1.Product Profile QAM8300-1M power quality analyzer is an integrated monitoring, analyzing and controlling device that offers electrical parameter metering, harmonics metering and analysis, waveform sampling, measurement of Voltage swell, dip, interrupt, Voltage unbalanced ratio, fault record, event record, data record. QAM8300-1M can monitor and detect if the power quality fulfills IEC and EN standard. With its powerful I/O functions with exterior device, QAM8300-1M can perform harmonic control, PF adjustment, and demand monitoring functions. QAM8300-1M fulfils all the important requirements of IEC 61000-4-30 Class A standard. QAM8300-1M can work with our power quality monitoring and management software to provide energy management solutions for enterprises. With its strong networking capability, QAM8300-1M can display and record all the data records on the interactive trend chart. A data report can be formed periodically. The report can be used for fault analysis, statistics, real time monitoring purpose. QAM8300-1M fulfills IEC61000-4-30 A: 2003,IEC61000-4-15:2003,IEC61000-4-7:2002,EN50160,2004 etc standards. 2.Measurement Accuracy U, I: 0.1% U, I peak value, peak factor, flicker: 0.5% 3 phase Voltage unbalanced ratio: 0.2% 3 phase Current unbalanced ratio: 0.5% Frequency: 0 .002Hz Power factor: 0 .002 Power: 0.2% Energy: Active energy 0.2% IEC60687:1992(GB/T17883-1999) Reactive energy 0.2% IEC61268(1995) (GB/T17882-1999) Harmonics: IEC61000-4-30 class A Interharmonics: IEC 61000-4-30 class A Harmonic distortion rate: 2.5% 3.EMC and safety test EN61326-1 EN61000-4-2/3/4/5/12 IEC/EN61010-2001.
Gas analyzer, opacity meter.
Energy management system Factory automation Intelligent power panel Industrial automation Power Grid automation Community power monitoring Intelligent green building
Diesel vehicle exhaust gas analyzer (can also be used in gasoline vehicle), belong to customized products, non standard. Increase the reverse blowing system and filtering, purifying device. Can be used for the detection and analysis of diesel oil as fuel of vehicle exhaust emissions group points. ã??Main technical parametersã?? exhaust gas analyzer measuring range COï¼?0ï½?10.0 10-2(%) CO2ï¼?0ï½?20.0 10-2(%) HCï¼?0ï½?9999 10-6(ppm) O2ï¼?0ï½?25.0 10-2(%) NOï¼?0ï½?5000 10-6(ppm) oil temperatureï¼?18ï½?150 speedï¼?100ï½?20000rpm resolving power COï¼?0.01% CO2ï¼?0.1% HCï¼?1ppmO2ï¼?0.01% NOï¼?1ppm oil temperatureï¼?0.1 speedï¼?1rpm Repetitive error â?¤±2% Zero drift COï¼?±0.06 10-2(%)/4h CO2ï¼?±0.5 10-2(%)/4h HCï¼?±30 10-6(ppm)/4h O2ï¼?±0.5 10-2(%)/4h NOï¼?±30 10-6(ppm)/4h Distance drift No more than shown value error allowed (4 hours) Indication error COï¼?±5%ï¼?absolute errorï¼?±0.03 10-2 ï¼? CO2ï¼?±5%ï¼?absolute errorï¼?±0.5 10-2ï¼? HCï¼?±5%ï¼?absolute errorï¼?±10 10-6 ï¼?±5%ï¼?absolute errorï¼?4001ï½?10000ppmï¼? O2ï¼?±5%ï¼?absolute errorï¼?±0.1 10-2ï¼? NOï¼?±4%ï¼?absolute errorï¼?±25 10-6ï¼? environment condition oil temperatureï¼?±2ï¼?relative errorï¼? speedï¼?±1.0%ï¼?relative errorï¼? temperatureï¼?0ï½?40 humidityï¼?â?¤80% atmospheric pressureï¼?60ï½?105KPa Power Supplyï¼?AC 220V±10%ï¼?50Hz±1Hz(Automobile power supply inverter) Preheating time 10min Weight Measurement unitï¼?10Kg vice machineï¼?3Kg Volume Measurement unitï¼?610 * 500 * 330mm Auxiliary machine:500 * 350 * 330mm Sampling method Exhaust gas: direct sampling, sampling tube length 5m, sampling probe length 900mm; Temperature: the temperature measuring head into the engine lubrication oil scale hole, insert the oil rod and the length of the same length, rubber stopper blocked, to prevent oil jet and wire length: 5m; Speed: the tachometer speed clip in high pressure flexible gasoline engine, can determine the speed of a gasoline engine. Display mode LCD large screen liquid crystal display major function 1)Meet GB18285-2005 national standard requirements, measurement of motor vehicle gasoline engine emissions of HC, CO, CO2, O2 and NO concentrations,Of HC, Co, CO2, the advanced NDIR regardless of light and infrared analysis technology (imported from movement detection equipment to meet the requirements of national standard OIMLR99 0 level precision, high precision, strong stability) and of O2 and no by the new electrochemical analysis technology for detection. 2)With idle speed, double idle test function; 3)Auto calculation shows that the excess air coefficient isï¼? 4)Equipped with RS-232C digital serial communication interface, convenient networkingï¼? 5)Matching speed and temperature measurement functionï¼?
BJ-194Z is a high-end multifunction power meter manufactured by Blue Jay. It is the ideal choice for monitoring and controlling of power distribution systems. With its four direct access keys and LED displays, helps you use all the parameters in 3P3W or 3P4W LV installation. It can be used as a data gathering device for an intelligent Power Distribution System or Plant Automation System. All monitored data is available via a digital RS485 communication port running Modbus-RTU Protocol. Ethernet communication are also options.
Product description Electrical equipments in modern industrial, commercial and residential users are more sensitive to power quality, and have a higher requirement of quality of power supply. Currently, harmonics,electromagnetic interference, power factor reduction have been tied to the three hazard of the power system. When it is interfered or contaminated, grid power quality can t reach the national standards, so it has to be targeted on the grid power quality improvement. To understand the actual situation of power quality, you must have the appropriate equipment to test and analysis the actual situation. Counter the domestic condition, our company developed the professional power quality analysis instrument, which is suitable for the country. 3 phase handheld power quality analyzer Technical index 1. Input characteristics
True-RMS measuring parameters ANSI and IEC 0.2 accuracy class Power quality analysis 4 quadrant energy 2MB onboard memory, can be extended to 16M Data logging High-speed RS485, Ethernet port (option) Measure individual harmonics from 2nd to 63st (option) TOU, 4 Tariffs, 6 Seasons, 6 Schedules Three years warranty With PC management software; web browse data APPLICATIONS Metering of distribution feeders, transformers, generators, capacitor banks and motors Medium and low voltage systems Commercial, industrial, utility Power quality analysis Data logging Monitoring system
Power supply (AC/DC) AC 85-265V/DC 85-330V, DC18-90V (option) Power Consumption:
Stand-combustible Gas Detector BJ-92-1A-11 Combustible Gas Detector Detection of gas: 1A: natural gas BJ-92-1A-11 Combustible Gas Detector Output: * DC12V pulse output * AC220V contact output * AC220V pulse output * AC220V Output * Relay contact (normally open output), with the controller BJ-92-1A-11 Combustible Gas Detector Technical Parameters * Detection of gas: natural gas * Detection method: FIGARO semiconductor gas sensor * Alarm concentration: Gas explosion limit below 25% * Power supply: AC220V 15% * Power consumption: 3W or less * Temperature: -10 ~ 55'C
Point Combustible Gas Detector BJ-86-3A Combustible Gas Detector Detection of gas: Liquefied natural gas Other BJ-86-3A Combustible Gas Detector Technical Parameters * Detection of gas: Liquefied natural gas * Detection method: FIGARO semiconductor gas sensor * Power sourceâ??: DC24V ± 15%â?? * Power consumption: 2.5W or less * Alarm: red light, the alarm sound over 70dB * Temperature: -10 ~ 55'C
Hydrogen Purity Analyzer: Vasthi Portable Hydrogen Purity Gas Analyzers Model VHP- 200 is a light weight, easy to handle, battery-powered analyzer, used to verify measurements and for spot-checking when other methods provide questionable results.
Hydrogen Purity Analyzer: Vasthi Portable Hydrogen Purity Gas Analyzers Model VHP- 200 is a light weight, easy to handle, battery-powered analyzer, used to verify measurements and for spot-checking when other methods provide questionable results.
Portable flue gas analyzers, dew point meter, manufacturing and suppliers, gas analyzers, water analyzer, gas detectors, online gas transmitter.
Major Functions Developed with real Bio-Impedance-Analysis Technology for real measurement. Measure volume percentage of general water nutrition, and display it on a LCD screen. High precision measurement. Easy operation and auto- turn-off. Safety operation guaranteed. When not used for a long time, use alcohol to clean analyzer head before use. When used by other persons, always clean the analyzer head before use. An easy way to measure the absorption rate of cosmetics. Strong guidance on manual with detailed illustrations showing the normal reading ranges for several typical positions on our body for easy caring. Specifications READIBILITY : 0.1% TOLERANCE : ¤g1% WATER CONTENT MEASURMENT RANGE : 0 !V 99.9% POWER SUPPLY : 2 X AA OPERATING CURRENT : 2.5 mA NET WEIGHT : 58g SIZE : 170 X 30 X 24 mm (6.75 X 1.2 X 1.0 inch)
Cable & antenna analyzer, calibrators, fiber optic, meter, oscilloscopes, power meter, signal generator, spectrum analyzers, thermal imager, network analyzers.
AN87500(F) multi-channel power analyzer is specially designed for multi-channel AC/DC power measurement, suitable for power measurement of most electrical appliances, power supplies, motors, inverters and other products. The product takes the high-speed DSP processor as the core, adopts 16-bit high-speed high-performance AD direct sampling method for data acquisition, and can realize multi-channel simultaneous measurement, covering: voltage, current, power, peak voltage, peak current, power factor, crest factor, frequency, electric energy, current integral, efficiency, harmonic content and 3-phase electrical parameters, with serial communication (RS232/RS485, GPIB), remote control, alarm parameter preset and so on, supporting 1P2W/1P3W/3P3W/3V3A/3P4W and other wiring methods, meeting testing requirements of various power supply. Features: Multi-channel: 1~6 channels, flexible configuration of 1~6 single-phase, three-phase three-wire Ã?? 2, three-phase four-wire Ã?? 2, four-phase (DC+ three-phase three-wire) and other modes, satisfy test requirements of varies load (air conditioner, converter, inverter, motor); High accuracy: high-speed DSP processor, 16-bit high-speed high-accuracy AD converter, accuracy up to 0.1%, 100ms display cycle; Wide power range: current up to 50A for a single channel (optional 20A, 10A, 5A, 2A, 1A etc. or combination), minimum 0.lmW power resolution, satisfy test requirements of standby power consumption and rated power; Broadband: AC/DC signals, power measurement bandwidth: DC, 0.5Hz~100kHz, satisfy power test requirements of varies standard and non-standard sine wave load; Multi harmonic analysis: simultaneous 6-channel harmonic analysis, maximum 50th harmonic measurement, distortion analysis, visual display of total harmonic contents and total contents; Multi frequency measurement: simultaneous 6-channel frequency measurement; Line filtering: 500Hz/5.5kHz low-pass filter to measure the fundamental PWM waveform, filter out the high-frequency interference of the switching power supply current; Sensor: variable ratio, common I-I/V-V voltage/current transformers; I-V type current sensor with BNC interface, maximum input voltage 10V, optional high current sensor; Efficiency calculation: measure the input/output energy consumption of the equipment at the same time, and calculate its efficiency; Accumulation of electric energy: positive electric energy, reverse electric energy and integrated electric energy can be separately accumulated to measure the trading electric energy; Threshold alarm: independent 10 groups of voltage, current, power, power factor and other thresholds and measurement threshold for each channel, automatic upper/lower limit judgment and alarm; Chinese/English interface: Chinese or English operation and time/date display.
FEATURES 3s statistical interval, continuously record 168h Support multi-brand current transformer Up to 32G data storage space Record up to 461 power energy parameters simultaneously Up to 10000 screenshots saved Support periodic recording function Up to 3.9M/s USB high-speed transfer Recording wave FUNCTIONS Energy loss calculator: classic active and reactive power measurements, unbalance and harmonic power, are quantified to pinpoint true system energy losses in dollars (other local currencies available). Power inverter efficiency: simultaneously measure AC output power for power electronics systems. Power wave data capture: GF438II analyzers capture fast RMS data, show half-cycle and waveforms to characterize electrical system dynamics (generator start-ups, UPS switching etc.). Waveform capture: GF438II capture 50/60 cycles (50/60Hz) of each event that is detected in all modes, without set-up Automatic transient GF438II analyzers capture 200 kHz waveform data on all phases simultaneously up to 1000V. Fully class-A compliant: GF438II analyzers conduct tests according to the stringent international IEC 61000-4-30 class-A standard. Mains signaling: GF438II analyzer measure interference from ripple control signals at specific frequencies. Troubleshoot: analyze the trends using the cursors and zoom tools. Highest safety rating in the industry: 600 V CAT IV/1000 V CAT III rated for use at the service entrance. Measure all three phases and neutral: with included four flexible current probes with enhanced thin flex designed to fit into the tightest places. Automatic trending: every measurement is always automatically recorded, without any set-up. System-monitor: ten power quality parameters on one screen according to EN50160 power quality standard Logger function: configure for any test condition with memory for up to 600 parameters at user defined intervals. View graphs and generate reports: with included analysis software. Battery life: up to 5 hours operating time per charge on Li-ion battery pack.
Power supply (AC/DC) AC 85-265V/DC 85-330V Power consumption:
Stand-combustible Gas Detector BJ-62-1A Combustible Gas Detector Detection of gas: liquefied natural gas BJ-62-1A Combustible Gas Detector Output: * DC12V pulse output can be driven shut-off valve * No output BJ-62-1A Combustible Gas Detector Technical Parameters * Detection of gas: liquefied natural gas * Detection methodâ??: FIGARO semiconductor gas sensorâ?? * Alarm concentrationâ??: 25% of the lower flammable limit or lessâ?? * Power supply: AC220V ± 15% * Power consumption: 3W or less * Temperature: -10 ~ 55'C
Point Combustible Gas Detector BJ-86-3A Combustible Gas Detector Detection of gas: Liquefied natural gas Other BJ-86-3A Combustible Gas Detector Technical Parameters * Detection of gas: Liquefied natural gas * Detection method: FIGARO semiconductor gas sensor * Power sourceâ??: DC24V 15% * Power consumption: 2.5W or less * Alarm: red light, the alarm sound over 70dB * Temperature: -10 ~ 55'C