Diesel vehicle exhaust gas analyzer (can also be used in gasoline vehicle), belong to customized products, non standard. Increase the reverse blowing system and filtering, purifying device. Can be used for the detection and analysis of diesel oil as fuel of vehicle exhaust emissions group points. ã??Main technical parametersã?? exhaust gas analyzer measuring range COï¼?0ï½?10.0 10-2(%) CO2ï¼?0ï½?20.0 10-2(%) HCï¼?0ï½?9999 10-6(ppm) O2ï¼?0ï½?25.0 10-2(%) NOï¼?0ï½?5000 10-6(ppm) oil temperatureï¼?18ï½?150 speedï¼?100ï½?20000rpm resolving power COï¼?0.01% CO2ï¼?0.1% HCï¼?1ppmO2ï¼?0.01% NOï¼?1ppm oil temperatureï¼?0.1 speedï¼?1rpm Repetitive error â?¤±2% Zero drift COï¼?±0.06 10-2(%)/4h CO2ï¼?±0.5 10-2(%)/4h HCï¼?±30 10-6(ppm)/4h O2ï¼?±0.5 10-2(%)/4h NOï¼?±30 10-6(ppm)/4h Distance drift No more than shown value error allowed (4 hours) Indication error COï¼?±5%ï¼?absolute errorï¼?±0.03 10-2 ï¼? CO2ï¼?±5%ï¼?absolute errorï¼?±0.5 10-2ï¼? HCï¼?±5%ï¼?absolute errorï¼?±10 10-6 ï¼?±5%ï¼?absolute errorï¼?4001ï½?10000ppmï¼? O2ï¼?±5%ï¼?absolute errorï¼?±0.1 10-2ï¼? NOï¼?±4%ï¼?absolute errorï¼?±25 10-6ï¼? environment condition oil temperatureï¼?±2ï¼?relative errorï¼? speedï¼?±1.0%ï¼?relative errorï¼? temperatureï¼?0ï½?40 humidityï¼?â?¤80% atmospheric pressureï¼?60ï½?105KPa Power Supplyï¼?AC 220V±10%ï¼?50Hz±1Hz(Automobile power supply inverter) Preheating time 10min Weight Measurement unitï¼?10Kg vice machineï¼?3Kg Volume Measurement unitï¼?610 * 500 * 330mm Auxiliary machine:500 * 350 * 330mm Sampling method Exhaust gas: direct sampling, sampling tube length 5m, sampling probe length 900mm; Temperature: the temperature measuring head into the engine lubrication oil scale hole, insert the oil rod and the length of the same length, rubber stopper blocked, to prevent oil jet and wire length: 5m; Speed: the tachometer speed clip in high pressure flexible gasoline engine, can determine the speed of a gasoline engine. Display mode LCD large screen liquid crystal display major function 1)Meet GB18285-2005 national standard requirements, measurement of motor vehicle gasoline engine emissions of HC, CO, CO2, O2 and NO concentrations,Of HC, Co, CO2, the advanced NDIR regardless of light and infrared analysis technology (imported from movement detection equipment to meet the requirements of national standard OIMLR99 0 level precision, high precision, strong stability) and of O2 and no by the new electrochemical analysis technology for detection. 2)With idle speed, double idle test function; 3)Auto calculation shows that the excess air coefficient isï¼? 4)Equipped with RS-232C digital serial communication interface, convenient networkingï¼? 5)Matching speed and temperature measurement functionï¼?
3 Part diff HEMATOLOGY ANALYZER YJ-H7100 Automatic Hematology Analyzer is mainly designed to detect the parameters of the series of red blood cells and hemoglobin,platelet and leukocyte in the blood.It is a requisite vitro diagnostic equipment which is applied to quantitative analysis of blood cells in clinical and laboratory. Clinical Equipment Medical Blood Hematology Analyzer (YJ-H7100) Features 1. Easy to operate 2. Carry-over protection by automatic probe interior and exterior washing 3. Both whole blood and prediluted blood test modes are available 4. Automatic self-checking and warming function 5. Automatic standby function 6. Safe reagent without any harm to environment Technical parameters
3 Part diff HEMATOLOGY ANALYZER YJ-H7100 Automatic Hematology Analyzer is mainly designed to detect the parameters of the series of red blood cells and hemoglobin,platelet and leukocyte in the blood.It is a requisite vitro diagnostic equipment which is applied to quantitative analysis of blood cells in clinical and laboratory. Biological Diagnostics Medical Blood Hematology Analyzer (YJ-H7100) Features 1. Easy to operate 2. Carry-over protection by automatic probe interior and exterior washing 3. Both whole blood and prediluted blood test modes are available 4. Automatic self-checking and warming function 5. Automatic standby function 6. Safe reagent without any harm to environment Technical parameters
Features: 1.3-part blood cell counter 2.20 parameters + 3 histograms 3.2 counting channels 4.Up to 60 samples/hour 5.10.4â?³ large color LCD 6.Built-in printer, USB port 7.Stable, durable and economical Performance: High Stability & Accuracy Use the most advanced binuclear embedded digital circuit system, to make the analytical ability great and stable 2 counting channels of WBC and RBC, to make the test results more accurate and less cross- contamination Use CPLD technology in data processing, to avoid the interference of electromagnetic signals
Sample volume: venous mode: 9.6ul venous Capillary mode: 9.6ul capillary Prediluted mode: 20ul capillary Working mode: double counting pathway +independent hgb detection system Operation mode: color windows interface, figure button, mouse input Dimension of gem aperture: wbc: 100um rbc/plt: 80 um Throughput: more than 60 samples per hour, 24 hour running continuous auto stand-by Storage: up to 35000 sample results including histograms can be stored Display: large color lcd display with 10.4inch, resoluion:640¡¨¢480 dot Interface: 1parallel interface, 2usb interface, 2ps/2 interface, 2rs232 interfaces (with net), 1vga interface Report: built-in rapid thermal recorder, optional external printer, 8 report formats Structure: fan-door structure, flexible and easy to use Ambientoperating:temperature:0degree-40degree.Humidity:10%-90% Power supply: ac100-240v`~50/60hz
3/5 part differentiation, 19/20 parameters +3 histograms Double apertures for wbc and rbc/plt separately Whole blood and pre-diluted counting modes available for different patients' sample requirement 45/60 samples/hour throughput Optional barcode scanner, printer port and other enhanced functions. 14-25kg
Two counting mode: whole blood & prediluted Patented aperture technology: automatic clog-clearing with high pressure and lower rate of clog Storage capability of up to 16000 sample results with histograms Automatic diluting, lyzing, mixing, rinsing Built-in thermal printer Bar code scanner ( optional) Reagent alarm system ( optional) Net weight: 19kg Gross weight: 22kg
Features: 3-part differentiation 23 parameters+3 color histograms Double channel counter Up to 60 samples per hour Volume measurement by time, more  stable  andreliable 8.4 inches high resolution TFT, Windows interface all testing parameter displayed simultaneously Advanced Volve  long lifetime Large storage capacity: up to 10,000 samples Rs232 interface, PC connecting Specification: Principle Impedance for cell counting Cyanide-free method for HGB Parameters WBC, Neu#, Lym#, Mid#, Neu%,Lym%, Mid%, RBC, HGB, HCT, MCV, MCH, MCHC,RDW-SD, RDW-CV, PLT, MPV, PDW, PCT, P-LCR Histograms WBC, RBC, PLT histogram
Hematology Analyzer
Description CBC with 3-Part differentiation, 19 parameters + 3 histograms 8.4 inches touch screen Up to 60 tests per hour 9.7 µL venous blood/20 µL peripheral blood sampling volume for testing Storage report (with picture) >1000 cases, unlimited expansion with U disk Available U disk software upgrade Real-time display and detection of sample temperature Wide range power supply design AC100V-264V
This hematology auto stainer provides fast, easy and stable staining process for staining blood according to wright, wright-giemsa and may-grünward staining method by automated system control. This new innovated stainer features advanced functions and performances over manual staining or automated dip-type stainers, include simplicity and convenience. It can be provide safety and comfortable environment of test lab. Dimensions: 480 x 445 x 265 mm Cleanrance height(lid open): max.565 mm(open door) Weight: approx. 21kgs
25 parameters +3 histogram+1 3D scattergram 5 part blood cell counter 60 samples/hour 2 test mode 14'' large touch screen External USB printer Stableï¼?durable and economical Tri-angle Laser scatter 3D Scattergram analysis Flow Cytometry method Cyanide free reagent for HGB test Impedance method for RBC and PLT counting
Electrolyte analyzer, full-auto hematology analyzer, semi-auto biochemistryn analyzer, urine analyzer, coagulation analyzer.OEM
YJ-75 analyzer is a 5-part diff. multi-parameter automated hematology analyzer designed for clinical laboratories. The analyzer uses light scatter and impedance technology for WBC diff. and impedance method for RBC and PLT. With most updated technology and concept, it best meets most labs' needs. The equipment is of friendly software powerful function, stable part diff. and accurate results. Specification: Model YJ-H7501 YJ-H7502 YJ-H7503 Sampling Manual without pierce Manual with pierce Auto with pierce Auto loader None None Yes, 40samples/rack Barcode Optional on request Optional on request Yes Parameters 28 parameters + 3 histogram + 1 scattergram
Features : 1.Easy to operate 2.Carry-over protection by automatic probe interior and exterior washing 3.Both whole blood and prediluted blood test modes are available 4.Automatic self-checking and warming function 5.Automatic standby function 6.Safe reagent without any harm to environment
Sysmex 3-part XP 300 Differential Automated Hematology Analyzers Product Details: Automation Fully Automatic Instrument Name Haematology Analyzer Brand Sysmex Differential Type 3-Part Sample Volume Whole blood mode: 50 Microliter Parameters Whole blood mode: 8 parameters with 3-part Differential WBC; RBC; HGB; HCT; MCV; MCH; MCHC; PLT; Sysmex provides two 3-part WBC Differential automated hematology analyzers*. These systems are ideally suited for physician office laboratories, clinics and small hospitals that perform moderately complex testing. Built on reliable Sysmex technology, the 3-part differential analyzers feature simple operation, minimal maintenance and compact, space-saving designs. With its simplified operation, the XP-300 is ideal for clinics, satellite laboratories and research testing. The XP-300 provides a CBC with 8 parameters, including a 3-part WBC Differential with an absolute neutrophil count (ANC).
Type: Blood Analysis System Brand Name: OEM Model Number: MSLAB23 Place of Origin: China Instrument classification: Class II Warranty: 1 Year After-sale Service: Online technical support Product name: Hematology Analyzer Parameters: 25 Reportable parameters:WBC,RBC,HGB,HCT,MCV..... 3 histograms: WBC/BASO,RBC,PLT 4 Research parameter: ALY% ALY# IG% IG# Test model: Whole blood model;CBC model,CBC+5-Diff model Throughput: 60 tests/hour Sample Volume: CBC+5-Diff model:â?¤20ul;CBC MODEL: â?¤10ul Data Memory: UP to100,000 results Display: 14 inch touch screen,resolution 1366*768 Interface: 1 LAN port,4 USB ports
3-part blood cell counter 20 parameters + 3 histograms 2 counting channels Up to 60 samples/hour 10.4â?³ large color LCD Built-in printer, USB port Stable, durable and economical
Major Functions Developed with real Bio-Impedance-Analysis Technology for real measurement. Measure volume percentage of general water nutrition, and display it on a LCD screen. High precision measurement. Easy operation and auto- turn-off. Safety operation guaranteed. When not used for a long time, use alcohol to clean analyzer head before use. When used by other persons, always clean the analyzer head before use. An easy way to measure the absorption rate of cosmetics. Strong guidance on manual with detailed illustrations showing the normal reading ranges for several typical positions on our body for easy caring. Specifications READIBILITY : 0.1% TOLERANCE : ¤g1% WATER CONTENT MEASURMENT RANGE : 0 !V 99.9% POWER SUPPLY : 2 X AA OPERATING CURRENT : 2.5 mA NET WEIGHT : 58g SIZE : 170 X 30 X 24 mm (6.75 X 1.2 X 1.0 inch)
Hospital Laboratory product 5 part diff YJ-75 hematology analyzer Product description: YJ75 analyzer is a 5-part diff. multi-parameter automated hematology analyzer designed for clinical laboratories. The analyzer uses light scatter and impedance technology for WBC diff. and impedance method for RBC and PLT. With most updated technology and concept, it best meets most labs' needs. The equipment is of friendly software powerful function, stable part diff. and accurate results. Specification: Model YJ-H7501 YJ-H7502 YJ-H7503 Sampling Manual without pierce Manual with pierce Auto with pierce Auto loader None None Yes, 40samples/rack Barcode Optional on request Optional on request Yes Parameters 28 parameters + 3 histogram + 1 scattergram WBC; LYM#; LYM%; NEU#; NEU%; BAS#; BAS%; MON#; MON$; EOS#; EOS% RBC, HGB, HCT, MCV, MCH, RBC histogram, PLT histogram, Baso histogram and WBC differential scattergram