ 100 cmH2O Monitored Parameters Frequency (Freq) 0 /min ~ 100 /min Tidal volume(Vt) 0 mL ~ 2500 mL MV Airway pressure Dynamic lung compliance testing ETCO2 Concentration 0 L/min ~ 99 L/min 0 cmH2O ~ 100 cmH2O 1mL/cmH2O ~ 1000mL/cmH2O 0mmHg ~ 152mmHg (0%-20%) Oxygen concentration 15 % ~ 100 % Oscillographs display: P-T(pressure â?? time) F-T(flow â?? time) P-V loop (pressure â?? volume loop) V-T(volume time ) ETCO2-T (End-tidal CO2 - time) Alarms and protection The AC power failure alarm Power failure or no connection Internal battery backup low voltage alarm 11.3±0.3V No tidal volume No tidal volume within 6s High Minute Volume alarm Low Minute Volume alarm 5L/min-99L/min 1L/min-30L/min High Airway pressure alarm Low Airway pressure alarm High oxygen concentration alarm Low oxygen concentration alarm 20cmH2O-100cmH2O 0cmH2O-20cmH2O 19%-100% 18%-99% Continuous pressure alarm (PEEP+1.5cmH2O) over 16s Suffocation warning Fan error Oxygen deficit 5-60s Show on screen Show on screen The maximum limited pressure
ICU Ventilator SH300 Features 10.4" TFT color screen Easy setting by navigator wheel knob and touch key Wide choice of ventilation modes including CPAP, APRV, BIPAP Flow and pressure trigger Static compliance and resistance monitor PEEP, P-V loop, V-F loop Three-level visual and audible alarm, with concise words describing problems Advanced built-in electronic air-oxygen mixing device Durable and accurate built-in flow sensor Integrated expiration valve, easy to be sterilized Backup apnea ventilation Auto nebulizer Built-in battery CE certified
ICU ventilator, anesthesia system with ventilator, anesthesia system for veterinary, cpap ventilator for infant , nitrous oxide sedation system , bipap system.
Product Details: Tidal Volume 0-2000ml Brand Philips Model Name/Number EV300 Respiratory Rate 0-90 BPM Inspiratory/Expiratory (I:E) Ratio 9.9:1 to 1:9.9 Trilogy EV 300 Philips Trilogy Ventilator provides both invasive mechanical ventilation (IMV) and non-invasive ventilation (NIV) and a range of monitoring capabilities for patients at or above 2.5 kg. Therefore, patients can be treated with a single device throughout their hospital stay, regardless of changing conditions. Trilogy EV300 offers comprehensive, advanced NIV auto-titrating therapy modes include AVAPS-AE, and IMV is available with single- and dual-limb circuits. A complete connected solution Trilogy EV300 communicates: Transmits and translates data from the device to the hospital EPR via patient monitoring or middleware systems. Key features include: Surveillance: The ability to remotely view ventilator settings, performance, and alarms from locations such as central monitoring stations. Event review: The ability to look at changes in a patientâ??s condition and response to various therapies, alarms and other pertinent events. Health Level 7 (HL7) interface: Used to export ventilator data to the patient chart and pull in patient demographics for patient identification. Simplified workflow Trilogy EV300 ventilators feature an easy-to-use 8-inch touchscreen and intuitive menu navigation. On-screen help and alarm guidance aid user proficiency making it easy for clinicians to feel confident. Ultimate Portability Trilogy EV300 has a 15-hour battery life* with an internal and detachable battery. Additionally, the hot swappable detachable battery provides uninterrupted power. Easy to service Trilogy EV300 only requires preventative maintenance once every year, and can be serviced and repaired onsite by biomedical engineers or Philips trained field engineers, reducing the device downtime and lifetime running costs. Enhancing patient comfort Designed to make breathing more comfortable, the Digital Auto-Trak setting provides an enhanced triggering response for patients with minimal respiratory effort while lessening the need for manual adjustments.
COVID19 repurposed CPAP/SVT/PSV ventilator TUV CE/Whitelisted EXW/TT available **please inquire for updates to production status.
Standard: IEC/EN60898-1 GB/T10963.1 Instantaneous trip type: Electronic /Electromagnetic The number of poles: 1P+N/3P+N Rated limit short circuit breaking capacity (Inc): 6kA Rated working current (In): 16-63A (can be extended to 125A) Rated working voltage (Ue): AC 230/400V Rated operating frequency: 50/60Hz Rated impulse withstand voltage (Uimp): 4kV Rated residual operating current : 10/30/100/300mA Mechanical/electrical life: 4000/4000 Times Type of residual current : A/AC
Standard: IEC/EN61008-1 GB/T16916.1 Release Type of Leakage Protection: Electronic /Electromagnetic The number of poles: 1P+N/3P+N Rated limit short circuit breaking capacity (Inc): 6kA Rated working current (In): 16-63A Rated working voltage (Ue): AC 230/400V Rated operating frequency: 50/60Hz Rated impulse withstand voltage (Uimp): 4kV Rated residual operating current : 10/30/100/300mA Mechanical/electrical life: 4000/4000 Times Type of residual current: A/AC
Standard: IEC/EN61008-1 GB/T16916.1 Release Type of Leakage Protection: Electronic /Electromagnetic The number of poles: 1P+N/3P+N Rated limit short circuit breaking capacity (Inc): 6kA Rated working current (In): 16-63A Rated working voltage (Ue): AC 230/400V Rated operating frequency: 50/60Hz Rated impulse withstand voltage (Uimp): 4kV Rated residual operating current : 10/30/100/300mA Mechanical/electrical life: 4000/4000 Times Type of residual current: A/AC
Standard: IEC/EN61008-1 GB/T16916.1 Release Type of Leakage Protection: Electronic /Electromagnetic The number of poles: 1P+N/3P+N Rated limit short circuit breaking capacity (Inc): 6kA Rated working current In: 16-63A (can be extended to 125A) Rated working voltage (Ue): AC 230/400V Rated operating frequency: 50/60Hz Rated impulse withstand voltage (Uimp): 4kV Rated residual operating current : 10/30/100/300mA Mechanical/electrical life: 4000/4000 Times Type of residual current: A/AC
Standard: IEC/EN61008-1 GB/T16916.1 Release Type of Leakage Protection: Electronic /Electromagnetic The number of poles: 1P+N/3P+N Rated limit short circuit breaking capacity (Inc): 6kA Rated working current (In): 16-63A Rated working voltage (Ue): AC 230/400V Rated operating frequency: 50/60Hz Rated impulse withstand voltage (Uimp): 4kV Rated residual operating current : 10/30/100/300mA Mechanical/electrical life: 4000/4000 Times Type of residual current: A/AC
Standard: IEC/EN60898-1 GB/T10963.1 Instantaneous trip type: C/D The number of poles: 1P+N Rated short circuit breaking capacity: Icn 4.5kA Rated working current: In 6-40A Rated working voltage Ue : AC 230V Rated operating frequency : 50/60Hz Rated insulation voltage Ui: 500V Rated impulse withstand voltage Uimp: 4kV Mechanical/electrical life: 10000/4000 Times
Standard: IEC/EN61009-1 GB/T16917.1 Instantaneous trip type: B/C/D The number of poles: 1P+N Rated short circuit breaking capacity (Icn): 6kA Leakage protection trip type: Electronic /Electromagnetic Rated working current (In): 6-40A Rated working voltage (Ue): AC 230 Rated operating frequency: 50/60Hz Rated insulation voltage (Ui): 500V Rated residual operating current : 10/30/100/300mA Life : 4000 Times Type of residual current: A/AC
Standard: IEC/EN60898-1 GB/T10963.1 Instantaneous trip type: B/C/D The number of poles: 1P/1P+N/2P/3P/3P+N/4P Rated short circuit breaking capacity (Icn): 10kA Rated working current (In): 1-63A Rated working voltage( Ue): AC 230/400V Rated operating frequency: 50/60Hz Rated insulation voltage (Ui): 500V Rated impulse withstand voltage (Uimp): 4kV Mechanical/electrical life: 10000/4000 Time