The Rubella IgG GENLISATM ELISA is intended for the qualitative determination of Rubella Virus IgG class antibodies in human serum and plasma. ELISA 96 wells
General Information One-Step Dengue Rapid Test is to detect IgG&IgM antibodies in serum, plasma or whole blood. For Dengue IgG/IgM Ab test: Sensitivity : 99.9% , Specificity : 99.5% Specimen : Serum , Plasma and Whole Blood Reading Time : 10 min
Dengue rapid test kit.
The FactView Dengue IgG/IgM Antibody Combo test is a diagnostic assay used for the simultaneous detection of both IgG and IgM antibodies produced by the immune system in response to dengue virus infection. Here's more information about this type of diagnostic test: Purpose: The test is used for the diagnosis of dengue virus infection in patients presenting with symptoms consistent with dengue fever or other dengue-related illnesses. Dengue is a mosquito-borne viral infection caused by four closely related viruses (DENV-1, DENV-2, DENV-3, and DENV-4) transmitted by Aedes mosquitoes. Principle: The FactView Dengue IgG/IgM Antibody Combo test is an immunochromatographic assay that detects the presence of both IgG and IgM antibodies in a patient's blood sample. IgM antibodies are typically produced during the acute phase of infection, while IgG antibodies are produced later during the convalescent phase and provide long-term immunity. Components: The test typically includes test cassettes, sample droppers, buffer solutions, and desiccants. The test cassettes contain pre-coated membranes with specific antigens for capturing IgG and IgM antibodies. Procedure: The test procedure involves collecting a small amount of blood from the patient (usually obtained via finger prick) and applying it to the sample well of the test cassette. Buffer solution is then added, allowing the blood sample to migrate along the test strip. Results are typically visible within 15-20 minutes. Interpretation: The appearance of colored lines on the test strip indicates the presence or absence of IgG and IgM antibodies. A visible line in the control region indicates that the test is valid. Additional lines in the test region(s) indicate positive results for IgG and/or IgM antibodies. Sensitivity and Specificity: The FactView Dengue IgG/IgM Antibody Combo test demonstrates high sensitivity and specificity for detecting dengue virus infection. However, like all diagnostic tests, false-positive and false-negative results are possible and should be interpreted in conjunction with clinical findings. Utility: The rapid detection of IgG and IgM antibodies against dengue virus provides valuable information for diagnosing acute or recent dengue virus infection, determining immune status, and guiding patient management decisions.
Product Details: Number of Reactions(Preps)/Kit 30 Brand : CTK BioTech Result Time (Rapid Kits) :20-25 Min Sample Material :Serum / Plasma / Whole Blood Cat. No : R0061c The OnSite Dengue IgG/IgM 3.0 Combo Rapid Test is a lateral flow immunoassay for the simultaneous detection and differentiation of IgG and IgM antiâ??dengue virus (DEN1, 2, 3 and 4) in human serum, plasma or whole blood. Product Features: Utilizes recombinant chimeric dengue virus licensed from the US CDC Detects all four dengue serotypes IgM detection indicates recent infection IgG detection indicates recent or previous infections Each kit contains: Individually sealed foil pouches containing: One cassette device One desiccant 5 AUL Capillary tubes Sample diluent (REF SB-R0061, 5 mL/bottle) One package insert (instruction for use)
Product Details: Number of Reactions(Preps)/Kit : 50 Brand : SD ICMR Approved : Yes Result Time (Rapid Kits) : 15 min Sample Type : Oral & Nasal Swab STANDARD E Dengue IgM ELISA analyzes IgM antibodies specific to Dengue virus in serum and plasma using enzyme linked immunosorbent assay.
The Anti-Cardiolipin IgA GENLISATM ELISA is intended for the qualitative determination of Anti Cardiolipin IgA antibody in human serum and plasma. Pack Size - ELISA 96 wells
The HSV 1 IgG GENLISA ELISA is intended for the qualitative determination of HSV 1 IgG in human serum and plasma. Pack Size - ELISA 96 wells
1. Principle This test kit is based on the competitive enzyme immunoassay for the detection of Gentamicin in the sample. The coupling antigen is pre-coated on the micro-well stripes. The Gentamicin in the sample and pre-coated coupling antigen on the micro-well stripes compete for the anti-Gentamicin antibody. After the addition of the enzyme conjugate, the TMB substrate is added for coloration. The optical density (OD) value of the sample has a negative correlation with the Gentamicin in it. The value is compared to the standard curve and the Gentamicin concentration is subsequently obtained. 2. Technical specifications Sensitivity: 0.05 ppb Incubator temperature: 25 Incubator time: 30minï½?15min
1. Principle This test kit is based on the competitive enzyme immunoassay for the detection of Florfenicol in samples. The coupling antigens are pre-coated on the micro-well stripes. The Florfenicol in the sample and the conjugate antigens pre-coated on the micro-well stripes compete for the anti-Florfenicol antibodies. After the addition of the enzyme conjugate, the TMB substrate is added for coloration. The optical density (OD) value has a negative correlation with the Florfenicol concentration in the sample. This value is compared to the standard curve and the Florfenicol concentration is subsequently obtained. 2. Technical specifications Sensitivity: 0.1 ppb Incubator temperature: 25 Incubator time: 30minï½?15min
1. Principle This test kit is based on the competitive enzyme immunoassay for the detection of Tylosin in the sample. The coupling antigens are pre-coated on the micro-well stripes. The Tylosin in the sample and the coupling antigens pre-coated on the micro-well stripes compete for the anti-Tylosin antibody. After the addition of the enzyme conjugate, the TMB substrate is added for coloration. The optical density (OD) value of the sample has a negative correlation with the Tylosin in it. This value is compared to the standard curve and the Tylosin concentration is subsequently obtained. 2. Technical specifications Sensitivity: 0.5 ppb Incubator temperature: 25 Incubator time: 75 min
The kit uses a double-antibody sandwich enzyme-linked immunosorbent assay (ELISA) to assay the level of Human Androgen in samples. Add Androgen to monoclonal antibody Enzyme well which is pre-coated with Human Androgenmonoclonal antibody, incubation; then, add Androgenantibodies labeled with biotin, and combined with Streptavidin-HRP to form immune complex; then carry out incubation and washing again to remove the uncombined enzyme. Then add Chromogen Solution A, B, the color of the liquid changes into the blue, And at the effect of acid, the color finally becomes yellow. The chroma of color and the concentration of the Human Substance Androgen of sample were positively correlated. Standard; 128nmol/L.
Chloramphenicol elisa test kit 1. Principle This test kit is based on the competitive enzyme immunoassay for the detection of chloramphenicol in the tissue (chicken, pork), honey, milk, fish, shrimp and egg. The coupling antigen is pre-coated on the micro-well stripes. The chloramphenicol in the testing sample competes with the coupling antigen pre-coated on the micro-well stripes for the antibody against chloramphenicol. After the addition of the enzyme conjugate, the tmb substrate is added for coloration. The optical density (od) value of the testing sample has a negative correlation with the content of chloramphenicol in it. This value is compared to the standard curve and the content of the corresponding chloramphenicol is subsequently obtained. 2. Technical specifications Sensitivity : 0.05ppb Detection limit: Egg, intestine0.1 ppb Honey0.15ppb Milk0.05 ppb Urine and serum0.1 ppb Chicken, pork, fish, shrimp0.05 ppb Recovery rate Chicken, pork, fish, shrimp80%+10% Honey70%+10% Milk85%+15% Cross-reaction rate: Chloramphenicol100% Thiamphenicol
Ractopamine elisa test kit Technical specifications Sensitivity : 0.5 ppb Detection limit Muscle 1ppb Liver--2ppb Urine-1ppb Admixture-25ppb Contrated material , premix material-75ppb Recovery rate Urine--85+10% Muscle and liver--80+10% Cross-reactions Ractopamine---100% Dobutamine-10% Clenbuterol 0.1% Salbutamol -0.1% Weight:1.5kg Dimensions:24cm*16cm*11cm
Elisa test kits Name specification method Hav-igm 48 elisa serum without dilution Hav-igm 48 elisaserum with dilution Hav-igg 48 elisaserum with dilution Ana 48 elisa Anti-hbs Hbsag 2x48 elisa Anti-hbe 2x48 elisa Hbeag 2x48 elisa Anti-hbc 2x48 elisa Anti-hcv igm 48 elisa Anti-hcv igg 2x48 elisa Anti-hdv igm 48 elisa Anti-hdv igg 48 elisa Anti-hev igm 48 elisa Anti-hev igg 48 elisa Anti-hgv igm 48 elisa Anti-hgv igg 48 elisa Anti-hiv1/2 96 elisa Anti-uu 48 elisa Anti-mh 48 elisa Anti-mg 48 elisa Anti-ct 48 elisa Anti-ng 48 elisa Cmv-igm 48 elisa Toxo-igg 48 elisa Toxo-igm 48 elisa Rv-igg 48 elisa Rv-igm 48 elisa Hsv(no.1)igm 48 elisa Hsv(no.2)igm 48 elisa Anti-sperm igm 48 elisa Anti-sperm igg 48 elisa Anti-mg igm 48 elisa Anti-mg igg 48 elisa Anti-acl 48 elisa Hcg-igm 48 elisa Hcg-igg 48 elisa Anti-mp 48 elisa Anti-cpn 48 elisa Anti-hp 48 elisa Anti-tpg 48 elisa Anti-hcmv 2x48 elisa Anti-psa 2x48 elisa Anti-cea 2x48 elisa Anti-hpv 48 elisa Anti-av 48 elisa Anti-tb 48 elisa Anti-cvb 48 elisa Serum fe 48 elisa Anti dna 4 centigrade test box Hbv kit 20 pcr Hpr kit 20 pcr Ng kit 20 pcr Hsv kit 20 pcr Ct kit 20 pcr Uu kit 20 pcr Ebv kit 20 pcr Mp kit 20 pcr B19 kit 20 pcr Vc kit 20 pcr Sh kit 20 pcr St kit 20 pcr Lp kit 20 pcr Sau kit 20 pcr Tpg kit 20 pcr Mg kit 20 pcr Mh kit 20 pcr Hp kit 20 pcr Anti-dna-tm-hyb kit Ct-hyb kit 16 pcr Hbv hyb kit 16 pcr Tb hyb kit 16 pcr Hcv hyb kit 16 pcr Ng hyb kit 16 pcr Uu hyb kit 16 pcr Hpv hyb kit 16 pcr Hsv hyb kit 16 pcr Mp hyb kit 16 pcr Hgv hyb kit 16 pcr Cvb hyb kit 16 pcr Telomerase trap hyb kit 16 pcr Hot-start taq dna poly 20 pcr Rt 20 pcr Rt-rna enzyme mix kit 20 pcr Rna test kit Hcv kit 10 pcr Hrv kit 10 pcr Hiv kit 10 pcr Rv kit 10 pcr Jbev kit 10 pcr Cvb kit 10 pcr Hgv kit 10 pcr Uu media kit 6 Mh media kit 6 Mg media kit 6
Product Details: Size 96 wells/Plate Format Indirect Incubation Time 30 + 30 + 5 + 10 + 1 Sample Type Serum Storage 2-8 C Cat No STGS-R The Scrub Typhus Detectâ?¢ IgG ELISA test for exposure to Orientia tsutsugamushi (OT; formerly Rickettsia) is an ELISA assay system for the detection of IgG antibodies in human serum to OT-derived recombinant antigen. For research use only. Not for use in diagnostic procedures. The complete kit includes one 96 well strippable plate with all necessary reagents and controls.
Product Details: Brand J.Mithra Test Kit Type: Dengue Test Kit (Rapid) Sensitivity & Specificity High Shelf Life: 30 months at 2-30 DegreeC Pack Size: 10, 30 & 50 Tests Cat. No IR028010 Intended Use : Dengue Day 1 Test is a rapid solid phase immuno-chromatographic test for the qualitative detection of Dengue NS1 Antigen and differential detection of IgM and IgG antibodies to Dengue virus in Human serum/plasma. This test is for in vitro diagnostic use only and is intended as an aid in the earlier diagnosis of Dengue infection & presumptive diagnosis between primary and secondary Dengue infection. Salient Features: First line testing kit for detecting dengue infection from day 1 using NS1 Antigen & differential detection of IgM & IgG Antibodies. Diagnosis of both Primary & Secondary Infection. Detection of all the 4 Dengue serotypes (DEN-1, DEN-2, DEN-3 and DEN-4). Highly Sensitive & Highly Specific Long shelf life: 30 months at 2-30 C. Convenient pack sizes: 10 Tests, 30 Tests & 50 Tests. Principle:Dengue Day 1 test kit consists of two devices: one device for detection of Dengue NS1 antigen and second device for the differential detection of Dengue IgM/IgG antibodies in Human serum/plasma. Dengue NS1 Antigen device contains two lines; (Control line) & T (Dengue NS1 Antigen test line). Test line is coated with anti-dengue NS1 Ag. When a sample is added to the device, Dengue NS1 antigen if present in the sample will bind to the anti-dengue NS1 gold colloidal conjugate making antigen antibodies complex. This complex migrates along the membrane to the test region and forms the visible pink line at as antibody-antigen-antibody gold colloid forms. Dengue IgM/IgG test device contains three lines; C (Control line), M (IgM test line) & G (IgG test line).IgM test line is coated with anti-human IgM and IgG test line is coated with anti-human IgG.When a sample is added to the device, IgG and IgM antibodies in the sample react with anti-human IgM or IgG antibodies coated on the membrane respectively. Colloidal gold complexes containing dengue 1-4 antigens is captured by the bound anti-dengue IgM or IgG on respective test bands located in the test window causing a pale to dark red band to form at the IgG or IgM region of the test device window. The intensity of the test bands in the respective device will vary depending upon the amount of antigen /antibody present in the sample. The appearance of any pink/ red colour in a specific test region should be considered as positive for that particular antigen and/or antibody type (IgG or IgM). A red procedural control line should always develop in the test device window to indicate that the test has been performed properly Dengue NS1 Ag : Sensitivity 96% and Specificity 98%. Dengue IgM/IgG Antibody test : Sensitivity 95% and Specificity 97%.
Cat.No - TO-E0010 Size - 96T Price - 39375
Cat.No - TO-E0013 Size - 96T Price - 39375
Cat.No - TO-E0012 Size - 96T Price - 39375