Power Transformers Range: 2500 kVA to 100,000 kVA, up to 220 kV Class Standards: The power transformers are designed and tested to the following standards: Power transformers: IS: 2026, BS: 171 & IEC: 76 Converter transformers: IS: 4540, IEC: 146 & IEEE: 444 Furnace transformers: IS: 2026 System earthing transformers: IS: 3150 & BS: 4944 We are capable in supplying the transformers to any other standards as per customers'/consultants' requirements.
â?¢ Power Transformers Range: 2500 kVA to 100,000 kVA, up to 220 kV Class Standards: The power transformers are designed and tested to the following standards: Power transformers: IS: 2026, BS: 171 & IEC: 76 Converter transformers: IS: 4540, IEC: 146 & IEEE: 444 Furnace transformers: IS: 2026 System earthing transformers: IS: 3150 & BS: 4944 We are capable in supplying the transformers to any other standards as per customers'/consultants' requirements.
1.Low leakage flux 2.Low hum noise 3.High efficiency 4.Light weight
We are instrumental in trading and supplying an exclusive assortment of Power Transformers. These transformers are procured from some of the trustworthy and certified vendors of the industry who manufacture these in compliance with the international standards. Our offered transformers are used extensively in electronic products to step down the supply voltage to a level suitable for the low voltage circuits they contain. This range also electrically isolates the end user from contact with the supply voltage. Specifications: Power transformers from 1 MVA to 50 MVA up to 220KV Class As per mutual discussion
Customized sizes are accepted Small, medium, and high quantity available Wide frequency range Please send universal purpose Low no-load losses Low mechanical hum Low stray magnetic field Low operating temperature Low height Easy to mount Ranges from 10 to 12,000VA Mainly designed for: Audio equipment ;Medical use ;Power sources ;Lighting purpose ;General purpose applications and security ;custom-made according to customerÆs specifications
Power transformer We have various torodial power transformers available, from 5va to 20kva. We accept both oem and odm business, with no minimum order quantity required. Delivery schedule is 7-28 days, depending on quantity, and design time is included. The size (outer diameter) of our power transformers range from 50mm to 360mm, with height from 40mm to 215mm. Our products have obtained the certificates including iso9001, cesi, ce and rohs. And we are trying to get the certification of ul. Please don't hesitate to contact us for further information. We always welcome you at any time. According toproducts
Power transformer Transformer working for medium frequency induction furnace, electric arc furnace, continuous casting machine, rolling mill steel plant. 220kV, 110kV and 66kV low loss series transformers; products with reliable performance, low partial discharge, low loss, low noise, high reliability, and strong resistance to sudden short circuit, its excellent performance has won the majority of users and related Experts highly praise. Partial discharge: at 1.5 times the rated voltage, the apparent discharge of the product is less than 80pC; Noise: Product noise of 63MVA and below is below 58dB (AN); Loss: No-load loss is about 30% lower than the IEC standard; Reliability: All in-service products have no damage accidents and oil leakage; Short-circuit resistance: SFZ11-50000 / 132 has passed the short-term ability test of the Netherlands KEMA and the National Transformer Quality Supervision and Inspection Center laboratory. Passed CE, UL, CSA, ROSH certification Coil: A All coils are made of 100% oxygen-free copper, and high-voltage coils are tangled. Continuous structure, in order to improve the distribution characteristics under impulse voltage, to obtain a more uniform electric field distribution, the bracing pads are rounded to improve the high reliability of insulation. A Iron core: The core material is high-quality cold-rolled silicon steel sheet with high magnetic grain orientation, and adopts advanced German Georg automatic shearing line to control the burr of the cutting mouth to be less than 0.02 mm. The silicon steel sheet adopts the technology of not stacking the iron yoke. The joint of the silicon steel sheet is a 45 �° full oblique stepped joint. After the iron chip is stacked, the overall pressure and epoxy glue are used to make the iron core three-pillar two yoke become a strong , Flat, high vertical accuracy, effectively improve the no-load performance, while reducing noise. Between the iron core column and the inner coil, the iron core column is supported by a brace plate, the iron yoke is tensioned by a glass ribbon impregnated with epoxy resin, and the lower iron yoke and the lower fuel tank are topped by a back pressure nail bolt. In addition, the upper iron yoke and the upper fuel tank are fixed in three places, so the body can withstand the bumps during transportation without displacement in the fuel tank.
product description S13-M oil-immersed distribution transformers for the distribution network and industrial and mining enterprises in the power supply and distribution system in the important equipment Transformer in the industrial and mining enterprises in various regions of the country, agriculture and civil construction can also be used in petroleum, chemical industry, Multi-chemical substances. Capacity in the 630 ~ 2000kvA range of low-voltage windings with cylindrical or spiral structure, high mechanical strength, ampere-turn distribution balance, the product of good short-circuit resistance. S13-M oil-immersed transformer body to add the positioning structure, so that in the transport process does not produce displacement, and all fasteners with fastening nuts to ensure that products in the long run is not loose during the fasteners to meet the Not hanging core requirements. S13-M oil-immersed transformer uses a corrugated oil tank, cancel the oil conservator, cover and box along the complete death or bolt fastening, extending the service life of transformer oil. S13-M oil-immersed transformer surface to the oil, to embroidery, phosphate coating after spraying primer, topcoat, to meet the metallurgical, petrochemical and wet pollution areas of special use requirements. Selection of components, using a sealed transformer tank, according to standard requirements to install a pressure relief valve, signal thermometer, gas relays, etc., to ensure the safe operation of the transformer. The series of products beautiful shape, small size, can reduce the installation area, is the ideal maintenance-free high-quality products.
Applicable Standards: IS, IEC, ANSI, JIS, BS, DIN, ETC. TRANSFORMER OPTIONS: Cooling Tubes / Radiators / Corrugated Tanks Pole Mounted / Ground Mounted Free Breathing / Hermetically Sealed CSP / Non CSP Winding-Copper/Aluminium (Foil / Rectangular Wire / Round Wire) Fittings and Accessories, Cable Terminations etc.as required Standards: MUSKAAN’S transformers are designed and tested as per IS : 2026, BS - 171, IEC - 76 & IEC - 726. Vector Group: Transformers will be connected as per vector group reference Dyn11. Other vector groups can be offered as per specific requirements Terminal Arrangement: H. V. - Bare Bushings or Cable Box, L. V. - bare bushings or cable box. Disconnecting chambers can also be provided on both HV and LV Cable boxes. Temperature Rise MUSKAAN’S transformers are designed for a maximum temperature rise of 40 / 50 degree C of oil / winding. Lower temperature rise can be offered on request. Other Information Minimum Order Quantity: 1 Unit(s)
Applicable Standards: IS, IEC, ANSI, JIS, BS, DIN, ETC. TRANSFORMER OPTIONS: Cooling Tubes / Radiators / Corrugated Tanks Pole Mounted / Ground Mounted Free Breathing / Hermetically Sealed CSP / Non CSP Winding-Copper/Aluminium (Foil / Rectangular Wire / Round Wire) Fittings and Accessories, Cable Terminations etc.as required Standards: MUSKAAN’S transformers are designed and tested as per IS : 2026, BS - 171, IEC - 76 & IEC - 726. Vector Group: Transformers will be connected as per vector group reference Dyn11. Other vector groups can be offered as per specific requirements Terminal Arrangement: H. V. - Bare Bushings or Cable Box, L. V. - bare bushings or cable box. Disconnecting chambers can also be provided on both HV and LV Cable boxes. Temperature Rise MUSKAAN’S transformers are designed for a maximum temperature rise of 40 / 50 degree C of oil / winding. Lower temperature rise can be offered on request. Other Information Minimum Order Quantity: 1 Unit(s)
If the secondary voltage of the Transformer is a high voltage, it is called as Power Transformer. Makpower supplies power transformers which transform energy from higher voltage levels and to distribute this energy to lower voltage substations or directly to large industrial consumers.
This static piece of apparatus improves efficiency and also reduces losses during run time. We provide best in class Power transformer which range from 33 KV to 200 KV voltage class and average rating starts from 200MVA onwards. We strictly adhere to international standards and certifications backed with GMP and best in class service provider.
Transformer up to 33 kv & 10 mva ratings Depending on customers requirement
It is based upon advanced technologies introduced from abroad and the successful experiences of leading manufacturers both domestic and abroad. It conforms entirely with up-to-date National Standard GB1094.1~2-1996¡ê¬GB1094.3-2003 GB1094.5-2003 and International Standard IEC76 commended by international electrical engin- eering committee, and are proud of the following outstanding features: 1. Low loss, and significantly energy-saving. The average no-load loss is 35% lower than prescribed by National Standard GB/T 6451-2008. 2. The core laminations are made up from high-quality cold-rolled grain-oriented silicon steel sheets with chamfered joints and without punched holes, and are stacked without the upper yoke sheets in place, so that they are effectively improved no-load upper together with lower frame. 3. Zigzag directed flow of oil are provided within the windings, so that all parts of the windings can be cooled more evenly. 4. The regulating winding is a separate winding which apart from the high voltage main winding. In this way, total ampere-turn balance between windings ; and the axial electrodynamic force during short circuit can be reduced, thus upgrading the short circuit withstand capability of the transformer as a whole. 5. The windings of one phase are assembled into an integral phase block before placing into the core. 6. The winding manufacture, winding assembly core and winding assembly work are all proceed in totally closed clean department. 7. Core frames in the form of a flat plate are used for clamping the core, and are joined together by side beams. The core and coil assembly is fixed in the tank, being positioned against the tank at six sides rigidly, so that there can be no displacement of the assembly due to impacts during transport. 8. Transformer tanks are fabricated with steel plates wide enough so that there are no weld joints on each surface. The steel plates for tank walls are pressed into corrugated shape to increase mechanical strength and to reduce noise due to vibration of the tank wall. 9. Diaphragm membrane is provided within the conservator, preventing direct contact of oil with air, protecting the oil from aging, thereby prolonging the service life of oil. Magnetic oil-level gauge reflects correctly the oil level in conservator. Flat plate-type radiator can effectively cool down the transformer. 10. Reliably sealed, and fine machined for sealed surface. Used double gasket grooves in their jointing surface and kept tight with high quality gasket material. If required by the customer, the upper and lower part of the tank can also be welded tight. 11. High quality paint is applied as surface finish of the tank and exposed steel parts, after shot-blasting and pretreatment, thus ensuring a durable life and glossy surface. 12. Quality assurance rules are also observed for all insulating parts, from raw material to final assembly. Strict regulations are observed for drying, wrapping and storage, preventing the absorption of moisture, swelling, and deformation. 13. Main components Because of good relationship and long-term co-corporation with all well-known sub-suppliers, we can meet the requirements of customers with whatever types of components they wish to have. fumigation wooden case
Our company absorbed advanced technology from home and abord, combined with international and domestic famous manufacturer¡¡¥s advanced technology and experienced manufacturing skills for many years, through the optimization of innovative, successfully produce low-noise, low loss, low partial discharge, high withstand short circuit ability series transformer. In according with latest national safety standard gb1094.1-2-1996, gb1094.3-2003, gb1094.5-2008 and the international electro-technical commission standard iec-76, the main structure features are as follows: 1.Shell-type tank, and a fully folded plate structure, elegant appearance. 2.The core with chamfered joints, non-porous, non-stacked on the iron yoke technology, scientific and rational control of core clamping force, reduce the core losses and electromagnetic noise. 3.Full range location of core and tank, ensure shock resistance during transportation. 4.Advanced and reliable electrical calculation procedures, quantitative analysis of coil positioning the magnetic field distribution, the distribution of oil flow and leakage magnetic field distribution, to ensure adequate electrical strength and low loss, and effective inhibition the partial overheating. 5.The body of transformer adopt multi-coil total assembly, constant drying measures to ensure the coils less rebound and uniform contraction, effectively improving the transformer ability to withstand short circuit. 6.The core and coil internal diameter side adopt strengthen hard paper tube to achieve no gap structure between core and the coil, enhance the strength to withstand short-circuit of coil. Fumigation wooden case
Our company provide 330kV oil-immersed power transformer ,with capacity of 360MVA and below. The transformer is based upon world-wide advanced technology and also incorporates the experiences of internationally leading transformer companies as well as our own long-term experiences. Low loss, low partial discharge and high short circuit withstand capability series transformers are achieved through innovation and optimization. Our transformer conform entirely with latest national standard GB1094.1~2-1996, GB1094.3-2003, GB1094.5-2003 and international standard IEC-76. Outstanding features as follows: 1. Low loss, low noise The core laminations are composed of imported high quality grain-oriented cold-rolled silicon steel sheets with chamfered joints and the joints are step-lapped with 5 steps, thus ensuring low loss and low noise. The inside of the tank is lined with magnetic and copper shields, measures have been take for metallic structural pares located in high magnetic field, to deduce stray loss and thereby the total load loss, and to relieve local overhearing. Performance standard of 330kV class transformers which designed and manufactured by our company, can reach GB 10-type or GB11-type, and the noise is much lower than GB. 2. Safe and reliable service Reliability is the everlasting objective of our company, partial discharge of finished products are constantly kept below 100pC, ensuring that the transformers can be operated under long service voltage and occasional over-voltage without trouble. Low current density in winding conductor and appropriate cooling arrangement ensure that the winding temperature rise and top oil temperature rise are lower than that specified in the national standard by more than 5K and that the mechanical stress in winding conductor during short circuit does not exceed certain safe limit. Together with technological procedures during manufacture and other means to elevate mechanical strength, transformers can withstand server short circuit in all case during service. 3. Easy erection and maintenance To minimize erection work at sit, transformers are so fabricated that lifting the active part out of the tank for inspection after arrival at sit is not mandatory. Beside, all components to be mounted on the transformer at site have been preassembled before dispatch, and all secondary wirings have been laid down into conduits on the transformer and connected to the terminals in the control cabinet or terminal box. Natural oil circulation and forced air cooling (ONAF) are generally adapted in our 180kV class transformers below 240MVA. 70% nameplate rating can still be achieved in case the fans are out of service. Little maintenance work is required for the cooling devices. 4. Careful fabrication Vertical winding machines with tension device are used for winding, so that the windings can be wound more tightly and therefore mechanically strength as a whole. All insulation parts subjected to mechanical stress during short circuit, such as spacers in windings are made with T4 densified pressboard to deduce shrinkage. Drying process for the windings are carried out twice, once for ht individual winding, and again for the assembled phase block. After core and coil assembly, an additional vapor phase drying (VPD) is once more carried out to ensure that all insulation parts are thoroughly dried and no further shrinkage is possible to occur during service. All the high voltage terminals and nearby metallic structural parts are rounded up to prevent partial discharge. High voltage bushing terminals are contained with turrets, and kept concentric with the turret. All the leads are properly crimped and metallized to be rounded up. VPD process insures that the moisture content within the transformer is kept at a very low level, and the core and coil assembly is once more cleaned by condensed vapor flowing down the surfaces. The fabricated tanks are relived from welding stress and shot-blasted integrally, so as to be free form oil leakage trouble and to give the tank a clean, pleasant looking appearance. fumigation wooden case
Step down from 11000/22000/33000 volts to 433 volts. Oil filled oltc transformers from Kva rating (kva) - 400 to 2500 No load loss (kw) - 1.2 to 3.4 Load loss (kw) - 6.0 to 28.0 %z - 4.5 to 6.25 Basic price (usd) - on demand only
PION range of low voltage transformers comprise of double wound and custom designed transformers. PION transformers are available in open enclosed, oil cooled models to suit the customer requirement. Air cooled transformers are available in Open and Enclosed models. The enclosed models are supplied in sheet steel enclosures. Louvering is provided for the heat dissipation of the generated heat. Oil cooled transformers are housed in MS Tank and provided with adequate pressed steel radiators to ensure proper heat dissipation Oil cooled units are available with standard accessories viz. oil level indicator, drain plug / drain valve, earth terminals, unidirectional CI wheels, Oil fill hole and terminal covers.
100kva electrical power transformer price Ai Power offers three phases, oil immersed, and naturally cooled distribution and power transformers. Our products from 10kva to 20000kva with a maximum voltage 35kv are manufacture under the standard of IEC60076. The windings are made of high-grade electrolytic cooper and are concentrically positioned. Usually copper foil is used for the low voltage windings. Round shaped, enamel insulated wires is used for the high voltage windings.
This standard is applicable to three-phase double winding oil immersed power transformers with rated voltage of 6 and 10kV, rated capacity of 30 ~ 6300kVA and frequency of 50Hz. This standard is not suitable for dry and damp heat belt type power transformer and power plant, transformer substation own three phase power transformer.