Standard: IEC/EN60898-1 GB/T10963.1 Instantaneous trip type: B/C/D The number of poles: 1P/1P+N/2P/3P/3P+N/4P Rated short circuit breaking capacity( Icn): 10kA Rated working current (In): 1-63A Rated working voltage (Ue): AC 230/400V Rated operating frequency: 50/60Hz Rated insulation voltage (Ui): 500V Rated impulse withstand voltage (Uimp): 4kV Mechanical/electrical life: 10000/4000 Times
Standard: IEC/EN60898-1 GB/T10963.1 Instantaneous trip type: B/C/D The number of poles: 1P/1P+N/2P/3P/3P+N/4P Rated short circuit breaking capacity (Icn): 6kA Rated working current (In): 1-63A Rated working voltage (Ue) : AC 230/400V Rated operating frequency: 50/60Hz Rated insulation voltage (Ui): 500V Rated impulse withstand voltage (Uimp): 4kV Mechanical/electrical life: 10000/4000 Times
Mini circuit breaker, RCCB, ELCB, RCBO, RCD Mini current circuit breakers are used for protection against indirect touching of parts under voltage, for prevention of lasting voltage on earthed parts which should appear because of a defect in the electrical installation and for protection against direct contacts of parts under voltage in case of in
Specification: 1.Rate current:1-63a 2.Rtated voltage:ac230/400v 3.Pole no:1p/1p+n/2p/3p/3p+n/4p 4.Curve:b/c/d 5.Breaking capacity:4.5/6/10ka About the detailed product informations, please feel free to visit our website:www.Ru-lena.Com Standard export packing
Mini circuit breaker has novel structure , reliable performance, high breaking capacity, pleasing outlook and small size. Its case and items are adopted by high fireresistant and shockproof plastics, it mainly used in the building office, house and similar building for illuminating at ac 50hz(60 hz), rated voltage below 400v , rated current below 100 a, distribution circuit and equipment overload, short circuit protection .It can also be used for unfrequent switch over of the circuit under normal conditions .This product conforms to the requirement of iec 60898&gb 10963 standards. Miniature
Mini circuit breaker Mcbis used in lighting distribution system or motor distridution system for protectiong overload and short-circuit in the system.
DZ47-63 (C45) series Miniature Circuit breakers(MCBs) is used in lighting distribution system or motor distribution system for protecting overload and short -circuit in the system.The product is novel in structure, light in weight, reliable and excellent in performance. It has high breaking capacity, can trip quickly and it's installation uses with guide, it's case and items are adopted with high fire resistant and shock proof plastics. The product, with long life, is mainly used in AC 50 HZ/60 HZ. Specifications: 1.Rated volatge: 240V/415V AC 2. Rated current (C):1, 3, 5, 6,10, 15, 16,20, 25,32,40,50,60,63A (D): 1, 3, 5, 6,10, 15, 16,20, 25,32,40A 3. Electric endurance not lower than 6000 times 4. Mechnical endurance not lower than 2000 times. 5. Poles : 1, 2, 3, 4. Trademark: Meba Model: DZ47-63 carton
Mini circuit breaker Gkd-65 midget circuit breaker is mainly suitable for overload and short circuit of Distribute circuit and equipment within the circuit of ac50hz, rated voltage up to 400v, Current up to 63a. It can also be used for an unfrequent switchover of the circuit. Main technical parameter: 1. Feature of over current tripper 2. When the ambient temperature is 30¦--35¦, the over-current tripper feature should In line with the characteristic of table 1. 3. Breaking capacity: complies with standard of ie60898, gb10963 and gb 10000a.
Mini circuit breaker(dpn) Gkd-32 is mainly suitable for overload and short circuit protection Within the circuit of ac 50/60 hz, rated voltage of single pole 250v or down The item is the idealest distribution protective switch in the civil residence field At present. This product conforms to the requirement of iec60898 and gb10963 standard.
Bhd6 mini circuit breaker BH-D6 mini circuit breaker is mainly suitable for overload and short circuit protection. It can also be used for an unfrequently switchover of the circuit and illumination under normal conditions.
Mini circuit breaker (1)inb2 (dz47) high-breaking mini circuit breaker The product is mainly used in ac 50/60hz. Voltage up to 400v circuit for overload and short-circuit protection as well as for unfrequent on-and off switching electric equipment and lighting circuit in normal case. The items comply with iec 60898&gb 10963. Rated voltage: 230v, 230/400, 400 v Pole number: 1, 2 ; 1, 2 ; 2, 3, 4 Rated current: 6, 10, 16, 20, 25, 32, 40, 50, 63 a (2)inb1-63 mini circuit breaker The items comply with iec 60898&gb 10963. It is mainly used for overload and short circuit protection in the circuit of ac 50/60hz, rated voltage of single pole up to 230v, two, three or four pole up to 400v. It can also be used for infrequent switch over of the circuit and illumination under normal conditions. (3)inb2-32 mini circuit breaker The items are used in ac 50hz or 60hz, 230v single phase dwelling house circuit for overload and short-circuit protection. The nature wire and live wire can be cut off synchronously to protect the life and avoid the fire. The items comply with iec60898&gb10963. Connection: rigid conductor 16mm2 Flexible conductor 10mm2 Rated voltage: 230v Pole number: 1p+n Rated current: 6, 10, 16, 20, 25, 32 a Breaking capacity: 4500a (4)bh(dz12-63) series mini circuit breaker The items are used in ac circuits 50hz forprotection of overload, short circuit and for circuit change-over in lighting system. Pole number: 1p 2p 3p Rated current: 6, 10, 16, 20, 32, 40, 50, 63 a Rated voltage: ac 120/230, 230/400 v Zhejiang inte industrial electric co., ltd. Was founded in 1984 and is iso 9001: 2000 certified. We mainly manufacture circuit breaker, thermal protector, thermostat and counter etc. Electrical and electronic equipments. Some of our products have got ccc, ul, vde, ce, saso approval. Leave factory packing
Industrial electrical wires and cables, ups systems and ancillary, junction boxes, mccb, relays and various other electrical products and equipment..We believe in quality, cost effectiveness and timely service. we try to understand and do the best as per the client requirements.
Standard: IEC/EN60898-1 GB/T10963.1 Instantaneous trip type: Electronic /Electromagnetic The number of poles: 1P+N/3P+N Rated limit short circuit breaking capacity (Inc): 6kA Rated working current (In): 16-63A (can be extended to 125A) Rated working voltage (Ue): AC 230/400V Rated operating frequency: 50/60Hz Rated impulse withstand voltage (Uimp): 4kV Rated residual operating current : 10/30/100/300mA Mechanical/electrical life: 4000/4000 Times Type of residual current : A/AC
Standard: IEC/EN61008-1 GB/T16916.1 Release Type of Leakage Protection: Electronic /Electromagnetic The number of poles: 1P+N/3P+N Rated limit short circuit breaking capacity (Inc): 6kA Rated working current (In): 16-63A Rated working voltage (Ue): AC 230/400V Rated operating frequency: 50/60Hz Rated impulse withstand voltage (Uimp): 4kV Rated residual operating current : 10/30/100/300mA Mechanical/electrical life: 4000/4000 Times Type of residual current: A/AC
Standard: IEC/EN61008-1 GB/T16916.1 Release Type of Leakage Protection: Electronic /Electromagnetic The number of poles: 1P+N/3P+N Rated limit short circuit breaking capacity (Inc): 6kA Rated working current (In): 16-63A Rated working voltage (Ue): AC 230/400V Rated operating frequency: 50/60Hz Rated impulse withstand voltage (Uimp): 4kV Rated residual operating current : 10/30/100/300mA Mechanical/electrical life: 4000/4000 Times Type of residual current: A/AC
Standard: IEC/EN61009-1 GB/T16917.1 Instantaneous trip type: B/C/D The number of poles: 1P+N/3P+N Rated short circuit breaking capacity (Icn): 6kA Leakage protection trip type: Electronic Rated working current (In): 6-63A Rated working voltage (Ue): AC 230/400V Rated operating frequency: 50/60Hz Rated insulation voltage (Ui): 500V Rated residual operating current : 10/30/100/300mA Life: 4000 Times Type of residual current : A/AC
Standard: IEC/EN61008-1 GB/T16916.1 Release Type of Leakage Protection: Electronic /Electromagnetic The number of poles: 1P+N/3P+N Rated limit short circuit breaking capacity (Inc): 6kA Rated working current In: 16-63A (can be extended to 125A) Rated working voltage (Ue): AC 230/400V Rated operating frequency: 50/60Hz Rated impulse withstand voltage (Uimp): 4kV Rated residual operating current : 10/30/100/300mA Mechanical/electrical life: 4000/4000 Times Type of residual current: A/AC
Standard: IEC/EN61008-1 GB/T16916.1 Release Type of Leakage Protection: Electronic /Electromagnetic The number of poles: 1P+N/3P+N Rated limit short circuit breaking capacity (Inc): 6kA Rated working current (In): 16-63A Rated working voltage (Ue): AC 230/400V Rated operating frequency: 50/60Hz Rated impulse withstand voltage (Uimp): 4kV Rated residual operating current : 10/30/100/300mA Mechanical/electrical life: 4000/4000 Times Type of residual current: A/AC
TERASAKI TEMPOWER ACB TYPES: AT06, AT16, AT12, AT20, AT25, AT32, AT40. TERASAKI TEMPOWER ACB Type AGR-11B,21B,22B,31B Overcurrent Protective Device) Types: AR208S, AR212S, AR216S, AR220S, AR325S, AR332S, AR440S, AR440SB, AR212H AR216H, AR220H, AR316H, AR320H, AR325H, AR332H, AR420H, AR440H.
VACCUM CIRCUIT BREAKER ALL TYPE OF ABB VACCUM CIRCUIT BREAKER VD4 12.12.25 , VD4 12.12.40, VD4 07.12.25.... MANY MORE 11 KV , 33KV . VD4Medium voltage vacuum circuit-breaker12 kV - 1250...4000 A - 63 kA36/40.5 kV - 630...3150 A - 16...40 kAMedium Voltage Products The VD4 are a synthesis of the renownedtechnology in designing and constructing vacuuminterrupters embedded in resin poles, and ofexcellency in design, engineering and productionof medium voltage circuit-breakers.Embedding the interrupter in resin makes thecircuit-breaker poles particularly sturdy andprotects the interrupter against shocks, accumula-tion of dust and humidity.The vacuum interrupter houses the contacts andmakes up the interrupting chamber.