The WTF-B500 anemometer / wind meter offers users a very effective and proven solution for monitoring wind speed. When actual wind scale reaches the parameter which we signed Fxx, indicator will alarm, guiding lights will flicker. When actual wind scale rises to the parameter which we signed Pxx, indicator will alarm, guiding lights will flicker, and control relay action.
Maximum Power(Pmax): 100W Open Circuit Voltage(Voc): 123.9V Short Circuit Current(Isc): 1.36A Maximum Power Voltage(Vmpp):90.5V Maxium Power Current: 1.11A
Overview Cable check and cable, cable lookups are a bit a bit of arbitrary wiring (no need to publicly line). It can greatly improve the construction progress, which is a new test tool in on-site construction such as electricity, telecommunications, automation control. The cable calibration equipment is based on the characteristics of foreign new types of wire tools, combined with the actual situation of China, using digital identification technology, making the test work simple and accurate. Technical parameter: Parameter Display the maximum row of LEDs 1000 the maximum distance of the quilt is 40km / 1.5ma size Transmitter Size: 135 * 70 * 24MM Receiver Size: 135 * 70 * 24mm Function 1. The entire instrument consists of a transmitter and a receiver; 2. There is no need to determine the public line to make it easy to use; 3. Wire recognition, distribution, application to a part of the wire or multi-heeled wire; 4. One item can be identified, if you need to distinguish more wires can measure or use multiple instruments; 5. Can determine whether there is a short circuit or disconnect between the wires; 6. The receiver is also a disconnect detector that can be used to measure whether the wire is turned on; 7. The structure is small and easy to operate.
Digital Ground Resistance Tester Rejects the traditional manual manual power generation method adopts advanced media and large scale integrated circuits, and uses DC / AC conversion techniques to combine the triple buttons and four-end button measurement modes with new ground resistors. . The working principle is that the DC / AC converter in the machine changes the DC constant current, and the circuit is formed by the auxiliary ground electrode C and the measurement object E, which generates an AC voltage drop on the measuring object, and feeds the AC amplifier through assist grounding. The electrode P amplified, and then multiplied by multiplying by multiplying by a power switch to display the instrument header head, you can get three different number limits Nearly the resistance tester is suitable for measuring the electrical resistance of low resistance of various departments such as various devices and power postal railway communication mining; Nearly the ground resistance tester also measures soil resistivity and ground voltage. Technical parameters Working Conditions Ambient temperature 0+45 Relative humidity 85%RH Measurement range and constant current value (effective value) Resistance 020(10mA)2200(1mA)202000(0.1mA) Voltage AC019.99V Measurement accuracy and resolution Precision rowspan 0 0.23%1d
Features: - Compressed Air gun with accessories It has a low connection and allows to adapt a tip that best corresponds to the type of use. - Water gun. This bellows combines the progressivity of the breath, thanks to an integrated pressure regulator Accessories included: straight tube end, curved tube end, safety end and flexible tube end
REVOLVING STOOL FIXED STOOL SS SINGLE STEP STOOL DOUBLE STEP STOOL SALINE STAND KICK BUCKET SINGLE TIER BOWL STAND TWO TIER BOWL STAND BED SIDE SCREEN WHEEL CHAIR FOLDING WHEEL CHAIR SINGLE SECTION MATTRESS TWO SECTION MATTRESS FOUR SECTION MATTRESS AIR MATTRESS
LZZG rotary trommel scrubbers are cylindrical drum type stone scrubbers. Which are mainly used for cleaning, desliming of gravels, aggregates, sandstone and ore, espical lump ores that are hard to clean. LZZG rotary drum scrubber has a large-sized feed materials ability(materials within 0-300mm), sludge content of washed aggregates is less than 0.5%, the water content is less than 2%, and the ore washing efficiency is about 98%. LZZG rotary trommel scrubbers divided into two types: cylinder type and cylinder +trommel screen type.
* Online Coagulant Dosage Analysis & Control System (Model: CAST) - Optimal Flocculation, Membrane Pretreatment, T-P Removal and Polymer dosage control for a decanter. - Coagulant dosage determination based on colloid coagulation theory. - Optimal dosing of coagulant depending on inflow water quality change. - Stable operation even though highly turbid raw water inflow - Applications : Water Purification Plants (Coagulant control for optimal flocculation of drinking water plant), Membrane Pretreatment (Reducing membrane fouling), Sewage Treatment Plants (Coagulant control for T-P and polymer dosage control up to 4 decanter)
Made from high quality DAKUA MAKANDRE hardwood. Length 450mm Thickness 25 mm Width 75mm
Product description Ground continuity tester is the connecting part of power equipment and grounding gird, during long time run of power equipment, Connection is likely due to moisture and other factors, node corrosion, even fracture phenomenon, lead to lead off the assembly line and the main grounding grid connection point resistance increase, there is no security risk in the operation of the equipment, serious when will cause the equipment to run away from the grounding grid. Technical index Technical parameter Current 10A 5A 1A 100mA Range 10A 500 2 5A 1m 4 1A 10m 20 100mA1 200 Resolution 0.1 Precision 0.2%R 2D Radius 50m Dimension 345mm 295mm 175mm Weight 5kg Operation condition Temperature -10 50 Humidity 85% RH Power supply AC220V 10% Frequency 50 1Hz
Product description Earth ground resistance tester is a high-precision testing instrument used in various fields such as substations to test grounding resistance and related parameters.The instrument is of an integrated structure, with a built-in frequency conversion power supply module, and the output power supply is continuously variable in frequency. The frequency can be changed to 45Hz or 55Hz, the high-speed processor core is built in, and the high-end digital filtering technology is adopted, thus effectively avoiding the interference of power frequency electric field to the test and fundamentally solving the difficult problem of accurate measurement under strong electric field interference. Technical index 1 Conditions of use 15 40 RH 80% 2 Anti-interference principle Frequency conversion method 3 Electric source AC 220V 10% allowed generator 4 Measure output current 1A 5A Adjustable 5 Measure output voltage V100V 6 Test power frequency 45, 50, 55, 60, 65HZ single frequency 45 55, 55 65 47.5 52.5HZ Automatic Dual Frequency 7 Output rating 500W 8 Distinguishing rate Grounding impedance 0.0001 Impedance angle 0.0001 9 Precision Grounding impedance (1% reading +0.002) Impedance angle (1% reading +0.02 ) 10 Resistance measurement range 0.001 5
Overview The instrument is designed for HV substations and power plants to test the characteristic of large HV transformer, electric machines and appliances, remote power cable or buried cable and other electrical insulation resistance in strong interference environment. It also can be widely used for testing characteristics of insulation resistance in other area. Technical Parameters Technical parameters Measurement voltage range 0.5kV 1kV 2.5kV 5kV 10kV 20kV Measurement voltage accuracy 5% 10V Short circuit current 10mA Measurement range and accuracy Measurement range Resistance measurement range Accuracy 20M 0.01 19.99M 5%+3d 200M 5.0199.9M 5%+3d 2000M 50 1999M 5%+3d 20G 0.519.99G 5%+3d 200G 5.0199.9G 10%+3d 2000G 50 1999G 20%+10d
Overview At present in the electric power system the grounding resistance of the earth network is mainly measured by power frequency large current tripole method. In order to prevent power frequency interference during power grid operation and improve the accuracy of measurement results insulation preventive test regulations stipulate that the test current of power frequency high-current method shall not be less than 30A. As a result there are many problems such as bulky test equipment complicated test process high working intensity and long test time. Ground Network Earth Resistance Tester adopts new frequency conversion ac power supply and adopts microcomputer processing control and signal processing and other measures which well solves the anti-interference problem in the test process simplifies the trial operation process improves the accuracy and accuracy of the test results and greatly reduces the labor intensity of test personnel and test cost. Ground Network Earth Resistance Tester is suitable for testing power frequency grounding impedance contact voltage step voltage power frequency characteristic parameters and soil resistivity of various grounding devices. measurable substation ground network (4) water and fire power plants microwave station (10) the lightning rod 10 multi-purpose machines. Ground Network Earth Resistance Tester adopts different frequency anti-interference technology which can accurately measure data at power frequency of 50Hz under strong interference environment. The maximum of test current is 3A which will not cause excessive potential of grounding device during the test. Meanwhile it also has strong anti-interference ability so it can be measured without power failure.
Overview Digital Ground Resistance Tester Rejects the traditional manual manual power generation method adopts advanced media and large scale integrated circuits, and uses DC / AC conversion techniques to combine the triple buttons and four-end button measurement modes with new ground resistors. . The working principle is that the DC / AC converter in the machine changes the DC constant current, and the circuit is formed by the auxiliary ground electrode C and the measurement object E, which generates an AC voltage drop on the measuring object, and feeds the AC amplifier through assist grounding. The electrode P amplified, and then multiplied by multiplying by multiplying by a power switch to display the instrument header head, you can get three different number limits 0 2 0 20 0 200
Overview The Intelligent dielectric loss tester also applies to the measurement of tg and electrical capacity of high voltage electrical equipments in the workshops, laboratories and research institutes. It could measure non-grounded or grounded high voltage equipments adopting positive and negative connection method. Besides, it could measure the tg´ of capacitor voltage transformer and capacitance of main capacitor C1and C2. Main Specifications Control panel printer, keyboard, indicator and communication transferring. Variable frequency power supply SPWM switching circuit is adopted to generate and output high-power sine wave stable voltage. Step-up transformer the output of variable frequency power supply is stepped up to the measuring voltage. The maximum reactive power output is 2KVA one minute. Standard capacitor internal Cn. It is the measuring basis. Cn current detection it is used to detect the internal standard capacitor current, 10A 1A. The input resistance is
Our Digital Tablet Disintegration Apparatus is designed for accurate estimation of disintegration time of tablets as per IP/USP standards. Our Disintegration Test Apparatus is designed to test the two batches of six tablets, simultaneously.
Automatic capacitance and inductance tester is designed for the problems in the measurement of high voltage shunt capacitor banks in substation sites and refers to GB3983.2-1989 High Voltage Shunt Capacitors DLT840-2003 Technical Conditions for Use of High Voltage Shunt Capacitors and JB5346 1998 Series reactor and other national standards and specially developed mainly to measure the high voltage shunt capacitor bank and reactor of reactive power compensation device. Automatic capacitance and inductance tester adopts a new generation of high-speed hybrid microprocessor which is highly integrated synchronously collects the voltage signal and current signal of the test object and automatically calculates the capacitance value inductance value and reactive power value. On-site measurement of capacitors eliminates the need to remove the connecting lines simplifying the test process effectively improving work efficiency and avoiding damage to power equipment. After the test the capacity of each phase capacitor and other parameters are automatically calculated and it is easy to discriminate the quality change of the capacitor and the connection conductor failure between devices. At the same time the automatic capacitance and inductance tester also features data storage and USB communication eliminating the need to copy data on-site and ensuring complete measurement data.
Turning insert Milling inserts Grooving Tools Threading Tool DRILL Endmill Cutter Bandsaw Machine & Blade
The PACON 4800 Online Hardness Analyzer uses the principle of titrimetric colorimetry and is the best choice for water softening systems and reverse osmosis protection for enrey-level measurement.. Measurement Parameters Total Hardness Applications Demineralized water Reverse osmosis Boiler water Laundry room Groundwater Cooling tower Pharmaceutical water Process water Drinks / food Fully automatic measurement According to the selected reagent, automatically measure the total water hardness in different ranges. This analysis is more efficient than manual measurements and more reliable than other indirect measurement methods such as ion-selective electrodes. Smart & accurate & stable GB measurement method - Titration colorimetry method, the instrument has a calibration function. Integrated measurement techniques and two-stage analysis identify external influences such as trough contamination, watery turbidity and external light and eliminate these effects in the measurement. dimension is only 300x300x200mm, can be directly linked to the wall or mounted on the bracket. Minimum maintenance workload Complete isolation of water and testing device, detachable measuring cell, without the need for additional tools for maintenance, can be easily implemented. It is recommended to replace the spare parts package once a year (including: peristaltic pump head reagent tube, stirrer, seal, order number: 50-5000-10) Automatic cleaning Rinsing and Cleaning are performed automatically for each analysis, ensuring measurement accuracy, repeatability and reduced field maintenance. Low reagent consumption Reagent bottle can be easily replaced, 500ml reagent can measure 5000 ~ 10000 times. Reagents valid for 2 years. LCD backlight LCD display Multi-language graphics backlight LCD display measurements, reagent remaining, alarm values and relay status. 0 / 4-20mA output SD card data storage 2G data storage card, can be directly imported into the computer to excel format access to historical data and system failure information.
The PACON 4800 Online Hardness Analyzer uses the principle of titrimetric colorimetry and is the best choice for water softening systems and reverse osmosis protection for enrey-level measurement.. Measurement Parameters Total Hardness Applications Demineralized water Reverse osmosis Boiler water Laundry room Groundwater Cooling tower Pharmaceutical water Process water Drinks / food Fully automatic measurement According to the selected reagent, automatically measure the total water hardness in different ranges. This analysis is more efficient than manual measurements and more reliable than other indirect measurement methods such as ion-selective electrodes. Smart & accurate & stable GB measurement method - Titration calorimetry method, the instrument has a calibration function. Integrated measurement techniques and two-stage analysis identify external influences such as trough contamination, watery turbidity and external light and eliminate these effects in the measurement. A variety of measurement modes - Continuous measurement - Interval measurement (5-99min) - External switch signal initiates a measurement Compact design The dimension is only 300x300x200mm, can be directly linked to the wall or mounted on the bracket. Minimum maintenance workload Complete isolation of water and testing device, detachable measuring cell, without the need for additional tools for maintenance, can be easily implemented. It is recommended to replace the spare parts package once a year (including: peristaltic pump head reagent tube, stirrer, seal, order number: 50-5000-10) Automatic cleaning Rinsing and Cleaning are performed automatically for each analysis, ensuring measurement accuracy, repeatability and reduced field maintenance. Low reagent consumption Reagent bottle can be easily replaced, 500ml reagent can measure 5000 ~ 10000 times. Reagents valid for 2 years. LCD backlight LCD display Multi-language graphics backlight LCD display measurements, reagent remaining, alarm values and relay status. 0 / 4-20mA output SD card data storage 2G data storage card, can be directly imported into the computer to excel format access to historical data and system failure information.