Application :- The XLPE (Cross Link Poly Ethylene) Power Cables are used under ground as well as over head transmission of power in power plants, industries, projects and all other electrical installations. Features :- Manufactured from bright annealed 99.97% pure bare copper & aluminum conductors. These cables are insulated with XLPE compound. Taped/Extruded inner sheath. Round steel wire / flat galvanised steel grip armoured. The outer sheaths can be PVC, HR PVC, FRLS or FR depending upon the application and requirement. Technical Advantage of XLPE Insulation :- Higher current rating, higher short circuit rating (approx 1.2 times that of PVC), thermosetting in nature, higher insulation resistance (1000 times more than PVC cables), higher moisture resistance, better resistance to surge currents, low dielectric losses, better resistance to chemicals and corrosion, longer service life. Comparatively higher cable operating temperature 90�°C and short circuit temperature 250�°C. Technical Data :- Working Voltage : Up to 1100 V Temperature Range : -15�°C to +90�°C Power Cable Sizes : 1.50 Sq. mm to 400.00 Sq. mm in 2, 3, 3 Copper Control Cable Sizes : 1.50 Sq. mm, 2.50 Sq. mm up to 24 cores. Color Codes : 2 Core Cables - Red, Black 3 Core Cables - Red, Yellow & Blue 3 Core Cables - Red, Yellow, Blue & Black (for Neutral) 4 Core Cables - Red, Yellow, Blue & Black 5 Core Cables - Red, Yellow, Blue, Black & Grey 6 Core Cables & above - Adjacent cores are blue for reference and yellow for direction in each lay Black outer sheath Specification : IS:7098 (Part-1) Packing : 500 / 1000 meters on drums
XLPE Cable not only has excellent electric character, mechanical character, heat and aging-resistant character, environmental stress-resistant character and chemical corrosion- resistant character, but simple structure, light weight, no restriction by laying drop, and high temperature allowance for long-term working as well. We can produce according to GB Standard(China Standard) which is equivalent to the standard IEC60502.We can also design and manufacture special XLPE cable according to the other standards required by the clients. Drums
http://www.vericable.com/cables/powercable/xlpe-power-cable.htm
http://www.vericable.com/cables/powercable/xlpe-power-cable.htm
Http://www.Zmscable.Com/powercables/829.Html -
Http://www.Zmscable.Com/powercables/829.Html -
XLPE Power Cable
XLPE Power Cable.
Application: Xlpe power cable is used for power transmission and distribution line with voltage rated at 35kv and below.In comparison with pvc insulated power cable, xlpe power cable boasts not only characteristics of excellent electricity, mechanism, heat and aging-resistant, environment stress-resistant and chemical corrosion-resistant, but also simple structure, light weight, no restriction by laying drop, and high temperature allowance for long-term working. Xlpe power cable standard: A- iec 60502-1 Rated voltage 1 kv (umax=1.2kv) and 3 kv (umax=3.6kv) B- iec 60502-2 Rated voltage 6 kv (umax=7.2kv) to 30 kv (umax=36kv) C- voltage grade overstep iec60502 Rated voltage 35 kv (umax=40.5kv) Product description: - xlpe insulated pvc sheathed power cable (xlpe/pvc cable) - xlpe insulated steel tape armored pvc sheathed power cable (xlpe/sta/pvc cable) - xlpe insulated steel wire armored pvc sheathed power cable (xlpe/swa/pvc cable) - flame retardant xlpe insulated pvc sheathed power cable (fr/xlpe/pvc cable) - flame retardant xlpe insulated steel tape armored pvc sheathed power cable (fr/xlpe/sta/pvc cable) - flame retardant xlpe insulated steel wire armored pvc sheathed power cable (fr/xlpe/swa/pvc cable)
Application: Xlpe power cable is used for power transmission and distribution line with voltage rated at 35kv and below.In comparison with pvc insulated power cable, xlpe power cable boasts not only characteristics of excellent electricity, mechanism, heat and aging-resistant, environment stress-resistant and chemical corrosion-resistant, but also simple structure, light weight, no restriction by laying drop, and high temperature allowance for long-term working. Xlpe power cable standard: A- iec 60502-1 Rated voltage 1 kv (umax=1.2kv) and 3 kv (umax=3.6kv) B- iec 60502-2 Rated voltage 6 kv (umax=7.2kv) to 30 kv (umax=36kv) C- voltage grade overstep iec60502 Rated voltage 35 kv (umax=40.5kv) Product description: - xlpe insulated pvc sheathed power cable (xlpe/pvc cable) - xlpe insulated steel tape armored pvc sheathed power cable (xlpe/sta/pvc cable) - xlpe insulated steel wire armored pvc sheathed power cable (xlpe/swa/pvc cable) - flame retardant xlpe insulated pvc sheathed power cable (fr/xlpe/pvc cable) - flame retardant xlpe insulated steel tape armored pvc sheathed power cable (fr/xlpe/sta/pvc cable) - flame retardant xlpe insulated steel wire armored pvc sheathed power cable (fr/xlpe/swa/pvc cable)
Stranded circular compacted copper or aluminium conductors, XLPE insulated, copper tape screened, three cores assembled together with non-hygroscopic polypropylene fillers, covered with extruded bedding, armoured or unarmoured and PVC sheathed Cables comply with IEC 60502.
Specifications: 1) XLPE insulated / copper or aluminum / PVC sheathed or PE sheathed 2) XLPE insulated / copper or aluminum / steel tape armoured / PVC sheathed or PE sheathed 3) XLPE insulated / copper or aluminum / thin or thick steel wire armoured / PVC sheathed or PE sheathed Executive standard : 1)GB/T 12706.1-2002(Equivalent IEC60502-1) 2) GB/T 12706.2-2002(Equivalent IEC60502-2) 3) GB/T 12706.3-2002(Equivalent IEC60502-3) Drums
Cross Section 1000 SQMM. (Single Core), 630 SQMM (Multicore) Option : Conductor -Aluminium / Copper Armoured (Single / Double layer) / Unarmoured
XLPE Cable, PVC Cable, Copper Cable, ABC Cable, AAC and ACSR Conductors. Packed in various sizes/weight of wooden/steel drums.
XLPE Insulated Power cables We are supplying wide range of XLPE insulated power cables. It is important that while placing enquiries or orders, as much information as possible shall be given to us, so that the enquiries and orders are dealt quickly and efficiently. 1) Voltage Grade : 1.9 / 3.3 kV (E), 3.3 / 3.3 kV (UE), 3.8 / 6.6 kV (E) , 6.6 / 6.6 kV (UE), 6.35 / 11 kV (E), 11 / 11 kV (UE), 12.7 / 22 kV (E) & 33 kV (E), 33 kV (UE) , 45 kV & 66kV 2) Relevant Indian or International standard: IS 7098 (Part-2) 1985 or IEC-60502 (Part-2), BS-6622 & BS: 7835. 3) Number of cores:- Single & Three. 4) Conductor Size - 35 Sq.mm to 1000 Sq.mm in Single Core Cables & 35 Sq.mm to 400 Sq.mm in 3 Core cables. 5) Conductor Material: Copper / Aluminum 6) Type of Insulation: XLPE 7) Type of Inner Sheathing: PVC Wrapped / PVC Extruded. 8) Type of Armour: Unarmoured / Strip Armoured / Round Wire Armoured. 9) Type of Outer Sheath: PVC / Flame Retardant / Flame Retardant Low Smoke / Zero Halogen (LSOH). 10) Length of cable required per drum. Note: Detailed Leaflet for 66kV & above can be available on specific request
XLPE Insulated Power cables We are supplying wide range of XLPE insulated power cables. It is important that while placing enquiries or orders, as much information as possible shall be given to us, so that the enquiries and orders are dealt quickly and efficiently. 1) Voltage Grade : 1.9 / 3.3 kV (E), 3.3 / 3.3 kV (UE), 3.8 / 6.6 kV (E) , 6.6 / 6.6 kV (UE), 6.35 / 11 kV (E), 11 / 11 kV (UE), 12.7 / 22 kV (E) & 33 kV (E), 33 kV (UE) , 45 kV & 66kV 2) Relevant Indian or International standard: IS 7098 (Part-2) 1985 or IEC-60502 (Part-2), BS-6622 & BS: 7835. 3) Number of cores:- Single & Three. 4) Conductor Size - 35 Sq.mm to 1000 Sq.mm in Single Core Cables & 35 Sq.mm to 400 Sq.mm in 3 Core cables. 5) Conductor Material: Copper / Aluminum 6) Type of Insulation: XLPE 7) Type of Inner Sheathing: PVC Wrapped / PVC Extruded. 8) Type of Armour: Unarmoured / Strip Armoured / Round Wire Armoured. 9) Type of Outer Sheath: PVC / Flame Retardant / Flame Retardant Low Smoke / Zero Halogen (LSOH). 10) Length of cable required per drum. Note: Detailed Leaflet for 66kV & above can be available on specific request
â?¢ XLPE Insulated Power cables We are supplying wide range of XLPE insulated power cables. It is important that while placing enquiries or orders, as much information as possible shall be given to us, so that the enquiries and orders are dealt quickly and efficiently. 1) Voltage Grade : 1.9 / 3.3 kV (E), 3.3 / 3.3 kV (UE), 3.8 / 6.6 kV (E) , 6.6 / 6.6 kV (UE), 6.35 / 11 kV (E), 11 / 11 kV (UE), 12.7 / 22 kV (E) & 33 kV (E), 33 kV (UE) , 45 kV & 66kV 2) Relevant Indian or International standard: IS 7098 (Part-2) 1985 or IEC-60502 (Part-2), BS-6622 & BS: 7835. 3) Number of cores:- Single & Three. 4) Conductor Size - 35 Sq.mm to 1000 Sq.mm in Single Core Cables & 35 Sq.mm to 400 Sq.mm in 3 Core cables. 5) Conductor Material: Copper / Aluminum 6) Type of Insulation: XLPE 7) Type of Inner Sheathing: PVC Wrapped / PVC Extruded. 8) Type of Armour: Unarmoured / Strip Armoured / Round Wire Armoured. 9) Type of Outer Sheath: PVC / Flame Retardant / Flame Retardant Low Smoke / Zero Halogen (LSOH). 10) Length of cable required per drum. Note: Detailed Leaflet for 66kV & above can be available on specific request
XLPE Insulated Power Cable Brief introduction to XLPE insulated Power Cable Since the 1960â??s, China has made rapid progress in its XLPE cable, replacing the oil paper insulated power cable, because of its outstanding electricity property , good overload , high voltage , large transmission capacity , light weight and laying without drop limit, vertical laying, convenient installation and operation maintenance and other strong points , XLPE cable can not only be widely used in 35 KV and below medium and Low voltage Cable scope, but also largely used in 66, 110 and 220 KV high voltage transmission lines. And , in some developed industrial countries 500 KV super-high voltage XLPE cables have been opened up.. Product Standard Huiyou Cablefocus on Various Power Cables, Our High Voltage XLPE Cables are very popular, and Our factory cab also design and produce some XLPE Insulated Power Cable for special requirements according to clientsâ?? demand. if you are interested in our products, please contact us as soon as possible. Property for Use a.Max rated temperature of cable conductor is 90 b.For short circuit ( Maximum sustained time not exceeding 5s), maximum temperature of cable conductor not exceeding 250 Cable rated voltage selection : Cable rated voltage should be suitable to the system voltage and operation conditions of used cable, expressed by U0/U(Um), all are effective value, unit is KV .