170mv substation equipment International standard
High reliability: The SCR is installed in low voltage circuit, not in main circuit, so, the withstanding voltage is just 1% of main circuit voltage. Low harmonic contents: THD is below of 5%, which comply with related national criterion, if the multiple connections are adopted, the THD can be reduced below of 1.2%. Small dimension: the dimension of MCR is about 2/5 of TCR. It can be able to connect in high voltage power grid, the cost and floor space are reduced dramatically. Fast response time(100~300ms), it can fully meet the demand of dynamic reactive power compensation of power equipments. No need of cooling devices, which reduce the fault rate, maintenance cost and floor space. The advantage of MCR-typed SVC The MCR-typed SVC was based on traditional saturation reactor technology; it was put forward by Russia scientists. They introduced the concept of magnetic valve creatively to just make the small section of iron core saturation, which solved the high harmonic problems caused by traditional saturation reactor, because all iron cores in traditional saturation reactor are excessive saturation, then result in nonlinear harmonic. At the same time, the SVC of MCR type reduced the dimension, weight and noise of entire system; it has many advantages, such as: low harmonics, fast response time, high voltage withstanding level, stable operation, small floor space and long service life. Therefore, the SVC of MCR type is quickly spreading in Russia, Ukraine, America, India, China and other countries. It plays a very important role in improving power quality, decreasing reactive power loss, stabilizing power grid voltage and enhancing the reliability of power grid operation.Because MCR-typed SVC adopted advanced micro-electronics technology, it can regulate reactive power demand and compensation on bus bar accurately: The inductive reactive current in main circuit can be adjusted through changing low voltage DC to regulate main circuit impedance fast and smoothly, meanwhile, through cooperating with capacitor bank paralleled in bus bar, reactive power compensation demand can be realized on bus bar, and dynamic response and improved power factor can stabilize bus bar voltage. Choosing reactor parameters properly connected in series with capacitor bank, the compensation on fundamental wave can be obtained, and the harmonic also can be filtered. Because the SVC of MCR is free of frequent switching from mechanical parts, then it avoids surge and over-voltage impact caused by MSC, which enhances the reliability and the service life of the equipment, as well, protects the other instruments. The SVC of MCR type fully absorbed advantages and functions of TCR-typed SVC by comparison; it solved the problems of smooth regulation which can not be realized by MSC and TSC, and also overcome some disadvantages of TCR-typed SVC. Because the reactor is connected to high voltage main circuit directly in series, it must stand extra high voltage and ultra high voltage. At present, the highest voltage of reactor in our country reach to 1000KV, and the maximum capacity reach to 320MVar. The reactor also has over-load function; it will not generate big damage to system except heating, while, the thyristors in TCR-typed SVC is connected to high voltage circuit directly, the over-voltage will result in faults and break. So it is very stable for MCR-typed SVC to operate under the high voltage circuit with free of maintenance. Wooden case (Fumigation).
Principle APF is a new power electronic equipment which can dynamically filter harmonic with variable amplitude and frequency and compensate reactive power, it overcome the shortages of traditional LC filter and obtained the better compensation characteristics than passive filter. The following diagram is schematic diagram of APF, where, Vs is AC power supply, nonlinear load is harmonic source, it generates harmonic and consumes reactive power. APF is composed of instruction current operational circuit and compensation current generation circuit, the instruction current operational circuit is mainly to inspect current contents in harmonic current and reactive power of compensation object, and the compensation current generation circuit generates actual compensation current according to instruction current, the main circuit adopted PWM converter. Technical Features: Compensate any order harmonic with variable amplitude and frequency and different reactive power dynamically, and has a high-speed response time to the change of compensation object, it is hard to generate harmonic resonance with power grid impedance. It can implement compensation on single harmonic source and reactive power source and also implement centralized compensation on many harmonic and reactive power sources. Adopt full-bridge PWM converter to generate compensation current, the power unit is 5th generation IGBT, it is working under the high-frequency switching. Power circuit and control circuit adopted modularized structure or plug-in unit, same module can be replaced, which enhanced the reliability and maintenance. DSP high-speed checking and operation ensure harmonic checking and compensation control correct; It has intelligent supervisory control function, the working state and operation parameters are displayed in real-time, meanwhile, faults can be self-diagnosed; it also has remote communication interfaces, the real-time monitoring can be realized through PC. With perfect protection functions, the main circuit adopted three-phase three wire or three-phase four wire, it is designed to shunt APF, very easy and safe to operate. The master chip adopted latest floating-point DSP F28335 of TI Company and FPGA of ALTERA Company to make the system have powerful processing capacity, the sampling adopted AD7606 with 16 bits of AD Company to ensure control precision. APF can be used in power grid alone or can be combined with other passive filters together to realize hybrid filter with best ratio of performance to price. Application Fields: Static converters for industrial use, such as high and low voltage transducer (speed regulation), high capacity rectifier devices, etc. The DC equipment or transducer of the steel mill, high speed wire, boards and bars. Ferrous (non-ferrous) rolling (mill): Such as stainless steel rolling, carbon steel rolling, line rolling, aluminum sheet (strip, foil) rolling mill. Non-ferrous electrolysis industry: Electrolytic aluminum, copper, cadmium, cesium, etc. Rubber and plastic industry: Internal mixer, injection molding machine, extruding machine, blow molding machine etc Medium frequency induction heating furnace: Metal casting industry, steel mill hot rolling. Electrolysis of chemical plant: Electrolysis NaCl, electrolysis KCl, electrolysis H, et. Electroplating industry: Chroming, aluminizing and galvanizing in lighting factory, etc. Paper industry: Speed regulation used for craft, such as paper-pulp squeezer, etc Petrochemistry: During the technological process of chemical and oil refining, large amount of low voltage inverters used for speed regulation, and small amount of high voltage and high power electronic circuit equipments for starting, etc. DC traction equipment: Electrical railway, light rail vehicle, mine traction locomotive etc. Other high capacity industrial DC power supply. 2. AC/DC Arc Equipments AC/DC arc furnaces: Such as the Electric Arc Furnace in steel mill, etc. AC/DC arc welding machine: Automobile manufacturing, ship building, heavy machinery manufacturing, etc. 3. Power supply devices for special use High capacity uninterruptible power supply, communication power supply, high (low) frequency power supply, etc. Such as bank, hospital, semiconductor factory, program control exchange plant, remote communications, data communication station, substation, military installations, office buildings etc 4. Starting of the high capacity electromotor and switching of the high capacity reactive compensation. 5. High-precision automatic production line: The production line itself does not produce harmonic, but it is very sensitive to harmonic, so the active power filter should be installed at the side of power supply to reduce harmonic interference for production line. Wooden case (Fumigation).
1, Dmx512 decoder module. 2, 12v, 2a per loop. 3, can work with 12v led strip/led module/led bulb.
1, led dimmer. 2, 12v/24v. 3, 0-100% brightness adjustable
Aluminum anodes are widely used in vessel, ballast tank, crude oil tanks, seaport facilities, offshore project, submerged ducts, pipes in the soil, etc. Corrtech supplies series of aluminum anodes for defend the corrosion of steel structure in marine environment and fresh water. The performance of aluminum anodes is affected by the chemical composition of the alloy, we have different alloy series to meet customers' request. Special shape, size and chemical composition anodes can be manufactured according to your request. We can supply the several kinds of the anode such as al anode for tank interior bottom, welded al anode for hull and so on. The detailed information is listed as follows: 1. Al anode for tank interior bottom: 2. Welded al anode for hull (single iron stand) 3. Welded al anode for hull (double iron stands) 4. Bolt-on al anode for hull 5. Al anode for ballast 6. Al anode for marine engineering facilities 7. Al anode for port facilities 8. Al strip-type anode for seawater cooling system 9. Al discoid anode for seawater cooling system
The mixed metal oxide anode has an extremely low consumption rate, measured in terms of milligrams for ampere-year. Whether operating in soil, fresh water, and or sea water, mixed metal oxide coatings demonstrate very high chemical stability, even in environments with very low ph values. Corrtech supplies high performance mmo anodes suitable for soil, sea mud, seawater and fresh water environment. In seawater, the suggested working current density is 600 a/m2, and in fresh water is 100a/m. Products forms of mmo anode Mmo solid rod anode Mmo tubular anode Mmo ribbon anode Mmo mesh anode
1\standard potential magnesium anodes To be used in soils with resistivity lower than 2000 ª+/cm To minimize the cost. Be cheaper than high potential magnesium anodes Electrochemical properties 2\mg high potential anodes To be used in soils with resistivity more than 2000 ª+/cm As per astm b843 industry standard Electrochemical properties 3\mg extruded ribbon anodes
Power correction factor device corrects reactance losses from large inductive loads. Reverses reactance loss in power efficiency resulting in lower amperage requirements after lock rotaor current phase od staritng inductive loads. 9z9x7" boxed each unit, lot sizes dependent on rate of purchase and shipping requirements. Components are top of the line and product will operate in any electrical environment 120, 220 , 3 phase another unit. Savings range from 10- 40% depending on age of equipment. Equipment will run more efficiently and service requirements for equipment will be reduced significantly
United Machinery are manufacturers of Lathe Machines, Heavy Lathe Machine, Chill Roll Lathe Machines, Rolling Mill Lathe Machines, Lathe Machine Company India, Heavy Duty Lathe Machines, Long Lathe Machine, United Lathe Machine, Automatic Lathe Machine, Shaper Machines, Shaping Machinery, Power Presses, Milling Machines, Hacksaw Machines, Wood Turning Lathe, Wood Working Machine, Pipe Threading Machine, Drill Machines, Slotting Machine, Planner Machine, Tools and Cutting Grinder, Metal Shearing Machine, Centerless Grinder, Dog Chucks / True Chucks, Machine Tools C
United Machinery are manufacturers of Lathe Machines, Heavy Lathe Machine, Chill Roll Lathe Machines, Rolling Mill Lathe Machines, Lathe Machine Company India, Heavy Duty Lathe Machines, Long Lathe Machine, United Lathe Machine, Automatic Lathe Machine, Shaper Machines, Shaping Machinery, Power Presses, Milling Machines, Hacksaw Machines, Wood Turning Lathe, Wood Working Machine, Pipe Threading Machine, Drill Machines, Slotting Machine, Planner Machine, Tools and Cutting Grinder, Metal Shearing Machine, Centerless Grinder, Dog Chucks / True Chucks, Machine Tools Company, Lathe Machinery, manufacturer exporters distributors suppliers from india, ludhiana punjab, usa, uk, America, UAE
United Machinery are manufacturers of Lathe Machines, Heavy Lathe Machine, Chill Roll Lathe Machines, Rolling Mill Lathe Machines, Lathe Machine Company India, Heavy Duty Lathe Machines, Long Lathe Machine, United Lathe Machine, Automatic Lathe Machine, Shaper Machines, Shaping Machinery, Power Presses, Milling Machines, Hacksaw Machines, Wood Turning Lathe, Wood Working Machine, Pipe Threading Machine, Drill Machines, Slotting Machine, Planner Machine, Tools and Cutting Grinder, Metal Shearing Machine, Centerless Grinder, Dog Chucks / True Chucks, Machine Tools
United Machinery are manufacturers of Lathe Machines, Heavy Lathe Machine, Chill Roll Lathe Machines, Rolling Mill Lathe Machines, Lathe Machine Company India, Heavy Duty Lathe Machines, Long Lathe Machine, United Lathe Machine, Automatic Lathe Machine, Shaper Machines, Shaping Machinery, Power Presses, Milling Machines, Hacksaw Machines, Wood Turning Lathe, Wood Working Machine, Pipe Threading Machine, Drill Machines, Slotting Machine, Planner Machine, Tools and Cutting Grinder, Metal Shearing Machine, Centerless Grinder, Dog Chucks / True Chucks, Machine Tools Company, Lathe Machinery, manufacturer exporters distributors suppliers from india, ludhiana punjab, usa, uk, America, UAE
United Machinery are manufacturers of Lathe Machines, Heavy Lathe Machine, Chill Roll Lathe Machines, Rolling Mill Lathe Machines, Lathe Machine Company India, Heavy Duty Lathe Machines, Long Lathe Machine, United Lathe Machine, Automatic Lathe Machine, Shaper Machines, Shaping Machinery, Power Presses, Milling Machines, Hacksaw Machines, Wood Turning Lathe, Wood Working Machine, Pipe Threading Machine, Drill Machines, Slotting Machine, Planner Machine,
High Voltage Insulator for power equipment
Power conditioning equipments.
Power correction factor devices.
Mainly power equipments and accessories.
Substation equipment in power transmission equipment.Project turnkey basis
Turbine, Boiler, Avtomatic.