EAP 150 Engine Model : 1106A-70TG1 Stand By kVA: 150 Stand By kW : 120 Prime kVA: 136 Prime kW : 110 Rated Current : 195 Engine heavy duty diesel engine - 12V starter and charge alternator - Replaceable air, fuel and oil filters - Mechanical governor control - Tropical type radiator - Flexible fuel hose - Oil drain valve and extension hose - Industrial type silencer and steel compensator - Maintenance-free starter battery - Water jacket heater - 1500 rpm engine speed Alternat - IP 21-23 Protection Standard - H Insulation Class - 50 Hz Frequency - 4 pole brushless synchronous type alternator - Automatic Voltage Regulator (AVR) - 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis - Convenient design for easy lifting and carrying - High standard sound proof canopy design - Modular design with easily removable nuts - bolts - Lockable doors - Transparent window for watching Control Panel - Electrostatic powder painted, providing protection against harsh weather conditions - Emergency STOP button - Fuel tank inside the chassis - Anti-vibration wedges (engine - chassis and chassis ground) Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system Engine Model 1106A-70TG1 Number of Cylinders 6 Inline Injection System Direct Compression Ratio 18,2 : 1 Bore 105 Strok 135 Displacement Lt 7,01 Air Intake Turbocharged Speed (RPM) 1500 Oil Capacity Lt 18 Standby Power kw / Hp 135,8 / 183,5 Prime Power Hp 122,7 / 166 Fuel Type Euro Diesel Governor System Mechanical Cooling System Water Cooling Coolant Capacity Lt 22 Fuel Consumption (lt / h) Lt Full Load 30,1 Lt %75 LOAD 21,9 Lt %50 LOAD 15,2 Frequency Hz Power kVA 150 Voltage V 230 / 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation Insulation Class H Protection Standard IP22-IP23 Power Factor 0,8 Weight (Silent) Kg 1890 Weight (Open) Kg 1650 Width (Silent) Mm 1000 Length (Silent) Mm 3150 Height (Silent) Mm 1700 Fuel Tank Capacity Lt 250 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isn t permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAP 110 Engine Model : 1104C-44TAG2 Stand By kVA: 110 Stand By kW : 88 Prime kVA: 100 Prime kW : 80 Rated Current : 144 Engine heavy duty diesel engine - 12V starter and charge alternator - Replaceable air, fuel and oil filters - Mechanical governor control - Tropical type radiator - Flexible fuel hose - Oil drain valve and extension hose - Industrial type silencer and steel compensator - Maintenance-free starter battery - Water jacket heater - 1500 rpm engine speed - IP 21-23 Protection Standard - H Insulation Class - 50 Hz Frequency - 4 pole brushless synchronous type alternator - Automatic Voltage Regulator (AVR) - 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis - Convenient design for easy lifting and carrying - High standard sound proof canopy design - Modular design with easily removable nuts - bolts - Lockable doors - Transparent window for watching Control Panel - Electrostatic powder painted, providing protection against harsh weather conditions - Emergency STOP button - Fuel tank inside the chassis - Anti-vibration wedges (engine - chassis and chassis ground) Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system Engine Engine Model 1104C-44TAG2 Number of Cylinders 4 Inline Injection System Direct Compression Ratio 18,2 : 1 Bore 105 Strok 127 Displacement Lt 4,4 Air Intake Turbocharged - Air to Air Cooled Speed (RPM) 1500 Oil Capacity Lt 8 Standby Power kw / Hp 80.7 / 109 Prime Power Hp 73.4 / 99 Fuel Type Euro Diesel Governor System Mechanical Cooling System Water Cooling Coolant Capacity Lt 13 Fuel Consumption (lt / h) Lt Full Load 22 Lt %75 LOAD 16,9 Lt %50 LOAD 11,1 Frequency Hz Power kVA 110 Voltage V 230 / 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation 1% Insulation Class H Protection Standard IP22-IP23 Power Factor 0,8 Weight (Silent) Kg 1480 Weight (Open) Kg 1290 Width (Silent) Mm 1000 Length (Silent) Mm 2800 Height (Silent) Mm 1500 Fuel Tank Capacity Lt 210 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isn t permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAP 70 Engine: PERK S Engine Model : 1104A-44TG1 Stand By kVA: 70 Stand By kW : 56 Prime kVA: 64 Prime kW : 51 Rated Current : 92 Engine heavy duty diesel engine 12V starter and charge alternator Replaceable air, fuel and oil filters Mechanical governor control Tropical type radiator Flexible fuel hose Oil drain valve and extension hose Industrial type silencer and steel compensator Maintenance-free starter battery Water jacket heater 1500 rpm engine speed Alternat IP 21-23 Protection Standard H Insulation Class 50 Hz Frequency 4 pole brushless synchronous type alternator Automatic Voltage Regulator (AVR) 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis Convenient design for easy lifting and carrying High standard sound proof canopy design Modular design with easily removable nuts - bolts Lockable doors Transparent window for watching Control Panel Electrostatic powder painted, providing protection against harsh weather conditions Emergency STOP button Fuel tank inside the chassis Anti-vibration wedges (engine - chassis and chassis ground) Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system Engine Engine Model 1104A-44TG1 Number of Cylinders 4 Inline Injection System Direct Compression Ratio 17.25 : 1 Bore 105 Strok 127 Displacement Lt 4,4 Air Intake Turbocharged - Air to Air Cooled Speed (RPM) 1500 Oil Capacity Lt 8 Standby Power kw / Hp 65,6 / 88,5 Prime Power Hp 59,6 / 80,5 Fuel Type Euro Diesel Governor System Mechanical Cooling System Water Cooling Coolant Capacity Lt 13 Fuel Consumption (lt / h) Lt Full Load 14,6 Lt %75 LOAD 11 Lt %50 LOAD 8 Frequency Hz Power kVA 79 Voltage V 230 / 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation 1% Insulation Class H Protection Standard IP22-IP23 Power Factor 0,8 Weight (Silent) Kg 1280 Weight (Open) Kg 1100 Width (Silent) Mm 1000 Length (Silent) Mm 2400 Height (Silent) Mm 1500 Fuel Tank Capacity Lt 180 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isn t permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
Diesel Generator Perkins Unused 1350 kva Silent type 50hz UK manufacturing The price for now: 80k
We are an independant supplier of european buit generators. Diesel machines from cummins perkins or mtu Alternators from leroy somer, mecc alte, stamford or marelli. We can provide open as well as containerized gensets.
Generators Manufacturer of genset from 10 kva to 2500 kva
Generating set 10 kva to 2500 kva, power plant, genset, generators.
Perkins engine 4008 2011 model coupled with leroy somer 1010 kva with auto syce panel
Botanical Name - Vitex negundo Category - Medicinal Form - Dry Part Used - Whole Plant General Information - Vitex negundo Linn., belonging to family Verbenaceae (which comprises 75 genera and nearly 2500 spe-cies), commonly known as Five leaved chaste tree (Eng), Nirgandi (Hindi), Nirgundi (San-skrit), is a deciduous shrub, occur in tropical to temperate region. The leaves have five leaflets in a palmately arrangement, which are lanceolate, 4 - 10 cm long, hairy beneathand pointed at both ends. The bluish purple flowers are numerous. The fruit is succulent, black and rounded when ripehaving about 4 mm in diameter. Vitex negundo (Linn.) is one of the common plants used in traditional medicine and reported to have variety of pharmacological activities. Although, all parts of V. negundo are used as medicine in theindigenous system of medicine, the leaves are the most potent for medicinal use. The decoction of leaves is used fortreatment of inflammation, eye-disease, toothache, leucoderma,enlargement of the spleen, ulcers, cancers, catarrhal fever,rheumatoid arthritis, gonorrhea, sinuses, scrofulous sores,bronchitis and as tonics, vermifuge, lactagogue, emmenag-ogue, antibacterial, antipyretic, antihistaminic, analgesic, in-secticidal, ovicidal, feeding deterrence, growth inhibition and morphogenetic agents. Phytochemicals - V. negundo have several types of compounds,such as volatile oils, lignans, flavonoids, iridoids, terpenes (triterpenes, diterpenes, sesquiterpenes), andsteroids.
Botanical Name - Pelargonium graveolens Category - Medicinal Form - Dry Part Used - Leaves General Information - "Commonly known as Geranium, Pelargonium graveolens, is an aromatic, perennial and flowering plant which belongs to Geraniaceae family in the order of Geraniales that contains about 230 genera and more than 2500 species4. Pelargonium species probably originates from South Africa and introduced to Europe in the 17th century and have since been hybridized all over the world5. Nowadays the major production of geranium takes place in China and Middle East especially in Egypt and Morocco6. Pelargonium genus has 750 species scattered widely around the world growing as annuals. P. graveolens has been known as â??Shamdani Atriâ?? in Iran. P. graveolens is a shrubby perennial plant growing to a height of 1 m if left unpruned. In the tropical areas it is grown as an annual. The leaves are lobed and contain essential oil. The plant has typical small, pink flowers. Leaves and stalks are the essential parts of this plant. The essential oil is extracted from fresh plant material mainly using steam distillation. P. graveolens essential oil is largely utilized in the perfumery, cosmetic and aromatherapy industries all over the world. It has since become indispensable aromatherapy oil. Geranium oil responds well to the balancing effects of constipation, insomnia, restlessness, nervousness, anxiety, worry, high blood pressure, anger, frustration, emotional upsets, hypercholesterolemia, slow to lose weight and low metabolic forces. " Phytochemicals - "Many chemical constituents such as volatile substances, terpenoids, flavonoids, phenolics, coumarins, cinnamic acids and tannins have been isolated from the plant. Citronellol (29.90%), trans-geraniol (18.03%), 10-epi-�³- eudesmol (8.27%), isomenthone (5.44%), linalool (5.13%), geranyl acetate (4.52%), �³- Cadinene (2.89%), geranyl butyrate (2.53%), geranyltiglate (2.50%) and gemacrene D (2.05%) were identified as the major constituents of the P. graveolens aerial parts essential oil. Phytochemical investigations in 1996 resulted in characterization of the indole alkaloids, elaeocarpidine, and its 20-H isomer epielaeocarpidine in the leaves of geranium. "
3.6Frequency50 hz 3.7Power factor0.8(lagging) 3.8Phase/wire3 phase 4 wires 3.9IsolationH Size: 1630*730*1250 Weight: 800kg
Technical data Genset model 30gf Filter, fuel filter, oil filter The components of the genset (1) diesel engine; (2)generator; (3)generator; (4)control panel(with 320b controller); (5)silent box The accessories Wave pipe , curved pipe , muffler , accumulator and the connecting lines , shock-absorbing spacer , and data . Size: 1760*730*1250 Weight:850kg
1.Main technical data of gensets 1.1ModelCcfj50jy 1.2Prime power50kw/63kva elf-exciting 3.5Prime voltage230v/400v 3.6Frequency50 hz 3.7Power factor0.8(lagging) 3.8Phase/wire3 phase 4 wires 3.9IsolationH Size:1850*730*1250 Weight:1000kg
1.Main technical data of genset 1.1ModelCcfj50j 2.2Model6bt5.9-gm83 2.3Prime power64kw 2.4Governor typeElectronic 2.5Configuration4 cycle , 6 cylinder in line 2.6Cooling methodBy heater exchanger 2.7Bore/stroke102¡¨¢120mm 2.8Displacement37.5 l 2.9Starting methodElectric 2.10Fuel consumption214g/kw.H 3. Main technical data of alternator Alternator is selected the new type brushless alternator designed by us marathon electric, which has a unique design, advanced structure, small size, light weight, excellent performance, reliable running and easy-to-use operation. 3.1BrandMarathon 3.2ModelMp-h-50-4 3.3Prime power50kw 3.4ConfigurationBrushless , self-exciting 3.5Prime voltage230v/400v 3.6Frequency50 hz 3.7Power factor0.8(lagging) 3.8Phase/wire3 phase 4 wires 3.9IsolationH Size: 1760*730*1250mm Weight: 900kg
Main technical data of industry gensets 1.1ModelJgc75gf 1.2Prime power75kw/94kva 1.3Prime voltage230/400v wer90kw/112.5kva 2.4Governor typeElectronic 2.5Configuration4 cycle , 6 cylinder in line 2.6Air intake systemNatural aspirate 2.7Bore/stroke102¡¨¢120mm 2.8Displacement5.9 l 2.9Starting methodElectric 2.10Compression ratio16.5:1 2.11Fuel consumption214g/kw.H 3. Main technical data of alternator Alternator is selected the new type brushless alternator designed by us marathon electric, which has a unique design, advanced structure, small size, light weight, excellent performance, reliable running and easy-to-use operation. 3.1BrandMarathon 3.2ModelMp-75-4 3.3Prime power75kw/93.75kva 3.4ConfigurationBrushless , self-exciting 3.5Prime voltage230v/400v 3.6Frequency50 hz 3.7Power factor0.8(lagging) 3.8Phase/wire3 phase 4 wires 3.9IsolationH Size: 2180*790*1300 Weight:1450kg
20KW/25KVA Cummins Silent Diesel Generator Set Cummins Series Generator/Generators/Diesel Generator/Diesel Generator Set/Silent Generator/Silent Diesel Generator/Genset Power From 20KVA up to 1500KVA, with compacted structure and best configuration. OEM CUMMINS Powered Diesel Generator Sets with its high reliability, low use and maintenance cost win the loyalty of many customers in the field of Army, transportation engineering system and mine industries. Established in 1919, headquartered in Columbus, Indiana, (USA) Cummins Inc. Serves customers in more than 160 countries and territories through its network of 680 Company-owned and independent distributor locations and more than 5, 000 dealer locations. As the largest foreign engine investors of China, Cummins possess Chongqing Cummins Engine Co., Ltd (produce M, N, K series engine) and Dongfeng Cummins Engine Co., Ltd (produce B, C, L series engine ) and produce CUMMINS engines with globally uniform quality standards. Control Systems Standard control panel is the basic configure for normally operation and usage. The advantages of this panel are easy operation, aomprehensive function and reliable protection and so on. There are indicating gauges, lamps, transfer switches and emergency stop button, etc. The control panel wil stop the whole generator set and alarm as well when malfunction appears. LED Automatic Control Panel is a kind of intelligent controller with LED displaying the operating mode of the controller and the running state of the generator sets. It can configure the control procedure and protection parameter of the generator set, and completely satisfied the automatic controlling requirement of the generator sets for the user or factory. LCD Automatic Control Panel is the configuration for nobody on duty controlling generator sets. This kind of panel adopts module control system, with large LCD screen to show the menu. The module can receive output signal from ATS and realize automatic start and stop the generator sets. 1, DCEC/CCEC Cummins Diesel Engines 2, Stamford / Leroy Somer / Marthon Alternators 3, CE Approved 4, One Year Warranty General Data Sheet Cummins Generators 50HZ Genset Model Standby / Prime Power Engine Model No. of Cylinder Displacement (L) Oil Capacity (L) Coolant Capacity (L) Genset Size (mm) Weight (KG) KVA KW Cummins L W H HF20C 30/25 24/20 4B3.9-G2 4 3.9 11 17 1470 650 1145 650 HF30C 40/37.5 32/30 4BT3.9-G2 4 3.9 11 17 1685 650 1145 700 HF40C 62/50 50/40 4BTA3.9-G2 4 3.9 11 18 1800 670 1190 830 HF50C 70/62.5 56/50 4BTA3.9-G3 4 3.9 11 18 1900 670 1190 850 HF64C 90/80 72/64 6BT5.9-G2 6 5.9 16 29 2100 790 1320 1050 HF80C 110/100 88/80 6BT5.9-G2 6 5.9 16 29 2100 790 1400 1080 HF90C 125/113 100/90 6BTA5.9-G2 6 5.9 16 29 2200 790 1450 1150 HF108C 150/135 120/108 6BTAA5.9-G2 6 5.9 16 29 2400 840 1450 1200 HF128C 175/160 140/128 6CTA8.3-G2 6 5.9 16 30 2480 860 1450 1400 HF144C 200/180 160/144 6CTA8.3-G2 6 8.3 24 35 2480 860 1460 1650 HF160C 220/200 176/160 6CTAA8.3-G2 6 8.3 24 39 2700 950 1460 1650 HF180C 250/225 200/180 6LTAA8.9-G2 6 8.9 24 47 2700 960 1500 1800 HF200C 275/250 220/200 6LTAA8.9-G2 6 8.9 24 47 2700 960 1500 1900 HF220C 300/275 240/220 6LTAA8.9-G3 6 8.9 24 47 2700 960 1500 2050 HF280C 375/330 300/264 QSM11-G2 6 11 38 62 3110 1200 1745 2880 HF320C 450/400 360/320 NTAA855-G7A 6 14 37 65 3300 1250 1720 3050 HF360C 500/450 400/360 KTA19-G3 6 19 50 99 3310 1290 1720 3100 HF420C 575/525 460/420 KTA19-G4 6 19 50 99 3600 1290 1900 3750 HF500C 688/625 550/500 KTAA19-G6A 6 19 50 195 3800 1500 1980 4500 HF620C 850/775 680/620 KTA38-G2 12 38 135 265 3860 1600 2195 6000 HF720C 1000/900 800/720 KTA38-G2A 12 38 135 303 3860 1600 2195 7000 HF820C 1125/1025 900/820 KTA38-G5 12 38 135 309 5300 1950 2500 8500 HF1020C 1400/1275 1120/1020 KTA50-G3 16 50 177 349 5300 2150 2520 9950 HF1200C 1675/1500 1340/1200 KTA50-G8 16 50 204 349 5300 2200 2550 10500
24KW/30KVA Cummins Diesel Generator Set Cummins Series Generator/Generators/Diesel Generator/Diesel Generator Set/Silent Generator/Silent Diesel Generator/Genset Power From 20KVA up to 1500KVA, with compacted structure and best configuration. OEM CUMMINS Powered Diesel Generator Sets with its high reliability, low use and maintenance cost win the loyalty of many customers in the field of Army, transportation engineering system and mine industries. Established in 1919, headquartered in Columbus, Indiana, (USA) Cummins Inc. Serves customers in more than 160 countries and territories through its network of 680 Company-owned and independent distributor locations and more than 5, 000 dealer locations. As the largest foreign engine investors of China, Cummins possess Chongqing Cummins Engine Co., Ltd (produce M, N, K series engine) and Dongfeng Cummins Engine Co., Ltd (produce B, C, L series engine ) and produce CUMMINS engines with globally uniform quality standards. Control Systems Standard control panel is the basic configure for normally operation and usage. The advantages of this panel are easy operation, aomprehensive function and reliable protection and so on. There are indicating gauges, lamps, transfer switches and emergency stop button, etc. The control panel wil stop the whole generator set and alarm as well when malfunction appears. LED Automatic Control Panel is a kind of intelligent controller with LED displaying the operating mode of the controller and the running state of the generator sets. It can configure the control procedure and protection parameter of the generator set, and completely satisfied the automatic controlling requirement of the generator sets for the user or factory. LCD Automatic Control Panel is the configuration for nobody on duty controlling generator sets. This kind of panel adopts module control system, with large LCD screen to show the menu. The module can receive output signal from ATS and realize automatic start and stop the generator sets. 1, DCEC/CCEC Cummins Diesel Engines 2, Stamford / Leroy Somer / Marthon Alternators 3, CE Approved 4, One Year Warranty. Iron Bracket.
32KW/40KVA Cummins Generator Set Cummins Series Generator/Generators/Diesel Generator/Diesel Generator Set/Silent Generator/Silent Diesel Generator/Genset Power From 20KVA up to 1500KVA, with compacted structure and best configuration. OEM CUMMINS Powered Diesel Generator Sets with its high reliability, low use and maintenance cost win the loyalty of many customers in the field of Army, transportation engineering system and mine industries. Established in 1919, headquartered in Columbus, Indiana, (USA) Cummins Inc. Serves customers in more than 160 countries and territories through its network of 680 Company-owned and independent distributor locations and more than 5, 000 dealer locations. As the largest foreign engine investors of China, Cummins possess Chongqing Cummins Engine Co., Ltd (produce M, N, K series engine) and Dongfeng Cummins Engine Co., Ltd (produce B, C, L series engine ) and produce CUMMINS engines with globally uniform quality standards. Control Systems Standard control panel is the basic configure for normally operation and usage. The advantages of this panel are easy operation, aomprehensive function and reliable protection and so on. There are indicating gauges, lamps, transfer switches and emergency stop button, etc. The control panel wil stop the whole generator set and alarm as well when malfunction appears. LED Automatic Control Panel is a kind of intelligent controller with LED displaying the operating mode of the controller and the running state of the generator sets. It can configure the control procedure and protection parameter of the generator set, and completely satisfied the automatic controlling requirement of the generator sets for the user or factory. LCD Automatic Control Panel is the configuration for nobody on duty controlling generator sets. This kind of panel adopts module control system, with large LCD screen to show the menu. The module can receive output signal from ATS and realize automatic start and stop the generator sets. 1, DCEC/CCEC Cummins Diesel Engines 2, Stamford / Leroy Somer / Marthon Alternators 3, CE Approved 4, One Year Warranty. Iron bracket.
40KW/50KVA Cummins Diesel Generating Set Cummins Series Generator/Generators/Diesel Generator/Diesel Generator Set/Silent Generator/Silent Diesel Generator/Genset Power From 20KVA up to 1500KVA, with compacted structure and best configuration. OEM CUMMINS Powered Diesel Generator Sets with its high reliability, low use and maintenance cost win the loyalty of many customers in the field of Army, transportation engineering system and mine industries. Established in 1919, headquartered in Columbus, Indiana, (USA) Cummins Inc. Serves customers in more than 160 countries and territories through its network of 680 Company-owned and independent distributor locations and more than 5, 000 dealer locations. As the largest foreign engine investors of China, Cummins possess Chongqing Cummins Engine Co., Ltd (produce M, N, K series engine) and Dongfeng Cummins Engine Co., Ltd (produce B, C, L series engine ) and produce CUMMINS engines with globally uniform quality standards. Control Systems Standard control panel is the basic configure for normally operation and usage. The advantages of this panel are easy operation, aomprehensive function and reliable protection and so on. There are indicating gauges, lamps, transfer switches and emergency stop button, etc. The control panel wil stop the whole generator set and alarm as well when malfunction appears. LED Automatic Control Panel is a kind of intelligent controller with LED displaying the operating mode of the controller and the running state of the generator sets. It can configure the control procedure and protection parameter of the generator set, and completely satisfied the automatic controlling requirement of the generator sets for the user or factory. LCD Automatic Control Panel is the configuration for nobody on duty controlling generator sets. This kind of panel adopts module control system, with large LCD screen to show the menu. The module can receive output signal from ATS and realize automatic start and stop the generator sets. 1, DCEC/CCEC Cummins Diesel Engines 2, Stamford / Leroy Somer / Marthon Alternators 3, CE Approved 4, One Year Warranty . Iron bracket.
64KW/80KVA Silent Diesel Generator Cummins Series Generator/Generators/Diesel Generator/Diesel Generator Set/Silent Generator/Silent Diesel Generator/Genset Power From 20KVA up to 1500KVA, with compacted structure and best configuration. OEM CUMMINS Powered Diesel Generator Sets with its high reliability, low use and maintenance cost win the loyalty of many customers in the field of Army, transportation engineering system and mine industries. Established in 1919, headquartered in Columbus, Indiana, (USA) Cummins Inc. Serves customers in more than 160 countries and territories through its network of 680 Company-owned and independent distributor locations and more than 5, 000 dealer locations. As the largest foreign engine investors of China, Cummins possess Chongqing Cummins Engine Co., Ltd (produce M, N, K series engine) and Dongfeng Cummins Engine Co., Ltd (produce B, C, L series engine ) and produce CUMMINS engines with globally uniform quality standards. Control Systems Standard control panel is the basic configure for normally operation and usage. The advantages of this panel are easy operation, aomprehensive function and reliable protection and so on. There are indicating gauges, lamps, transfer switches and emergency stop button, etc. The control panel wil stop the whole generator set and alarm as well when malfunction appears. LED Automatic Control Panel is a kind of intelligent controller with LED displaying the operating mode of the controller and the running state of the generator sets. It can configure the control procedure and protection parameter of the generator set, and completely satisfied the automatic controlling requirement of the generator sets for the user or factory. LCD Automatic Control Panel is the configuration for nobody on duty controlling generator sets. This kind of panel adopts module control system, with large LCD screen to show the menu. The module can receive output signal from ATS and realize automatic start and stop the generator sets. 1, DCEC/CCEC Cummins Diesel Engines 2, Stamford / Leroy Somer / Marthon Alternators 3, CE Approved 4, One Year Warranty. Iron bracket.