Product Characteristic
Model: Model Y5-48 Boiler Centrifugal Induced Draft Fan
Flow:2065-67803m3/min
Shaft power:2.2-110KW
Pressure:742-4483Pa
Port Dia:355-1120A mm
Rotating Speed:1000-3550r/min
Product Introduction
Model Y5-48 boiler centrifugal induced draft fan is designed for industrial boiler (1~20T/h) which burns all kinds of coal and is equipped with dust removal device.It is suitable for anywhere with appropriate intake condition and corresponding performance,but the maximum temperature should not exceed 250ºC.
In front of induced draft fan,it must set a dust elimination device to reduce the dust content of the smoke gas into the fan.According to the general usage of power plant,the dust elimination efficiency is not less than 85%.
In consideration of economy of the fan, triangle belt(C type)transmission is adopted,which can not only meet the requirement of the same tonnage boiler configuration of all kinds of dust remover with different rotating speed of one machine number, but also reduce the fan series and machine number.And It is convenient for user according to the actual situation, to choose different rotating speed to obtain the required and more ideal flow as well as pressure.
Y5-47 series fan has a lower noise compared with previous Y5-47 because of a series of improvements, in order to meet the requirement of supporting boiler, 4D, 5D, 6D, 7D, 10D, 11D, 12D, 12.4D these eight models were newly added. They are suitable for various burning coal and industrial boiler equipped with smoke-eliminated and dust-removed device. All can be adopted when the inlet condition are suitable, performance adaptable with max temperature not exceed 200â??.
Y5-48 series boiler centrifugal induced draft fan is designed to adapt to industrial boiler that various coal burning and with the installation of smoke prevention and dust control device, if all air inlet conditions is good and performance, is adapt, this machine can be used. In order to lower the fan flue gas dust content and improve the life of fan, the highest temperature should not exceed 250â??, dust and hard particles contained is no more than 150g/m3.
POPULA Fan Centrifugal Heat Dissipation Y5-48C Boiler Centrifugal Induced Draft Fan
Product Introduction:
It is designed to fit the equipment of 1-20t/h industries boiler and civil boiler of which equipped with the dust-removal fixture.Before installation , the fan must equip with the dust-removal fixture whose dust removing efficiency shall not beneath 85% . The temperature of air must be below 250 Our company can provide the stainless steel heat boiler centrifugal blower , when the temperature of air must exceed 250
PRODUCTS INFO:
Type:POPULA Boiler centrifugal induced draft fan Y5-48
Brand:POPULA
Electric Current:AC
Power:3-110 KW
Voltage:1HP/3HP 110V/220V/380V/440V/3KV/6KV
Frequency: 50/60HZ
Air Volume:2065~67803 CMH
Air Pressure:1097-4483 Pa
Speed:1000-3550 rpm
Max Noise:
G/Y6-41 series boiler centrifugal induced draft fan are featured with low noise, high performance, smooth operation of transmission group, high reliability and high institutions operating life.
Suitable for various coal-fired industrial boilers equipped with smoke and dust removal apparatus drum/induced draft fan system, drum fan transport medium is air, the maximum temperature does not exceed 80â??, induced draft fan transport medium is flue gas, the maximum temperature not exceed 250â??. Dust removal device must be installed in front of this fan to minimize flue gas dust contents.
PRE ORDER / PRODUCTION
FOB Thailand ( Laem Chabang Port )
KC 500;
Nitrile Examination Gloves
MOQ: 5 Million x 12 months
MAX: 20M x 12 months
Price USD8.00
KimTech;
Nitrile Examination Gloves
MOQ: 5 Million x 12 months
MAX: 20M x 12 months
Price USD8.20
*Including USD0.10 commission for buyer side
*Sea Freight USD0.35 - USD0.50 CIF
Payment terms :
1. SBLC as Warranty, amounting Half Value of First Month Delivery and or
2. Irrevocable Revolving Non Transferable Divisible LC with withdrawal % from the LC as deposit from the total amount of 1 month.
Standing Operative Procedure;
1. NCNDA via Docusign
2. Buyer issues LOI, ICPO, LOA (if Proxy) and Proof Of Fund (*via Ready Willing Able or RWA Letter from the Buyer's Bank) for Fund verification, KYC
3. Within 24 to 48 hours of receiving the above Documents after verification, Buyer will be provided with a Draft Sales Purchase Agreement and LC Draft
4. Once the Buyer has reviewed the SPA, the Buyer and Seller will sign SPA - IMFPA.
5. Allocation Letter @ Authorization Letter will be provided thru the Zoom Meeting
6. Seller provides PI
7. Within 3 working days after the contract assigned, Buyer activate Letter of Credit @ Irrevocable Revolving Non Transferable Divisible LC to Seller with the following terms
As Note given accordingly
2.5% - 10% payment withdrawn from the IRTLC for the deposit against Confirmation Letter from Factory and Invoice from Seller from the total amount of 1 month
90% - 97.5% will be withdrawn upon completion of SGS and ready for shipment for the First Month and 100% subsequently
(to be confirmed by issuing bank) or value including the full purchase price plus the 2.5% - 10% one month sales for Deposit
8. PRODUCTION START
9. Seller provide delivery schedule from Factory within 10 - 15 working days after receipt of LC. If not Seller pay penalty 2.5% of 1 Month of Sales
10. Buyer provide SGS Inspection details to Seller to get approval from Factory for the Inspection
11. SGS is completed at the factory warehouse and after receive full payment the goods release from the Warehouse.
12. Seller released original documents to Buyer : Certificate of Origin, Packing List, Pro Forma Invoice
13. The Seller is responsible for the goods until they are loaded on a shipping vessel of which point all liability, risks, insurance and costs shifted to the buyer
POPULA Fan C6-48C Dust Removal Centrifugal Fan Industrial Exhaust Fan
It is suitable to expel air with dirt , wood scraps and fine fiber . It can also be used for ventilation with the temperature of air below 80â?? There are A motor directly driven type , C belt driven type and D drive type with coupling , users can choose from different driven types according to their needs .
PRODUCTS INFO:
Type:POPULA dust removal centrifugal fan C6-48 C
Brand:POPULA
Electric Current:AC
Power:0.75-37 KW
Voltage:1HP/3HP 110V/220V/380V/440V/3KV/6KV
Frequency: 50/60HZ
Air Volume:755~56902 CMH
Air Pressure:344-2043 Pa
Speed:500-3150 rpm
Max Noise:
POPULA Fan Steam Boiler Induced Draft Y9-38D Boiler Centrifugal Induced Draft Fan
Product Introduction:
It is designed to fit the equipment of 0.5-35t industries boiler which equipped with preheated and dust-removal fixture , suitable for the industrial boiler with the similar suction condition and the compatible performance . But the temperature of air must be below 250â??. Before installation . the fan must equip with the dust-removal fixture whose dust removing efficiency shall not beneath 85% .With access 1o lower the amount of dust in the flue gas,the far will reduce environmental pollution .Moreover , it can reduce wear so as to enhance the service life of the fan.
PRODUCTS INFO:
Type:POPULA Boiler centrifugal induced draft fan Y9-38
Brand:POPULA
Electric Current:AC
Power:5.5~315 KW
Voltage:1HP/3HP 110V/220V/380V/440V/3KV/6KV
Frequency: 50/60HZ
Air Volume:3297~139712 CMH
Air Pressure:1402~5805 Pa
Speed:730-2900 rpm
Max Noise:
C6-48 dust exhausting centrifugal ventilator fan is used for discharging air mixture, which include wood debris, fiber and dust. This fan adopt the working principle of centrifugal fan, it has many features such as large volume, high pressure, war resistance, long serve life, etc. It is very popular for dirt customers. If discharge hard particles, it must add dust-cleaning device in the front of inlet.
Monoblock pumps -
Falcon centrifugal monoblock pumpsets are powered by a totally enclosed fan cooled AC induction two pole motor. Motor stator is made of low watt loss silicon steel laminations assembled under pressure and rigidly locked in the
frame. The windings are of high-grade enameled copper wire offer excellent resistance and are varnish impregnated. Construction of motor frame and usage of quality materials result in high performance and low temperature rise
thereby increasing the life cycle of the motor.
salient features
- High operating efficiency resulting in lower power consumption
- Good suction lift characteristics
- Inbuilt thermal overload protector in al single phase pumpsets upto 2.0 HP
- Specially designed for wide voltage operation
- Dynamically balanced rotating parts including rotor and impeller ensures minimum vibration and longer life
- Back pull-out design for easy servicing and repair
- Double shielded ball bearings, so no need of external lubrication
- All Model fitted to Mechanical seal.
specification
- Power Range : 0.37Kw - 1.5 Kw (0.5 HP - 2.0 HP)
- Version : Single Phase, 220-240V, 50Hz AC Supply
Three Phase, 380-415V, 50Hz AC Supply
- Speed : 2880 RPM
- Maximum Total Head : 32 Mtr.
- Maximum Flow Rate : 940 LPM
- Maximum Suction Lift : 7 Mtr.
- Degree of Protection : IP 44
- Class of Insulation : B0
- Maximum Ambient Tem. : 40 C
- Sealing : Mechanical Seal
- Type of Duty : S1 (Continuous)
- Method of Starting : Permanent Split Capacitor (PSC)
- Direction of Rotation : Three Phase, Electrically Reversible
- Nominal Pumpset Size (Suction X Delivery in inch) : 25 X 25, 32 X 25, 40 X 32, 40 X 40, 50 X 40,
50 X 50, 65 X 50, 80 X 65, 80 X 80 (All size in mm)
characteristics of clear cold water
- Maximum liquid temperature : 33C max
- Permissible amount of sand : 25 g/m
- Allowable solids : 3000 ppm (max.)
- Chloride ion density : 500 ppm (max.)
- Turbidity : 50 ppm silica scale (max.)
- Hardness (Drinking Water) : 300 ppm (max.)
- Specific gravity : 1.004 (max.) 6
- Viscosity : 1.75 x 10 m/sec (max.)
- Ph Value : 6.5 to 8.5
Part Name Material
Mechanical Seal : Carbon & Ceramic
Motor Shaft : EN-8
Motor Body : FG-250
Bearing : SKF
End Cover : FG-250
Bracket : FG-250
Flange : FG-250
Casing : FG-250
Impeller : FG-250
Cooling Fan : Plastic
Monoblock Pumps
Falcon centrifugal monoblock pumpsets are powered by a totally enclosed fan cooled AC induction two pole motor. Motor stator is made of low watt loss silicon steel laminations assembled under pressure and rigidly locked in the
frame. The windings are of high-grade enameled copper wire offer excellent resistance and are varnish impregnated. Construction of motor frame and usage of quality materials result in high performance and low temperature rise
thereby increasing the life cycle of the motor.
salient features
High operating efficiency resulting in lower power consumption
- Good suction lift characteristics
- Specially designed for wide voltage operation.
- Dynamically balanced rotating parts including rotor and impeller ensures minimum vibration and longer life.
- Back pull-out design for easy servicing and repair.
- Double shielded ball bearings, so no need of external lubrication.
- Mechanical seal is provided as per customers requirement
Specification
- Power Range : 2.2 Kw - 11.2 Kw (3.0 HP - 15.0 HP)
- Version : Three Phase, 380-415V, 50Hz AC Supply
- Speed : 2880 RPM
- Maximum Total Head : 65 Mtr.
- Maximum Flow Rate : 1450 LPM
- Maximum Suction Lift : 7 Mtr.
- Degree of Protection : IP 44
- Class of Insulation : B0
- Maximum Ambient Tem. : 40 C
- Sealing : Stuffing Box
- Type of Duty : S1 (Continuous)
- Direction of Rotation : Three Phase, Electrically Reversible
- Nominal Pumpset Size (Suction X Delivery in inch) : 50 X 40, 50 X 50, 65 X 50, 80 X 65, 80 X 80
100 X 80 and 100 X 100 (All size in mm)
Characteristics Of Clear Cold Water
- Maximum liquid temperature : 33C max
- Permissible amount of sand : 25 g/m
- Allowable solids : 3000 ppm (max.)
- Chloride ion density : 500 ppm (max.)
- Turbidity : 50 ppm silica scale (max.)
- Hardness (Drinking Water) : 300 ppm (max.)
- Specific gravity : 1.004 (max.) 6
- Viscosity : 1.75 x 10 mÃ?/sec (max.)
- Ph Value : 6.5 to 8.5
Material of construction - motor
Part Name Material
Gland Dori : Graphite String
Motor Shaft : EN-19 with SS SLEEVE
Motor Body : FG-250
Bearing : SKF
End Cover : FG-250
Bracket : FG-250
Flange : FG-250
Casing : FG-250
Impeller : FG-250
Cooling Fan : Aluminium
Monoblock pumps
Falcon centrifugal monoblock pumpsets are powered by a totally enclosed fan cooled AC induction two pole motor. Motor stator is made of low watt loss silicon steel laminations assembled under pressure and rigidly locked in the
frame. The windings are of high-grade enameled copper wire offer excellent resistance and are varnish impregnated. Construction of motor frame and usage of quality materials result in high performance and low temperature rise
thereby increasing the life cycle of the motor.
Salient Features
High operating efficiency resulting in lower power consumption.
- Good suction lift characteristics.
- Specially designed for wide voltage operation.
- Dynamically balanced rotating parts including rotor and impeller ensures minimum vibration and longer life.
- Back pull-out design for easy servicing and repair.
- Double shielded ball bearings, so no need of external lubrication.
specification
- Power Range : 1.5 Kw - 5.5 Kw (2.0 HP - 7.5 HP)
- Version : Three Phase, 380-415V, 50Hz AC Supply
- Speed : 1440 RPM
- Maximum Total Head : 12 Mtr.
- Maximum Flow Rate : 3160 LPM
- Maximum Suction Lift : 7 Mtr.
- Degree of Protection : IP 44
- Class of Insulation : B0
- Maximum Ambient Tem. : 40 C
- Sealing : Stuffing Box
- Type of Duty : S1 (Continuous)
- Direction of Rotation : Three Phase - Electrically Reversible
- Nominal Pumpset Size (Suction X Delivery in inch) : 80 X 80, 100 X 100, 125 X 125, 150 X 150
(All size in mm)
Characteristics Of Clear Cold Water
- Maximum liquid temperature : 33C max
- Permissible amount of sand : 25 g/m
- Allowable solids : 3000 ppm (max.)
- Chloride ion density : 500 ppm (max.)
- Turbidity : 50 ppm silica scale (max.)
- Hardness (Drinking Water) : 300 ppm (max.)
- Specific gravity : 1.004 (max.) 6
- Viscosity : 1.75 x 10 m/sec (max.)
- Ph Value : 6.5 to 8.5
Part Name Material
Gland Dori : Graphite String
Motor Shaft : EN-19 with SS SLEEVE
Motor Body : FG-250
Bearing : SKF
End Cover : FG-250
Bracket : FG-250
Flange : FG-250
Casing : FG-250
Impeller : FG-250
Cooling Fan : Aluminum
G/Y4-73 series boiler centrifugal is suitable for 2-670T/h steam boiler in the thermal power plant. If no special requirements, G4-73 is also used for mine ventilation and general ventilation, ventilation fan is delivering air, the highest temperature does not exceed 80. Induced draft fan is delivering flue gas, and the highest temperature does not exceed 250. Dust removal device must be installed in front of the induced draft fan, according to the use of the general power plant, the dust and hard particles is 150g/m3. Design temperature of G4-73 is 20, design temperature of Y4-73 is 140.
We can design and manufacture G/Y4-73series with Â
1.Corrosion-proof,high temperature fan
2.Overall damping bracket fan
Technical Data
STRONBULL Industrial Boiler Centrifugal Fan Y9-38 high pressure high temperature Induced Draft fan
PRODUCTS INFO:
Type:STRONBULL Industrial Boiler Centrifugal Fan Y9-38
Brand:STRONBULL
Electric Current:AC
Power:5.5-280 kw
Voltage:1HP/3HP 110V/220V/380V/440V/3KV/6KV
Frequency: 50/60HZ
Air Volume:3297 -139712M3/h
Air Pressure:1402 - 5805 Pa
Speed:960r/min ,1450r/min,2960r/min
Max Noise:
Virgin coconut oil (VCO) can be produced from fresh coconut meat, milk, or residue. Producing it from the fresh meat involves removing the shell and washing, then either wet-milling or drying the residue, and using a screw press to extract the oil. VCO can also be extracted from fresh meat by grating and drying it to a moisture content of 10–12%, then using a manual press to extract the oil. Producing it from coconut milk involves grating the coconut and mixing it with water, then squeezing out the oil. The milk can also be fermented for 36–48 hours, the oil removed, and the cream heated to remove any remaining oil. A third option involves using a centrifuge to separate the oil from the other liquids. Virgin coconut oil looks slightly different from ordinary coconut oil and this differentiation cannot be made with the naked eye. This difference is mainly due to the presence of certain colloidal and other particles and moisture within it. On the other hand, ordinary oil is refined and is mainly left with the fatty acids in it and almost nothing else. Ideally, virgin coconut oil should be as clear as water. However, its color may vary slightly depending upon its processing. Virgin coconut oil has a very good taste and smell, like that of fresh coconuts, since it is derived from fresh coconuts and is subjected to very low, if not totally nil, heat and sunlight. It is also not refined. This preserves all the natural goodness of this oil, including a high content of vitamin-E and minerals, which are otherwise almost completely robbed from ordinary coconut oil during processes like heating, filtration, refining, and bleaching, which are done to make it colorless and odorless. Furthermore, virgin coconut oil is very effective as a moisturizing agent. Its antioxidant properties are far better than those of normal coconut oil.
Product Description
high-temperature fans are generally used in Kaji furnace,High-pressure forced ventilation and the transport for meterials ,wind and Non-corrosive,Not spontaneous,Non-explosive,Gluten-free gas.
About Product Feature:High efficiency,low noise,easy operation ;Adjustable blades
high-temperature fans are generally used in Kaji furnace,High-pressure forced ventilation and the transport for meterials ,wind and Non-corrosive,Not spontaneous,Non-explosive,Gluten-free gas.
Zibo Dingxian Mechanical Equipment Co.,Ltd which was founded in 1985, mainly designs and manufactures Centrifugal fans and Axial flow fans which are applied to industrial systems, which is the senior member of China General Machinery Industry Association (CGMA).
As one of the main large fan manufacturers in North China, which owns more than 200 employees and the production capacity of 15000 sets one year, we have an advanced Air flow Test Laboratory in our company. We master mature fan designing, testing, manufacturing technology, and can design and manufacture multipurpose fans according to users' requirements. So, we are able to meet users' complex and professional applications.
1564 Y5 48 Boiler Centrifugal Induced Draft Fan Suppliers
Short on time? Let Y5 48 Boiler Centrifugal Induced Draft Fan sellers contact you.