Standard: IEC/EN60898-1 GB/T10963.1 Instantaneous trip type: B/C/D The number of poles: 1P/1P+N/2P/3P/3P+N/4P Rated short circuit breaking capacity (Icn): 10kA Rated working current (In): 1-63A Rated working voltage( Ue): AC 230/400V Rated operating frequency: 50/60Hz Rated insulation voltage (Ui): 500V Rated impulse withstand voltage (Uimp): 4kV Mechanical/electrical life: 10000/4000 Time
Standard: IEC/EN60898-1 GB/T10963.1 Instantaneous trip type: B/C/D The number of poles: 1P/1P+N/2P/3P/3P+N/4P Rated short circuit breaking capacity (Icn): 6kA Rated working current (In): 1-63A Rated working voltage (Ue): AC 230/400V Rated operating frequency: 50/60Hz Rated insulation voltage (Ui): 500V Rated impulse withstand voltage (Uimp): 4kV Mechanical/electrical life: 10000/4000 Times
Standard: IEC/EN60898-1 GB/T10963.1 Instantaneous trip type: B/C/D The number of poles: 1P/1P+N/2P/3P/3P+N/4P Rated short circuit breaking capacity (Icn): 6kA Rated working current (In): 1-63A Rated working voltage (Ue): AC 230/400V Rated operating frequency: 50/60Hz Rated insulation voltage (Ui): 500V Rated impulse withstand voltage (Uimp): 4kV Mechanical/electrical life: 10000/4000 Times
Standard: EC/EN60898-1 GB/T10963.1 Instantaneous trip type: B/C/D The number of poles: 1P/1P+N/2P/3P/3P+N/4P Rated short circuit breaking capacity (Icn): 4.5/6kA Rated working current: In 1-63A Rated working voltage (Ue): AC 230/400V Rated operating frequency: 50/60Hz Rated insulation voltage (Ui): 500V Rated impulse withstand voltage (Uimp): 4kV Mechanical/electrical life: 10000/4000 Times
Standard: IEC/EN60898-1 GB/T10963.1 Instantaneous trip type: B/C/D The number of poles: 1P/1P+N/2P/3P/3P+N/4P Rated short circuit breaking capacity( Icn): 10kA Rated working current (In): 1-63A Rated working voltage (Ue): AC 230/400V Rated operating frequency: 50/60Hz Rated insulation voltage (Ui): 500V Rated impulse withstand voltage (Uimp): 4kV Mechanical/electrical life: 10000/4000 Times
Standard: IEC/EN60898-1 GB/T10963.1 Instantaneous trip type: B/C/D The number of poles: 1P/1P+N/2P/3P/3P+N/4P Rated short circuit breaking capacity (Icn): 6kA Rated working current (In): 1-63A Rated working voltage (Ue) : AC 230/400V Rated operating frequency: 50/60Hz Rated insulation voltage (Ui): 500V Rated impulse withstand voltage (Uimp): 4kV Mechanical/electrical life: 10000/4000 Times
Standard: IEC/EN60898-1 GB/T10963.1 Instantaneous trip type: C/D The number of poles: 1P+N Rated short circuit breaking capacity: Icn 4.5kA Rated working current: In 6-40A Rated working voltage Ue : AC 230V Rated operating frequency : 50/60Hz Rated insulation voltage Ui: 500V Rated impulse withstand voltage Uimp: 4kV Mechanical/electrical life: 10000/4000 Times
We can supply c45n mcb dz47 mcb, dz47le, c60n mcb, c65n mcb, ic65n mcb, merlin gerin mcb, lg mcb, abb mcb, mem mcb, legrand mcb, lg mcb, nt-50 safety breaker, s101 screw mcb, e4cb mcb, 200b mcb 200bz mcb, l7 mcb, nc-100h mcb, my mcb mt mcb mu mcb, sx mcb, bh mcb, hydraulic magnetic miniature circuit breaker Cm1 mccb cdm1, dpx mccb, hhb mccb, 3vl siemens mccb, am7 mccb, ns mccb, ds mccb, ea mccb, sa mccb, ab mccb, hfd mccb, 3ve mpcb, 3vu cb, gv Mpcb isomax s molded case circuit breaker (abb mccb) , nf-cs mccb(mitsubishi mccb), dpx mccb(legrand mccb), ns mccb (merlin gerin mccb) etc. Moulded case circuit breaker 1. Product net weight: 128g/pole 2. Packing quantity& weight: 12 pole /box, 20 box/carton, 240 pole/carton . 3. N.W: 22.5 kg/carton 4. G.W:24kg/carton 5. Packing measurement: inner box 22.5¡Á9¡Á8 cm, carton 45¡Á23.5¡Á33.5 cm ( ie 0.036 cbm)
SH200 Miniature Circuit Breaker Resin Type, ,Sh200 Mcb
4p 1000V DC Solar Mini Circuit Breaker Description: PQB1Z-63 4P PV DC breaker supplementary protectors are designed to provide overcurrent protection within appliances or electrical equipment, where a branch circuit protaction is already providedd or not required. Devices are designed for direct current(DC) control circuit applications. Technical Parameter: Item DC MCB Code PQB1Z-63 Pole 1P 2P 3P 4P Voltage 250VDC 550VDC 800VDC 1000VDC Current 1A,3A,6A,10A,16A,20A,32A,40,50A,63A Standard IEC/EN60947 Breaking Capacity 6KA,10KA Characteristic Curve B,C,D Working Temperature "-5°"to +40° Protection Degree IP20 Electrical life More than 8000times Mechanical life More than 2000times Dimension(W)X(H)X(D) 18X80X71 36X80X71 54X80X71 72X80X71 Installation 35MM DIN RAIL Accessory YES Installation Altitude â?¤2000M
Ishcanto ixd47-63 series miniature circuit breaker is made of plastic shell, operating mechanism, contact arc system, tripping mechanisum and other components. The shell is made of high-strength special plastic, with strong impact capability and light wieght. Feature: short circuit protection Isolation function Overload protection Control
Miniature Circuit Breaker Automatic Assembly and inspecting line MCB Automatic Assembly and inspecting line Keyword: Miniature Circuit Breaker Automatic Assembly, Miniature Circuit Breaker, Automatic Assembly line, Assembly Machine, Assembly Production Line Product Introduction Basic operation process: ï?¼Loading by AGV robots, printing QR codes based on the product work order issued by the SAP system, and then separating the upper and lower shells. ï?¼Bottom coating of the upper shell: The installation of three components is completed through ten processes, and after each assembly is completed, there is a corresponding installation accuracy testing process to ensure that the assembly is completely qualified. ï?¼Installation of lower shell components, upper and lower shell assembly: A total of 25 processes are used to install 12 components. After each part is assembled, guide pins are used to ensure the upper and lower assembly. After the installation of internal components is completed, the product's on/off function is tested. After passing the test, rivets are installed, pressed again, and the screws are removed. All installations are checked, and after passing the test, they are transferred to the inspection station. ï?¼Unipolar products undergo instantaneous detection, delay detection, cooling tower and other unit inspections, and are then labeled with QR codes and covers before being transferred to the next workstation. ï?¼Multi pole products require 9 steps of multi pole assembly, and after assembly, a second delay is performed to verify the stability and reliability of the product ï?¼Finally, it is transferred to the automatic packaging unit through pressure resistance testing, transfer printing, laser labeling, and buckle installation. The specific parameters: (1) Equipment input voltage: 220V �± 10%, 50Hz; (2) The equipment has functions such as automatic shell loading, lid opening, assembly of arc extinguishing plates, magnetic guide plates, handle springs, base springs, positioning pins, handles, jump buckles, locks, coil components, iron core components, wiring columns, adjustment screws, arc extinguishing covers, CCD recognition, lid closing, identification of qualified and unqualified products, assembly of cutting processes, online detection, real-time monitoring, component life monitoring, data storage, MES system and ERP system networking, parameter arbitrary formula, smart energy analysis and energy-saving management system, intelligent equipment service big data cloud platform, etc. (3) Theoretical production effeciency: 2 seconds per unit; Daily production of approximately 14400 pieces/8 hours; (4) This device has the function of power-off to save data for 30 days, making it easy to manage production data; (5) This device adopts touch screen operation, has a computer communication interface, and printing function
MCB Three-Phase Switch Electrical Circuit Breaker 3PAir Switch 100A Overload Protection Please contact us for further information!
Household Mini Leakage Circuit Breaker 60amp 2P 50Hz/60HZ Overload Protection Please contact us for further information!
1P Miniature Electric DC Circuit Breaker 60A Single Phase Main Circuit Breaker Please contact us for further information!
SH201L min circuit breaker mcb switch is applicable to electric circuits with rated voltage 230/400V AC, frequency 50/60Hz and rated current up to 63Amp. The product provides protection against over-load and short circuit to electric circuits and equipment in household and commercial installation. MCB is also used as non-frequent changeover of electric circuits.
S201 solar DC mcb electrical circuit breaker , apply to rating current 63A or less, It is mainly used for the overloading and short circuit protection in DC distribution system equipment and electric equipment. It can be widely used in electric, post, traffic, mining enterprise and different kinds of fields.
C65 C60 mini circuit breaker AC MCB is used in lighting distribution system or motor distribution system for protection overload and short-circuit in the system. The product is neoteric in structure, light in weight, reliable and excellent in performance. It has high breaking capacity, can trip quickly, and its case and items are adopted by high fire-resistant and shockproof plastics. The product, with long life, is mainly used in AC 50Hz/60Hz single pole 230V or two, three, four poles 400V circuit for overload and short-circuit protection as well as for infrequent on-and-off switching electric equipment and lighting circuit in normal case. The products comply with IEC 60898.
C60 DPN mcb thermal magnetic circuit breaker is applicable to protect line conductor and overload,and short circuit of small sealed motors.It is mainly for protection of circuits with AC 220V and 50Hz/60Hz,and for unfrequent conversion under normal conditions as well.Its action can be up to two poles with its only one pole volume and be used as a leakage breaker by assembling with leakage.It is produced as per EN898-87,IEC947-2 standards.
Miniature circuit breakers protect installations against overload and short-circuit, warranting reliability and safety for operations. They have two different tripping mechanisms, the delayed thermal tripping mechanism for overload protection and the magnetic tripping mechanism for short circuit protection. ï?? Extra-wide and complete range of MCBs to cover most applications and markets ï?? Meeting worldwide standards ï?? Certificates, documentation, training or background information to support customers due to their daily work ï?? Space and time saving thanks to frame degree updates Main features MCB range offer the possibility to select among different characteristics (B, C, D), configurations (1P, 1P+N, 2P, 3P, 3P+N, 4P), breaking capacities (up to 15 kA) and rated currents (up to 125A). Compliance to the worldwide standards, IEC/EN 60898-1 IEC/EN 60947-2 IEC/EN 60947-3 IEC/EN 61009-1 GB10963.1 GB1096.1 GB14048.2 GB14048.3 GB16917.1 Allowing the use for residential, commercial and industrial applications 25 mm2 and 10 mm2 cylinder lift twin terminals for challenging industrial use. Cross Real contact position indication, directly connected to the moving contact, for more comfort and safety ï?? Environmental Ambient Air Temperature: Operation -5 ... +55°C Storage -40 ... +70 °C Resistance to Shock acc. to IEC 60068-2-27: 30g / 2 shocks / 13 ms Resistance to Vibrations acc. to IEC 60068-2-6: 5g, 20 cycles at 5 ... 150 ... 5 Hz Environmental Conditions: 28 cycles with 55 °C / 90-96 % and 25 °C / 95-100 % Technical Standards: IEC/EN 60898-1 Rated Current (In): 6A, 10A,16A, 20A, 25A, 32A, 40A, 50A, 63A, 80A, 125A Rated Operational Voltage: acc. to IEC 60898-1 230 V AC & 400V AC Rated Insulation Voltage (Ui): acc. to IEC/EN 60664-1 440 V Rated Frequency (f): 50 Hz 60 Hz Rated Ultimate Short-Circuit Breaking Capacity (Icu): (230V AC & 400V AC) 15 kA Rated Service Short-Circuit Breaking Capacity (Ics): (230V AC & 400V AC) 6 kA Instantaneous release: Type C: Lighting protection ; Type D: Motor protection