made in china brand new Automotive Air Conditioning condensers for Audi 2.7L 2671CC V6 GAS DOHC Turbocharged 8D0260403G TuYoung ID: HY-CN262 specification size:- material:aluminium refrigeramt:R134a OEM# 8D0260403G 8D0260401G Car model: 2002 Audi S4 Avant Wagon 4-Door 2.7L 2671CC V6 GAS DOHC Turbocharged 2002 Audi S4 Base Sedan 4-Door 2.7L 2671CC V6 GAS DOHC Turbocharged 2001 Audi S4 Avant Wagon 4-Door 2.7L 2671CC V6 GAS DOHC Turbocharged 2001 Audi S4 Base Sedan 4-Door 2.7L 2671CC V6 GAS DOHC Turbocharged 2000 Audi S4 Base Sedan 4-Door 2.7L 2671CC V6 GAS DOHC Turbocharged
CW1 series intelligent universal circuit breaker (hereinafter referred to as circuit breaker), Apply to 50Hz AC, Rated voltage to 660V (690V) and below, in the distribution network with rated current of 200A ~6300A, circuit break used to distribute electric energy and protect circuit and power equipment from overload, undervoltage, shortcircuit, single-phase grounding and other faults has intelligent protection function. Selective protection is accurate, it can improve the reliability of power supply, avoid unnecessary power failure, and has an open communication interface. It can carryout "four remote" to meet the requirements of the control center and the automation system. The circuit breaker has a pulse withstand voltage of 8000V at an altitude of 2000 meters (the maximum withstand voltage is not more than 12000V according to the standard for different altitudes). The circuit breaker can be used as an isolator without intelligent controller and sensor, and is marked as -*The circuit breaker conforms to GB14048.2 "Low Voltage Switchgear and Control Equipment Low Voltage Circuit Breaker" and EC60947-2 "Low Voltage Switchgear and Control Equipment Circuit Breaker" and other standards. Normal Working and Installation Conditions Ambient air temperature The upper limit value shall not exceed +40 �ºC, the lower limit value shall not be lower than-5 �ºC, and the 24-hour average value shall not exceed +30 C; Note: For working conditions with the lower limit value of-10 C or-25 C, the user should declare it with the company. For working conditions where the upper limit value exceeds + 40T: or the lower limit value is lower than-10 C or-25 C, the user shall negotiate with the company; The altitude of the installation site shall not exceed 2000m. Atmospheric conditions The atmospheric relative humidity shall not exceed 50% when the ambient air is + 40 C, and may have higher relative humidity at lower temperatures. The monthly average maximum relative humidity in the wettest month is 90%, and the average minimum temperature in that month is + 25 C. Considering that the condensation on the product surface due to temperature change exceeds the specified requirements, the company shall be consulted. Protection level: IP30 Pollution level: III Use category: category B or category A Installation category Circuit breakers with rated working voltage of 660V (690V) and below, undervoltage releases and primary coils of power transformers are used for installation of Class IV; The installation category of auxiliary circuits and control circuits is III; The circuit breaker shall be installed according to the requirements of this specification. The vertical inclination of the circuit breaker shall not exceed 5 degrees (the inclination of the mine circuit breaker shall not exceed 15 degrees).
CW1 series intelligent universal circuit breaker (hereinafter referred to as circuit breaker), Apply to 50Hz AC, Rated voltage to 660V (690V) and below, in the distribution network with rated current of 200A ~6300A, circuit break used to distribute electric energy and protect circuit and power equipment from overload, undervoltage, shortcircuit, single-phase grounding and other faults has intelligent protection function. Selective protection is accurate, it can improve the reliability of power supply, avoid unnecessary power failure, and has an open communication interface. It can carryout "four remote" to meet the requirements of the control center and the automation system. The circuit breaker has a pulse withstand voltage of 8000V at an altitude of 2000 meters (the maximum withstand voltage is not more than 12000V according to the standard for different altitudes). The circuit breaker can be used as an isolator without intelligent controller and sensor, and is marked as -*The circuit breaker conforms to GB14048.2 "Low Voltage Switchgear and Control Equipment Low Voltage Circuit Breaker" and EC60947-2 "Low Voltage Switchgear and Control Equipment Circuit Breaker" and other standards. Normal Working and Installation Conditions Ambient air temperature The upper limit value shall not exceed +40 �ºC, the lower limit value shall not be lower than-5 �ºC, and the 24-hour average value shall not exceed +30 C; Note: For working conditions with the lower limit value of-10 C or-25 C, the user should declare it with the company. For working conditions where the upper limit value exceeds + 40T: or the lower limit value is lower than-10 C or-25 C, the user shall negotiate with the company; The altitude of the installation site shall not exceed 2000m. Atmospheric conditions The atmospheric relative humidity shall not exceed 50% when the ambient air is + 40 C, and may have higher relative humidity at lower temperatures. The monthly average maximum relative humidity in the wettest month is 90%, and the average minimum temperature in that month is + 25 �ºC. Considering that the condensation on the product surface due to temperature change exceeds the specified requirements, the company shall be consulted. Protection level: IP30 Pollution level: III Use category: category B or category A Installation category Circuit breakers with rated working voltage of 660V (690V) and below, undervoltage releases and primary coils of power transformers are used for installation of Class IV; The installation category of auxiliary circuits and control circuits is III; The circuit breaker shall be installed according to the requirements of this specification. The vertical inclination of the circuit breaker shall not exceed 5 degrees (the inclination of the mine circuit breaker shall not exceed 15 degrees).
Auto AC Condenser Car AC Condenser for TOYOTA VITS 03 Auto AC Condenser Car AC Condenser for TOYOTA VITS 03 Auto AC Condenser for TOYOTA VITS 03 Items FEATURES Core size 530*340*16mm Core thickness 16mm Car Model TOYOTA VITS 03 OEM N/A Type Parallel Flow Inner package Foam, honeycomb or card Outer package Neutral package or color boxes as your demand delivery 30 days after we get your payment We do supply many types of auto ac condensers for different car makes and models, for Toyota, Honda, Nissan, BMW, Hyundai, Benz, VW, Ford, AUDI, Dodge, GMC, Mazda, etc. If you have any requirement, pls feel free to send your inquiry here. The soonest reply with best price will be for you! Thanks for your time!!
Auto AC Condenser Car AC Condenser for TOYOTA VITS 03 Auto AC Condenser Car AC Condenser for TOYOTA VITS 03 Auto AC Condenser for TOYOTA VITS 03 Items FEATURES Core size 530*340*16mm Core thickness 16mm Car Model TOYOTA VITS 03 OEM N/A Type Parallel Flow Inner package Foam, honeycomb or card Outer package Neutral package or color boxes as your demand delivery 30 days after we get your payment We do supply many types of auto ac condensers for different car makes and models, for Toyota, Honda, Nissan, BMW, Hyundai, Benz, VW, Ford, AUDI, Dodge, GMC, Mazda, etc. If you have any requirement, pls feel free to send your inquiry here. The soonest reply with best price will be for you! Thanks for your time!!
Sjr3-2000 series is the latest soft starter developed by our factory.It expands new function such as literal display, industrial communication and various protections based on the products of sjr2 series.This product will be the upgrading and replacement of sjr2 series eventually. It shares the same technical framework with sjr3-3000. The applicable standards:iec 60947-2-2:2002 Brand name:safesave Model number:sjr3-2000 r2 Output power:1 - 200kw Output type:triple Size:400*270*240mm Weight:20.5kg Input voltage:110v/120v/220v/230v Output voltage:0-380v Type:ac/ac inverters Output frequency:0~3200hz Output current:load Certification:ccc, ce, iso9001 Protective class:ip20 Warranty:1 year Packaging details: Standard export packing Delivery detail: Wthin 30 days
Model HQ15-A5 HQ15-A100 Rated primary current 5A AC 100A AC Output Voltage 10 mV AC/A 1mV AC/A Maximum input current 50A AC (Continuous) 130A AC (Continuous) (45-66Hz,Ambient temp.50C) Amplitude accuracy ±0.3%RD ±0.02%FS (10%-100%I1n),(45Hz- 66Hz) Phase accuracy ±2 (10%-100%I1n)(45Hz-5kHZ) The amplitude frequency characteristic ±0.1% (45Hz-5kHZ)(Deviation accuracy) Conductor impact ±0.5 (Off-center) The influence of external lectromagnetic fields 0.1A (In AC 400A / m electromagnetic fields) Temperature coefficient ±0.02%/C of the reading data Dielectric strength 3000 V AC rms/Continue 15 seconds(Circuits-iron core, iron core-shell) The maximum rated voltage 300V AC rms Applicable standards Safety: EN61010-2-032:2002,300V CAT III, Contamination II EMC: EN61326:1997+A1:1998+A2:2001+A3:2003(Class A) Mechanical parameters Measurable conductor diameter Max.15mm Cable length About 3m Dimension (W x H x D) About 46135 21 (Excluding protruding parts) Weight About 230g Environmental conditions Operating temperature 0 to 50 C (32-122 F) Operating humidity 80%RH(No condensate) Storage temperature -10 to 60 C (14-140F) Storage humidity 80%RH(No condensate) Operating environment Indoor, altitude up to 2000 meters
FORD / MAZDA RANGER PJ-PK / MAZDA BT50 2006-2011 Ford f-150 2011 Onwards Ford Ranger PK/PJ 2009-2011 2006-2009 Ford Ranger T6/PX All Models 08/2011 Onwards Ford Ranger T7 2016 onwards HYUNDAI GALLOPER EXCEED 1998-2000 GALLOPER SUPER EXCEED 2000-2003 ISUZU / OPEL D-MAX 2008-2012 D-MAX 2012 Onwards D-MAX 2012 Onwards ISUZU RODEO 1997-2001 RODEO / CAMPO / FRONTERA B 1988-1996 JACKAROO/TROOPER Diesel 1998-2004 JACKAROO / TROOPER Petrol 1992-1997 TROOPER / MONTEREY 1992-2004 JEEP CHEROKEE XJ 1985-2001 CHEROKEE KJ 2002-2007 GRAND CHEROKEE ZJ 1993-1998 GRAND CHEROKEE WJ 1999-2004 WRANGLER YJ 1987-1996 WRANGLER TJ 1992-2006 WRANGLER JK 2003 Onwards LAND ROVER DEFENDER 200 1990-1994 DEFENDER 110 1987-2012 Defender TD5 1999 onwards DEFENDER 300 / TD5 / TD4 1994 Onwards DISCOVERY 300 1994-1998 DISCOVERY 3 / 4 2005 Onwards Defender TD4 Diesel 1999 onwards MERCEDES SPRINTER 2006 Onwards MITSUBISHI L200 MH 1989-1996 Triton L200 MK / SPORT 1996-2006 Triton L200 ML / MN / SPORT 2006 Onwards Triton MQ 2015 Onwards Challenger PB / Sport 06 Pajero Shogun V33 / V6 1991-1999 Delica L400 1994-2006 PAJERO 1 / MONTERO 1 / NA 1983-1990 PAJERO V31 -V32 NH-NJ,PAJERO 2 / MONTERO 2 / NH 1990-1997 PAJERO 3 / MONTERO 3 / NM/V73A 2000-2006 PAJERO 4 / MONTERO 4 / NS-T-W 2007 Onwards NISSAN NAVARA D21 / PICKUP / TERRANO NAVARA D22 / NP300 / TERRANO II* 1993-2010 NAVARA D40 / PATHFINDER R51 2005-2009 NAVARA D40 / PATHFINDER R51 2010 Onwards PATROL Y160A MQ/MK / 260 1980-2002 Patrol GQ (Y60) Patrol 1988-1997 PATROL Y60 1988-1997 PATROL Y61-Petrol 1998-2004 GU Patrol Wagon (Y61) GU Series 1 Diesel 1997-2000 SS15HFB & SS16R GU Patrol WagonGU(Y61) Series 4 Petrol 2005 Onwards PATROL Y61 2005 Onwards SUZUKI JIMNY 1998 Onwards SAMURAI / SJ 1984-1997 VITARA 1990-1998 GRAND VITARA 2006 Onwards TOYOTA FJ CRUISER 2006 Onwards Hilux106 Series Diesel 1989-1997 HILUX 105 / 106 / 4RUNNER 1989-1997 HILUX 167 1998-2005 HILUX 167 1998-2005 Hilux 25 Petrol 2005 Onwards HILUX 25 Diesel 2005 Onwards Hilux Revo 2015 Right Tacoma 2005-2015 Right Tacoma 2016 Onwards Right LAND CRUISER 40 series 1960-1984 LAND CRUISER 70 series 1985-2007 LAND CRUISER 70 series 1985-2007 LAND CRUISER 70 series 2007 Onwards LAND CRUISER 80 series 1990-1998 LAND CRUISER 90 series RHD 1997-2002 LAND CRUISER 90 series LHD 1997-2002 100 series Landcruiser / Lexus LX 470(old design)1998-2007 LAND CRUISER 100 series 1998-2007 LAND CRUISER 120 series 2002-2009 LAND CRUISER 150 series 2009 Onwards LAND CRUISER 200 series 2008 Onwards VOLKSWAGEN AMAROK 2010 Onwards CRAFTER 2006 Onwards Chevrolet Hoden Colorado RC 4JJ1 Mazda BT50 B3000 Diesel Bravo Mark 6 /COURIER Diese l
FEATURES Most cost-effective Faster installation Safe and easy installations High accuracy 0.5 Holding wire diameter: �?16mm Measurement range of 1mA to 200A AC Low phase shift for power measurement Output model: Lead output(2.5m) Isolated plastic case recognized according to UL94-V0 Small-size, compact size, light-weight Over-Voltage protection circuit is installed. CE, UL / EN 61010 - 1 certified PARAMETERS Technical parameters Standards IEC/EN60044-1 & IEC61010-1 & IEC61869-2&ANSI C57.13 Ratio 1000: 1 or 2000:1 , customized Nominal input current Primary current 20A/30A/40A/50A/60A/80A/100A/150A/200A Overload withstand 1.2 times rated current continuously Accuracy 0.2%, 0.5 %, 1% System Voltage 720V(0.72kV) Output signal 10mA-200mA AC optional 333mV AC or 100mV-2V optional Frequency range 40 Hz-500 Hz Dielectric strength 3KV 50Hz/60Hz at 1 minute Output Standard 2.5 meter cable Protection Level 3.0V0-P Installation Category CAT or CAT 600VAC Max. jaw opening 16 mm Mechanical parameters Dimensions (WDH) (mm) 38mm 55mm 18mm Weight(g) 60 Operating conditions Operating temperature -25C to +55C Relative Humidity 0-85% non-condensing Altitude