(1) Combining with domestic actual production demand, this machine is equipped with completely automatic machinery equipment integrating automatic tube filling, coagulant dosing and atomizing, drying, capping, vacuum capping, tube taking and tray packing; (2) This machine comprehensively adopts programmable control and pneumatic actuator. According to the product feature of vacuum blood collection tube, control all actuation actions of machinery in organic combination form via program and software; (3) This machine is equipped with automatic heat shrink packaging machine, so as to achieve packing automation and fully automatic modular production; (4) This machine adopts South Koreas Sejong bivalve and multi-function software control system to achieve dosing and atomizing; it also adopts two sets of 100-head plug-in hot air dryer, which can grasp the cap conveying device for 100 assembled caps, one full-automatic vacuum compensated-type vacuum capping machine and the tube taking and foam tray mechanism which can grasp 100 finished tubes simultaneously; after removing the tube, insert it into the foam packing tray mechanism, control such mechanism actions via programmable program and execute via pneumatic mechanism, in which way all procedures will be completed fully automatically, including BCA coagulant dosing, drying, capping, vacuum capping, tube taking and tray packing. This machine features high automation degree, high production efficiency, stable performance, low failure rate, easy operation, low maintenance fee, etc. (5) It is able to install oblique foam tray online according to customers demand.
Products description: vacuum plain blood collection tube non-additive blood tube 1.Material:PET/glass tube 2.Specification:13*75mm,13*100mm,16*100mm 3.Volume:Volume:2ml-10ml 4.Additive: Non-additive 5.Certificate:CE & ISO 13485 certificate approved 6.Packing:Customized production as requested. Normal carton size as follows: 100pcs/foam tray,1200pcs/carton 13x75mm: 515*360*183mm/1200pcs 13*100mm: 515*360*233mm/1200pcs 16*100mm:580*390*233mm/1200pc 7.Certificate:CE & ISO13485 certificate approved 8.Tray material: Foam 9. Cap color:red 10.Delivery time:15-25 days depend on order size 11.Label and logo printing: as requested 12.Shelf time: PET-18 months, glass-24months 13.Storage: No direct sunlight at room temperature You are warmly welcome to visit our company and we expect highly to win-win cooperation with you! Now contact me: Felix Ma
Blood Collection Tube 1. Whole Blood Tube 1.1 ESR Tube 1.2 K2 EDTA tube 1.3 K3 EDTA tube 1.4 ACD Tube. 2 Serum Tube 2.1 Plain Tube without Additive 2.2 Tube with Clot Activator 2.3 SST Tube. 3 Plasma Tube 3.1 Glucose Tube 3.2 Coagulation Tube 3.3 Sodium Heparin Tube 3.4 Lithium Heparin Tube Available size: 13*75mm, 13*100mm, 16*100mm, 8*12mm.
161;244;tube loading161;adust absorption161;atube reverse checking--reagent dosing( spray/filling)161;adrying system161;aautomatic adding cap161;avacuum capping161;apick up tubes onto foam rack161;atest tube tray recycling system; all the above steps automatically finished online. Main technical parameter¡o 1. Suitable specification tube¡o13*75mm, 13*100mm pet tube/ glass tube; for 16*100mm tube, only by changing some accessories. 2. Caps: round, flat shape caps can be used in same line. 3. Reagent dispensing nozzles¡o2 nozzles (nordson efd) 4. Filling or spraying precision: 161; 5. Vacuum precision: 161;¨ 6. Drying stations¡o4 stations 7. Production capacity: 16000pcs/hour. 8. Air pressure¡o0.8mpa 9. Air consumption¡o20m3/h 10.Power¡oac380v 50/60hz 11.Power consumption¡o15kw Wooden box packing
Conventional
EPGT tube stands on EDTAK2 with Gel Tube. It is coated with lithium heparin and inside the tube a barrier Gel presented at the bottom. Product Feature they are normally made of glass and plastic. In addition, the plastic tube includes PET, PP and PS. Product Specification/Models 1ml 13í-75mm VP10041S 2ml VP20031S 3ml VP30031S 4ml 13í-100mm VP40042S 5ml VP50032S 6ml VP60032S 8ml 16í-100mm VP80043S 9ml VP90043S Application. Through centrifugation, the separation gel can form a barrier between plasma and blood cell and totally separate them. Clinical specimen obtained is suitable for analysis of virus capacity and molecular diagnostics of undiluted plasms. Other Information We are professional manufactory dealing especially with the export of blood collection kits. We are in a position to accept orders according to the customer's samples. 100pcs/tray 1200pcs/carton
Product feature They are normally made of glass and plastic. In addition, the plastic tube includes pet , pp and ps. Product specification/models 3ml 13íß75mm vp30011s 4ml vp40011s 5ml vp50011s 3ml 13íß100mmvp30012s 4ml vp40012s 5ml vp50012s 6ml vp60012s 8ml 16íß100mmvp80013s 9ml vp90013s Application It is used for collecting blood specimen for biochemistry and immunology tests, especially fast in blood coagulation. Other information We are professional manufactory dealing especially with the export of blood collection kits. We are in a position to accept orders according to the customer's samples. 100pcs/tray 1200pcs/carton
Ssgt tube stands on clot activator with gel tube. It is coated with clot activator and inside the tube a barrier gel presented at the bottom. Product feature They are normally made of glass and plastic. In addition, the plastic tube includes pet, pp and ps. Product specification/models 3ml 13íß75mm vp30021s 3.5ml vp35021s 3ml 13íß100mm vp30022s 4ml vp40022s 5ml vp50022s 7ml 16íß100mm vp70023s 8ml vp80023s Application It is used for clinical biochemistry and immunology. The obvious characteristic of ssgt tube is used to obtain high-quality plasma specimen for medical laboratories. Other information We are professional manufactory dealing especially with the export of blood collection kits. We are in a position to accept orders according to the customer's samples. 100pcs/tray 1200pcs/carton
Product specification/models Infant blood collection tube: 8*45mm Color: red, yellow, lavender, green, black, gray, blue. Application It's used for children's blood collection Other information We are professional manufactory dealing especially with the export of blood collection kits. We are in a position to accept orders according to the customer's samples. 100pcs/tray 1200pcs/carton
EDTA salts (ethylene diamine tetra acetic acid) are used for the anticoagulation of whole blood for haematological investigations as the cellular components of the blood are particularly well preserved by EDTA. It works as an anticoagulant as it forms complexes with metal ions such as calcium, therefore inhibiting the coagulation cascade. Anticoagulation with EDTA is irreversible. The EDTA concentration in tubes is LYBCON Vacutainer 1.8mg per ml of complete blood when the fill level is correct, as recommended by the ICSH (International Council Society of Haematology) and the CLSI (Clinical and Laboratory standards institute). The institutes recommend dipotassium EDTA salt (K EDTA) for 2 haematological investigation. K EDTA is used in 2 LYBCON Vacutainer tubes in spray dried form.
CE&ISO certified professional manufacturer of medical supplies lab consumables vacutainer since2009-Hebei Vacuum blood collection tubes are applicable to the clinical blood test and the blood cells analysis The internal walls of the tubes are coated with different additives designed to stabilize and preserve the specimen prior to analytical testing *Red: Non-additive - Serum *Red: Clot Activator-Serum *Yellow: Gel & Clot Activator -Serum *Purple: ETDA K2 / ETDA K3 - Whole blood *Black: 3.8% Sodium Citrate (1:4)- Whole blood *Blue: 3.2% Sodium Citrate (1:9)- Whole blood or Plasma *Green: Lithium Heparin / Sodium Heparin-Plasma *Grey: Glucose - Plasma
Product name:vacuum blood collection tube Type:Vacuum or non vacuum,micro blood collection tube Spec:Gel+clot activator tube,plain tube ,no additive tube, clot activator,tube,sodium heparin tube,lithium heparin tube,pt tube,3.2% sodium citrate tube,edta k3 tube,edta k2 tube,edta tube,ESR tube,3.8% sodium citrate tube,glucose tube sodium fluride tube,fluoride tube Cap Color:purple/Lavender/Red/Yellow/Blue/Green/Gray/Black Material:PET plastic or Glass Tube size :13*75mmï¼?13*100mm Volume:1ml,2ml,3ml,4ml,5ml,6ml,7ml Etc Shelf Life:2years Disinfecting Type:gamma ray Sterilized:yes Band:Chaoran Sample:Availible OEM:Available Certificate:CE/ISO
SERUM TUBES In order to obtain serum samples from plastic tubes, the tube must have coagulation activator added. As the plastic suface alone is insufficient to trigger the coagulation within an acceptable time, LYBCON VACUTAINER serum tubes have silica particles added for this purpose. CLOTTING TIMES The recommended minimum time for the coagulation of samples from patients who have not been treated with anticoagulants is 30- 45 minutes for serum (red).
Specification:50ml,60ml,100ml Unique labeling urine collection hole makes urine collecting and transferring convenient sanitary and safe. This container can prevent outer substance and bacteria contaminating urine specimen and urine spilling, which maximally avoids the risk of contacting pathogenic urine specimen by patient and medial people. The label is easy to tear and re-seal. Packing:500pcs/ctn Weight:G.W.7.8kg/ctn, N.W.6.0kg/ctn Dimension:595mm*490mm*400mm
Pro-coagulation tube with orange stopper. Clot activator is prefilled for quik serum measurement and immunology test. (glass & plastic 12/13*75,12/13*100, 15/16*100) Packing:100pcs/plate,1200pcs/ctn Weight:G.W.12.5kg/ctn,N.W.11.5kg/ctn Dimension:470mm*370mm*215mm
LYBCON Vacutainer GEL-SST Advance tubes During the centrifugation of the LYBCON Vacutainer GEL-SST Advance tubes, an inert LYBCON Vacutainer gel separates the serum and the blood clot preventing the contamination of the serum from the separated cellular components. For example, the serum for certain analytes such as potassium, phosphorus and glucose must be separated from the cells within a few hours - otherwise the results will be significantly distorted. Using LYBCON GEL-SST Advance tubes routine analyses in clinical chemistry such as potassium and glucose are still stable after a week of storage at 2-8 C. Clinical evaluations of special chemistry demonstrate a high degree of analyte stability with the acrylic gel in the LYBCON GEL-SST Advance, with detection of >90% of the therapeutic drugs and other special analytes(proteins/peptides, steroids and vitamins) tested. As a result of the type of gel used in the GEL-SST Advance tubes, LYBCON Vacutainer short centrifugation times of 5 minutes at 3000g can be achieved. The stability of the gel barrier is a distinct advantage during transport and storage. The main advantages of gel tubes versus non-gel tubes are: Stable barrier between serum and clotted blood, therefore better analyse stability. Better sample quality. Optimisation of the work flow: Short centrifugation time, sample processing and archiving in the primary tube. No possibility of misidentification due to the use of secondary tubes. CLOTTING TIMES The minimum recommended coagulation time for GEL-SST Advance tubes for patients who have not LYBCON Vacutainer received anticoagulation treatment is 30 minutes. CENTRIFUGING CONDITIONS 1600-2000g for 10 minutes MIXING RECOMMENDATION Serum Separation Tubes should be gently inverted 180 and back 6-8 times. EFFECTS OF TEMPERATURE LYBCON Vacutainer GEL-SST Advance should be stored at 4-25C and protected from direct sunlight during storage. Cooling of the tube by or during centrifuging can affect the movement capability of the gel. The optimum separation of serum and coagulated blood is achieved at a temperature of 20-25C. Serum Separation Tubes should be gently inverted 180 and back 6-8 times. CLOT ACTIVATOR LYBCON Vacutainer GEL-SST Advance tubes contain silica particles. SPECIFICATION Specimen: Serum Additive: Gel & Clot Activator Cap color: Dark yellow Tube Size: 13x75mm Draw Volume: 3.5mL Max. draw volume Tolerance: ±10%
SODIUM CITRATE Trisodium citrate is used as an anticoagulant for coagulation investigations. It works as an anticoagulant as it forms complexes with metal ions such as calcium inhibiting the coagulation cascade. Anticoagulation with trisodium citrate is reversible. LYBCON Vacutainer Citrate tubes contain buffered citrate in accordance with recommendations: 0.105 M or 0.109 M of buffered trisodium citrate solution, equivalent to 3.2% trisodium citrate The blood to additive ratio is 9:1. The citrate solution in the acts as LYBCON Vacutainer a buffer. Therefore, no additional buffer substances are added as these can adversely affect laboratory analysis. LYBCON Vacutainer Citrate tubes are also suitable for carrying out special test procedures such as the platelet function test PFA-100. Special tubes and the associated additional costs are therefore unnecessary. FILL LINE MARKING The significance of the correct ratio of blood to additive for coagulation samples is well documented. The correct fill amount is critical for correct coagulation analysis. All LYBCON Vacutainer coagulation tubes have a mark indicating the minimum fill level. CENTRIFUGING CONDITIONS For coagulation analysis different plasma specifications can be obtained from the citrated blood. Platelet rich plasma:150-200g for 5 minutes at 18-25 C Platelet poor plasma:2000-2500g for 10-15 minutes at 18-25 C Platelet free plasma: >3000g for 15-30 minutes at 18-25 C MIXING RECOMMENDATION Citrate tubes should be gently inverted 180 and back 3-4 times. SPECIFICATION Specimen: Plasma or Whole Additive: Sodium citrate 3.2% or 3.8% (9NC) Cap color: Blue Tube Size: 13x75mm Draw Volume: 1.8mL, 2.7mL Max. draw volume Tolerance: ±10%
The tubes are designed for blood The tubes are designed for blood LYBCON Vacutainer sedimentation without the use of sedimentation pipettes. The blood is taken directly into the tubes and LYBCON Vacutainer turned end-over-end 8-10 times. Immediately before the tubes are placed in the stand for measurement, LYBCON Vacutainer the tubes must be mixed again. After one or two hours the results are read. The stand holds a LYBCON Vacutainer maximum of 10 tubes and has a height Lybcon adjustable zero mark. The measurement results achieved correspond to the Westergren method. MIXING RECOMMENDATION ESR (Erythrocyte Sedimentation Rate) tubes should be gently inverted 180 and back 8-10 times. SPECIFICATION Specimen: Whole Additive: Sodium citrate 3.8% (4NC) Cap color: Black Tube Size: 13x75mm Draw Volume: 1.6mL, 1.8mL Max. draw volume Tolerance: ±10% sedimentation without the use of sedimentation pipettes. The blood is taken directly into the tubes and LYBCON Vacutainer turned end-over-end 8-10 times. Immediately before the tubes are placed in the stand for measurement, LYBCON Vacutainer the tubes must be mixed again. After one or two hours the results are read. The stand holds a LYBCON Vacutainer maximum of 10 tubes and has a height LYBCON Vacutainer adjustable zero mark. The measurement results achieved correspond to the Westergren method. MIXING RECOMMENDATION ESR (Erythrocyte Sedimentation Rate) tubes should be gently inverted 180 and back 8-10 times. SPECIFICATION Specimen: Whole Additive: Sodium citrate 3.8% (4NC) Cap color: Black Tube Size: 13x75mm Draw Volume: 1.6mL, 1.8mL Max. draw volume Tolerance: ±10%
Vacuum Blood Collection Tubes.