1. Cabinet x-ray detection. 2. Do please notice that we are the manufacturer for x-ray security equipment, only for hardware. 3. X-ray security equipment is fabricated from unibody heavy gauge steel, stainless steel and aluminum trim and accessories. 4. Corrosion-resistant command center keypad nounted on side or on available table. 5. Surface treatment as degreasing, acid picking, rust prevention, parkerizing, powder coating finish. 6. All the x-ray security hardware is processed under our cnc technology and machine. 7. We have more than five years oem exprience for overseas company in x-ray security hardware. Packing in carton or crate or as request, and its weight or dimensions based on your quantity.
TUNNEL SIZE: 560(w)*360(H)mm CONVEYOR SPEED: 0.22m/s TYPE: Mutil Energy CONVEYOR: 170 Kg STEEL PENETRATION: 38mm WIRE RESOLUTION: 40AWG WARRANTY: 2 Years PRODUCT NAME: X-ray Baggage Scanner X-Ray Baggage Screening System 5636 Xray Baggage Scanner For Government Office General Specifications Tunnel Size : 560 (W) Ã?360 (H) mm Conveyor Speed: 0.22m/s Conveyor Max Load: 170 kg Single inspection dosage: < 1.32μGy Wire Resolution: 40AWG Steel Penetration: 38mm Film Safety: For ISO 1600 X-RAY GENERATOR Orientation: Upward Tube Current:0.4~0.7mA(adjustable) Anode Voltage:80KV(adjustable) Angle: 60° Generator cooling/working periods: Sealed oil bath with forced air/100% OPERATING ENVIRONMENT Storage Temperature: -20oC to 60oC Operating Temperature: 0oC to 45oC Relative Humidity: 20 to 95% non-condensing System Power: 220 VAC (±10%) 50±3HZ Power wastage: 1.0 KW (Max) Noise
Ge Make Cvt 64 Slice Ct Scanner X Ray Tube Mx240 For Sale.(fully Refurbished Equipment)
Tunnel Size: 500(W)*300(H)mm Conveyor Speed: 0.22m/s Conveyor Max Load: 150kg Wire Resolution: 32AWG to40AWG Spatial resolution: horizontal:1.3 or 1.0mm, vertical: 1.3 or 1.0mm, Penetration: 30 to 32mm Steel Film Safety: Guarantee ISO1600 Film X-ray Leakage:
Tunnel Size:1000(W)*1000(H)mm Conveyor Speed: 0.22m/s Conveyor Max Load: 200kg Wire Resolution: 32AWG to 38 AWG Spatial resolution: horizontal:1.3 or 1.0mm, vertical: 1.3 or 1.0mm, Penetration: 28 to 30 mm Steel Film Safety: Guarantee ISO1600 Film X-ray Leakage:
TUNNEL SIZE: 500 (W) *300 (H) Mm CONVEYOR SPEED: 0.22m/s TYPE: Single Energy CONVEYOR: 100 Kg STEEL PENETRATION: 10mm WIRE RESOLUTION: 40AWG WARRANTY: 2 Years PRODUCT NAME: X-ray Baggage Scanner TIP function Auto operation HPC-B5030 Small size dual energy xray baggage scanner Metro / hotel / train station / public places Model:HPC-B5030 General Specifications Tunnel Size : 500 (W) Ã?300 (H) mm Conveyor Speed: 0.22m/s Conveyor Max Load: 100 kg Single inspection dosage: < 1.32μGy Wire Resolution: 40AWG Steel Penetration: 40mm Film Safety: For ISO 1600 X-RAY GENERATOR Orientation: Upward Tube Current:0.4~0.7mA(adjustable) Anode Voltage:80KV(adjustable) Angle: 60° Generator cooling/working periods: Sealed oil bath with forced air/100% OPERATING ENVIRONMENT Storage Temperature: -20oC to 60oC Operating Temperature: 0oC to 45oC Relative Humidity: 20 to 95% non-condensing System Power: 220 VAC (±10%) 50±3HZ Power wastage: 1.0 KW (Max) Noise
Tunnel Size: 1000(W)*800(H)mm Conveyor Speed: 0.22m/s Conveyor Max Load: 200kg Wire Resolution: 32AWG to 38AWG Spatial resolution: horizontal:1.3 or 1.0mm, vertical: 1.3 or 1.0mm, Penetration: 28 to 30mm Steel Film Safety: Guarantee ISO1600 Film X-ray Leakage:
1. When adding up voltage, total current is less than 2a and total power is 500w; 2. The current and voltage of x-ray tubes are fixed in three groups, they are: X exposure voltag (kvp) 60 65 70 X-ray current (ma) 0.5 0.85 1.10 3. When adding up voltage, total current is less than 2a and total power is 500w 4. Drain current and earth resistance are in accordant with the stipulates in gb9706.1 5. The three groups of voltage (60kv, 65kv, 70kv) are adjustable. 6. Wireless remote control in any angles within 10 meters part form the control box 7. The parameter of x-ray generator (bulb tube head) the parameter of x-ray tubes A focus index: 0.3*0.3mm2 B. The voltage of the-highest-voltage generator: 90kv C. The highest inverse peak voltage: 90kv D. Filament characteristic: vf=5v+0.5v, f=3a E. Target surface obliquity: 12 F. The cooling manner of bulb tube head: oil immersion The parameter of x-ray generator (bulb tube head): A. Focus-skin distance: 200mm B.The thickness of filter-ray film: more than 1.5mmal C.The leakage rate of x-ray: no more than 0.002mgy/h (no. 29.204.3 in gb9706.12 prescript that the leakage rate of x-ray is no more than 0.25mgy/h) D. The manner of limiting beam: using planigraphic device
Detecting such as stone ,sand,teflon,fe,sus ,non-fe,harder material and so on in the food stuff
Features: 1. One-button shutdown: turn off only need to turn the key, the device automatically safe shutdown, more humane. 2. Emergency stop hierarchical control: press the tight stop button, only the power transmission and ray source part, more secure. 3. Image ultra-clear: the core components of high-density imported modules, higher resolution, to the international level, more clear. 4. Waterproof function: the channel within the special treatment,there is no effect a small amount of passengers scattered liquid, more at ease. 5. self-diagnosis: automatic fault diagnosis, and give a message, easy to maintain. 6. zoom function: continuous mouse zoom function, more continuous. Unique mouse magnifying glass function, any local details zoom, more accurate. Has a specific role in identifying specific explosives. 7. Detection of objects: parcels, large bags, suitcases, bags and other large objects. Applications: 01. Airports, 02. Transport terminals, 03. Buildings, 04. Factories (to find needle in clothing, shoes, bags), 05. Courthouses, 06. Embassies, 07. Military installations, 08. Prisons, 09. Hotels, 10. Schools , 11. Convention centers, 12. Security checkpoints 13. Special events location technical standard Electrical appliances with reference to EN60950 safety standards Radiation is carried out with reference to EN50081-1 Strict implementation of the current X-ray security equipment national standards Fully through the ISO14001: 2004 environmental management system certification Fully through the OHSAS18001: 2007 occupational health and safety management system certification Fully passed ISO9001: 2000 quality management system certification Technical Parameters: Dimensions: 4436 (length) x1330 (width) X1865 (high) mm Channel Size: 1000 (W) X800 (H) mm Conveyor speed: 0.22m / s Conveyor max load: 200kg Resolution: diameter 0.101mm metal wire Spatial resolution: horizontal diameter 1.0mm; vertical diameter 1.0mm Penetration:10mm ~ 48mm steel plate (can be customized) Film safety: Safety for IS01600 film Leakage dose:
Specifications: Tube Voltage): 60kV Tube Current: 1mA Exposure Time: 0.02~2S Tube Focus: 0.3*0.3mm Frequency: 30kHz Battery: DC14.8V 6400mA Rated Power: 60VA Charger Input: AC100V-240V±10% Charger Output:DC16.8V Weight:2.2kg Size:138*165*185mm The distance from skin to cone: 130mm
X - Ray Tubes , CT tubes Our products are with german brand NAGO and german technology. We provide X-ray tubes for medical ,industry and inspection systems . The tubes can replace Siemens , Philips , Varian ,Toshiba ,IAE and other brand tubes . We provide also X-ray tube accessories like glassbulb, target , rotor and so on. Offering mechanical parts processing work according to customer's drawing and requirements .
100 mA, 100 KVP Mobile X-ray Machine 100mA, 100 KVP, Mobile X-ray Machine for Radiography only Electronic Timer Electronic Overload Protection Device Stationary Anode X-ray Tube : BEL or Imported Collimator Counter Balanced Mobile Stand Suitable for Bed Side X-rays
Suited to a range of imagers and general radiology applications Five film sizes on 7-mil blue polyester base AIQC system-matched with the DRYVIEW Laser Imagers AIQC ensures contrast and density meet preset user preferences Quality control performed without operator intervention to enhance productivity Storage and Handling of Film Unexposed DRYVIEW DVE Film must be stored at 39 to 75�?�°F (4 to 24�?�°C), at 30 to 50% RH, and properly shielded from x-rays, gamma rays, or other penetrating radiation in order to achieve consistent results up to the expiration date indicated on the film package. Note that DRYVIEW models 8700, 8150 and 8300 are not compatible with DVE Film. To determine if your laser imager needs a software upgrade or is compatible with DVE �¢?? download our information sheet here. Choose from five sizes on 7-mil polyester base to suit your DRYVIEW Laser Imager and imaging applications: 14 x 17 in. (35 x 43 cm.) 11 x 14 in. (28 x 35 cm.) 10 x 12 in. (25 x 30 cm.) 8 x 10 in. (20 x 25 cm.)
We're a leading XRay machine and accessories manufacturer company with over 29 years of experience and global presence and distributor network in 7 different countries. We have Line Frequency & High Frequency, APR X-Ray Machine, Dental X-Ray Machine, Mobile 100MA X-Ray Machine, 300MA X-Ray Machine, 500MA XRay Machine, Vertical Bucky, Multi-Position Bucky Table, 4 & 2 Way Floating Bucky Table Etc Beside new machines, we offer complete modification & repairing of any brand XRay machines, Rotating Anode Tube Head, HT 100MA, 300MA, 500MA Etc
Power Output 5.0KW x ray machine Main Inverter frequency 40 KHz X-ray Tube of radiography machine fixed anode focus: 1.5 (X-ray tube for high frequency) Power Supply 220V�±10% 50Hz Inner-resistance â?¤1.0�© Operation Method Wire/wireless control mobile x-ray machine safety mobile x ray machine cost mobile x ray machine price
Power Output 5.0KW Frequency 40KHz Power Supply 220V± 10% 50Hz inner-resistance Operation Method Wire/Wireless control mobile x ray machine cost mobile x ray machine price mobile x ray machines ww1
Mobile 100mA high frequency X-ray system PLX101C for sale Item Contents Environmental Conditions No erosive volatile gas and dust around Temperature +10â??~+40â?? Relative Humidity 30%~75% Atmospheric Pressure 700 hpa~1060hpa Power Output 5.0KW Frequency 50kHz Tube Voltage 40~120KV Power Supply 220V±10% 50/60HZ Internal Resistance less than input power 9kVA Operation Method Wire/Wireless Control Dimension 120cm*62cm*130cm Net Weight 150kg mobile x ray machine cost mobile x ray machine price mobile x ray machine ww1
2.5kw high frequency portable X-ray machines PLX101 x ray tube Fixed Anode Power Output of x ray machine 2.5kW Frequency 25kHz Tube voltage 40~100kV Power Supply 220V�±10%, 50kHZ Operation Method Wire/ Wireless control price list of x-ray machine price of 500ma x-ray machine price of medical x ray machine
brand of surgical x-ray equipment PLX101D mobile x ray machine for sale price of x ray machine mobile x ray machine specifications Power Output 5.0KW x ray machine Main Inverter frequency 40 KHz X-ray Tube of radiography machine fixed anode focus: 1.5 (X-ray tube for high frequency) Power Supply 220V±10% 50Hz Inner-resistance Operation Method Wire/wireless control