(1) Combining with domestic actual production demand, this machine is equipped with completely automatic machinery equipment integrating automatic tube filling, coagulant dosing and atomizing, drying, capping, vacuum capping, tube taking and tray packing;
(2) This machine comprehensively adopts programmable control and pneumatic actuator. According to the product feature of vacuum blood collection tube, control all actuation actions of machinery in organic combination form via program and software;
(3) This machine is equipped with automatic heat shrink packaging machine, so as to achieve packing automation and fully automatic modular production;
(4) This machine adopts South Koreas Sejong bivalve and multi-function software control system to achieve dosing and atomizing; it also adopts two sets of 100-head plug-in hot air dryer, which can grasp the cap conveying device for 100 assembled caps, one full-automatic vacuum compensated-type vacuum capping machine and the tube taking and foam tray mechanism which can grasp 100 finished tubes simultaneously; after removing the tube, insert it into the foam packing tray mechanism, control such mechanism actions via programmable program and execute via pneumatic mechanism, in which way all procedures will be completed fully automatically, including BCA coagulant dosing, drying, capping, vacuum capping, tube taking and tray packing. This machine features high automation degree, high production efficiency, stable performance, low failure rate, easy operation, low maintenance fee, etc.
(5) It is able to install oblique foam tray online according to customers demand.
6.Packing:Customized production as requested. Normal carton size as follows:
100pcs/foam tray,1200pcs/carton
13x75mm: 515*360*183mm/1200pcs
13*100mm: 515*360*233mm/1200pcs
16*100mm:580*390*233mm/1200pc
7.Certificate:CE & ISO13485 certificate approved
8.Tray material: Foam 9. Cap color:red
10.Delivery time:15-25 days depend on order size
11.Label and logo printing: as requested
12.Shelf time: PET-18 months, glass-24months
13.Storage: No direct sunlight at room temperature
You are warmly welcome to visit our company and we expect highly to win-win cooperation with you! Now contact me:
Felix Ma
161;244;tube loading161;adust absorption161;atube reverse checking--reagent dosing( spray/filling)161;adrying system161;aautomatic adding cap161;avacuum capping161;apick up tubes onto foam rack161;atest tube tray recycling system; all the above steps automatically finished online.
Main technical parameter¡o
1. Suitable specification tube¡o13*75mm, 13*100mm pet tube/ glass tube; for 16*100mm tube, only by changing some accessories.
2. Caps: round, flat shape caps can be used in same line.
3. Reagent dispensing nozzles¡o2 nozzles (nordson efd)
4. Filling or spraying precision: 161;
5. Vacuum precision: 161;¨
6. Drying stations¡o4 stations
7. Production capacity: 16000pcs/hour.
8. Air pressure¡o0.8mpa
9. Air consumption¡o20m3/h
10.Power¡oac380v 50/60hz
11.Power consumption¡o15kw
Sterile Vacuum blood collection tube for single use:
Sizes: 1ml, 2ml, 3ml;, 5ml, 10ml.
SPEC: non-additive, additive.
Product structure: test tube, piston, plastic cap.
Product instruction: The products are made by medical glass, or highly transparent medical plastic materials.
The products are matched with vacuum blood collection sets, and used as per the theory of negative pressure, and suck blood into the storage tube by the connecting tube, and can step the way of one vacuum blood collection needle with more storage tubes.
Technical indication: Additive dosage of the products are accurate, blood sample capacities are also accurate.
Scope for use: The products are used for collecting blood in clinic
EPGT tube stands on EDTAK2 with Gel Tube. It is coated with lithium heparin and inside the tube a barrier Gel presented at the bottom.
Product Feature
they are normally made of glass and plastic. In addition, the plastic tube includes PET, PP and PS.
Product Specification/Models
1ml 13í-75mm VP10041S
2ml VP20031S
3ml VP30031S
4ml 13í-100mm VP40042S
5ml VP50032S
6ml VP60032S
8ml 16í-100mm VP80043S
9ml VP90043S
Application. Through centrifugation, the separation gel can form a barrier between plasma and blood cell and totally separate them. Clinical specimen obtained is suitable for analysis of virus capacity and molecular diagnostics of undiluted plasms.
Other Information
We are professional manufactory dealing especially with the export of blood collection kits. We are in a position to accept orders according to the customer's samples.
Product feature
They are normally made of glass and plastic. In addition, the plastic tube includes pet , pp and ps.
Product specification/models
3ml 13íß75mm vp30011s
4ml vp40011s
5ml vp50011s
3ml 13íß100mmvp30012s
4ml vp40012s
5ml vp50012s
6ml vp60012s
8ml 16íß100mmvp80013s
9ml vp90013s
Application
It is used for collecting blood specimen for biochemistry and immunology tests, especially fast in blood coagulation.
Other information
We are professional manufactory dealing especially with the export of blood collection kits. We are in a position to accept orders according to the customer's samples.
Ssgt tube stands on clot activator with gel tube. It is coated with clot activator and inside the tube a barrier gel presented at the bottom.
Product feature
They are normally made of glass and plastic. In addition, the plastic tube includes pet, pp and ps.
Product specification/models
3ml 13íß75mm vp30021s
3.5ml vp35021s
3ml 13íß100mm vp30022s
4ml vp40022s
5ml vp50022s
7ml 16íß100mm vp70023s
8ml vp80023s
Application
It is used for clinical biochemistry and immunology. The obvious characteristic of ssgt tube is used to obtain high-quality plasma specimen for medical laboratories.
Other information
We are professional manufactory dealing especially with the export of blood collection kits. We are in a position to accept orders according to the customer's samples.
Product specification/models
Infant blood collection tube: 8*45mm
Color: red, yellow, lavender, green, black, gray, blue.
Application
It's used for children's blood collection
Other information
We are professional manufactory dealing especially with the export of blood collection kits. We are in a position to accept orders according to the customer's samples.
EDTA salts (ethylene diamine tetra acetic acid) are used for the anticoagulation of whole blood for haematological investigations as the cellular components of the blood are particularly well preserved by EDTA. It works as an anticoagulant as it forms complexes with metal ions such as calcium, therefore inhibiting the coagulation cascade. Anticoagulation with EDTA is irreversible. The EDTA concentration in tubes is LYBCON Vacutainer 1.8mg per ml of complete blood when the fill level is correct, as recommended by the ICSH (International Council Society of Haematology) and the CLSI (Clinical and Laboratory standards institute). The institutes recommend dipotassium EDTA salt (K EDTA) for 2 haematological investigation. K EDTA is used in 2 LYBCON Vacutainer tubes in spray dried form.
CE&ISO certified professional manufacturer of medical supplies lab consumables vacutainer since2009-Hebei
Vacuum blood collection tubes are applicable to the clinical blood test and the blood cells analysis
The internal walls of the tubes are coated with different additives designed to stabilize and preserve the specimen prior to
analytical testing
*Red: Non-additive - Serum
*Red: Clot Activator-Serum
*Yellow: Gel & Clot Activator -Serum
*Purple: ETDA K2 / ETDA K3 - Whole blood
*Black: 3.8% Sodium Citrate (1:4)- Whole blood
*Blue: 3.2% Sodium Citrate (1:9)- Whole blood or Plasma
*Green: Lithium Heparin / Sodium Heparin-Plasma
*Grey: Glucose - Plasma
SERUM TUBES In order to obtain serum samples from plastic tubes, the tube must have coagulation activator added. As the plastic suface alone is insufficient to trigger the coagulation within an acceptable time, LYBCON VACUTAINER serum tubes have silica particles added for this purpose. CLOTTING TIMES The recommended minimum time for the coagulation of samples from patients who have not been treated with anticoagulants is 30- 45 minutes for serum (red).
Specification:50ml,60ml,100ml
Unique labeling urine collection hole makes urine collecting and transferring convenient sanitary and safe. This container can prevent outer substance and bacteria contaminating urine specimen and urine spilling, which maximally avoids the risk of contacting pathogenic urine specimen by patient and medial people. The label is easy to tear and re-seal.
LYBCON Vacutainer GEL-SST Advance tubes
During the centrifugation of the LYBCON Vacutainer GEL-SST Advance tubes, an inert LYBCON Vacutainer gel separates the serum and the blood clot preventing the contamination of the serum from the separated cellular components.
For example, the serum for certain analytes such as potassium, phosphorus and glucose must be separated from the cells within a few hours - otherwise the results will be significantly distorted.
Using LYBCON GEL-SST Advance tubes routine analyses in clinical chemistry such as potassium and glucose are still stable after a week of storage at 2-8 C. Clinical evaluations of special chemistry demonstrate a high degree of analyte stability with the acrylic gel in the LYBCON GEL-SST Advance, with detection of >90% of the therapeutic drugs and other special analytes(proteins/peptides, steroids and vitamins) tested.
As a result of the type of gel used in the GEL-SST Advance tubes, LYBCON Vacutainer short centrifugation times of 5 minutes at 3000g can be achieved. The stability of the gel barrier is a distinct advantage during transport and storage.
The main advantages of gel tubes versus non-gel tubes are:
Stable barrier between serum and clotted blood, therefore better analyse stability.
Better sample quality.
Optimisation of the work flow: Short centrifugation time, sample processing and archiving in the primary tube.
No possibility of misidentification due to the use of secondary tubes.
CLOTTING TIMES
The minimum recommended coagulation time for GEL-SST Advance tubes for patients who have not LYBCON Vacutainer received anticoagulation treatment is 30 minutes.
CENTRIFUGING CONDITIONS
1600-2000g for 10 minutes
MIXING RECOMMENDATION
Serum Separation Tubes should be gently inverted 180 and back 6-8 times.
EFFECTS OF TEMPERATURE
LYBCON Vacutainer GEL-SST Advance should be stored at 4-25C and protected from direct sunlight during storage. Cooling of the tube by or during centrifuging can affect the movement capability of the gel. The optimum separation of serum and coagulated blood is achieved at a temperature of 20-25C.
Serum Separation Tubes should be gently inverted 180 and back 6-8 times.