Available in sizes from dn 10 to 300 mm (1/2"÷12"); High grade stainless steel, titanium, or tantalum integrated electrodes; Different lining materials available (ptfe or polyurethane); High accuracy and stability of measurement; Flanged or wafer-type connection (wafer-type connection for Dn10, 15 mm); Bidirectional flow measurement (on request); Remote design available (display unit can be placed away from flow tube at 1 km maximum); Batching mode available; Suitable for mounting on polymer pipes; Oiml and iso 9001:2008 certified; Integrability into automatic industrial control systems.
Available in sizes from dn 10 to 300 mm (1/2"÷12"); Flanged connection (wafer-type connection for Dn10, 15 mm); Bidirectional flow measurement (on request); Full-bore meter design eliminates pressure loss in measurement section; No filtering required; Short straight pipe runs required for installation; Protection against unauthorized access; Suitable for mounting on polymer pipes; Oiml and ISO 9001:2008 certified.
Type: lc series marine ellipse gear flowmeter Material:cast iron , cast steel , stainless steel Size: dn10 - dn200
Digital flow meter Gas metering skid Electromagnetic flow meter Gas flow meter Oil metering skid Oil flow meter Steam flow meter. 1
Technical Data: Flow Rate:200L/min, 400L/min, 500L/min, 800L/min Precission:1% Pressure:420bar Temperature:150. Weight:6.1kg,8.8kg,10.2kg,17.5kg Specipications:280,245,172(mm).
Use ultrasonic flow measurement technology, no mechanical moving parts drift diameter design, no pressure loss, cut down the electric consumption of the pump and help untilities reduce cost. Features: Low in initial flowrate, and the min. Flow velocity measured is0.002 m/s; Measurement cycle 1 time per second, battery powered (One battery can work continuously for 6 years); Multi-channel construction design, double cross section measurement, and be able to ensure the measurement accuracy to the largest extent; Be able to work at any flow point for long time; IP68 of the whole meter, for each unit of the meter is IP68 designed; Micro-consumption design, less than 0.0008W; Drift diameter design, no pressure loss. Operating on velocity-difference principle, the LG-UWM68 series is specially designed for urban water supply and building-use. The conventional water meters suffer from the drawbacks that they are only operable at a higher flowrate and are insensitive to a small flowrate. However, the LG-UWM68 series water meter can help tackle the bottleneck. And the meter is highly adaptable to diversified industrial conditions Due to the use of ultrasonic flow measurement technology, it has no mechanical moving parts drift diameter design, no pressure loss, cut down the electric consumption of the pump and help the enterprises reduce cost Be able to work at any flow point for a long time and high in reliability, immune to magnetic interference Battery-powered capable of operating continuously for a period of over 6 years with a single cell High sensitive to minimal flowrate and high in measuring accuracy Capable of performing various output function, and it is capable of making wireless transmission of meter reading to form a monitoring system via the GSM network to monitoring the meter's running status and the pipe network conditions. Three design versions are available, i. e. The ordinary version, 2-way version and fire water version are cater to different needs of users Ordinary version: Measurements of the flowrate and cumulative running time in positive direction 2-way version: Capable of measuring flowrate, cumulative flowrate cumulative running time in positive/reverse direction; Fire water version: Much bigger range ratio, and specially designed for fire water. CE: 2004/108/EC The meter is in conformity with Standard on Measurement of Water Flow in Fully Charged Closed Conduits_Meters for Cold Potable Water and Hot Water GB/T 778-2007-a standard is issued by the People's Republic of China L Ex-factory calibration of the meter is made in conformity with Standard on Water Meter for Potable Cold Meter JJG162-2009- a standard is issued by the People's Republic of China.
Strainers, rotameters, oil meters, water meters, electromagnetic flow meters, pressure gauges, temperature gauges, temperature sensors.Calibration and repair of Flow Meters
Constant flow pump, oval gear meter, glass rotor flow meter, rotor wing flow meter, spiral rotor flow meter, rotary piston flow meter.
Profile A certain amount of water as defined by meter body passing through makes piston move. The measuring structure records its movements. Movements times defined amount making total amount of water passed registered. Features 1. Rotary piston structure. It registers total amount of water passed in the tube by calculating how many times the piston rotates. 2. Dry and wet type are both separated from water so as to keep the registering clear. 3. Registering is stable and high-graded measurement. Easy to install. 4. Long endurance with no rotating inclination and long work life. 5. Various types available to register pure water or to be installed in any position. 6. Remote transmission device can be added upon request. 7. Different structures and specifications with beautiful appearances are available. 8. Meter bodies can be of copper, SS or plastic. 9. All technical figures are conformed with GB/T778.1~3-1996 which is equivalent to IS04064 Standard Class C. Working condition L Water temperature≤ 45º C L Water pressure≤ 1Mpa (≤ 0.6Mpa for LXH-8S). Maximum permissible error L From the minimum flow-rate (qmin ) inclusive to the lower zone of the transitional flow-rate (qt ) exclusive: ± 5%.
Piston Seals or Glyde Rings are used in hydraulic cylinders for fluid sealing. They are internal to the cylinder head and seal against the cylinder bore, preventing fluid from flowing across the cylinder head. This allows pressure build up on one side of the piston, making the cylinder extend or retract. â?? Seal Materials (PTFE Grades): BR40, BR40M5, BR55M5, GL5M5, GL15M5. Temperature Range: -50�°C + 200�°C (Depend upon O ring material) Operating Pressure: Up to 800 bar (80Mpa) O Ring material: Nitrile Rubber, Viton. Seal Profile Size Range: We manufacture PISTON Seals for the following range of cylinder bore diameter - 8mm to 700 mm
Accuracy & repeatability · Accuracy: +/-0.5% of reading from 0.03ft/s to 40ft/s (0.01 to 12m/s) · Repeatability: +/-0.15% of reading Description · Transit-time ultrasonic · Clamp on transducer and insertion transducer versions · High accuracy at low and high flows · Bi-directional flow · Clear, user-friendly menu selections Fluids measured · Water and liquids, tolerant of liquids with small amounts of air bubbles or suspended solids Flow range · Bi-directional flow range of 0.03ft/s to 40ft/s (0.01 to 12 m/s) Pipe sizes from 1 to 200 inches (25 to 5000mm) Digital communications · RS-485, Modbus RTU SD card · Standard SD card · Max record: 512 days · Record time interval Outputs · OTC pulse output :0~9999 Hz · Analog output : 4~20mA · Max load 750Ω Temperature · Transmitter: -40-140F (-40-60C) · Transducer: -40-176F (-40-80C)
Accuracy & repeatability Accuracy: +/- 1.0% of reading from 0.03ft/s to 40ft/s (0.01 to 12m/s) Repeatability: +/- 0.3% of reading Description ·Transit-time ultrasonic ·Handheld, easy to carry ·Clamp-on outside of pipe for easy set up ·No pipe cutting or process shutdown ·High accuracy at low and high flows ·Bi-directional flow Fluids measured Water and liquids; Tolerant of liquids with small amounts of air bubbles or suspended solids Flow range Bi-directional flow range of 0.03 ft/s to 40 ft/s (0.01 to 12 m/s) Pipe sizes from 1 to 48 inches (25 to 1200mm) Pipe material Carbon sheet ; stainless sheet ; PVC Digital communications RS-485, Modbus RTU Out puts OTC pulse output :0~5000 Hz Analog output : 4~20m A , max load 750Ω Temperature Transmitter: 14F~122F(-10C~50C) Transducer: 32F~176F(0C~80C)
Handheld ultrasonic flow meter Installation method: Handheld SD card high memory data logging, maximum memorize 512 days data. Flow range: +/-0.03 ft/s ~ +/-40 ft/s (+/-0.01 m/s~ +/-12 m/s) Accuracy: +/-0.5% of measured value Repeatability: 0.15% Output: 4-20mA Internal lithium power supply: 10hours Pipe size range: 0.6â?³~240â?³(15mm~6000mm) Transducer: IP54, CP magnet portable transducer, 5m cable
X-meter mass flow meter
In our company, we have the stock of Diesel flow meter of all calibers. From this, it is not hard to find that our company has sufficient funds and our products sale good. Nowadays, there hardly exist companies who own the ability to keep stock. But we dare and have the strength to do that.
Our company cherish the slogan quality in Germany and the price in China to make world-class Diesel flow meter and to be the benchmarking enterprise in the automatic instrument industry.
Aliava avf250 series is a common used various flow meter in auto-industry process control. It's with small volume, wide range and easily operation. It could also measure liquid, gas and steam flow rate, especially fit for small flow rate application. Features 4 digit flow rate & 8 digit totalizer Local indication without auxiliary power 4-20 ma & scale pulse output Low pressure lost on gas and steam application Damper for gas/steam application Consistent overall length Heating jacket design Intrinsically safe & explosion proof for hazardous area Specification Size: 15, 20, 25, 40, 50, 65, 80, 100, 125, 150, 200 mm Measuring range: Liquid - 1 ~ 200000 liter/hr Gas - 0.03 ~ 4000 m3/hr Turndown ratio: 10:1 (20:1 optional) Accuracy: +/-1.6%(standard) +/-1.0%(optional) Material: Tube & float: Stainless steel 304 Stainless steel 316 Stainless steel 316l Stainless steel + ptfe liner Standard pressure: 40 kg/cm2 (15mm ~ 50mm) 16 kg/cm2 (65mm ~ 200mm) Flange type: Jis 10k / jis 20k / jis 40k / ansi 150# / ]ansi 300# / ansi 600# / din pn 10 / Pn 16 / pn25 / pn 40 Local display: Mechanical indicator (standard) Digit display: 4 digit flowrate 8 digit totalizer Protection class: Ip 65 Intrinsically safe, eex ia iic t5 Explosion proof, ex d iib t6 Pressure drop: 0.07 ~ 0.7 kg/cm2 Standard
Aliavtx avf7000 is a vortex flowmeters based on von karman theory of vortices generated by a bluff body in the pipe. The number of vortices are linearly proportional to the volumetric flow in the pipe. The avf7000 is versatile flowmeter widely used for gases, steam & liquid applications. There are no moving parts and comes with either Flange or wafer connection. Standard configuration comes with local indication for flowrate and total flow as well as a 4-20ma output function output. The electronics are designed to filter out erroneous signals as well as noise due pipe vibration. Features Simplified setup and diagnostic functions. Auto. Temperature & pressure compensation 4-20 ma and pulse outputs, user selectable. A very wide selection of sizes. Wide temperature range of up to 420 deg. C. Non-volatile memory for setup and calibration. Specification Size:10, 15, 20, 25, 32, 40, 50, 65, 80, 100, 125, 150, 200, 250, 300, 350, 400, 450, 500mm Material: Stainless steel 301 / 304 / 316 Accuracy: Liquid:+/- 0.7% of reading Gas & steam:+/- 1.0% of reading Process connection: Flange / wafer Flanges type: Jis 10k / jis 20k / jis 40k Ansi 150# / ansi 300# / ansi 600# Din pin 10 / pn 16 / pn25 / pn 40 Temperature: -40 ~ +280 deg. C (standard) -40 ~ +420 deg. C (optional) Protection: Ip 65 Explosion proof, exd iic t6 Intrinsically safe, e ex ia iic t4 Local display: 4 lines lcd 4 digit flowrate 8 digit totalizer Communication: Rs485 Standard
The adp9000 offer of configurations for differential, gas, absolute vacuum liquid-level measurements including integrated solutions for pressure, level and flow. Features Updating time of output current in 200 ms Improved performance, increased accuracy, greater stability Two years stability of 0.2% 0.075% accuracy Parameter setting by local keypad or rs485 communication port 4-20 ma output plus direct digital hart communication Automatic zero calibration by push button Explosion proof and weather proof housing Specification Process fluid: liquid, gas of vapor Application: differential pressure, gauge pressure, absolute pressu Measuring range:0 - 0.25 kpa ~ 0 - 1.5 kpa ( minimum ) 0 - 4.0 mpa ~ 0 - 25.0 kpa ( maximum ) Accuracy:+/- 0.75% of span Material: Flange/adapters: stainless steel 304 / stainless steel 316 Drains/vents: stainless steel 304 / stainless steel 316 Diaphragms: stainless steel 316l / hastelloy b /hastelloy c / monel / tantalum Wetted o-rings: Buna n / viton / ptfe Bolts & nuts: carbon steel / stainless steel 316 Mounting bracket: carbon steel / stainless steel 304 / 316 Name / tag plate: stainless steel 304 / stainless steel 316 Converter housing: low copper cast aluminum alloy with polyurethane, light blue paint Enclosure:ip67 ( standard )/intrinsically safe eex ia iic t5 ( standard )/ex Standard
Ultrasonic thickness meter Ultrasonic thickness gauge series Tr-8812 /tr-8811 tr-8810 Measuring range:1.0~225mm /1.2~200mm / 1.2~200mm 0.05~9 inch /0.06~8 inch /0.06~8 inch Sound velocity: 500~9000m/s. Resolution : 0.1mm. Accuracy: +/-(0.5%n+0.1).Operating conditions : 0~400c/10~90%rh. Dimensions: 120*62*30mm /160*68*32mm . Weight: 164g/208g