The RBBF Clamp-on Ultrasonic Flow Meter is a fixed-mount, low cost transit-time ultrasonic flow meter with clamp-on transducers for non-invasive liquid flow rate measurement. Our microprocessor-based, user friendly field programmable creates no interruption of the process flow and has low installation costs.
This versatile series of flow meters is available in a variety of configurations. Available transducer types include clamp-on, in-line, and insertion. Wall-mount, panel-mount, pipe-mounted and compact din-rail mounted display types are also offered. Additional available features include pulse, 0-20mA & 4-20mA outputs, RS-232 communication, user-selectable engineering units, and a data logger function.
Residential Diaphragm Gas Meter
ITRON (MID approved)
Steel Version
Basic Features
3 Compact size: 1.2 dm cyclic volume
Range: G1.6, G2.5, G4
EN 1359 & O.I.M.L compliance
Design
Long -term accuracy & safety
Ready for remote reading & data management
Quality
World-class, ISO9001 certified, European Engineering and
Manufacturing
APPLICATION
The ITRON, with an installed base of over 30 million units, is a
versatile meter that makes it the preferred choice of many large
utilities world-wide.
METROLOGY
The ITRON meets O.I.M.L, EN 1359 and MID (certificate delivered by
the LNE), and more than 25 national metrological standards
(DVGW,NMI Class 1....).
Its design and the careful choice of materials enable the ITRON to
meet the highest demand in international markets in terms of
accuracy and long-term stability.
During the preliminary test controls on the sonic nozzle test benches,
all meters are tested at Qmin, 0.2 Qmax and Qmax.
OPERATING PRINCIPLE
The ITRON is a positive displacement diaphragm gas meter with a
stand-alone twin chamber measuring unit.
The twin chambers are each fitted with a flexible and gas-tight
diaphragm which is moved by the differential between the inlet and
outlet pressure. The Gas enters one side of the diaphragm pan while
on the other side it comes out through a separate port on the valve.
When one side is full, the rotating mono-valve moves on to the next
position, allowing the gas to fill the empty side. A transmission gear
and a mechanical coupling or stuffing box transfer the reciprocating
motion to the mechanical retrofitable index. The measuring unit is
housed in a robust gas-tight casing.
CONSTRUCTION
With its casing in steel, high protection against corrosion is ensured
by 500 hours salt fog spray test resistant cataphoresis treatment. The
aluminum version can withstand up to 1000 hours salt fog spray test.
The extreme strength of the case joint is achieved by rolling the belt &
compressing the flanges into contact with a sealant applied between
the faces. This forms a joint which is both gas-tight and fire- resistant.
MEASURING UNIT
The achievement of the fixed stroke mechanism is the result of
precision and high quality automation, and eliminates the need for an
adjustable tangent. This confines all registration adjustments to the
accessible change wheels behind the index.
The long life synthetic diaphragms, coupled to the well-proven
movement design, combine to give excellent stability and accuracy
during the whole life of the metre.
All materials have been selected for their superior resistance to
chemicals and gas. The valve and the grid, thanks to a special
Bakelite formulation, enjoy high gliding properties and are protected
against premature wear.
Finally, a back-run stop prevents the metre from running backwards
in case of tampering.
INDEX
The metres are available with metric or cubic inch indexes. They
come with a permanent magnet for pulse generation and can be
retrofitted with a pulse transmitter. Ip54 and Ip67 versions are
available for specific environments.
QUALITY ASSURANCE
Quality assurance procedures- such as ISO 9001- and strict controls
throughout the manufacturing process ensure a very high quality
level.
APPLICATION
The ITRON, with an installed base of over 30 million units, is a
versatile meter that makes it the preferred choice of many large
utilities world-wide.
METROLOGY
The ITRON meets O.I.M.L, EN 1359 and MID (certificate delivered by
the LNE), and more than 25 national metrological standards
(DVGW,NMI Class 1....).
Its design and the careful choice of materials enable the ITRON to
meet the highest demand in international markets in terms of
accuracy and long-term stability.
During the preliminary test controls on the sonic nozzle test benches,
all meters are tested at Qmin, 0.2 Qmax and Qmax.
OPERATING PRINCIPLE
The ITRON is a positive displacement diaphragm gas meter with a
stand-alone twin chamber measuring unit.
The twin chambers are each fitted with a flexible and gas-tight
diaphragm which is moved by the differential between the inlet and
outlet pressure. The Gas enters one side of the diaphragm pan while
on the other side it comes out through a separate port on the valve.
When one side is full, the rotating mono-valve moves on to the next
position, allowing the gas to fill the empty side. A transmission gear
and a mechanical coupling or stuffing box transfer the reciprocating
motion to the mechanical retrofitable index. The measuring unit is
housed in a robust gas-tight casing.
CONSTRUCTION
With its casing in steel, high protection against corrosion is ensured
by 500 hours salt fog spray test resistant cataphoresis treatment. The
aluminum version can withstand up to 1000 hours salt fog spray test.
The extreme strength of the case joint is achieved by rolling the belt &
compressing the flanges into contact with a sealant applied between
the faces. This forms a joint which is both gas-tight and fire- resistant.
MEASURING UNIT
The achievement of the fixed stroke mechanism is the result of
precision and high quality automation, and eliminates the need for an
adjustable tangent. This confines all registration adjustments to the
accessible change wheels behind the index.
The long life synthetic diaphragms, coupled to the well-proven
movement design, combine to give excellent stability and accuracy
during the whole life of the metre.
All materials have been selected for their superior resistance to
chemicals and gas. The valve and the grid, thanks to a special
Bakelite formulation, enjoy high gliding properties and are protected
against premature wear.
Finally, a back-run stop prevents the metre from running backwards
in case of tampering.
INDEX
The metres are available with metric or cubic inch indexes. They
come with a permanent magnet for pulse generation and can be
retrofitted with a pulse transmitter. Ip54 and Ip67 versions are
available for specific environments.
QUALITY ASSURANCE
Quality assurance procedures- such as ISO 9001- and strict controls
throughout the manufacturing process ensure a very high quality
level.
Prepaid Gas Meter
Sensus Meters
satndars
33821 Huitong Flow Meter Suppliers
Short on time? Let Huitong Flow Meter sellers contact you.
Ginger root
Botanical name: Zingiber officinale Linn.
Family: Zingiberaceae.
Ginger oil and oleoresins are the volatile oil derived by steam distillation of ginger and oleoresin. It is obtained by percolating the powdered rhizomes of Ginger, Zingiber officinale with volatile solvents. Ginger contains 1-2 percent of volatile oil, 5-8 percent of pungent acrid oleoresin and starch. Zingiberene is the chief constituent in the oil of ginger. Oil is employed for flavoring all kinds of food products and confectionary and finds limited use in perfumery. Oleoresin, commercially called Gingerin contains pungent principles viz. gingerol and shogaol apart from the volatile oil of ginger and is used as an aromatic, carminative, stomachic and as a stimulant.
Oleoresin from ginger is obtained conventionally by extraction of dried powdered ginger with organic solvents like ethyl acetate, ethanol or acetone. Commercial dried ginger yields 3.5-10.0 per cent oleoresin. Ginger oleoresin is a dark brown viscous liquid responsible for the flavour and pungency of the spice.
Ginger of commerce or `Adrak` is the dried underground stem or rhizome of the plant, which constitutes one of the five most important major spices of India, standing third or fourth, competing with chillies, depending upon fluctuations in world market prices, world market demand and supply position.
Ginger, like cinnamon, clove and pepper, is one of the most important and oldest spices. It consists of the prepared and sun dried rhizomes known in trade as `hands` and `races` which are either with the outer brownish cortical layers (coated or unscraped), or with outer peel or coating partially or completely removed.
Ginger requires a warm and humid climate. It is cultivated from sea level to an altitude of 1500 meters, either under heavy rainfall conditions of 150 to 300 cm or under irrigation. The crop can thrive well in sandy or clayey loam or lateritic soils.
The composition of dry ginger is given below:
Dry Ginger rootMoisture:6.9 %
Protein:8.6 %
Fat:6.4 %
Fiber:5.9 %
Carbohydrates:66.5 %
Ash:5.7 %
Calcium:0.1 %
Phosphorous:.15 %
Iron:0.011 %
Sodium:0.03 %
Potassium:1.4 %
Vitamin A:175 I.U./100 g
Vitamin B1:0.05 mg/100 g
Vitamin B2:0.13 mg/100 g
Niacin:1.9 mg/100 g
Vitamin C:12.0 mg/100 g
Calorific value:380 calories/100 g.
Ginger Oleoresin is obtained by extraction of powdered dried ginger with suitable solvents like alcohol, acetone etc. Unlike volatile oil, it contains both the volatile oil and the non-volatile pungent principles for which ginger is so highly esteemed. Concentration of the acetone extract under vacuum and on complete removal of even traces of the solvent used, yields the so called oleoresin of ginger. Ginger oleoresin is manufactured on a commercial scale in India and abroad and is in great demand by the various food industries.
Circular steel pipe is both openings and have hollow concentric sections of steel larger than the surrounding. The specifications of steel pipes are indicated by appearance dimensions and inner diameter and wall thickness, with a wide range of dimensions from very small diameter capillary to large round steel pipe of several meters in diameter. Round steel pipes can be used for pipelines, thermal equipment, machinery industry, petroleum geological drilling, containers, chemical industry, and special uses. It can be divided into seamless, ERW, LSAW, SSAW steel pipe according to the production process.
â?¢ EMF-50-PFA-SS316L-MS-150-NO-1-0-0-1-220V
Accumax offers water metering solutions based on proven technology of Electromagnetic and represent the next generation of smart metering.Accumax delivers solutions in all shapes and sizes. From individual meters and remote reading systems to fully automated service solutions.The meter is true volume measuring meter. The measurement is independent of viscosity, Density, Dissolved/Undissolved solids, pressure or temperature of the flowing liquid as long as it maintains certain minimum conductivity. Various types of Liner & Electrode are used as per application requirements. Empty pipe detection is also provided.Accumax has in-house R&D centre & calibration setup as per industries standards.Principal of Operation:The Accumax Electromagnetic Flow-meter work on FARADAYs LAW OF ELECTROMAGNETIC INDUCTION. Hence the meter detects flow based on velocity of conductive liquid. Thus the meter are Calibrated in terms of volumetric flow rate from
Accumax offers water metering solutions based on proven technology of Electromagnetic and represent the next generation of smart metering.Accumax delivers solutions in all shapes and sizes. From individual meters and remote reading systems to fully automated service solutions.The meter is true volume measuring meter. The measurement is independent of viscosity, Density, Dissolved/Undissolved solids, pressure or temperature of the flowing liquid as long as it maintains certain minimum conductivity. Various types of Liner & Electrode are used as per application requirements. Empty pipe detection is also provided.Accumax has in-house R&D centre & calibration setup as per industries standards.Principal of Operation:The Accumax Electromagnetic Flow-meter work on FARADAYs LAW OF ELECTROMAGNETIC INDUCTION. Hence the meter detects flow based on velocity of conductive liquid. Thus the meter are Calibrated in terms of volumetric flow rate from it.Advantages:
Accumax offers water metering solutions based on proven technology of Electromagnetic and represent the next generation of smart metering.Accumax delivers solutions in all shapes and sizes. From individual meters and remote reading systems to fully automated service solutions.The meter is true volume measuring meter. The measurement is independent of viscosity, Density, Dissolved/Undissolved solids, pressure or temperature of the flowing liquid as long as it maintains certain minimum conductivity. Various types of Liner & Electrode are used as per application requirements. Empty pipe detection is also provided.Accumax has in-house R&D centre & calibration setup as per industries standards.Principal of Operation:The Accumax Electromagnetic Flow-meter work on FARADAYs LAW OF ELECTROMAGNETIC INDUCTION. Hence the meter detects flow based on velocity of conductive liquid. Thus the meter are Calibrated in terms of volumetric flow rate from it.Advantages:
Water Milk Analog Magnetic Flow Meter Price Electromagnetic Flowmeter
Wastewater Flow Meter, Mechanical Smart Electromagnetic Flowmeter
Quick Details:
Place of Origin Henan, China (Mainland) Brand Name WEILI Model Number MGG
Product Name MGG Medium Corrosive Accuracy 0.5%
Power supply 220VAC/ 24VDC Output 4-20mA /RS485 Application Measuring Liquids
Connection Thread Material Stainless Steel Type Integral
Product Description:
Magne W3000 PLUS Sanitary Centrifugal type Electromagnetic flowmeter adopting new sanitary centrifugal liner and technology ,which is in line with the food industry hygiene requirements , At the same time, its stainless steel shell connected with stainless steel clamp ,easy to remove and clean , so that the flowmeter can not easily be contaminated in using process and applied in food manufacture processing of Mineral water, soy sauce, jam, beer, fruit juice, rice, milk ,etc and Health and chemical industry .
Nominal Bore DN10ï½?DN300mm
Nominal Pressure 1.0ï½?4.0MPa
Accuracy ±0.5%ï¼?±0.3%
Flow range 0ï½?10m/s(Flow Velocity)
Liner materia PFA
Measuring Electrodes 316L Stainless steel , Harrington alloy B/C, Titanium , Tantalum
Shell material Stainless steel
Medium temperature Remote type-10 ~+160 ,Integral type -10 ï½? +80
Connection Mode ISO Standard Quick Connector
Main Features:
1) It adopting new sanitary centrifugal liner,that prevent the residue of measured media accumulated in the measuring pipe .
2) It used Fast Connection program and makes the demolition of the electromagnetic flowmeter, maintenance and cleaning to be facilitated.
3)It uses 16 digit embedded Super-Micro power consumption Microprocessor ,meanwhile adopts special technical designing excitation system of sensor ,having the functions such as higher integration ,fast in operational speed ,best accuracy in calculation ,digital signal processing ,strong capability of interference immunity ,stable and reliable measurement.
4)The flowmeter is a two-way measurement system with three totalizers: positive total, reverse total and total difference; can display positive and negative flow, and has multiple outputs: current, pulse, digital communication, HART protocol.
RS485 Pulse Output Signal Digital Flange Inline Type Ultrasonic Water Flow Meter
Newest Product TUF-2000F2
1. Protection Class: IP68
2. Pipe Size: DN15~DN6000
3. The main unit suits to install on the pipe, all parts achieve to IP68. Adapt to many severe working environment.
4. OEM supported.
Total Nitrogen: 46%+
Granulometry: ~ 2 - 3.35 mm
Specifications: Free flowing, and free of any foreign matters.
Origin: Egypt
Packing: 25-50 kg pp bags, or in pp jumbo bags of 625 kg
Inspection: SGS
Specifications:
Appearance white free-flowing fine granule
Granule size 90% min between 0.15-0.85mm
NaCl 99 % min
Moisture 0.09% max
Ca & Mg 0.3% max
Water insolubles 0.1% max