The design of a switch mode power transformer will differ depending upon the type of circuit used. There are many variations of switching mode power supplies, but they can be narrowed down to three basic circuit configurations (each also has a mirrored configuration); buck, boost, and fly back. Be aware that the name for the buck circuit varies from industry to industry and from person to person. It may also be referred to as an inverter, d.C. Converter, forward converter, feed forward, and others. There are also unipolar and bipolar (push-pull) versions. Features : * non-corrosive * light weight * long lasting * high performance * long performing life
Primary voltage: 230V Secondary voltage: 12V Secondary current: 42mA No-load voltage: 20.4V Ambient temperature: T 70/B Rated power: 0.5VA Dimensions (H): 19.8mm (maximum) Weight: 36g (approximately) With CE mark weight:36g height:19.8mm
Excellent Materials: 1.Oxygen-free copper lines of lower resistivity, which will become smoother and burr-free after series of additional surface treatment, so the load loss of our transformador is lower and the electric performance is better. 2.High-quality silicon-steel plates which are of lower unit loss, and the no-load of the transformadores is lower. 3.High-quality wooden laminating insulation pieces, which wonâ??t split or move even under the influence of short circuit. 4.Thoroughly filtrated transformadores oil containing less water, gas and impurities, which makes our transformador es work better. 5.High-quality rubber sealing material, which can prevent the transformadores form aging. url:http://www.ybtransformer.com
Product Description: 1.IEC ISO Certification. 2.Power Transformers . 3.Low noise, environmental protection. 4.Low no-load loss ,energy conservation. Product Description: 1.IEC ISO Certification. 2.Power Transformers . 3.Low noise, environmental protection. 4.Low no-load loss ,energy conservation.
Power Transformer (35kV) Oil-immersed Transformer Products structure and technical features The oil-immersed transformer produced by our factory have these advantages: low loss, low noise, high short circuit strength and good appearance. We company create these prefect products of that each parameter has reached to advanced level among domestic similar products by combining advanced manufacture equipments and technology. Structure features: Core and main body: it is used iron core cutting line ,all inclined ladder joints and improving flux trend to eliminate flux saturation phenomenon of iron core in joints . By doing these, it reduces the no-load loss, no-load current and noise of transformers. Adopting pulling-plank structure, in order to strengthen the ability of withstanding short-circuit, we put many nails around pressing planks and bracing plates are used as support between H.V and L.V yoke, make the iron core be a whole. The iron core sheet are coated by glue which are specialized for silicon steel , so that all silicon steels can be bonded together to make the iron core be  integral one, this effectively enhances mechanical strength and plays a positive role in the core anti-rust. The low part of the body and the oil tank are supported through bracing plates adopt" high intensity electric laminated" technology, to guarantee the low part of oil-immersed transformer's body safe and reliable. Coil: The high-voltage(HV) coil adopts an interleaved-continuous structure, The low-voltage(LV) coil adopts an interleaved-continuous or spiral structure, are independently provided with voltage-regulating winding to balance the ampere turn of each winding-up, effectively lower the mechanical force to minimal level. In the transformer winding, there is a zigzag oil guide structure so as to fully cool all areas inside the winding, lower the temperature rise of the winding and the hot points of the winding and prolong the service life of insulation. Oil tank: the tank's structure of oil-immersed transformer is bell jar type or suspended type, have a good looking and high mechanical strength. It adopts" flanged joint" technology in every key point (such as annular tubes, pressure valves, switches,etc.), which effectively avoid leaking oil. Technical Parameter and features Technical specification 1,voltage:35kV 2,voltage regulation: on load tap regulation ,off circuit tap regulation 3,capacity range:
Basic Info Model NO.: GWEFD12 EFD15 EFD20etc GWRM4, RM5, RM6, RM8etc Usage: Single-phase Transformer Frequency Characteristics: High Frequency Shape of Core: Etd,RM Brand: Grewin Type: High Frequency Transformer Coil Number: High Magnetic Flux and Low Loss Magnetic Materials Indicative Power Capacity: UL Insulation System for Class B (130), F (155), H Trademark: Grewin High Frequency Transformer Transport Package: Export Standard Carton with Strong Pallet Specification: VDE, CE Origin: Tianjin HS Code: 85043190 Product Description We have passed ISO9001:2015,CE,SGS approval and IEC report 1).Features: Has a strong anti-interference, distributed capacitance, impedance, attenuation of low transmission, firm structure,can fine-tune the inductance, etc., are widely used in fax machines, PBX. 2). Applicable frequency range: 20 to 100kHz : Operating frequency: higher than 200kHz High magnetic flux and low loss magnetic materials With low leakage inductance and high efficiency . 3).Applications: PCB circuits, computer, TV, monitor, scanner, duplicator, mobile adapters, printer and other equipments and instruments. UL insulation system for Class B (130), F (155), H (180) 4). Can make other customized Ferrite transformers: Power range: core type using N67 grade material 500: ETD54, ETD59 and E65 5)Advantage: 1.UL, CUL, CE, ISO9001:2015 2.We offer custom-made transformers, OEM and ODM are welcome 3.We deliver the quality you expect at consistently competitive prices 4.Transformer quality lifetime:10 Years. 5.Specialty Sales service:5 -10 Years 6.Transformers Test: 100% test before the shipment About us: 1). Tianjin Grewin Technology Co.,ltd. has always laying great emphasis on our core business philosophy "Quality and Honesty First ". Grewin Mission: Growing together side by side,Mutual success hand in hand. Production: Ferrite Core High Frequency Current Transformer 2).Terms of Shipment: Within 10 working days after received related prepayment or L/C. 3).Payment terms: (1). T/T 100% or 50% deposit by T/T in advance, balance amount to be paid 7 days before delivery. (2). By irrevocable L/C at sight, to be issued immediately against confirmed order. (3). Payment by T/T, if order amount is less than USD 20,000. 4).Flow chart of trading activities: NO Step Days need 1 Request for quotation 1 day 2 Making quotations 1 day 3 Offer and counter offer 3 days 4 Sending and receiving samples 3-10 days 5 Sample confirmation 3 days 6 Placing a firm order 1 day 7 Paying and receiving the down payment 1-4 day 8 Factory production & Quality inspection 15-20 days 9 Paying and receiving the balance 4 days 10 Delivery of goods 1 days
Send me blueprints or draws with dimensions information to quote Size: E128~196, R.Core, Adaptor, E114~24 Input/Output: Customer's requested specification
S(B)H15-M Series Sealed Amorphous Alloy Power Transformer,oil immersed transformer,oil immersed power transformer,oil distribution power transformer Oil Immersed Transformer The transformer is completely hermetical oil-immersed type. The principle is the same as the hermetical power transformer. The basic elements of the amorphous alloy is Iron, nickel, cobalt, boron and carbon etc. Product Description The transformer is completely hermetical oil-immersed type. The principle is the same as the hermetical power transformer. The basic elements of the amorphous alloy is Iron, nickel, cobalt, boron and carbon etc. It is a kind of isotropic soft magnetic material with low magnetizing power. With 0.027mm thickness and the filling coefficient is reduced to 0.75-0.8, the amorphous alloy material is very sensitive for stress. The electrical resistivity of the material is 3-6 times of silicon steel sheet and the hardness is 5 times of it. Load loss of S(B)H15-M 30ï½?1600/6ï½?10 series transformer can be reduced by 15% on the basis of GB/T6451 standard. The no-load loss can be reduced by 70% on the base of GB/T6451 standard. Amorphous alloy transformer meets the standard JB/T10318-2002 Technical parameter of oil immersed type amorphous alloy transformer. Model and Meaning Technical Parameter of S(B)H15-M Series Hermetical Amorphous Alloy Power Transformer Rated capacityï¼?kVAï¼? Voltage and tapping range Connection Group Symbol No-load Lossï¼?Wï¼? Load Loss ï¼?Wï¼?75 No-load current (%) Short-circuit impedanceï¼?%ï¼? High Voltage (KV) Tapping ranges of High Voltage Low Voltage (KV) 30 66.31010.511 ±5% ±2Ã?2.5% 0.4 Dyn11( or ) Yyn0 130 630/600 2.3 4.0 50 170 910/870 2.0 63 200 1090/1040 1.9 80 250 1310/1250 1.9 100 290 1580/1500 1.8 125 340 1890/1800 1.7 160 400 2310/2200 1.6 200 480 2730/2600 1.5 250 560 3200/3050 1.4 315 670 3830/3560 1.4 400 800 4520/4300 1.3 500 960 5410/5150 1.2 630 1200 6200 1.1 4.5 800 1400 7500 1.0 1000 1700 10300 1.0 1250 1950 12000 0.9 1600 2400 14500 0.8 2000 750 17400 0.20 5 We are pleased to deliver Transformer, Distribution Transformer, Power Transformer, Oil Transformer, Dry Type Transformer. Safe payment and on time deliver time will give you.If you want to know more about the product, please click here.
? Round shape with no air gaps ? Uniform primary and secondary windings locked in the magnetic field makes these transformers very quiet and efficient. ? Compact designing, efficiency, quiet and safer ? Smaller dimensions, lighter weight, and low stray magnetic fields We specialize in manufacturing of above products as per customer specifications. Carton in pallet
Toroidal magnetic cores are made of a Fe-based thin (20 microns) nanocrystalline ribbon and have low loss, high induction of saturation, high operating temperature (up to 150 C), high magnetic permeability. Magnetic cores have a negative temperature coefficient of losses that provides stabilization mode transformer temperature. Application in power high- frequency transformers push-pull,bicyclic SMPS, DC-DC converters, audiotransformers. High permeability provides good electromagnetic connection of windings and low leakage inductance values. HIGHLIGHTS OF THE MATERIAL: Induction amplitude, Bm (25 C) 1,2 T Induction amplitude, Bm (90 C) 1,1 T Curie temperature, Tc 570 C Magnetostriction less than 0,5 x10 ^ -6 Magnetic Permeability (100 kHz) - up to 20,000
Brief Description The insulation non-encapsulated dry-type power transformer is approved by America technology. With the advantages of safety, reliability, environmental friendliness, energy saving, fire and explosion protection, humidity and pollution resistance, strong overload capability, small volume and simple maintenance, and main performance indexes superior to domestic standards such as advanced design, reasonable structure and beautiful appearance, the product is a brand new transformer value-added scheme and is a new-generation energy-saving, safe, green and environmentally-friendly high-tech product!
1. Technical parameters. Toroidal Transformer I Power Thermal Fuse Current Fuse Dimension (mm) Approval Mark GWB25VA 135 ºC 250V 2A 250V T 2A 80*35 CE UL TUV CQC GWB30VA 135 ºC 250V 2A 250V T 2A 83*35 CE UL TUV CQC GWB40VA 135 ºC 250V 2A 250V T 2A 87*35 CE UL TUV CQC GWB50VA 135 ºC 250V 2A 250V T 2A 93*34 CE UL TUV CQC GWB60VA 135 ºC 250V 2A 250V T 2A 93*35 CE UL TUV CQC GWB80VA 135 ºC 250V 2A 250V T 2A 102*35 CE UL TUV CQC GWB105VA 135 ºC 250V 2A 250V T 2A 114*38 CE UL TUV CQC GWB120VA 135 ºC 250V 2A 250V T 2A 113*41 CE UL TUV CQC GWB140VA 135 ºC 250V 2A 250V T 2A 114*42 CE UL TUV CQC GWB150VA 135 ºC 250V 2A 250V T 2A 117*43 CE UL TUV CQC GWB160VA 135 ºC 250V 5A 250V T 5A 120*43 CE UL TUV CQC GWB180VA 135 ºC 250V 5A 250V T 5A 125*42 CE UL TUV CQC GWB200VA 135 ºC 250V 5A 250V T 5A 124*49 CE UL TUV CQC GWB220VA 135 ºC 250V 5A 250V T 5A 127*50 CE UL TUV CQC GWB240VA 135 ºC 250V 5A 250V T 5A 129*48 CE UL TUV CQC GWB250VA 135 ºC 250V 5A 250V T 5A 130*52 CE UL TUV CQC GWB260VA 135 ºC 250V 5A 250V T 5A 130*53 CE UL TUV CQC GWB280VA 135 ºC 250V 5A 250V T 5A 138*45 CE UL TUV CQC GWB300VA 135 ºC 250V 5A 250V T 10A 138*54 CE UL TUV CQC GWB320VA 135 ºC 250V 5A 250V T 10A 138*54 CE UL TUV CQC GWB340VA 135 ºC 250V 5A 250V T 10A 138*54 CE UL TUV CQC GWB360VA 135 ºC 250V 5A 250V T 10A 142*55 CE UL TUV CQC GWB380VA 135 ºC 250V 5A 250V T 10A 146*54 CE UL TUV CQC GWB400VA 135 ºC 250V 5A 250V T 10A 148*56 CE UL TUV CQC GWB420VA 135 ºC 250V 5A 250V T 10A 148*56 CE UL TUV CQC GWB440VA 135 ºC 250V 5A 250V T 10A 148*60 CE UL TUV CQC GWB460VA 135 ºC 250V 5A 250V T 10A 149*64 CE UL TUV CQC GWB480VA 135 ºC 250V 5A 250V T 10A 153*59 CE UL TUV CQC GWB500VA 135 ºC 250V 5A 250V T 10A 155*62 CE UL TUV CQC 2. We have attained VDE,UL,CE,ISO9000 approval .we guarantee quality is the first. Test process 1 .No-load test (included no-load voltage,no load current and no load loss) 2.iInductive voltage test 3. Load test (load voltage and temperature rise 4. Temperature rise test . 5.Insulated resistance 6.Hi-pot test 7.Leakage inductance test 8.DC resistance test 9.Surface inspection. 3.customized audio toroidal transformer and solar energy transformer Application: 220V 24V Toroidal Power Transformer 1). Application: 1. audio equipment 2. electric control 3. computer 4. solar device 5.telecommunications 6.high-end and middle-end vedio etc 2). Advantages: 1.High quality 100% copper core 2.a full range of toroidal transformer 3.Specially sales and technical services:5-10Years 4.With 14 years' producing history in transformer industry 5.our company have cooperated with many customers around the world and gained good reputation at home and abroad.
Execution standard GB 1094.1-2 power transformer general rules, power transformer temperature rise GB 1094.3 power transformer insulation level and insulation test GB 1094.5 "power transformer capacity to withstand short circuit" GB/T 6451 technical parameters and requirements of three-phase oil-immersed power transformer GB/T 15164 load guide for oil-immersed power transformer IEC76 power transformer GB 2536 "transformer oil" 800KVA~31500KVA three-phase double-winding non-excitation voltage regulating power transformer:
Performance parameters of S13 type 10kV double winding series: Type rated capacity (KVA) connection group label voltage combination (KV) no-load loss (W) load loss no-load current (%) short circuit resistance (%) High pressure range low Dy Yy. 10 10 Yyn0 / S13 - M - or Dyn11 10 6.3 6 + / - 5% Plus or minus 2 x 2.5% or + 3 x 2.5% -1 x 2.5% 0.4 40 360 340 2.8 4.0. S13-M-20, 70, 525, 500, 2.5. S13-M-30, 30, 80, 630, 600, 2.3. S13-m-5050 100 910 870 2.0. S13-m-63, 110, 1040, 1040, 1.9. S13-m-80 130 1310 1250 1.9. S13-m-100, 100, 150, 1580, 1580, 1580. S13-M-125, 125, 170, 1890, 1800, 1.7. S13-m-160, 200, 2310, 2200 1.6. S13-M-200, 240, 2730 2600 1.5. S13-m-250, 250, 290, 3,050, 1.4. S13-m-315 315340 3830 3650 1.4. S13-m-400, 4410, 452043001.3. S13-m-500, 480, 5410, 5150, 5150. S13-M-630 630 570 6200 6200 1.1. S13-m-800, 700, 7500, 7500, 1.0. S13-m-1000, 830, 10300 10300 1.0. S13-m-1250, 1250, 970, 12000, 0.9. S13-m-1600 1,170 14500 14500 0.8. S13-m-2000, 1510, 17800, 17800.0.8, 5.0. S13-M-2500, 1780 20700 20700 0.7. S13-m-3150 3150 2100 24300 24300 0.7.
1.Features, High permeability High saturation induction , low core loss The density and lamination coefficient of nano-crystalline is lower than that of Permalloy, under the condition of the same size and similar performance of the Two. It is 1/4 lighter in weight, and 1/3 lower in the manufacturing cost. Good temperature stability:work for a long time at temperature of -55 ~ 130 , The linear range of nano-crystalline alloy is wider than that of permalloy .
Toroid cores for switching power supply made of nanocrystalline are featured by its high magnetic permeability and low loss. It's the ideal material for many components in single-ended, push-pull or bridge type high frequency switching power supply, such as main transformer, magnetic amplifier, choking coil, stored inductance, filtering inductance, common mode choke and spike blocker. Application: Main transformer, pulse transformer, control transformer, etc in medium and small power switching power supply modules. Applicable in different kinds of work mode, like single-ended, bridge type, push-pull, etc. Properties: High magnetic permeability and low coercivity Low loss, low temperature rise A flexible selection of cores with different magnetic performances according to the work mode of switching power supply. Paper cnt
Specifications Application Industrial Use Condition New Frequency 50hz, 60hz Tensile Strength 0-25Mpa, 125-150Mpa, 175-200Mpa Features Easy To Install, Four Times Stronger, Superior Finish
Wind Power Generation Transformer New Energy Dedicated Transformer Product structure and features General introduction With the continuous growth of China's economy, the demand for electricity surged, energy has become the main contradiction. Because the traditional coal-fired and fuel power generation caused serious environmental pollution, so in order to be consistent with environmental protection requirements, wind power as a clean energy production that has been developed rapidly in our country , has become the main direction to solve the energy shortage. We company develop a series of wind power generation combination substation, which can change 690V voltage generated by wind power dynamotor to 35kVor 10kV voltage through rising and changing voltage, then send to gird system or users, finally finish the task of wind power generation. So, wind power generation combination substation is the best matching product of wind power generation system. Structure and performance features 1, structure features A, main body adopts the structure of common box transformer. Assemble high-voltage load switch, plug-in fuse, transformer body, off-circuit tap-switches and other H.V components in a sealed tank, transformer oil as insulating medium, its size is small and performance is excellent . B, Overall combination type wind power substation is composed of H.V chamber, L.V. chamber, oil tank and radiator. Install chip radiator on the side of oil tank, the chip radiator is combined by guide pipe and cooling fin which can better adapt to high-power transformerâ??s cooling requirements. In order to prevent vandalism, to these cooling fins with weak mechanical, we will use steel shield that be punched cooling holes to enhance the protection. By substation, rise the voltage of power generated through wind dynamotor and merge into grids.
PV Power Generation Transformer New Energy Dedicated Transformer Product Introduction In order to meet the needs of our national PV power generation, our company developed two series of PV power generation transformers on the base of wind power generation combination transformers. 1, ZG(F)SF11-Z.G-â?¡/35 series three-phase split type off-circuit voltage-change PV power combination transformer The structure of this series of products is same as that of wind power generation transformers, except that L.V. side winding, outlet method and electrical equipments adopt special structures. L.V side is equipped with double-split winding and two outlets which can be connected with two PV generators at the same time, meanwhile, equipped with essential protective electric elements. This series of products are with characteristics of good electrical performance, small size, light weight, reliable operation, easy to install, high cost-effective, etc. Features of productsâ?? structure a, design thought: adoptsâ?� two generators, one transformerâ?� program, means two PV generators combines with one transformer. L.V side is equipped with double-split winding ,two outlets and L.V electric system which can be connected with two PV generators at the same time. b, users can rise one transformerâ??s output capacity under the capacity of same generators, which can save usersâ?? investment and operational cost. c, materials of transformersâ?? casings can be chosen according to different environmental requirements: conventional composite panels, stainless steel composite panels, non-metallic fiberglass cement, etc. d, casing material has a good level of protection and corrosion resistance, which can effectively prevent wind, rain, snow and salt erosion e, H.V. electrical equipments have five protection functions: H.V. fuse of substations and overload switchgear carry out interactive protection, prevent transformers working under the condition of lacking phase; H.V use three-position load switch that can be checked and repaired safely under the state of grounding; H.V overload switch and grid door of transformer chamber adopt â?? electric locking, realize the protection function of automatic power-off when mistakenly open the grid door. f, transformer chamber adopts natural ventilation and automatic controlling forced cooling exhaust devices, has a exhaust system which can be controlled automatically with temperature change, can effectively control and low chamberâ??s temperature, meet the need of full overload operation. g, low voltage equips with 690V main circuit breakers, over-voltage protection equipments , and we can design complete automatic measurement and intelligent control systems.
Looking for PCB Mounted Power Transformer with customized values to your application? aiia Transformer, as an experienced transformer manufacturer, offers Encapsulated 50/60Hz low-frequency low voltage with different types applied to home appliances. All transformers are auto winded by machine in premium quality in our own factory, potted by UL certified resin and 100% tested before packing and delivery. Explore & find the right parameter for your needs.