EAP 110 Engine Model : 1104C-44TAG2 Stand By kVA: 110 Stand By kW : 88 Prime kVA: 100 Prime kW : 80 Rated Current : 144 Engine heavy duty diesel engine - 12V starter and charge alternator - Replaceable air, fuel and oil filters - Mechanical governor control - Tropical type radiator - Flexible fuel hose - Oil drain valve and extension hose - Industrial type silencer and steel compensator - Maintenance-free starter battery - Water jacket heater - 1500 rpm engine speed - IP 21-23 Protection Standard - H Insulation Class - 50 Hz Frequency - 4 pole brushless synchronous type alternator - Automatic Voltage Regulator (AVR) - 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis - Convenient design for easy lifting and carrying - High standard sound proof canopy design - Modular design with easily removable nuts - bolts - Lockable doors - Transparent window for watching Control Panel - Electrostatic powder painted, providing protection against harsh weather conditions - Emergency STOP button - Fuel tank inside the chassis - Anti-vibration wedges (engine - chassis and chassis ground) Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system Engine Engine Model 1104C-44TAG2 Number of Cylinders 4 Inline Injection System Direct Compression Ratio 18,2 : 1 Bore 105 Strok 127 Displacement Lt 4,4 Air Intake Turbocharged - Air to Air Cooled Speed (RPM) 1500 Oil Capacity Lt 8 Standby Power kw / Hp 80.7 / 109 Prime Power Hp 73.4 / 99 Fuel Type Euro Diesel Governor System Mechanical Cooling System Water Cooling Coolant Capacity Lt 13 Fuel Consumption (lt / h) Lt Full Load 22 Lt %75 LOAD 16,9 Lt %50 LOAD 11,1 Frequency Hz Power kVA 110 Voltage V 230 / 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation 1% Insulation Class H Protection Standard IP22-IP23 Power Factor 0,8 Weight (Silent) Kg 1480 Weight (Open) Kg 1290 Width (Silent) Mm 1000 Length (Silent) Mm 2800 Height (Silent) Mm 1500 Fuel Tank Capacity Lt 210 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isn t permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAP 70 Engine: PERK S Engine Model : 1104A-44TG1 Stand By kVA: 70 Stand By kW : 56 Prime kVA: 64 Prime kW : 51 Rated Current : 92 Engine heavy duty diesel engine 12V starter and charge alternator Replaceable air, fuel and oil filters Mechanical governor control Tropical type radiator Flexible fuel hose Oil drain valve and extension hose Industrial type silencer and steel compensator Maintenance-free starter battery Water jacket heater 1500 rpm engine speed Alternat IP 21-23 Protection Standard H Insulation Class 50 Hz Frequency 4 pole brushless synchronous type alternator Automatic Voltage Regulator (AVR) 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis Convenient design for easy lifting and carrying High standard sound proof canopy design Modular design with easily removable nuts - bolts Lockable doors Transparent window for watching Control Panel Electrostatic powder painted, providing protection against harsh weather conditions Emergency STOP button Fuel tank inside the chassis Anti-vibration wedges (engine - chassis and chassis ground) Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system Engine Engine Model 1104A-44TG1 Number of Cylinders 4 Inline Injection System Direct Compression Ratio 17.25 : 1 Bore 105 Strok 127 Displacement Lt 4,4 Air Intake Turbocharged - Air to Air Cooled Speed (RPM) 1500 Oil Capacity Lt 8 Standby Power kw / Hp 65,6 / 88,5 Prime Power Hp 59,6 / 80,5 Fuel Type Euro Diesel Governor System Mechanical Cooling System Water Cooling Coolant Capacity Lt 13 Fuel Consumption (lt / h) Lt Full Load 14,6 Lt %75 LOAD 11 Lt %50 LOAD 8 Frequency Hz Power kVA 79 Voltage V 230 / 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation 1% Insulation Class H Protection Standard IP22-IP23 Power Factor 0,8 Weight (Silent) Kg 1280 Weight (Open) Kg 1100 Width (Silent) Mm 1000 Length (Silent) Mm 2400 Height (Silent) Mm 1500 Fuel Tank Capacity Lt 180 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isn t permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
New Diesel And Gas Generators now available
Aluminium die cast body generator, 100% heavy duty, law maintanance, single phase 5 to 10 KVA, three phage 5 to 10 KVA, brushless with AVR with slipring, types single and double bearing, AC alternator. Wooden box.
Specification:. Details of product Description. Generator Set/soundproof generator/silent generator/power genset/DC set detailed product description: 1) Rated output: 8 - 1800kW / 10kVA - 2200kVA 2) Rated voltage: 400 / 230V, 380 / 220, 220 / 120CiC 3) Rated frequency: 50 / 60Hz 4) Power factor: 0.8. Engine: Cummins engine/ Perkins engine / Deutz engine/ Isuzu engine/ China engine 1)Cooling method: closed water cooling or air force cooled 3)Rated speed: 1,500 / 1,800rpm 4) Noise level: 65dB to 75dB 7 meter away Alternator: 1) Brand: Stamford or Leroysomer or Our JUSTPOWER series 2) Rated output: 7.2 -1800kW / 9kVA -2200kVA 3) Rated voltage: 400 / 230V according to your requested 4) Rated Frequency: 50 / 60Hz 5) Power factor: 0.8 6) Phase: 3-phase, 4-wire 7) Connection: Y or other type connection 8) Rated speed: 1,500rpm / 1,800rpm 9) Excitation: harmonic excitation or phase compound or brushless 11) Voltage regulation: automatic 12) 1.0% voltage regulation (max.) in static conditions 13) Protection class: IP 22 or IP23 14)Connect with engine:Direct coupled with flywheel Control panel: 1) The generator control panel is manufactured locally by 2) The panel is provided with: a) Standard engine instrumentation b) Voltmeter with selector switch c) Ammeter with selector switch d) Frequency meter e) Current transformers f) Instrument fuses duly wired and ferruled g) Mcb of suitable rating with overload and short circuit protection h) With AMF control panel or with ATS (automatic transfer system) i) With EPA certification Packing: Wooden case or plywood case Any question,pls contact with me directly. Remark:Control panel(including Automatic protection):low and high frequency,low oil pressure protection and high water temperature protection  We will try my best to supply the product according to your specific requirement. Pls note it, you will get more than you pay.  Synchronization panel is available at our factory.  Warranty:Guarantee for one year or 1200hours from ex-factor date.During the repair time,JUSTPOWER COMPANY will provide the free easy-damageable spare arts of diesel engine caused by our quality of production or raw material.After expiration,JUSTPOWER COMPANY will supply cost spare part for you to repair it. Manufacturing standard: ISO9001,EPA,CE and
Rated power: 12kva-60kva Engine: chinese brand Alternator: chinese brand Diesel engine: four stroke, water cooling, dierect spraying, 1500/1800rpm, the closed-end circular cooling with fan. The ac generator:: phases:3 phases and 4 wires The rated voltage::400/230v(adjustable) The rated frequency:50hz/60hz(adjustable) The rated factor:0.8(lagging) Excitation:brushless insulation class:h Protection:ip22 voltage adjustment: avr Standard export package
Our company name: Qinhuangdao beifang marine parts & machinery import&export Co.,ltd we are a manufacturer of marine parts in China . Main business is supply diesel generator set and technical support Now, we have three type diesel generating set in stock , they are : STX-MAN 18V 32/40 12sets MAN 6L 27/38 4 sets MAN 9L 21/31 5 sets They can be used for shipbuilding (sand suction )and land power station. All of them are new machines. in good condition , system is complete Datas of STX-MAN18V32/40 as following: 1) diesel type ï¼?STX-MAN 18V32/40 2) specificationï¼?9080Kw x 720 RPM x 13.8 kvx 60 Hz 3) qtyï¼?12 sets 4) fuel oil ï¼?HFO or MDO 5) manufacturer : STX Engine Co., Ltd. â?? MAN impower factory/korea 6) date of manufacturer ï¼?2011year 7) test run date ï¼?March-Sep, 2011year 8) three generator sets ï¼?HYUNDAIHAR7189-1028 9) Type of supercharger : NR34/S 10) cylinder diameter x length ï¼?320MM x 400MM 11)revolution R.P.M. 720rpm 12)Average effective piston pressure 25.90Bar 13)Diesel engine output 9,080kW 14) Generator output 11,032kVA 60Hz AC 13.8 KV
EAP 88 Engine: PERKINS Engine Model : 1104A-44TG2 Stand By kVA: 88 Stand By kW : 70,4 Prime kVA: 80 Prime kW : 64 Rated Current : 115,2 Engine - PERK�°NS heavy duty diesel engine - 12V starter and charge alternator - Replaceable air, fuel and oil filters - Mechanical governor control - Tropical type radiator - Flexible fuel hose - Oil drain valve and extension hose - Industrial type silencer and steel compensator - Maintenance-free starter battery - Water jacket heater - 1500 rpm engine speed Alternat�¶r - IP 21-23 Protection Standard - H Insulation Class - 50 Hz Frequency - 4 pole brushless synchronous type alternator - Automatic Voltage Regulator (AVR) - 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis - Convenient design for easy lifting and carrying - High standard sound proof canopy design - Modular design with easily removable nuts - bolts - Lockable doors - Transparent window for watching Control Panel - Electrostatic powder painted, providing protection against harsh weather conditions - Emergency STOP button - Fuel tank inside the chassis - Anti-vibration wedges (engine - chassis and chassis â?? ground) Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system Engine PERK�°NS Engine Model 1104A-44TG2 Number of Cylinders 4 Inline Injection System Direct Compression Ratio 17.25 : 1 Bore 105 Strok 127 Displacement Lt 4,4 Air Intake Turbocharged - Air to Air Cooled Speed (RPM) 1500 Oil Capacity Lt 8 Standby Power kw / Hp 88 / 120 Prime Power Hp 80 / 110 Fuel Type Euro Diesel Governor System Mechanical Cooling System Water Cooling Coolant Capacity Lt 13 Fuel Consumption (lt / h) Lt Full Load 18,5 Lt %75 LOAD 14,2 Lt %50 LOAD 9,8 Frequency Hz Power kVA 93 Voltage V 230 / 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation �±1% Insulation Class H Protection Standard IP22-IP23 Power Factor 0,8 Weight (Silent) Kg 1350 Weight (Open) Kg 1160 Width (Silent) Mm 1000 Length (Silent) Mm 2800 Height (Silent) Mm 1500 Fuel Tank Capacity Lt 210 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnâ??t permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAP 70 Engine: PERKINS Engine Model : 1104A-44TG1 Stand By kVA: 70 Stand By kW : 56 Prime kVA: 64 Prime kW : 51 Rated Current : 92 Engine - PERKINS heavy duty diesel engine - 12V starter and charge alternator - Replaceable air, fuel and oil filters - Mechanical governor control - Tropical type radiator - Flexible fuel hose - Oil drain valve and extension hose - Industrial type silencer and steel compensator - Maintenance-free starter battery - Water jacket heater - 1500 rpm engine speed Alternat�¶r - IP 21-23 Protection Standard - H Insulation Class - 50 Hz Frequency - 4 pole brushless synchronous type alternator - Automatic Voltage Regulator (AVR) - 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis - Convenient design for easy lifting and carrying - High standard sound proof canopy design - Modular design with easily removable nuts - bolts - Lockable doors - Transparent window for watching Control Panel - Electrostatic powder painted, providing protection against harsh weather conditions - Emergency STOP button - Fuel tank inside the chassis - Anti-vibration wedges (engine - chassis and chassis â?? ground) Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system Engine PERK�°NS Engine Model 1104A-44TG1 Number of Cylinders 4 Inline Injection System Direct Compression Ratio 17.25 : 1 Bore 105 Strok 127 Displacement Lt 4,4 Air Intake Turbocharged - Air to Air Cooled Speed (RPM) 1500 Oil Capacity Lt 8 Standby Power kw / Hp 65,6 / 88,5 Prime Power Hp 59,6 / 80,5 Fuel Type Euro Diesel Governor System Mechanical Cooling System Water Cooling Coolant Capacity Lt 13 Fuel Consumption (lt / h) Lt Full Load 14,6 Lt %75 LOAD 11 Lt %50 LOAD 8 Frequency Hz Power kVA 79 Voltage V 230 / 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation �±1% Insulation Class H Protection Standard IP22-IP23 Power Factor 0,8 Weight (Silent) Kg 1280 Weight (Open) Kg 1100 Width (Silent) Mm 1000 Length (Silent) Mm 2400 Height (Silent) Mm 1500 Fuel Tank Capacity Lt 180 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnâ??t permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAP 66 Engine: PERKINS Engine Model : 1103A-33TG2 Stand By kVA: 66 Stand By kW : 52,8 Prime kVA: 60 Prime kW : 48 Rated Current : 86,4 Engine - PERKINS heavy duty diesel engine - 12V starter and charge alternator - Replaceable air, fuel and oil filters - Mechanical governor control - Tropical type radiator - Flexible fuel hose - Oil drain valve and extension hose - Industrial type silencer and steel compensator - Maintenance-free starter battery - Water jacket heater - 1500 rpm engine speed Alternat�¶r - IP 21-23 Protection Standard - H Insulation Class - 50 Hz Frequency - 4 pole brushless synchronous type alternator - Automatic Voltage Regulator (AVR) - 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis - Convenient design for easy lifting and carrying - High standard sound proof canopy design - Modular design with easily removable nuts - bolts - Lockable doors - Transparent window for watching Control Panel - Electrostatic powder painted, providing protection against harsh weather conditions - Emergency STOP button - Fuel tank inside the chassis - Anti-vibration wedges (engine - chassis and chassis â?? ground) Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system Engine PERK�°NS Engine Model 1103A-33TG2 Number of Cylinders 3 Inline Injection System Direct Compression Ratio 17.25 : 1 Bore 105 Strok 127 Displacement Lt 3,3 Air Intake Turbocharged - Air to Air Cooled Speed (RPM) 1500 Oil Capacity Lt 8 Standby Power kw / Hp 60,5 / 82 Prime Power Hp 55 / 74 Fuel Type Euro Diesel Governor System Mechanical Cooling System Water Cooling Coolant Capacity Lt 10,2 Fuel Consumption (lt / h) Lt Full Load 14 Lt %75 LOAD 10,4 Lt %50 LOAD 7,2 Frequency Hz Power kVA 66 Voltage V 230 / 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation �±1% Insulation Class H Protection Standard IP22-IP23 Power Factor 0,8 Weight (Silent) Kg 1200 Weight (Open) Kg 1030 Width (Silent) Mm 1000 Length (Silent) Mm 2400 Height (Silent) Mm 1500 Fuel Tank Capacity Lt 180 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnâ??t permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAP 22 Engine: PERKINS Engine Model : 404A-22G1 Stand By kVA: 22 Stand By kW : 17,6 Prime kVA: 20 Prime kW : 16 Rated Current : 28,8 Engine - PERK�°NS heavy duty diesel engine - 12V starter and charge alternator - Replaceable air, fuel and oil filters - Mechanical governor control - Tropical type radiator - Flexible fuel hose - Oil drain valve and extension hose - Industrial type silencer and steel compensator - Maintenance-free starter battery - Water jacket heater - 1500 rpm engine speed Alternat�¶r - IP 21-23 Protection Standard - H Insulation Class - 50 Hz Frequency - 4 pole brushless synchronous type alternator - Automatic Voltage Regulator (AVR) - 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis - Convenient design for easy lifting and carrying - High standard sound proof canopy design - Modular design with easily removable nuts - bolts - Lockable doors - Transparent window for watching Control Panel - Electrostatic powder painted, providing protection against harsh weather conditions - Emergency STOP button - Fuel tank inside the chassis - Anti-vibration wedges (engine - chassis and chassis ground) Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system Engine PERKINS Engine Model 404A-22G1 Number of Cylinders 4 Inline Injection System Direct Compression Ratio 23.3:1 Bore 84 Strok 100 Displacement Lt 2,21 Air Intake Naturally Aspirated Speed (RPM) 1500 Oil Capacity Lt 10,6 Standby Power kw / Hp 20,6 / 27,8 Prime Power Hp 18,7 / 25,2 Fuel Type Euro Diesel Governor System Mechanical Cooling System Water Cooling Coolant Capacity Lt 14 Fuel Consumption (lt / h) Lt Full Load 5,3 Lt %75 LOAD 4 Lt %50 LOAD 2,9 Frequency Hz Power kVA 22 Voltage V 230 / 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation ±1% Insulation Class H Protection Standard IP22-IP23 Power Factor 0,8 Weight (Silent) Kg 720 Weight (Open) Kg 590 Width (Silent) Mm 950 Length (Silent) Mm 2000 Height (Silent) Mm 1200 Fuel Tank Capacity Lt 125 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnâ??t permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAC 1000 Engine: CUMMINS Engine Model : KTA38-G2A Stand By kVA: 1000 Stand By kW : 800 Prime kVA: 909 Prime kW : 727 Rated Current : 1308 Engine - CUMMINS heavy duty diesel engine - 12V starter and charge alternator - Replaceable air, fuel and oil filters - Mechanical governor control - Tropical type radiator - Flexible fuel hose - Oil drain valve and extension hose - Industrial type silencer and steel compensator - Maintenance-free starter battery - Water jacket heater - 1500 rpm engine speed Alternat�¶r - IP 21-23 Protection Standard - H Insulation Class - 50 Hz Frequency - 4 pole brushless synchronous type alternator - Automatic Voltage Regulator (AVR) - 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis - Convenient design for easy lifting and carrying - High standard sound proof canopy design - Modular design with easily removable nuts - bolts - Lockable doors - Transparent window for watching Control Panel - Electrostatic powder painted, providing protection against harsh weather conditions - Emergency STOP button - Fuel tank inside the chassis - Anti-vibration wedges (engine - chassis and chassis â?? ground) Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system Engine CUMM�°NS Engine Model KTA38-G2A Number of Cylinders 12 - V TYPE Injection System Direct Compression Ratio 14.5:1 Bore 159 Strok 159 Displacement Lt 38 Air Intake Turbocharged, Aftercooled Speed (RPM) 1500 Oil Capacity Lt 135 Standby Power kw / Hp 895 / 1199 Prime Power Hp 813 / 1089 Fuel Type Euro Diesel Governor System Electronic Cooling System Water Cooling Coolant Capacity Lt 350 Fuel Consumption (lt / h) Lt Full Load 202,3 Lt %75 LOAD 153,7 Lt %50 LOAD 103,1 Frequency Hz Power kVA 825 Voltage V 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation �±1% Insulation Class H Protection Standard IP22-IP23 Power Factor 0,8 Weight (Silent) Kg 9350 Weight (Open) Kg 8200 Width (Silent) Mm 2200 Length (Silent) Mm 6200 Height (Silent) Mm 2800 Fuel Tank Capacity Lt 1750 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnâ??t permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAC 890 Engine: CUMMINS Engine Model : KTA38-G2B Stand By kVA: 890 Stand By kW : 712 Prime kVA: 809 Prime kW : 647 Rated Current : 1165 Engine - CUMMINS heavy duty diesel engine - 12V starter and charge alternator - Replaceable air, fuel and oil filters - Mechanical governor control - Tropical type radiator - Flexible fuel hose - Oil drain valve and extension hose - Industrial type silencer and steel compensator - Maintenance-free starter battery - Water jacket heater - 1500 rpm engine speed Alternator - IP 21-23 Protection Standard - H Insulation Class - 50 Hz Frequency - 4 pole brushless synchronous type alternator - Automatic Voltage Regulator (AVR) - 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis - Convenient design for easy lifting and carrying - High standard sound proof canopy design - Modular design with easily removable nuts - bolts - Lockable doors - Transparent window for watching Control Panel - Electrostatic powder painted, providing protection against harsh weather conditions - Emergency STOP button - Fuel tank inside the chassis - Anti-vibration wedges (engine - chassis Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system Engine CUMM�°NS Engine Model KTA38-G2B Number of Cylinders 12 - V TYPE Injection System Direct Compression Ratio 14.5:1 Bore 159 Strok 159 Displacement Lt 38 Air Intake Turbocharged, Aftercooled Speed (RPM) 1500 Oil Capacity Lt 135 Standby Power kw / Hp 789 / 1057 Prime Power Hp 711 / 953 Fuel Type Euro Diesel Governor System Electronic Cooling System Water Cooling Coolant Capacity Lt 350 Fuel Consumption (lt / h) Lt Full Load 176,9 Lt %75 LOAD 133,3 Lt %50 LOAD 91,3 Frequency Hz Power kVA 825 Voltage V 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation ±1% Insulation Class H Protection Standard IP22-IP23 Power Factor 0,8 Weight (Silent) Kg 9300 Weight (Open) Kg 8150 Width (Silent) Mm 2200 Length (Silent) Mm 6200 Height (Silent) Mm 2800 Fuel Tank Capacity Lt 1750 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnâ??t permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAC 825 Engine: CUMM�°NS Engine Model : KTA38-G2 Stand By kVA: 825 Stand By kW : 660 Prime kVA: 750 Prime kW : 600 Rated Current : 1080 Engine - CUMMINS heavy duty diesel engine - 12V starter and charge alternator - Replaceable air, fuel and oil filters - Mechanical governor control - Tropical type radiator - Flexible fuel hose - Oil drain valve and extension hose - Industrial type silencer and steel compensator - Maintenance-free starter battery - Water jacket heater - 1500 rpm engine speed Alternat�¶r - IP 21-23 Protection Standard - H Insulation Class - 50 Hz Frequency - 4 pole brushless synchronous type alternator - Automatic Voltage Regulator (AVR) - 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis - Convenient design for easy lifting and carrying - High standard sound proof canopy design - Modular design with easily removable nuts - bolts - Lockable doors - Transparent window for watching Control Panel - Electrostatic powder painted, providing protection against harsh weather conditions - Emergency STOP button - Fuel tank inside the chassis - Anti-vibration wedges (engine - chassis and chassis â?? ground) Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system Engine CUMM�°NS Engine Model KTA38-G2 Number of Cylinders 12 - V TYPE Injection System Direct Compression Ratio 14.5:1 Bore 159 Strok 159 Displacement Lt 38 Air Intake Turbocharged, Aftercooled Speed (RPM) 1500 Oil Capacity Lt 135 Standby Power kw / Hp 731 / 980 Prime Power Hp 664 / 890 Fuel Type Euro Diesel Governor System Electronic Cooling System Water Cooling Coolant Capacity Lt 350 Fuel Consumption (lt / h) Lt Full Load 167 Lt %75 LOAD 128 Lt %50 LOAD 90 Frequency Hz Power kVA 825 Voltage V 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation ±1% Insulation Class H Protection Standard IP22-IP23 Power Factor 0,8 Weight (Silent) Kg 9250 Weight (Open) Kg 8100 Width (Silent) Mm 2200 Length (Silent) Mm 6200 Height (Silent) Mm 2800 Fuel Tank Capacity Lt 1750 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnot permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAC 790 Engine: CUMMINS Engine Model : KTA38-G1 Stand By kVA: 790 Stand By kW : 632 Prime kVA: 718 Prime kW : 574 Rated Current : 1033 Engine - CUMM�°NS heavy duty diesel engine - 12V starter and charge alternator - Replaceable air, fuel and oil filters - Mechanical governor control - Tropical type radiator - Flexible fuel hose - Oil drain valve and extension hose - Industrial type silencer and steel compensator - Maintenance-free starter battery - Water jacket heater - 1500 rpm engine speed Alternat�¶r - IP 21-23 Protection Standard - H Insulation Class - 50 Hz Frequency - 4 pole brushless synchronous type alternator - Automatic Voltage Regulator (AVR) - 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis - Convenient design for easy lifting and carrying - High standard sound proof canopy design - Modular design with easily removable nuts - bolts - Lockable doors - Transparent window for watching Control Panel - Electrostatic powder painted, providing protection against harsh weather conditions - Emergency STOP button - Fuel tank inside the chassis - Anti-vibration wedges (engine - chassis and chassis â?? ground) Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system Engine CUMM�°NS Engine Model KTA38-G1 Number of Cylinders 12 - V TYPE Injection System Direct Compression Ratio 14.5:1 Bore 159 Strok 159 Displacement Lt 19 Air Intake Turbocharged, Aftercooled Speed (RPM) 1500 Oil Capacity Lt 135 Standby Power kw / Hp 701 / 953 Prime Power Hp 634 / 862 Fuel Type Euro Diesel Governor System Electronic Cooling System Water Cooling Coolant Capacity Lt 350 Fuel Consumption (lt / h) Lt Full Load 158 Lt %75 LOAD 122 Lt %50 LOAD 86 Frequency Hz Power kVA 550 Voltage V 230 / 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation �±1% Insulation Class H Protection Standard IP22-IP23 Power Factor 0,8 Weight (Silent) Kg 9200 Weight (Open) Kg 8050 Width (Silent) Mm 2200 Length (Silent) Mm 6200 Height (Silent) Mm 2800 Fuel Tank Capacity Lt 1750 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnâ??t permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAC 495 Engine: CUMMINS Engine Model : QSZ13-G3 Stand By kVA: 495 Stand By kW : 396 Prime kVA: 450 Prime kW : 360 Rated Current : 648 Engine - CUMMINS heavy duty diesel engine - 12V starter and charge alternator - Replaceable air, fuel and oil filters - Mechanical governor control - Tropical type radiator - Flexible fuel hose - Oil drain valve and extension hose - Industrial type silencer and steel compensator - Maintenance-free starter battery - Water jacket heater - 1500 rpm engine speed Alternator - IP 21-23 Protection Standard - H Insulation Class - 50 Hz Frequency - 4 pole brushless synchronous type alternator - Automatic Voltage Regulator (AVR) - 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis - Convenient design for easy lifting and carrying - High standard sound proof canopy design - Modular design with easily removable nuts - bolts - Lockable doors - Transparent window for watching Control Panel - Electrostatic powder painted, providing protection against harsh weather conditions - Emergency STOP button - Fuel tank inside the chassis - Anti-vibration wedges (engine - chassis and chassis â?? ground) Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system Engine CUMMINS Engine Model QSZ13-G3 Number of Cylinders 6 Inline Injection System Direct Compression Ratio 17:01 Bore 130 Strok 163 Displacement L 13 Air Intake Turbocharged,Air-Air Cooled Speed (RPM) 1500 Oil Capacity L 40 Standby Power kw / Hp 470 /629 Prime Power kw / Hp 450 /603 Fuel Type Euro Diesel Governor System Electronic Cooling System Water Cooling Coolant Capacity L 60 Fuel Consumption (lt / h) L Full Load 101 L %75 LOAD 74,2 L %50 LOAD 49 Frequency Hz Power kVA 385 Voltage V 230 / 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation ±1% Insulation Class H Protection Standard IP22-IP23 Power Factor 0,8 Weight (Silent) Kg 4100 Weight (Open) Kg 3625 Width (Silent) Mm 1600 Length (Silent) Mm 4500 Height (Silent) Mm 2400 Fuel Tank Capacity L 650 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnâ??t permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAC 440 Engine: CUMMINS Engine Model : NTAA855-G7A Stand By kVA: 440 Stand By kW : 352 Prime kVA: 400 Prime kW : 320 Rated Current : 576 Engine - CUMM�°NS heavy duty diesel engine - 12V starter and charge alternator - Replaceable air, fuel and oil filters - Mechanical governor control - Tropical type radiator - Flexible fuel hose - Oil drain valve and extension hose - Industrial type silencer and steel compensator - Maintenance-free starter battery - Water jacket heater - 1500 rpm engine speed Alternat�¶r - IP 21-23 Protection Standard - H Insulation Class - 50 Hz Frequency - 4 pole brushless synchronous type alternator - Automatic Voltage Regulator (AVR) - 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis - Convenient design for easy lifting and carrying - High standard sound proof canopy design - Modular design with easily removable nuts - bolts - Lockable doors - Transparent window for watching Control Panel - Electrostatic powder painted, providing protection against harsh weather conditions - Emergency STOP button - Fuel tank inside the chassis - Anti-vibration wedges (engine - chassis and chassis â?? ground) Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system Engine CUMM�°NS Engine Model NTAA855-G7A Number of Cylinders 6 Inline Injection System Direct Compression Ratio 14.0:1 Bore 140 Strok 152 Displacement L 14 Air Intake Turbocharged,Air-Air Cooled Speed (RPM) 1500 Oil Capacity L 38,6 Standby Power kw / Hp 407 / 545 Prime Power kw / Hp 370/ 500 Fuel Type Euro Diesel Governor System Electronic Cooling System Water Cooling Coolant Capacity L 60 Fuel Consumption (lt / h) L Full Load 89,2 L %75 LOAD 67,8 L %50 LOAD 47,5 Frequency Hz Power kVA 385 Voltage V 230 / 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation �±1% Insulation Class H Protection Standard IP22-IP23 Power Factor 0,8 Weight (Silent) Kg 3765 Weight (Open) Kg 3290 Width (Silent) Mm 1600 Length (Silent) Mm 4500 Height (Silent) Mm 2400 Fuel Tank Capacity L 650 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnâ??t permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAC 420 Engine: CUMMINS Engine Model : NTAA855-G7 Stand By kVA: 420 Stand By kW : 336 Prime kVA: 382 Prime kW : 306 Rated Current : 550 Engine - CUMMINS heavy duty diesel engine - 12V starter and charge alternator - Replaceable air, fuel and oil filters - Mechanical governor control - Tropical type radiator - Flexible fuel hose - Oil drain valve and extension hose - Industrial type silencer and steel compensator - Maintenance-free starter battery - Water jacket heater - 1500 rpm engine speed Alternat�¶r - IP 21-23 Protection Standard - H Insulation Class - 50 Hz Frequency - 4 pole brushless synchronous type alternator - Automatic Voltage Regulator (AVR) - 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis - Convenient design for easy lifting and carrying - High standard sound proof canopy design - Modular design with easily removable nuts - bolts - Lockable doors - Transparent window for watching Control Panel - Electrostatic powder painted, providing protection against harsh weather conditions - Emergency STOP button - Fuel tank inside the chassis - Anti-vibration wedges (engine - chassis and chassis â?? ground) Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system Engine CUMMINS Engine Model NTAA855-G7 Number of Cylinders 6 Inline Injection System Direct Compression Ratio 14.0:1 Bore 140 Strok 152 Displacement L 14 Air Intake Turbocharged,Air-Air Cooled Speed (RPM) 1500 Oil Capacity L 39 Standby Power kw / Hp 377 / 505 Prime Power kw / Hp 343 / 460 Fuel Type Euro Diesel Governor System Electronic Cooling System Water Cooling Coolant Capacity L 55 Fuel Consumption (lt / h) L Full Load 89,2 L %75 LOAD 67,8 L %50 LOAD 47,5 Frequency Hz Power kVA 385 Voltage V 230 / 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation ±1% Insulation Class H Protection Standard IP22-IP23 Power Factor 0,8 Weight (Silent) Kg 3765 Weight (Open) Kg 3275 Width (Silent) Mm 1600 Length (Silent) Mm 4500 Height (Silent) Mm 2400 Fuel Tank Capacity L 650 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnâ??t permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAC 385 Engine: CUMMINS Engine Model : NTA855-G2A Stand By kVA: 385 Stand By kW : 308 Prime kVA: 350 Prime kW : 280 Rated Current : 505 Engine - CUMMINS heavy duty diesel engine - 12V starter and charge alternator - Replaceable air, fuel and oil filters - Mechanical governor control - Tropical type radiator - Flexible fuel hose - Oil drain valve and extension hose - Industrial type silencer and steel compensator - Maintenance-free starter battery - Water jacket heater - 1500 rpm engine speed Alternat�¶r - IP 21-23 Protection Standard - H Insulation Class - 50 Hz Frequency - 4 pole brushless synchronous type alternator - Automatic Voltage Regulator (AVR) - 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis - Convenient design for easy lifting and carrying - High standard sound proof canopy design - Modular design with easily removable nuts - bolts - Lockable doors - Transparent window for watching Control Panel - Electrostatic powder painted, providing protection against harsh weather conditions - Emergency STOP button - Fuel tank inside the chassis - Anti-vibration wedges (engine - chassis and chassis â?? ground) Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system Engine CUMM�°NS Engine Model NTA855-G2A Number of Cylinders 6 Inline Injection System Direct Compression Ratio 14.0:1 Bore 140 Strok 152 Displacement L 14 Air Intake Turbocharged, Aftercooled Speed (RPM) 1500 Oil Capacity L 39 Standby Power kw / Hp 343 / 460 Prime Power kw / Hp 312 / 418 Fuel Type Euro Diesel Governor System Mechanical Cooling System Water Cooling Coolant Capacity L 55 Fuel Consumption (lt / h) L Full Load 71,9 L %75 LOAD 54,9 L %50 LOAD 38,9 Frequency Hz Power kVA 385 Voltage V 230 / 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation �±1% Insulation Class H Protection Standard IP22-IP23 Power Factor 0,8 Weight (Silent) Kg 3585 Weight (Open) Kg 3095 Width (Silent) Mm 1600 Length (Silent) Mm 4500 Height (Silent) Mm 2400 Fuel Tank Capacity L 650 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnâ??t permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAC 350 Engine: CUMMINS Engine Model : MTAA11-G3 Stand By kVA: 350 Stand By kW : 280 Prime kVA: 318 Prime kW : 255 Rated Current : 458 Engine - CUMMINS heavy duty diesel engine - 12V starter and charge alternator - Replaceable air, fuel and oil filters - Mechanical governor control - Tropical type radiator - Flexible fuel hose - Oil drain valve and extension hose - Industrial type silencer and steel compensator - Maintenance-free starter battery - Water jacket heater - 1500 rpm engine speed AlternatIr - IP 21-23 Protection Standard - H Insulation Class - 50 Hz Frequency - 4 pole brushless synchronous type alternator - Automatic Voltage Regulator (AVR) - 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis - Convenient design for easy lifting and carrying - High standard sound proof canopy design - Modular design with easily removable nuts - bolts - Lockable doors - Transparent window for watching Control Panel - Electrostatic powder painted, providing protection against harsh weather conditions - Emergency STOP button - Fuel tank inside the chassis - Anti-vibration wedges (engine - chassis and chassis â?? ground) Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system Engine CUMMINS Engine Model MTAA11-G3 Number of Cylinders 6 Inline Injection System Direct Compression Ratio 15.0:1 Bore 125 Strok 147 Displacement L 10,8 Air Intake Turbocharged After Cooled Speed (RPM) 1500 Oil Capacity L 37 Standby Power kw / Hp 310 /415 Prime Power kw / Hp 282 /378 Fuel Type Euro Diesel Governor System Electronic Cooling System Water Cooling Coolant Capacity L 50 Fuel Consumption (lt / h) L Full Load 61,2 L %75 LOAD 44,9 L %50 LOAD 27,6 Frequency Hz Power kVA 350 Voltage V 230 / 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation �±1% Insulation Class H Protection Standard IP22 - IP23 Power Factor 0,8 Weight (Silent) Kg 3190 Weight (Open) Kg 2760 Width (Silent) Mm 1300 Length (Silent) Mm 3900 Height (Silent) Mm 1980 Fuel Tank Capacity L 450 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnot permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.