Transformers,Distribution and Power Transformer,Varivolt Safety Transformers Diesel Generators Industrial Panels Stabilizers Energy Saver Industrial Panels
Sc(b)h15 amorphous alloy dry-type distribution transformer Transformer can be installed indoors deep into the load center, so as to adapt to the need of high-density load of big modern cities. With the no-load loss reducing by 75% and the load loss reducing by 15% than that of gb/t10228 table 4 group i, the amorphous alloy distribution transformer is the state of the art energy efficient dry type transformer
Product Introduction Capacitive voltage transformer (CVT) in calibration the test must be conducted under the condition of 50Hz frequency complex geographical condition on site at the same time the traditional experiment device is difficult to meet the requirements of on-site handling testing series resonance booster device is first used in domestic field tunable resonance device has been widely used in domestic 500 kv and below the field calibration of capacitor voltage transformer. Product Parameters Technical parameters Rated Capacity 80kVA rated voltage 160kV Adjustable inductance range 65~130H Rated frequency 50Hz Rated current 0.5A Adjustable gap range 0~300mm
Sbh16-m.D amorphous alloy submersible transformer
Overview In the process of semi finished and finished production of power transformers, before the newly installed transformers are put into operation and according to the state Grid's preventive test rules, it is required to test the transformer's turn ratio or voltage ratio regularly.The traditional variable ratio bridge operation is tedious, the reading is not intuitive, and the necessary conversion, the test result is only one phase change ratio value.The transformer transformer ratio tester overcomes the shortcomings of the traditional transformer ratio bridge test, the screen uses a large screen high resolution LCD screen, convenient to use in the field, with Chinese menu prompt function, simple and intuitive operation, a complete three phase change ratio test, test speed, high accuracy. Technical parameter range 0.910000 The accuracy of reading 0.1 2 words or equal to 500 reading 0.2 2 words 500 3000 Reading 0.3 2 words 3000 The resolution of the 0.9 9.9999 0.0001 100 999.99 0.01 10000 and above 1 10 99.999 0.001 1000 9999.9 0.1 Working power supply AC220V 10 50Hz Instrument weight 3.5kg The use of temperature 10 50 Overall dimensions 260mm l 200mm W 160mmH Relative humidity 90 no dew Feature Full three phase sinusoidal inverter output, the output voltage is automatically adjusted, with soft start, soft stop function, so the test speed is fast, high precision Three-phase transformer, single-phase transformer, PT, Z type transformer ratio, group, polarity test function Blind test function, that is, variable ratio and group test when high and low pressure connection mode is not known; CT variable ratio polarity test function Angle difference test function for single-phase test Tap position can be tested up to 197
Product description Transformer Standard current transformer are also called precision current transformers, current transformer standards, standard CT and current transformer standards. Transformer standards are divided into current transformer standards and voltage transformer standards. Standard current transformers are used in the error test of transformers. Used as a current transformer calibration standard technical parameter 1. Temperature: 2. Relative humidity 3. Rated Primary Current:5-5000A 5A,1A 4.Rated secondary current:5 1A 5 Accuracy Class 0.05S 6. Allow long-term work under the rated current; More than120A across the core. Precautions: 1. The current of standard CT and tested CT must be the same in CT calibration. 2. Follow the given wiring diagram strictly. 3. Test whether the load box is accurate or not before calibrating the transformer. 4. Forbid secondary winding opening during the calibration. 5. Select demagnetization before calibration.The wiring diagram is shown in figure 5. Short out the secondary winding before cutting off the power when the demagnetization is finished. 6.Principle wiring diagram of CT with large current generator is similar to above diagram. They are the same except the output winding of large current generator and primary winding of transformer are the same one.
Product description Transformer Standard current transformer are also called precision current transformers, current transformer standards, standard CT and current transformer standards. Transformer standards are divided into current transformer standards and voltage transformer standards. Standard current transformers are used in the error test of transformers. Used as a current transformer calibration standard technical parameter Temperature -5 40 Relative humidity 80% Rated Primary Current 5-5000A 5A,1A Rated secondary current 5A 1A Accuracy Class 0.05S Allow long-term work under the rated current; More than120A across the core. Precautions The current of standard CT and tested CT must be the same in CT calibration. Follow the given wiring diagram strictly. Test whether the load box is accurate or not before calibrating the transformer. Forbid secondary winding opening during the calibration. Select demagnetization before calibration.The wiring diagram is shown in figure 5. Short out the secondary winding before cutting off the power when the demagnetization is finished. Principle wiring diagram of CT with large current generator is similar to above diagram. They are the same except the output winding of large current generator and primary winding of transformer are the same one.
High voltage transformer & core, their range is from 10kva to 35000kva.
Low voltage and high voltage instrument, transformers.Providing services and consultancy in area of high voltage and substation equipment condition assesment, diagnostics and life assesment of power transformer
Product Introduction The test system is mainly for power transformer distribution transformer no-load load characteristics; Dc resistance; Variable ratio group test also can be tested transformer power frequency withstand voltage test. At the same time external pick up ct interface is reserved for capacity increase. Transformer comprehensive test station measurement part is controlled by single chip microcomputer and testdata such as digital display no-load and short circuit are sampled synchronously by single chip microcomputer avoiding errors caused by manual calculation of voltage ammeter and power meter readings respectively in traditional test methods. product names Comprehensive test platform for transformer characteristics Transformer characteristic test station Transformer comprehensive test bed Transformer test station Transformer test bed Transformer comprehensive test station
TKBB-S Transformer Ratio Tester is specially designed for three- phase transformer in power system especially for transformer of type Z winding and other transformers whose zero-load current is relatively high.Transformer turns ratio test is very important in order to find out the transformer has the right ratio corresponding on its rated voltage in primary and secondary. TKBB-S is single phase, automatically test set specially designed for turns ratio, phase shift and excitation current measurements of power, distribution and instrument transformer. The tester has wide testing range fast testing speed favorable repeatability flexible data processing convenient connection complete protection easy learning and convenient operation.
The on-load tap changer is the only moving part connected with the transformer circuit so more and more attention has been paid to the detection of the on-load tap changer.In the electrical equipment handover and preventive test regulations it is required to check the action sequence of on-load tap changer measure switching time etc.This device is mainly used for measuring the transition waveform transition time transient resistance of transformer on-load tap changer three-phase synchronism etc.
Product description The test transformer calls the booster, it is the basic test equipment used by the power station, supplying and distributing the electrical power system and the scientific research unit. Which used in the insulated intension test on all kinds of electrical products, electrical equipments and insulated materials, testing the insulated level of products, discovering the insulated objection of quizzee, scaling the capacity burdened voltage Oil Immersed Testing Transformer 1 Technical index Model Capacity High Frequency Voltage Output Voltage High Frequency Voltage Output Current ) Low Frequency Voltage input Change Tempera- ture raised 30 minute V A 1.5 50 30 200 7.5 500 10 3 50 60 200 15 500 10 5 50 100 200 25 500 10 10 50 200 220/380 50/26 500 10
Product description The test transformer calls the booster, it is the basic test equipment used by the power station, supplying and distributing the electrical power system and the scientific research unit. Which used in the insulated intension test on all kinds of electrical products, electrical equipments and insulated materials, testing the insulated level of products, discovering the insulated objection of quizzee, scaling the capacity burdened voltage Oil Immersed Testing Transformer 1 Technical index Model Capacity High Frequency Voltage Output Voltage High Frequency Voltage Output Currentm) Low Frequency Voltage input Change Tempera- ture raised 30 minute V A YD G1.5 1.5 50 30 200 7.5 500 10 YD G 3 3 50 60 200 15 500 10 YD G 5 5 50 100 200 25 500 10 YD G10 10 50 200 220/380 50/26 500 10 YD G 20 20 50 400 380 53 500 10 YD G 30 30 50 600 380 79 500 10 YD G 40 40 50 800 380 105 500 10 YD G 50 50 50 1000 380 132 500 10
Product description This instrument absorbs the advanced technology of similar products at home and abroad, and can set up various parameters through the keyboard. This machine has a power down protection, over temperature protection, "0" C protection and gas protection, automatic electronic ignition, etc. it has the characteristics of stable and reliable performance, simple and reasonable structure, simple operation, high expansibility, etc. Technical index Temperature control: a. Chromatographic column chamber temperature a.1 Temperature control range: room temperature +8 400(Set the temperature increment 1) a.2 The precision of temperature control: It is±0.1, which is below 200;
Product description: standard current transformer is used as a standard for calibrating current transformers, Used as a standard to calibrate current transformer whose accuracy class is two or more lower than itself. The grounding pole of the machine shell must be grounded. To avoid electric shock, the conductor must be connected to the ground Technical index 1. Temperature: -5-40 2. Relative humidity: 80% 3. Allow long-term work under the rated current; More than 600A across the core. Feature; 1. The current of standard CT and tested CT must be the same in CT calibration. 2. Follow the given wiring diagram strictly. 3. Test whether the load box is accurate or not before calibrating the transformer. 4. Forbid secondary winding opening during the calibration. 5. Select demagnetization before calibration.Short out the secondary winding before cutting off the power when the demagnetization is finished. 6.Principle wiring diagram of CT with large current generator is similar to above diagram. They are the same except the output winding of large current generator and primary winding of transformer are the same one.
High-speed transformer verification device is a new generation of transformer verification device developed by our company. The design idea of virtual instrument is adopted. The user only needs to operate the virtual instrument interface on the computer screen through the mouse and keyboard to input the transformer type range accuracy level capacity power factor and other parameters can complete automatic testing of current transformers and voltage transformers as well as analysis calculation and database management of test results and can be printed according to user needs various records and certificates. 1. The automatic mutual-inductor calibration platform adopts a single chip microcomputer to realize the functions of measurement control and display. 2. With computer interface improve the level of office automation and reduce the labor intensity. 3. Can have a large screen display provide a friendly operation interface and rich measurement information. 4. It can automatically realize the measurement of the transformer and can automatically switch the current and voltage load box. 5. Possess good catching measures and be able to promptly inform users of wrong information. 6. This automatic transformer calibration station can reach level 2. 7. The transformation ratio of the standard transformer and the tested transformer does not have to be equal as long as the rated primary voltage or rated primary current of the standard transformer is greater than or equal to the rated value of the tested transformer it can be directly verified which is more convenient to use.
product features Product Characteristics 1 This Series Standard Current Transformer consists of primary winding Secondary winding composition 2 Check according to the standard current ratio indicated on nameplate This Series Standard Current Transformer can be used5/5or1/1The current is self-correcting 4 With casters for easy handling Product Parameter Product Parameters technical parameters service conditions temperature 5+40 humidity 80% The workplace should not have strong external electromagnetic fields unrelated to work Allow long service at rated current boundary dimension HL-22/23 370*170*440mm3 HL-32/33 330*190*430mm3 HL-53/62/63/(HL-62C/63C 470*230*570mm3 weight HL-22/23 13kg
product features Product Characteristics 1 This Series Standard Current Transformer consists of primary winding Secondary winding composition 2 Check according to the standard current ratio indicated on the nameplate 3 This Series Standard Current Transformer can be used5/5or1/1The current is self-correcting 4 With casters for easy handling Product Parameter Product Parameters technical parameters service conditions temperature 5+40 humidity 80% The workplace should not have strong external electromagnetic fields unrelated to work Allow long service at rated current boundary dimension HL-22/23 370*170*440mm3 HL-32/33 330*190*430mm3 HL-53/62/63 /(HL-62C/63C 470*230*570mm3 weight HL-22/23 13kg