New cars, new vehicles, used cars, used vehicles, second hand cars, second hand vehicles, used construction machinery, used excavators, used truck crane, used tower crane and .etc..Import and export agent
Agro commodities such as cocoa, cashew nuts, ginger, tumeric, sunflower, hibiscus flower, bitter kola, palm oil.Export and facilitate
.Source and supply chains
Non-Sterile Medical Examination Nitrile Gloves Powder free & Latex free 100% Virgin raw materials with FDA certificate & as per ASTM D6319/ CE EN 455 Quality standard: ASTM D6319, with 510K and FDA, CE/EN455, Color: Blue, white Finger Tips: textured Cuff: Beaded Pcs per Box for S/M/L/XL : 100pcs/box Origin: China, Vietnam, Thailand, Malaysia Benefits Protection from unwanted and harmful substances Beaded Cuff ensures easy donning and prevent roll down Superior Strength with better Puncture resistance Finger Tip Textured enhances wet and dry grip Thinner Guage improves tactile senstivity Custom Design enhances comfort and fit Provide an Alternate Solution for individual who are allergic to natural rubber latex Material : Synthetic Nitrile Type : Non-Sterile Powder Free, Amibidextrous, Finger Tip Textured, beaded cuff. Storage: Store in a dry and cool place, the temperature not higher than 38�° C Shelf life: 2 years Physical Properties Tensile Strength: Before Aging 14Mpa min Tensile Strength: After Aging 14Mpa min Elongation at Break (%): Before aging 500% min Elongation at Break (%): After aging 400% min Length: 230 mm in XS, S, M, L, XL Width: 70+/- 10 (XS) Width: 80+/- 10 (S) Width: 95+/- 10 (M) Width: 110+/- 10 (L) Width: 120+/- 10 (XL) Thickness Single wall ( mm): Fingers 0.050mm min Thickness Single wall ( mm): Palm 0.050mm min
18 mt Tantalite ore is currently available in Bollore Logistics bonded warehouse in Zambia. Looking for buyer who can buy form the Bollore logistics
We can source copper cathoe from various sellers depending on your requirements. Copper cathode @ -15 to -20% LME, both LC& TT payments from congo/zambia/tanzania Delivery CIF and to steinweg warehouses.
Herbal cosmetics All are as per standard. All products are hygiene controlled. All are exporting to worldwide specially in Japan 100 kg, 50 Kg, 10, 100 Gm
Copper, aluminium, ferrous and non ferrous scrap , rice, cotton, yarn, teak wood, saffron, dry fruits, chemicals.Sourcing agent
Description TGS5141 is a battery operable electrochemical sensor which uses a unique electrolyte that eliminates the need for a water reservoir. By eliminating the water reservoir used in TGS5042, the comparative size of TGS5141 is reduced to just 10% of TGS5042. With its ultra compact size, this sensor is the ideal choice for size oriented applications such as portable CO detectors, small residential CO detectors, and multi-sensor fire detectors. OEM customers will find individual sensors data printed on each sensor in bar code form, enabling users to skip the costly gas calibration process and allowing for individual sensor tracking. Features: Ultra compact Battery operable High repeatability/selectivity to CO Linear relationship between CO gas concentration and sensor output Simple calibration Long life UL recognized component Meets UL2034, EN50291, and EN54-31 requirements Applications: Residential and commercial CO detectors Fire detection
AR5750B Refrigerant/SF6 Gas Leak Detector Description This rechargeable refrigerant gas detector respond to all halogenated refrigerant, but also apply to: A. This was response to all halogenated refrigerant (including chlorine and fluoride). Including but not only limited to below: CFCs e.g. R12, R11, R500, R503 etc... HCFCs e.g. R22, R123, R124, R502 etc... HFCs e.g. R134a, R404a, R125 etc... Also can detect compound gas for example AZ-50, HP62, Mp39, etc... B. Detect gas leaks in hospital equipments. C. SF6 gas was detected in high voltage circuit shot cut.. D. Detect halogen gas when gas mixing with, chlorine, fluorine, bromine. E. Detect carbon tetrachloride from the dry cleaning machine. F. Detect the halon gas from the fire extinguisher. AR5750B Refrigerant/SF6 Gas Leak Detector Specifications * Detect item: All halogen gas * Sensitivity: Halogen refrigerant gas 3gr / yr * Response time: Instantaneous * Warm up time: < 6 second * Continuous operation time: 5 hours(slightly vary with operation) * Operation temperature: 0 to 52C( 0 to 110F) * Power supply: 2000mAh, 3.7V lithium rechargeable battery
Sd13 smoke alarm key features: * worry-free! 10-year sealed-in lithium battery * advanced photoelectric sensing technology offers high sensitivity * auto-check malfunction * low battery warning * manual test & auto-reset * dustproof, mothproof & anti-visible light * anti-rfi (20v/m-1ghz) Sd13 smoke alarm specifications: * sensor type: photoelectric * alarm sound: >85db (3m) * power supply: dc 3v lithium battery (included) * power supply life: 10 years * alarm current:
SD11 Smoke Alarm Key Features: * Worry-free! 10-year sealed-in lithium battery * Advanced photoelectric sensing technology offers high sensitivity * Auto-check malfunction * Low battery warning * Manual Test & Auto-Reset SD11 Smoke Alarm Specifications: * Sensor Type: Photoelectric * Alarm Sound: >85dB (3m) * Power Supply: DC 3V lithium battery (included) * Power Supply Life: 10 years * Alarm Current:
MF5000 series Gas Mass Flow Meters General description MF5000 series mass flow meters are specially designed for small pipe flow monitoring and feature an extremely low pressure loss compared to the traditional by-pass thermal mass flow meters in this application scope. The accuracy of the meters are generally (1.5+0.5FS)% or better depending on the requests. The meters can work at an environment of -20 to 60'C and pressure up to 1.5 MPa. Applications include semiconductor gas process monitoring and control, hospital oxygen gas monitoring, etc. MF5000 Series have 5 designs, with model number: MF5003/MF5006/MF5008/MF5012/MF5019. MF5000 series Gas Mass Flow Meters Features and Applications - Highly sensitive, measuring as low as 8 mm/sec, and as high as 65 m/sec with a single assembly - Directly sense mass flow using thermal mass flow principle - Proprietary MEMS sensor package design for better reliability - Standard 12 ~ 24 Vdc power supply - Low pressure loss forreducing energy cost - Industrial standard Modbus protocol for easy networking and remote control MF5000 series Gas Mass Flow Meters Specifications * â??Accuracy: (1.5+0.5 FS)% * Environment: - Temperature: -20 ~ +60'C; - Humidity: < 95%RH (No icing or condensation ) * Flow channel: 3 ~ 19 mm * Display: Flow rate and accumulated flow * Interface: 4 ~ 20 mA; RS485; Pulse * Calibration: Air @ 20'C; 101.325 kPa
UM0090 Ultrasonic Rangefinder Introduction The UM0090 module is based on an ultrasonic sensor that combines transmitter and receiver in a single unit. By measuring the time of flight of ultrasonic wave, it can detect any object within 3 meters and output distance signals via UART interface. This product features high sensitivity, fast response, and excellent anti-interference ability and stability. It is widely applied in object avoidance systems on robots, drones, and other smart devices. UM0090 Ultrasonic Rangefinder Features * Compact design for easy installation * Measuring range up to 3M * Excellent anti-interference ability * Can detect objects of various colors, shapes an UM0090 Ultrasonic Rangefinder Applications * Robots * Smart streetlight * Smart trash bin * Autonomous delivery vehicle
FOS-N Fiber Optic Strain Sensor Description The FOS-N is a fiber optic strain sensor, ideal for composite material engi-neering research and civil-engineering applications such as structural health monitoring of buildings, bridges, tunnel linings and supports. FOS-N Fiber Optic Strain Sensor Key Features * Immune to EMI/RFI/lightning * Intrinsically safe * Static/dynamic response * High sensitivity and resolution: 0.01% full scale * Signal transmitted over long distances * No interference due to cable bending * Absolute measurements in engineering units FOS-N Fiber Optic Strain Sensor Applications * Torque measurement * New material research and development * Civil engineering * Tunnel linings * Nuclear power plants * Structural health monitoring * Corrosive environments * High EMI/RFI environments FOS-N Fiber Optic Strain Sensor Specifications * Strain range: ±1000, ±2500, ±5000 * Resolution: 0.01% of full scale * Transverse sensitivity: < 0.1% of full scale * Connector type: ST connector * Operating temperature: -40 to 250'C (-40 to 482'F) * Glass tube dimensions: ±1000: 10 mm ; ±2500 or ±5000: 8.5 mm
SD12 Standalone Photoelectric Smoke Alarm Key Features: * Worry-free! 10-year battery life * Advanced photoelectric sensing technology offers high sensitivity * Auto-check malfunction * Low battery warning * Manual Test & Auto-Reset SD12 Standalone Photoelectric Smoke Alarm Specifications: * Sensor Type: Photoelectric * Alarm Sound: >85dB (3m) * Power Supply: DC 3V lithium battery (included) * Power Supply Life: 10 years * Alarm Current: