Salient Features Highly efficient 3-phase water filled motor - Easily rewindable - Dynamically balanced design - Extended life with flawless performance - Thrust bearing : Carbon + S.S. material for High thrust load capacity - 100% EC grade copper winding - Presenting world 1st design (design registered 100% fully S.S.-304 investment casting pumps. - Zero maintenance - Superior performance - Sand proof operation - Highly efficient 3-phase water filled motor Product Specification Power Range : 1.0 HP to 20.0 HP Operating Speed : 0 - 2890 RPM Operating Frequency : 0 - 50 Hz Input Solar DC Power Range : 900 Wp, 20000 Wp Input Solar DC Voltage Range : 110 Vmp - 600 Vmp Head Range : 30 Mtr , 220 Mtr Discharge Range : 10000 LPD - 420000 LPD Type of Duty : S1 material of construction - motor Part Grade Body Lock : Spring Steel Stud Ring : M.S. (Zinc Coated) Stator Stamping : CRNGO - M45 Silicon Winding Wire : 100% EC Copper Shaft : SS-420 Rotor Stamping : CRNGO - M45 Silicon Copper Lamination : 100% EC Copper Upper Housing : SS-304 Lower Housing : SS-304 Connection Piece : SS-304 Oil Seal : NBR TB Set : Carbon + SS Base : SS-304 Drain Plug : Brass Couple Sleeve : Stainless Steel Water Bolt : Brass MATERIAL OF CONSTRUCTION PUMP Part Grade Suction : SS-304 Couple : Stainless Steel Couple Counter : SS-304 Rubber Seal : NBR Bush Seal Cover : SS-304 Bowl : SS-304 Impeller : SS-304 Key : SS-410 Bowl Bush : NBR Bush : LTB-4 Middle : SS-304 Cap : NBR Outlet : SS-304
Monoblock pumps - Falcon centrifugal monoblock pumpsets are powered by a totally enclosed fan cooled AC induction two pole motor. Motor stator is made of low watt loss silicon steel laminations assembled under pressure and rigidly locked in the frame. The windings are of high-grade enameled copper wire offer excellent resistance and are varnish impregnated. Construction of motor frame and usage of quality materials result in high performance and low temperature rise thereby increasing the life cycle of the motor. salient features - High operating efficiency resulting in lower power consumption - Good suction lift characteristics - Inbuilt thermal overload protector in al single phase pumpsets upto 2.0 HP - Specially designed for wide voltage operation - Dynamically balanced rotating parts including rotor and impeller ensures minimum vibration and longer life - Back pull-out design for easy servicing and repair - Double shielded ball bearings, so no need of external lubrication - All Model fitted to Mechanical seal. specification - Power Range : 0.37Kw - 1.5 Kw (0.5 HP - 2.0 HP) - Version : Single Phase, 220-240V, 50Hz AC Supply Three Phase, 380-415V, 50Hz AC Supply - Speed : 2880 RPM - Maximum Total Head : 32 Mtr. - Maximum Flow Rate : 940 LPM - Maximum Suction Lift : 7 Mtr. - Degree of Protection : IP 44 - Class of Insulation : B0 - Maximum Ambient Tem. : 40 C - Sealing : Mechanical Seal - Type of Duty : S1 (Continuous) - Method of Starting : Permanent Split Capacitor (PSC) - Direction of Rotation : Three Phase, Electrically Reversible - Nominal Pumpset Size (Suction X Delivery in inch) : 25 X 25, 32 X 25, 40 X 32, 40 X 40, 50 X 40, 50 X 50, 65 X 50, 80 X 65, 80 X 80 (All size in mm) characteristics of clear cold water - Maximum liquid temperature : 33C max - Permissible amount of sand : 25 g/m - Allowable solids : 3000 ppm (max.) - Chloride ion density : 500 ppm (max.) - Turbidity : 50 ppm silica scale (max.) - Hardness (Drinking Water) : 300 ppm (max.) - Specific gravity : 1.004 (max.) 6 - Viscosity : 1.75 x 10 m/sec (max.) - Ph Value : 6.5 to 8.5 Part Name Material Mechanical Seal : Carbon & Ceramic Motor Shaft : EN-8 Motor Body : FG-250 Bearing : SKF End Cover : FG-250 Bracket : FG-250 Flange : FG-250 Casing : FG-250 Impeller : FG-250 Cooling Fan : Plastic
Monoblock Pumps Falcon centrifugal monoblock pumpsets are powered by a totally enclosed fan cooled AC induction two pole motor. Motor stator is made of low watt loss silicon steel laminations assembled under pressure and rigidly locked in the frame. The windings are of high-grade enameled copper wire offer excellent resistance and are varnish impregnated. Construction of motor frame and usage of quality materials result in high performance and low temperature rise thereby increasing the life cycle of the motor. salient features High operating efficiency resulting in lower power consumption - Good suction lift characteristics - Specially designed for wide voltage operation. - Dynamically balanced rotating parts including rotor and impeller ensures minimum vibration and longer life. - Back pull-out design for easy servicing and repair. - Double shielded ball bearings, so no need of external lubrication. - Mechanical seal is provided as per customers requirement Specification - Power Range : 2.2 Kw - 11.2 Kw (3.0 HP - 15.0 HP) - Version : Three Phase, 380-415V, 50Hz AC Supply - Speed : 2880 RPM - Maximum Total Head : 65 Mtr. - Maximum Flow Rate : 1450 LPM - Maximum Suction Lift : 7 Mtr. - Degree of Protection : IP 44 - Class of Insulation : B0 - Maximum Ambient Tem. : 40 C - Sealing : Stuffing Box - Type of Duty : S1 (Continuous) - Direction of Rotation : Three Phase, Electrically Reversible - Nominal Pumpset Size (Suction X Delivery in inch) : 50 X 40, 50 X 50, 65 X 50, 80 X 65, 80 X 80 100 X 80 and 100 X 100 (All size in mm) Characteristics Of Clear Cold Water - Maximum liquid temperature : 33C max - Permissible amount of sand : 25 g/m - Allowable solids : 3000 ppm (max.) - Chloride ion density : 500 ppm (max.) - Turbidity : 50 ppm silica scale (max.) - Hardness (Drinking Water) : 300 ppm (max.) - Specific gravity : 1.004 (max.) 6 - Viscosity : 1.75 x 10 mÃ?/sec (max.) - Ph Value : 6.5 to 8.5 Material of construction - motor Part Name Material Gland Dori : Graphite String Motor Shaft : EN-19 with SS SLEEVE Motor Body : FG-250 Bearing : SKF End Cover : FG-250 Bracket : FG-250 Flange : FG-250 Casing : FG-250 Impeller : FG-250 Cooling Fan : Aluminium
Monoblock pumps Falcon centrifugal monoblock pumpsets are powered by a totally enclosed fan cooled AC induction two pole motor. Motor stator is made of low watt loss silicon steel laminations assembled under pressure and rigidly locked in the frame. The windings are of high-grade enameled copper wire offer excellent resistance and are varnish impregnated. Construction of motor frame and usage of quality materials result in high performance and low temperature rise thereby increasing the life cycle of the motor. Salient Features High operating efficiency resulting in lower power consumption. - Good suction lift characteristics. - Specially designed for wide voltage operation. - Dynamically balanced rotating parts including rotor and impeller ensures minimum vibration and longer life. - Back pull-out design for easy servicing and repair. - Double shielded ball bearings, so no need of external lubrication. specification - Power Range : 1.5 Kw - 5.5 Kw (2.0 HP - 7.5 HP) - Version : Three Phase, 380-415V, 50Hz AC Supply - Speed : 1440 RPM - Maximum Total Head : 12 Mtr. - Maximum Flow Rate : 3160 LPM - Maximum Suction Lift : 7 Mtr. - Degree of Protection : IP 44 - Class of Insulation : B0 - Maximum Ambient Tem. : 40 C - Sealing : Stuffing Box - Type of Duty : S1 (Continuous) - Direction of Rotation : Three Phase - Electrically Reversible - Nominal Pumpset Size (Suction X Delivery in inch) : 80 X 80, 100 X 100, 125 X 125, 150 X 150 (All size in mm) Characteristics Of Clear Cold Water - Maximum liquid temperature : 33C max - Permissible amount of sand : 25 g/m - Allowable solids : 3000 ppm (max.) - Chloride ion density : 500 ppm (max.) - Turbidity : 50 ppm silica scale (max.) - Hardness (Drinking Water) : 300 ppm (max.) - Specific gravity : 1.004 (max.) 6 - Viscosity : 1.75 x 10 m/sec (max.) - Ph Value : 6.5 to 8.5 Part Name Material Gland Dori : Graphite String Motor Shaft : EN-19 with SS SLEEVE Motor Body : FG-250 Bearing : SKF End Cover : FG-250 Bracket : FG-250 Flange : FG-250 Casing : FG-250 Impeller : FG-250 Cooling Fan : Aluminum
The fracturing pump fluid end blocks and spares are 100 interchangeable to We can supply the Spare Parts for the Pump Models as follow HQ 1400 4 fracturing pump SPM2000 5 fluid end HQ 1400 2000 Frac Pump Fluid End Asembly SPM TWS 600 Plunger Pump SPM QWS2500 Quintuplex Plunger Pump Compatible TWS 2000 2250 Frac Pump Fluid End Assembly Halliburton HT400 plunger pump Serva TPA600 pump SERVA pump TPA 400 plunger pump . TPA 600 plunger pump. TPB 600 plunger pump. TPA 400 plunger pump GD-2500 Quintuplex Plunger Pump Compatible OPI 1800AWS Frac Pump Compatible
Ship spare parts, engine, motor , pump, compressor , generator etc.Export
Rongle provides a full line of replacement parts for most popular mud pumps. Mud Pump Fluid end Parts and Expendables Rongle provides a full line of replacement parts for most popular mud pumps worldwide,Include but not limited below: ¡¤F-350/500/800/1000/1300/1600/2200, FB-1300/1600 ¡¤TEE, PAH, PZ-7, PZ-8, PZ-9, PZ-10, PZ-11,PXL ¡¤T-500/800/1000/1300/1600 ¡¤W-440, W-446, W-1612, WH-2214 ¡¤7-P-50, 8-P-80, 9-P-100, 10-P-130, 12-P-160, 14-P-220 ¡¤A-600-PT A-850-PT A-1100-PT A-1400-PT A-1700-PT International standard export packing or as client's requirement
Well Service plunger Pump packing set made from high quality materials for extended service life in all applications. We offer a variety of compounds for all types of environments including high pressure, abrasive and high temperature. We offer both complete sets and replacement sets. Replacement Set Header Ring, Pressure Ring, Top Adapter and Wiper Ring Complete Set Header Ring, Pressure Ring, Top Adapter, Brass Lantern Ring and Adapter Material Buna NBR Nitrile fabric HSN HNBR, Neoprene, Fluorocarbon Perfluoroelastomer, Filled PTFE blends, PEEK Aramid Kevlar fabric HNBR composite other elastomer and plastic materials.
Fly ash is a finely divided residue made from the combustion of pulverized coal that can be used to increase concrete durability and workability, while reducing permeability. As fly ash contains aluminous and siliceous components, it may form cement when mixed with water if the calcium content of the fly ash is high enough. Similarly, mixing fly ash with lime and water can create a substance similar to Portland cement. Fly ash can be separated into two main types, known as: Class F Class F fly ash contains particles covered in a type of melted glass allowing it to reduce the risk of concrete expansion and increase resistance to sulfates and alkali-aggregate reactions. Class C Class C fly ash contains a higher percentage of calcium oxide, making it more effective in strengthening structural concrete. Applications & Benefits of Fly Ash: Fly ash is used in commercial and industrial sectors for improving the durability and workability of concrete mixes. Fly ash is also used as filler in paints, adhesives, and metal and plastic composites. It's commonly used as structural fill for road construction and fly ash can be used to make bricks, ceramic tiles, plaster, Portland cement, and ready-mix cement.
Microsilica (silica fume) is a by-product of silicon metal or ferrosilicon industries, is an amorphous silicon dioxide SiO2. This product reacts chemically with the calcium hydroxide in the cement paste which yields a calcium silicate hydrate gel that significantly enhances strength and durability. The super fine microsilica fills the voids between cement particles creating a very dense, less permeable concrete. Physical characteristics: Color: gray or gray white powder Bulk density: 320-700 kg/m3 Chemical composition: Items SiO2 Al2O3 Fe2O3 MgO CaO Na2O Moisture Content 75-98% 1.0-0.2% 0.9-0.3% 0.7-0.1% 0.3-0.1% 1.3-0.2% Fineness: the fineness of the silica fume is less than 1 1/4m, and the average particle size is 0.1 0.3 1/4m, and the specific surface area is 20 - 28 m2/g. The fineness and specific surface area are about 80-100 times of cement and 50-70 times of fly ash. Maxtech Micro Silica supplies will be as per QCS 2014 (ASTM C1240): SiO2: >/= 92% LOI:
GGBFS Ground granulated blast furnace slag (GGBFS) The ground granulated blast furnace slag (GGBFS) is a by-product of iron manufacturing which when added to concrete improves its properties such as workability, strength and durability. This material is obtained by the heating of iron ore, limestone and coke at a temperature about 1500 degree Celsius. The process is carried out in a blast furnace. The formation of GGBFS is not direct. The by-product of iron manufacturing is a molten slag and molten iron. The molten slag consists of alumina and silica, also with the certain amount of oxides. This slag is later granulated by cooling it. For this, it is allowed to pass through a high-pressure water jet. This result in quenching of the particles which results in granules of size lesser than 5mm in diameter. The main constituents of blast furnace slag are CaO, SiO2, Al2O3 and MgO. These are the minerals that are found in most of the cementitious substances. The particles are further dried and ground in a rotating ball mill to form a fine powder, known as ground granulated blast furnace slag cement. Now different methods can be employed to perform the main process called as the quenching. Applications & Benefits of GGBFS: In concrete: The incorporation of ground granulated blast furnace slag in concrete manufacture gains many advantages which are mentioned below: GGBFS in concrete increases the strength and durability of the concrete structure. It reduces voids in concrete hence reducing permeability GGBFS gives a workable mix. It possesses good pumpable and compaction characteristics The structure made of GGBFS constituents help in increasing sulphate attack resistance. The penetration of chloride can be decreased. The heat of hydration is less compared to conventional mix hydration. The alkali-silica reaction is resisted highly. These make the concrete more chemically stable. Gives good surface finish and improves aesthetics. The color is more even and light. Lower chances of efflorescence. The maintenance and repair cost of structures are reduced thus increasing the life cycle of concrete structures. Unlike cement, GGBFS does not produce carbon dioxide, sulphur dioxide or nitrogen oxides. White Cement: White Portland Cement is of high quality, whiteness and strength, it essentially has the same properties and characteristics as gray cement, except for color. It is widely used in numerous applications such as precast concrete, cast-in-place concrete, terrazzo, median barriers, curbs, tile grout, paint, masonry units, swimming pools, glass fibre reinforced surface bonding mortars.
Microsilica (silica fume) is a by-product from silicon metal or ferrosilicon industries, is an amorphous silicon dioxide SiO2. This product reacts chemically with the calcium hydroxide in the cement paste which yields a calcium silicate hydrate gel that significantly enhances strength and durability. The super fine microsilica fills the voids between cement particles creating a very dense, less permeable concrete. White Cement advantages: Sustainability: Solar Reflectance Index (SRI): Floors finished with white or pastel color concrete will have a much higher SRI than floors with gray concrete, therefore they will reflect light better, and generate energy savings for the lifetime of the floors. Reduction of Heat Island effect: By constructing buildings with white concrete roofs or light-colored roof tiles, the Heat Island Effect is reduced from surfaces generating less heat and improved reflectivity. Architectural Concrete: White Portland Cement is ideal for decorative concrete and Architectural Concrete applications, Masonry and Cementitious Building Products. A key advantage of using white cement for these applications is that it provides a base color that can be tinted to custom colors to meet any color spectrum demand.
Pozzolan is a siliceous or siliceous and aluminous material that in itself possesses little or no cementitious value but will, in finely divided form and in the presence of moisture, chemically react with calcium hydroxide at ordinary temperatures to form compounds having cementitious properties. It is therefore classified as a cementitious material. There are both natural and artificial pozzolans. The quantification of the capacity of a pozzolan to react with calcium hydroxide and water is given by measuring its pozzolanic activity.
Photocells Fans & ventilation, Hazardous area lighting Industrial plugs & sockets Industrial & commercial Lamps Light fittings: fluorescent, weatherproof & floodlighting Refrigeration & air conditioning spares Water heating elements Wiring accessories MCB's Circuit breaker Vacuum Breakers Control transformers Fuses & load break devices Hazardous area products Industrial beacons Industrial sounders, buzzers Industrial surge protection Safety switches Clamp meters Multi-meters Testers Semiconductors: thyristors, rectifiers Pressure switches Solenoid & pilot valves Photoelectric Sensors