Main FeaturesAC/DC Current Sensor Model No.: MEWOI-DRK1D Name: MEWOI-DRK1D-50-500A AC/DC Ï?20mm Open-loop Hall current Sensor Jaw Size21mm Rated input Current IPN50 100 200 300 400 500 A Primary Current Measure range(IP)0~±100 0~±200 0~±400 0~±600 0~±800 0~±800 A Rated output voltage of secondary side2.5±1.25 ±1% V Power Supply Voltage VCCDC +5V ±5% V Current consumptionVCC=+5V 10 mA Galvanic isolation (Vd) 2.5KV /50Hz/1min
SO-E2-960 Limiting Current Type Sensor Oxygen Sensors When voltage is applied to a zirconia electrolyte cell, oxygen is pumped through the zirconia disc from the cathode side to the anode side because the carriers of the current flowing through the zirconia electrolyte are oxygen ions. By attaching a cap with a pinhole on the cathode side of the cell and by increasing the voltage over the cell the current shows saturation due to the rate limiting step in the transfer of oxygen to the cathode. This saturation current is called limiting current and is nearly proportional to the ambient oxygen concentration. Below the advantages of the oxygen sensor: measuring range 1.00 to 96.0 vol.% oxygen High accuracy For many types a more or less linear characteristic Small temperature dependence of the sensor signal Low interference with other gases Long service life In many cases "Single point calibration" necessary only once Applications: Medical Laboratory Food industry Household/Gastronomy Measuring technique Security technology/Monitoring (Electrical-) industry Characteristic Data: Measuring gas: Oxygen concentration Measuring medium: Gaseous atmosphere Measuring principle: Limiting current type sensor Measuring ranges: 1.00 - 96.0 vol.% O2 Response time (t90): 2 to 25 sec. (Depends on: sensor type, gas flow, measuring chamber) Sensor voltage / heating voltage / power consumption / heater cold resistance Sensor voltage: 0.7 to 1.6 Volt Heating voltage: 3.6 - 4.4 Volts Power consumption: 1.3 to 1.8 Watts (depends on application and packaging) Cold resistance: R( 25'C ) = 3.25 ohm ± 0.20 ohm Warm up time: Min. 30 s
HIT500 has a high gain and measurement 0.05% accuracy in the broad bandwidth range, due to the application of the multi-point zero-flux technology system and high-frequency ripple sensing channel on top of currently existing DC sensor technology. Accuracy: 0.05%. Linearity: 50ppm. Current Change Rate: 100A/us. Frequency bandwidth(-3dB): up to 100KHz. Insulation Voltage (Between primary and secondary): 5KV. Operation Temperature Range: -40 ~ 85.
BMS300 fluxgate transducer is made of an excitation magnetic ring and a control circuit. Under normal conditions, the control circuit generates a fixed excitation current frequency to alternately place the magnetic core at the maximum saturation point. When the measured current flows, the primary current is measured by detecting the symmetry of the saturation point. The BMS series is suitable for battery monitoring systems that require high accuracy and low offset. It can realize the isolation measurement between the primary current (high voltage) and the secondary current (12V system).
HIT600 has a high gain and measurement accuracy in the full bandwidth range, due to the application of the multi-point zero-flux technology system and high-frequency ripple sensing channel on top of currently existing DC sensor technology. Primary Nominal Current: DC600A, AC424A, Overload Capacity: DC720A for 1 minute, Power Supply: DC14.2V to 15.8V, Ratio: 3000:1, Secondary Burden Resistance: 2 ~ 5�©, Accuracy: 0.05%, Linearity: 50ppm, Current Change Rate: 100A/us, Frequency bandwidth(-3dB): up to 100KHz, Insulation Voltage (Between primary and secondary): 5KV, Operation Temperature Range: -40 ~ 85.
IIT200 has a high gain and measurement accuracy in the full bandwidth range, due to the application of the multi-point zero-flux technology system and high-frequency ripple sensing channel on top of currently existing DC sensor technology. Primary Nominal Current: DC200A, AC141A, Overload Capacity: DC240A for 1 minute, Power Supply: DC14.2V to 15.8V, Ratio: 2000:1, Secondary Burden Resistance: 10 ~ 25, Accuracy: 0.02%, Linearity: 20ppm, Current Change Rate: 200A/us, Frequency bandwidth(-3dB): up to 100KHz, Insulation Voltage (Between primary and secondary): 5KV, Operation Temperature Range: -40 ~ 85.
The HQ15 100a current probe sensor is designed for easy installed in tight spaces and without the need for dismantling the primary busbar or cables. The sensing head uses sliding push-fit clamp structure, safety isolation to avoid the user to contact with charged objects directly. It complies with CE standards and meets 300V CAT III safety class. This model HQ15 current sensor is a high accuracy mini current probe for measurements up to 130A AC. This current probe uses a special magnetic core to provide higher accuracy and lower phase shift. The HQ15 Series is an excellent probe sensor to be used in power and low level current measurement applications. FEATURES UL, CE CNAS mark Excellent linearity High content permalloy core Holding wire diameter: 15mm Frequency 10Hz-5kHz Bandwidth High time harmonics measurement Easy &quick installation in tight spaces; Measurement range of 1mA to 130A AC; Low phase shift for power measurement; Â EN 61010-2-032 , 300V CAT III Standard Improved ergonomic design & easy operation; High precision 0.1% for current measurement Flexible and light weights, exquisite appearance;
Model HQ15-A5 HQ15-A100 Rated primary current 5A AC 100A AC Output Voltage 10 mV AC/A 1mV AC/A Maximum input current 50A AC (Continuous) 130A AC (Continuous) (45-66Hz,Ambient temp.50C) Amplitude accuracy ±0.3%RD ±0.02%FS (10%-100%I1n),(45Hz- 66Hz) Phase accuracy ±2 (10%-100%I1n)(45Hz-5kHZ) The amplitude frequency characteristic ±0.1% (45Hz-5kHZ)(Deviation accuracy) Conductor impact ±0.5 (Off-center) The influence of external lectromagnetic fields 0.1A (In AC 400A / m electromagnetic fields) Temperature coefficient ±0.02%/C of the reading data Dielectric strength 3000 V AC rms/Continue 15 seconds(Circuits-iron core, iron core-shell) The maximum rated voltage 300V AC rms Applicable standards Safety: EN61010-2-032:2002,300V CAT III, Contamination II EMC: EN61326:1997+A1:1998+A2:2001+A3:2003(Class A) Mechanical parameters Measurable conductor diameter Max.15mm Cable length About 3m Dimension (W x H x D) About 46135 21 (Excluding protruding parts) Weight About 230g Environmental conditions Operating temperature 0 to 50 C (32-122 F) Operating humidity 80%RH(No condensate) Storage temperature -10 to 60 C (14-140F) Storage humidity 80%RH(No condensate) Operating environment Indoor, altitude up to 2000 meters
FEATURES Suitable for 10A-200A cable online measurement. Holding wire diameter: 20mm Dimension: 52.5mm137.5mm28mm Load capacity: Installation: clamp type Output mode: lead output PARAMETERS Electrical parameters Ratio 1000: 1 or 2000:1 (customized) Accuracy class 0.1%, 0.2% Primary current 0 - 200A AC Secondary current 0 - 200mA AC (customized) Max. Cont. Input current 240A Load capacity 4 Over voltage category CAT III 600V Output signal (AC current) From 0 to 200mA AC at nominal input current Output signal (AC voltage) From 0 to 2V AC at nominal input current Frequency range 40Hz-2000Hz Dielectric strength 3KV 50Hz/60Hz at 1minute Temperature range -20C to +55C Output 2.5 meter cable with D01 connector Max. voltage not insulated conductors 600 V Standard EN 61010-1, EN 61010-2-032, IEC60044-1 Installation Clamp type Output mode Lead output(2.5m) Mechanical parameters Dimensions (L x W x H) (mm) 52.5 x 137.5 x 28 Weight (g) 400 Holding wire diameter (mm) 20 Max. jaw opening (mm) 20 Jaw color Red, yellow, blue, green, black Material PC+ABS+Polycarbonate, UL94 V0
FEATURES Suitable for 10A-200A cable online measurement. Holding wire diameter: 20mm Dimension: 52.5mm 137.5mm 28mm Load capacity: 4 Installation: clamp type Output mode: lead output PARAMETERS Electrical parameters Ratio 1000: 1 or 2000:1 (customized) Accuracy class 0.1%, 0.2% Primary current 0 - 200A AC Secondary current 0 - 200mA AC (customized) Max. Cont. Input current 240A Load capacity 4 Over voltage category CAT III 600V Output signal (AC current) From 0 to 200mA AC at nominal input current Output signal (AC voltage) From 0 to 2V AC at nominal input current Frequency range 40Hz-2000Hz Dielectric strength 3KV 50Hz/60Hz at 1minute Temperature range -20C to +55C Output 2.5 meter cable with D01 connector Max. voltage not insulated conductors 600 V Standard EN 61010-1, EN 61010-2-032, IEC60044-1 Installation Clamp type Output mode Lead output(2.5m) Mechanical parameters Dimensions (L x W x H) (mm) 52.5 x 137.5 x 28 Weight (g) 400 Holding wire diameter (mm) 20 Max. jaw opening (mm) 20 Jaw color Red, yellow, blue, green, black Material PC+ABS+Polycarbonate, UL94 V0
The Primary current sensor uses the same sensor technology as the original Rogowski coil. The True RMS inductive sensor does not use magnetic materials. The opening of the sensor is electronically closed and external currents are electronically rejected. The accuracy, external current reject, and range of currents measured by the patented amp sensor substantially exceed the performance of the best clamp-on sensors. The key feature of the unit is the ability to leave it deployed on the line to record readings every 15 minutes for 90+ days. It easily attaches to the line with a standard insulating bar. Once on the line, it immediately begins to collect and record the primary current on the line. The Primary current sensor is equipped with a 433M wireless port for communicating the recorded data into the userâ??s PC. The data is downloaded through GF2018S PC-Link Software, which allows the user to download, view and query the data stored on the Primary current recorder. The housing of the Primary current sensor is made of ABS+PC and is built to operate safely, even in severe utility environments. It is resistant to shock, waterproof and resistant to flame. It also operates within a wide temperature range. The Primary current recorder has a screw insulation bar of installation, which allows it to hang on the line securely in all weather conditions. PC-Link Software is a user-friendly software interface that allows the user to download, view, graph and export data from the Primary current recorder into Microsoft Excel. The data directly transfers from the Primary current recorder into Excel through an 433M Port. PARAMETERS Basic parametersã?? Recording ammeter kit 3 wireless current sensors (GF2018A, GF2018B, GF2018C) 433 HHT(handheld terminal) or 433M wireless data reader(GF2018R) PC-LinkSoftware software(GF2018S) Carrying case Data recording interval 1min, 5min, 10min,15min, 30min; Time can be set from 1 second to 60 minutes Communication distance(wireless) Max 100m Communication 433M, 868M or 915M (option) Installation Installation with electricity; Disassemble with electricity Battery 3.6 volt lithium battery,9000mAh; Battery can be replaced Software requirements PC-Linksoftware & microsoft Excel Processor 100 MHz or higher (200 MHz or higher recommended) RAM 32 MB, 64M recommended Drive space 15 MB to load software, 10 MB of operating Space Use of position Outdoor or indoor Electrical parameters Range of operation Voltage 69kV,35kV,20KV, 10kV, 6kV, 0.38kV Current 0 to 400A; 0 to 800A; 0 to 1500A; 0 to 3500A; Sensor opening Up to 3.3 cm Resolution Amps 1 to 99.9A 0.1A 100 to 300A 1A Amps accuracy ±1% of reading plus 2 counts Frequency 60Hz (57-63 Hz) or 50Hz (47-53 Hz) models available Mechanical parameters Weight (kg) 0.48 Carrying case(kg) 6.5 Environmental conditions Operating temperature -40C to 60C
Eddy current sensor 8 mm 310880-50-03-01 YOYIK is located in Deyang, Sichuan Province, China. It is a well-known equipment and parts manufacturer in the power industry, focusing on the supply of parts for steam turbines, generators and hydroelectric generator sets. The company adheres to the principle of "technological innovation, quality first", adopts advanced production equipment and strict quality control system to provide high-quality products that meet international standards to global customers. YOYIK not only provides products, but also provides professional and comprehensive solutions for industries such as power, metallurgy, and chemical industry, helping customers improve equipment performance and optimize operating costs. Yoyik can offer many spare parts for power plants as below: #DF-Eddy current sensor 8 mm 310880-50-03-01-DF different types of lvdt 4000TD low rpm tachometer HY-TACH Travel sensor 5000TDG-60-01 Steam turbine bolt electric heating rod ZJ-20-3R linear variable differential transformer lvdt ZDET700B lvdt precision DET250 Eddy Current Signal Converter CON011/913-040 mechanical seal 30SPEN Governor IPC Frequency Measuring Module IMFCS01 sensor to measure linear position 2000TDZ-A Sensor DF311180-50-05-02 Drain HP heater WSS-58/W Bolt electric heating rod ZJ-22-18 LVDT transmitter XCBSQ-02/500-02-12 LVDT Sensor TD-1G-150-15 Eddy Current Sensor PR6422/002-140 Relay for distribution network RMD/C-66H Bolt electric heating rod ZJ-22-1(R) speed mornitor ZKZ-2T Explosion-proof isolation switch P1-25/I2/SVB/HI11+ATEX-7.5KW/25A Pressure switch DPSN4KB25XFSP5 Rotation Speed Sensor ZS-03 L=100 POSITIONER VALVE V18345-1010521001 AC Current Transducer YPD-I-A2-P5-04-ZS Module ADAM-4017 CARD MKVIE I/O IS220PPROH1A thermocouple WPNK2-221 inductive linear sensor 2000TD 0-100 MM Vibration switch EM9210 THERMOCOUPLE TYPE E WREKG2-93WG/PD04-321-1 Intermediate relay UEG/A-4DPDT/125VAC linear position and displacement sensing ZDET250A Ignition gun EHE-20-B-1-18H-S Weighing Controller HF2105 Fan propeller TFE630C-115B6 KM11010087 Double armored thermocouple WRE2-631T Eddy current sensor 8 mm 310880-50-03-01 MY-DFYL-2024-11-6
dc current sensor relay LJB1 5A/10V 0.5 Since its establishment in 2004, YOYIK, as a comprehensive manufacturing and processing enterprise, has been deeply involved in multiple fields such as electricity, petroleum, and chemicals, and its products and services cover the world. The company not only independently produces key components of power stations, but also acts as an agent for well-known overseas brands to ensure that the quality is in line with international standards, and is committed to providing customers with one-stop equipment selection and after-sales support services. Yoyik can offer many spare parts for power plants as below: #DF-dc current sensor relay LJB1 5A/10V 0.5-DF speed sensor CS-1H-D-075-02-00 thermal resistance WZP-230 Soundwave sensor DZXL-IIIA displacement measurement instrument TDZ-1-200 HEAVY DUTY NEMA LIMIT SWITCH 9007C Digital display device MSC-02B magnetic pickup sensor generator SMCB-01-16L high voltage transmitter LJB1 5A/10V 0.5 SURFACE PT100 WZPK2-336 Hydroturbine Wheel Vane Feedback Sensor SWB-5 BENTLY Cable 330705-02-18-10-02-00 industrial dial thermometer WSS-461 0ï½?350â?? �?8�?150 M27�?2 high temperature inductive proximity sensor CON041/916-100 Speed sensor CS-1G-G-075-03-00 Valve positioner V18345-1010551001 Gap Sensor Power Supply GJCD-15 temperature shock glass WZPM2-002 eddy current type transducer TM0180-A08-B00-C09-D05 TSI Sensor 330103-00-05-10-02-00 Power unit DPC75DIAZ-HOIBQC Sensor DF310880-50-10-00 Pressure Switch 6L-EE5-N4-C2A-YY LVDT Sensor TDZ-1C-03 camera IST-M938SRZ Eddy Current Sensor PR6423/001-010 type c thermocouple wire TE-105 MAGNETIC CONTACTOR S-N125 Eddy Current Sensor PR6425/010-121 LVDT Sensor TD-1-0250-15-01 VACCUM CIRCUIT BREAKER ZN63-VS1-2000-40KA sensor K TE-111 REGULATOR AIR PRESSURE PROTECTIVE SHELTER WITHOUT BACKFLOW MECHANISM AW20-02-C Flame detection optical fiber LK-YD-S-122 good tachometer HZQW-03A LVDT transmitter XCBSQ-03/50-02-11 Pressure Switch 4NN-EE4-N4-C2A dc current sensor relay LJB1 5A/10V 0.5 MY-DFYL-2024-10-22
Eddy current sensor 8 mm 310880-50-03-01 As a provider of one-stop power station equipment solutions, YOYIK not only has a complete standard product line, but also provides customized design and production services according to the specific needs of customers. The company's products cover multiple industries such as electricity, metallurgy, chemical industry, mining, etc., meet the special requirements under different working conditions, and demonstrate the flexibility and professionalism of the company with customized services. Yoyik can offer many spare parts for power plants as below: #DF-Eddy current sensor 8 mm 310880-50-03-01-DF Furnace flame periscope tube FTV-QG Fire resistant fuel flow meter C156.73.41.01 magnetic pickup sensor price CS-1 G-065-06-01 absolute linear position sensor TD-1 Rectifier monitoring card A52 Slip Detection Device Switch DH-III LVDT Sensor K151.36.06.001 Eddy Current Signal Converter CON011 hall sensor linear position C9231129 Multifunction power meter PD194E-9F2 wide gap sensors GJCF-6A Conductivity online analyzer LEX2000 Controller RC861CZ094HSSYMD82 Motor protection circuit breaker PKZM0/PKZMC-1.6 voltage switching relay RUS-11BS/220V Signal modules â?? analog 6ES7231-4HF32-0XB0 Belt tearing controller THSL-L transducer for displacement measurement 4000TD magnetic limit switch sensor TM0180-A05-B05-C03-D05 Excitation card SWL-3 DB/X LSZDH HMX Displacement transmitter LTM-4-S3 Hydrogen leakage sensor NA1000D II LVDT Sensor TDZ-FRD-30S LVDT Sensor 7000TDGN-25-01 Eddy Current Sensor PR6424/004-110 Travel switch Z-15GW-22-B Water Analyzer Transmitter CM442-45T 8/0 LVDT transmitter XCBSQ-01/250-01-01 DC SIGNAL CONVERTER M5VF-AA-R Rotating speed probe WZ-GC GAUGE LVDT transmitter XCBSQ-02/500-01-12 Bolt electric heating rod ZJ-20-T5A Feedwater Pump Speed Probe CS-3F-M16X1-L70 Anti interference LVDT Sensor TD-1K-600-15 Sensor DF311180-90-09-01 Sensor DF310880-50-09-00 Eddy current sensor 8 mm 310880-50-03-01 MY-DFYL-2024-10-22
dc current sensor relay LJB1 5A/10V 0.5 Since its establishment in 2004, YOYIK, as a comprehensive manufacturing and processing enterprise, has been deeply involved in multiple fields such as electricity, petroleum, and chemicals, and its products and services cover the world. The company not only independently produces key components of power stations, but also acts as an agent for well-known overseas brands to ensure that the quality is in line with international standards, and is committed to providing customers with one-stop equipment selection and after-sales support services. Yoyik can offer many spare parts for power plants as below: #DF-dc current sensor relay LJB1 5A/10V 0.5-DF speed sensor CS-1H-D-075-02-00 thermal resistance WZP-230 Soundwave sensor DZXL-IIIA displacement measurement instrument TDZ-1-200 HEAVY DUTY NEMA LIMIT SWITCH 9007C Digital display device MSC-02B magnetic pickup sensor generator SMCB-01-16L high voltage transmitter LJB1 5A/10V 0.5 SURFACE PT100 WZPK2-336 Hydroturbine Wheel Vane Feedback Sensor SWB-5 BENTLY Cable 330705-02-18-10-02-00 industrial dial thermometer WSS-461 0ï½?350â?? �?8�?150 M27�?2 high temperature inductive proximity sensor CON041/916-100 Speed sensor CS-1G-G-075-03-00 Valve positioner V18345-1010551001 Gap Sensor Power Supply GJCD-15 temperature shock glass WZPM2-002 eddy current type transducer TM0180-A08-B00-C09-D05 TSI Sensor 330103-00-05-10-02-00 Power unit DPC75DIAZ-HOIBQC Sensor DF310880-50-10-00 Pressure Switch 6L-EE5-N4-C2A-YY LVDT Sensor TDZ-1C-03 camera IST-M938SRZ Eddy Current Sensor PR6423/001-010 type c thermocouple wire TE-105 MAGNETIC CONTACTOR S-N125 Eddy Current Sensor PR6425/010-121 LVDT Sensor TD-1-0250-15-01 VACCUM CIRCUIT BREAKER ZN63-VS1-2000-40KA sensor K TE-111 REGULATOR AIR PRESSURE PROTECTIVE SHELTER WITHOUT BACKFLOW MECHANISM AW20-02-C Flame detection optical fiber LK-YD-S-122 good tachometer HZQW-03A LVDT transmitter XCBSQ-03/50-02-11 Pressure Switch 4NN-EE4-N4-C2A dc current sensor relay LJB1 5A/10V 0.5 MY-DFYL-2024-10-11
Eddy current sensor 8 mm 310880-50-03-01 As a provider of one-stop power station equipment solutions, YOYIK not only has a complete standard product line, but also provides customized design and production services according to the specific needs of customers. The company's products cover multiple industries such as electricity, metallurgy, chemical industry, mining, etc., meet the special requirements under different working conditions, and demonstrate the flexibility and professionalism of the company with customized services. Yoyik can offer many spare parts for power plants as below: #DF-Eddy current sensor 8 mm 310880-50-03-01-DF Furnace flame periscope tube FTV-QG Fire resistant fuel flow meter C156.73.41.01 magnetic pickup sensor price CS-1 G-065-06-01 absolute linear position sensor TD-1 Rectifier monitoring card A52 Slip Detection Device Switch DH-III LVDT Sensor K151.36.06.001 Eddy Current Signal Converter CON011 hall sensor linear position C9231129 Multifunction power meter PD194E-9F2 wide gap sensors GJCF-6A Conductivity online analyzer LEX2000 Controller RC861CZ094HSSYMD82 Motor protection circuit breaker PKZM0/PKZMC-1.6 voltage switching relay RUS-11BS/220V Signal modules â?? analog 6ES7231-4HF32-0XB0 Belt tearing controller THSL-L transducer for displacement measurement 4000TD magnetic limit switch sensor TM0180-A05-B05-C03-D05 Excitation card SWL-3 DB/X LSZDH HMX Displacement transmitter LTM-4-S3 Hydrogen leakage sensor NA1000D II LVDT Sensor TDZ-FRD-30S LVDT Sensor 7000TDGN-25-01 Eddy Current Sensor PR6424/004-110 Travel switch Z-15GW-22-B Water Analyzer Transmitter CM442-45T 8/0 LVDT transmitter XCBSQ-01/250-01-01 DC SIGNAL CONVERTER M5VF-AA-R Rotating speed probe WZ-GC GAUGE LVDT transmitter XCBSQ-02/500-01-12 Bolt electric heating rod ZJ-20-T5A Feedwater Pump Speed Probe CS-3F-M16X1-L70 Anti interference LVDT Sensor TD-1K-600-15 Sensor DF311180-90-09-01 Sensor DF310880-50-09-00 Eddy current sensor 8 mm 310880-50-03-01 MY-DFYL-2024-10-11
Three phase current transformer Model: SCT2851A, SCT2851B, SCT2851C Input current: 60-630A Output current: 5A/ 1A Accuracy: 1.0/0.5
So-e2-960 Limiting current type sensor oxygen sensors When voltage is applied to a zirconia electrolyte cell, oxygen is pumped through the zirconia disc from the cathode side to the anode side because the carriers of the current flowing through the zirconia electrolyte are oxygen ions. By attaching a cap with a pinhole on the cathode side of the cell and by increasing the voltage over the cell the current shows saturation due to the rate limiting step in the transfer of oxygen to the cathode. This saturation current is called limiting current and is nearly proportional to the ambient oxygen concentration. Below the advantages of the oxygen sensor: Measuring range 1.00 to 96.0 vol.% oxygen High accuracy For many types a more or less linear characteristic Small temperature dependence of the sensor signal Low interference with other gases Long service life In many cases â??single point calibrationâ?? necessary only once Applications: Medical Laboratory Food industry Household/gastronomy Measuring technique Security technology/monitoring (electrical-) industry Characteristic data: Measuring gas: oxygen concentration Measuring medium: gaseous atmosphere Measuring principle: limiting current type sensor Measuring ranges: 1.00 - 96.0 vol.% o2 Response time (t90): 2 to 25 sec. (depends on: sensor type, gas flow, measuring chamber) Sensor voltage / heating voltage / power consumption / heater cold resistance Sensor voltage: 0, 7 to 1, 6 volt Heating voltage: 3.6 â?? 4.4 volts Power consumption: 1.3 to 1.8 watts (depends on application and packaging) Cold resistance: r( 25'c ) = 3.25 ohm â± 0.20 ohm Warm up time: min. 30 s -
DIT1000 high-precision digital current sensor products are a new generation of digital sensors developed and produced by Hangzhi. This product adopts brand-new software and hardware design, can measure single-phase AC and DC current and frequency at the same time. The high-precision digital current sensor provided by Hangzhi for the above equipment plays a key role in the measurement of current in its process control. The digitalized data output reduces the difficulty for customers to collect current signals and greatly reduced the cost of the customers.
DIT1000 high-precision digital current sensor products are a new generation of digital sensors developed and produced by Hangzhi. This product adopts brand-new software and hardware design, can measure single-phase AC and DC current and frequency at the same time. The high-precision digital current sensor provided by Hangzhi for the above equipment plays a key role in the measurement of current in its process control. The digitalized data output reduces the difficulty for customers to collect current signals and greatly reduced the cost of the customers.