Vortex and swirl flow meter
Vortex and swirl flow meter
â?¢ EMF-50-PFA-SS316L-MS-150-NO-1-0-0-1-220V Accumax offers water metering solutions based on proven technology of Electromagnetic and represent the next generation of smart metering.Accumax delivers solutions in all shapes and sizes. From individual meters and remote reading systems to fully automated service solutions.The meter is true volume measuring meter. The measurement is independent of viscosity, Density, Dissolved/Undissolved solids, pressure or temperature of the flowing liquid as long as it maintains certain minimum conductivity. Various types of Liner & Electrode are used as per application requirements. Empty pipe detection is also provided.Accumax has in-house R&D centre & calibration setup as per industries standards.Principal of Operation:The Accumax Electromagnetic Flow-meter work on FARADAYs LAW OF ELECTROMAGNETIC INDUCTION. Hence the meter detects flow based on velocity of conductive liquid. Thus the meter are Calibrated in terms of volumetric flow rate from
Accumax offers water metering solutions based on proven technology of Electromagnetic and represent the next generation of smart metering.Accumax delivers solutions in all shapes and sizes. From individual meters and remote reading systems to fully automated service solutions.The meter is true volume measuring meter. The measurement is independent of viscosity, Density, Dissolved/Undissolved solids, pressure or temperature of the flowing liquid as long as it maintains certain minimum conductivity. Various types of Liner & Electrode are used as per application requirements. Empty pipe detection is also provided.Accumax has in-house R&D centre & calibration setup as per industries standards.Principal of Operation:The Accumax Electromagnetic Flow-meter work on FARADAYs LAW OF ELECTROMAGNETIC INDUCTION. Hence the meter detects flow based on velocity of conductive liquid. Thus the meter are Calibrated in terms of volumetric flow rate from it.Advantages:
Accumax offers water metering solutions based on proven technology of Electromagnetic and represent the next generation of smart metering.Accumax delivers solutions in all shapes and sizes. From individual meters and remote reading systems to fully automated service solutions.The meter is true volume measuring meter. The measurement is independent of viscosity, Density, Dissolved/Undissolved solids, pressure or temperature of the flowing liquid as long as it maintains certain minimum conductivity. Various types of Liner & Electrode are used as per application requirements. Empty pipe detection is also provided.Accumax has in-house R&D centre & calibration setup as per industries standards.Principal of Operation:The Accumax Electromagnetic Flow-meter work on FARADAYs LAW OF ELECTROMAGNETIC INDUCTION. Hence the meter detects flow based on velocity of conductive liquid. Thus the meter are Calibrated in terms of volumetric flow rate from it.Advantages:
Water Milk Analog Magnetic Flow Meter Price Electromagnetic Flowmeter Wastewater Flow Meter, Mechanical Smart Electromagnetic Flowmeter Quick Details: Place of Origin Henan, China (Mainland) Brand Name WEILI Model Number MGG Product Name MGG Medium Corrosive Accuracy 0.5% Power supply 220VAC/ 24VDC Output 4-20mA /RS485 Application Measuring Liquids Connection Thread Material Stainless Steel Type Integral Product Description: Magne W3000 PLUS Sanitary Centrifugal type Electromagnetic flowmeter adopting new sanitary centrifugal liner and technology ,which is in line with the food industry hygiene requirements , At the same time, its stainless steel shell connected with stainless steel clamp ,easy to remove and clean , so that the flowmeter can not easily be contaminated in using process and applied in food manufacture processing of Mineral water, soy sauce, jam, beer, fruit juice, rice, milk ,etc and Health and chemical industry . Nominal Bore DN10ï½?DN300mm Nominal Pressure 1.0ï½?4.0MPa Accuracy ±0.5%ï¼?±0.3% Flow range 0ï½?10m/s(Flow Velocity) Liner materia PFA Measuring Electrodes 316L Stainless steel , Harrington alloy B/C, Titanium , Tantalum Shell material Stainless steel Medium temperature Remote type-10 ~+160 ,Integral type -10 ï½? +80 Connection Mode ISO Standard Quick Connector Main Features: 1) It adopting new sanitary centrifugal liner,that prevent the residue of measured media accumulated in the measuring pipe . 2) It used Fast Connection program and makes the demolition of the electromagnetic flowmeter, maintenance and cleaning to be facilitated. 3)It uses 16 digit embedded Super-Micro power consumption Microprocessor ,meanwhile adopts special technical designing excitation system of sensor ,having the functions such as higher integration ,fast in operational speed ,best accuracy in calculation ,digital signal processing ,strong capability of interference immunity ,stable and reliable measurement. 4)The flowmeter is a two-way measurement system with three totalizers: positive total, reverse total and total difference; can display positive and negative flow, and has multiple outputs: current, pulse, digital communication, HART protocol.
RS485 Pulse Output Signal Digital Flange Inline Type Ultrasonic Water Flow Meter Newest Product TUF-2000F2 1. Protection Class: IP68 2. Pipe Size: DN15~DN6000 3. The main unit suits to install on the pipe, all parts achieve to IP68. Adapt to many severe working environment. 4. OEM supported.
External level transducer is an instrument which adopts sonar ranging and micro vibration analysis technology to measure the liquid level from the outside of the container. There is no need to opening holes on the tank wall, as well as the flange, it doesn contact the gas and the liquid in the tank. It is a completely non-contact instrument to realize the online installation and maintenance.
SYSTEM INFORMATION The electromagnetic flow meter HMF 2110 series is the most common and highly accurate flow measurement device that can be universally used in various measurement fields. Since there is no driving part like a propeller, no trouble is caused due to pressure loss, and the durability is excellent In addition, since the installation is simple with the flange type, even a beginner can easily install it through simple training. The sensor measures the flow rate by direct contact with the fluid,, thus a more reliable flow rate value can be obtained, and the reproducibility is also excellent If you are looking for a flowmeter that can be used with confidence, choose the HMF 2110 series without hesitation. â?? KEY FEATURES Quick Start Self diagnostic Easy Maintenance â?? CHARACTERISTICS â?¢ Due to high stability, popular for water flow measurement â?¢ Excellent durability due to no driving part â?¢ Electrode and lining materials are selected for measuring chemical flow â?¢ There is no pressure drop, which reduces electricity costs. â?? SPECIFICATIONS * Sensor installation method : Flange mounting type (Standard: JIS, DIN, ANSI, etc.) * Accuracy : �±0.2% (flow rate 0.1 m/s or more)0.2% (flow rate 0.1 m/s or more) * Max Minimum Flow : 0.05 m/s ~ 10 m/s (Flow rate by diameter) * Measuring pipe caliber : 6 mm ~ 2,000 mm * Measurable fluid : Water, sewage, wastewater, chemicals, etc. (Conductivity of 5�¼S /cm or more) * Power : 110 ~ 220 V AC / 60 Hz * Operating temperature : Sensor (40 ~ 70 â??), Operation: (18 ~ 60 â??) * Screen display contents : LCD Size: LCD Display 100 x 55, 3 Line, 16 Characters, Instantaneous flow rate (4 digit), accumulated flow rate (9 digit), pressure (4 digit) * Flow display unit : Unit: m3, L, etc. / Directions: Forward & Reverse (-) * Electrode : Hastelloy C * Liner: NBR, Hard Rubber, EPDM * Flange : Carbon Steel * Flow measurement frequency : 1.875 ~ 12.5 Hz * Sensor cable length : 100m * Output signal : 4 ~ 20 mA, Integrated pulse active , Passive (Max 10 kHz), Relay pulse (Max Load 24 V DC / 1A) * Communication and memory : RS 232, RS 485 Modbus 128 Mbyte internal memory: date, time, instantaneous flow rate, accumulated flow rate, Pressure memory interval: 5 seconds ~ 24 hours * Protection class : Sensor unit: IP 68 / Operation unit: IP 65 * Self diagnosis function : Alarm display when empty pipe information and self diagnosis error occur For more details on quality Korean flowmeters, please feel free to visit http://www.hnl-global.com/flowmeter and contact us.
System Information The electromagnetic flow meter HMF 2110 series is the most common and highly accurate flow measurement device that can be universally used in various measurement fields. Since there is no driving part like a propeller, no trouble is caused due to pressure loss, and the durability is excellent In addition, since the installation is simple with the flange type, even a beginner can easily install it through simple training. The sensor measures the flow rate by direct contact with the fluid,, thus a more reliable flow rate value can be obtained, and the reproducibility is also excellent If you are looking for a flowmeter that can be used with confidence, choose the HMF 2110 series without hesitation. â?? KEY FEATURES Quick Start Self diagnostic Easy Maintenance â?? CHARACTERISTICS â?¢ Due to high stability, popular for water flow measurement â?¢ Excellent durability due to no driving part â?¢ Electrode and lining materials are selected for measuring chemical flow â?¢ There is no pressure drop, which reduces electricity costs. â?? SPECIFICATIONS * Sensor installation method : Flange mounting type (Standard: JIS, DIN, ANSI, etc.) * Accuracy : �±0.2% (flow rate 0.1 m/s or more)0.2% (flow rate 0.1 m/s or more) * Max Minimum Flow : 0.05 m/s ~ 10 m/s (Flow rate by diameter) * Measuring pipe caliber : 6 mm ~ 2,000 mm * Measurable fluid : Water, sewage, wastewater, chemicals, etc. (Conductivity of 5�¼S /cm or more) * Power : 110 ~ 220 V AC / 60 Hz * Operating temperature : Sensor (40 ~ 70 â??), Operation: (18 ~ 60 â??) * Screen display contents : LCD Size: LCD Display 100 x 55, 3 Line, 16 Characters, Instantaneous flow rate (4 digit), accumulated flow rate (9 digit), pressure (4 digit) * Flow display unit : Unit: m3, L, etc. / Directions: Forward & Reverse (-) * Electrode : Hastelloy C * Liner: NBR, Hard Rubber, EPDM * Flange : Carbon Steel * Flow measurement frequency : 1.875 ~ 12.5 Hz * Sensor cable length : 100m * Output signal : 4 ~ 20 mA, Integrated pulse active , Passive (Max 10 kHz), Relay pulse (Max Load 24 V DC / 1A) * Communication and memory : RS 232, RS 485 Modbus 128 Mbyte internal memory: date, time, instantaneous flow rate, accumulated flow rate, Pressure memory interval: 5 seconds ~ 24 hours * Protection class : Sensor unit: IP 68 / Operation unit: IP 65 * Self diagnosis function : Alarm display when empty pipe information and self diagnosis error occur For more details on quality Korean flowmeters, please feel free to visit http://www.hnl-global.com/flowmeter and contact us.
[ CHARACTERISTICS ] Wide Beam Transducer (Broadband ultrasonic measurement function) Determine the transmission frequency by finding the resonance frequency of the pipe according to the outer diameter, material, and thickness of the pipe â?¢ Little error occurs due to stable signal reception â?¢ Excellent measurement stability even when there are air bubbles slurry (30% or less), scale generation, changing temperature and density. How to install â?¶Pipe Configuration (automatic correction of disturbance factors) â?¢ In actual industrial sites, sufficient straight pipe without interference is required for accurate flow measurement â?¢ If no sufficient straight pipe is secured ; - Re estimation of correction factors for disturbance factors and distances from disturbance factors, self compensation. - It has the same accuracy as that in which a sufficient intuition is secured even at a short distance from the disturbance factor. â?¶Other Functions * Diagnostic Menu (Self diagnosis function) * Auto Zero (Automatic zero adjustment function) * MultiPulse Transmission (Multi pulse function) * Liquid Class Menu (Fluid selection function) [ SPECIFICATIONS ] * Ultrasonic firing method : Wide beam * Flow measurement range : 0.0003 m/s ~ 30 m/s (by diameter) * Accuracy : HUF 2000N: within 0.5 ~ 1% (Normal / Precision sensor) HUF 2000DN: Within 0.5% (Precision sensor) * Measurable pipe diameter : 6.4 mm ~ 6,000 mm * Measurable pipe material : Steel, ABS, Aluminum, Black Iron, Brass, Cast Iron, Copper, Ductile, Glass, Hastelloy, etc. * Measurable fluid : Water, Wastewater, Oil (Turbidity 30,000 mg / L or less, Bubble 30% or less) * Power : 110 ~ 220 V AC / 60 Hz * Operating temperature : General sensor (40 ~ 120 â??), High temperature sensor (40 ~ 230â??), Indicator (18 ~ 60â??) * Display : HUF 2000N: 100 x 55 / HUF 2000DN: 120 x 64 * Display contents: Instantaneous flow rate (4 digit), Accumulated flow rate (8 digit), Flow rate (3 digit), Pressure (4 digit), Ultrasonic velocity (Vs ), Air volume (Air), Signal strength, * Flow / Time display unit : m3 & L / Forward & Reverse (--) / Second (s), Minute (min), Hour (h) & Day * Input signal : HUF 2000N: 1 pressure signal / HUF 2000DN: 2 4 ~20 mA, 2 RTDs * Output signal : 4~20 mA, Integrated pulse, RS232 / RS 485 MODBUS * Protection grade : Sensor: IP 68 / Indicator: IP 65 * Sensor cable length : Max. 600m * Storage content and capacity : Date, time, instantaneous flow rate, integrated flow rate, pressure, signal intensity, ultrasonic velocity, etc. Memory storage at regular intervals (5 sec. ~ 24 hrs.) (1 year can be stored at 1 min. intervals)
[ CHARACTERISTICS ] ¶Wide Beam Transducer (Broadband ultrasonic measurement function) ?¢ Determine the transmission frequency by finding the resonance frequency of the pipe according to the outer diameter, material, and thickness of the pipe â?¢ Little error occurs due to stable signal reception â?¢ Excellent measurement stability even when there are air bubbles slurry (30% or less), scale generation, changing temperature and density. How to install â?¶Pipe Configuration (automatic correction of disturbance factors) â?¢ In actual industrial sites, sufficient straight pipe without interference is required for accurate flow measurement â?¢ If no sufficient straight pipe is secured ; * HUF 2000N / HUF 2000DN (Compensation Type Ultrasonic Flow Meter) - Re estimation of correction factors for disturbance factors and distances from disturbance factors, self compensation. - It has the same accuracy as that in which a sufficient intuition is secured even at a short distance from the disturbance factor. â?¶Other Functions * Diagnostic Menu (Self diagnosis function) The attenuation degree, correlation degree, and noise degree of the ultrasonic received signal can be known and quantified to display empty pipe information, strength of the received signal, bubble content, S/N ratio, etc. * Auto Zero (Automatic zero adjustment function) In the first installation, zero point can be automatically adjusted without stopping the flow. Periodic automatic zeroing can prevent zero deformation caused by other factors. * MultiPulse Transmission (Multi pulse function) The pulse signal to analyze the time difference waveform transmit 50 pulse signals per measurement cycle, thus it has excellent measurement sensitivity and stability of ultrasonic signals. * Liquid Class Menu (Fluid selection function) A list of about 30 types of fluids is provided. When selecting fluids, the expected ultrasonic velocity (m / s), viscosity ( cS ), density (SG), and data are automatically entered and the pipe temperature range can be selected. Pipe Data Menu (Pipe selection function With more than 40 types of standard pipes and custom pipes built in, you can enter pipe outer diameter, material, and thickness using a list of pipe class and size options.
1. Non-invasive transducers are easy to install, cost effective, and require no pipe cutting or processing interrupt. 2. Wide liquid temperature range: -35~200. 3. Data logger function. 4. 14 hours battery(rechargeable), back-lit 4 lines display. 5. For commonly used pipe materials and diameters from 20mm to over 6.0m. 6. Wide bi-directional flow range of 0.01 m/s to 12 m/s.
Prices Mentioned above is for base model only
JC040 Vortex Natural Gas Flow Meter JC-040 series smart precession whirlpool flowmeter uses new microprocessing techn ology with strong function, wide flow range, simple maintenance and co nvenient installation & use. It is widely used in industries such as petrol, chemical, power, metallurgy and coal, etc. BCST Natural Gas Flow Meter Feature� 1.� Built-in pressure, temperature and flow sensors with high safety, compact structure and exquisite shape. 2.� Local indication of temperature, pressure, instantaneous flow and accumulative flow. 3.� Use new signal processing amplifier and unique filtration technology, effectively eliminate interfering signal generated by pressure fluctuation and pipeline vibration, greatly improve anti-interference ability of flowmeter, and make good stability of little flow. 4.� Special time indication and real-time data storage function; under no circumstance will the internal data be missing and will be stored forever. 5.� Password protection 6.� Low power consumption, internal battery supply, no need for external power supply. If you want to know more about this product, you can click the link below 1. Specification, basic data and performance
JC091 Insertion Remote Electromagnetic Flowmeter BCST Battery Electromagnetic Flowmeter is a new fluid flowmeter developed based on pipe-type electromagnetic flowmeter. Besides preserving the merits of pipe-type electromagnetic flowmeter and considering such defects of pipe-type electromagnetic flowmeter as difficult installation on large pipes and high cost. Compared to ordinary electromagnetic flowmeter, sensor of BCST insertion electromagnetic flowmeter generates external emission magnetic field on outer side. The measuring electrodes are at the ends or on both sides of the sensor. Principle of electromagnetic flowmeter� is shown in the figure below. It is noteworthy that in external emission magnetic field, the induction signal of electromagnetic flow sensor will reduce the linearity of measurement in case of being affected by fluid and thickness of the magnetic field's boundary layer. In terms of� JC091� insertion electromagnetic flowmeter, conducting liquid in pipeline is the conductor moving in magnetic field and distance between two electrodes is the length (L) of conductor.� Accuracy �±0.5%~�±1.5% (under reference conditions) Caliber (mm) DN100~DN3000 DN100~DN3000 Flange Conforming to GB9119, stainless steel Pressure rating 1.6MPa Material of converter housing Die-cast aluminum alloy Material of sensor housing Stainless steel Material of sensor structure Stainless steel/PVDF Weight 6 kg Electrical conductivity ¼s/cm (negotiate with us for ordering in case of less than 5¼s/cm)
Pipe type ultrasonic flowmeter is composed of a main body and a pipe segment type sensor. The DN15-DN32 uses a -type pipe segment sensor, and the DN40 and above uses a standard pipe segment sensor. The pipe-type ultrasonic flowmeter has the advantages of simple installation, low starting flow, high measurement accuracy, and no pressure loss.The applicable diameter is DN15~DN6000.
Plug-in ultrasonic flowmeter is composed of a main body and an external clip type sensor. Simply attach the clip-on sensor to the surface of the pipe to complete the flow measurement of various liquids. Compared with the traditional flow meter, it does not need to cut off the tube, and the installation is quick and convenient, realizing the non-destructive installation. Both the main unit and the sensor are mounted on the pipeline with protection class IP68. The external clip type sensor is installed on the surface of the pipe, and different sensors are selected. The applicable diameter is DN50~DN6000.
External clip type ultrasonic flowmeter is composed of a main body and an external clip type sensor. Simply attach the clip-on sensor to the surface of the pipe to complete the flow measurement of various liquids. Compared with the traditional flow meter, it does not need to cut off the tube, and the installation is quick and convenient, realizing the non-destructive installation. The main unit can be installed in the wall, instrument box and distribution box, and the protection level can reach IP67. The external clip type sensor is installed on the surface of the pipe, and different sensors are selected. The applicable diameter is DN15~DN6000.
Portable ultrasonic flow meter enables non-contact measurement of liquid flow. By installing the sensor on the outer wall of the pipe, the flow measurement can be completed, which is convenient and accurate. Built-in printer and SD card memory for immediate or timed printing of set measurements. It is widely used in tap water, heating, water conservancy, metallurgy, chemical, machinery, energy and other industries, can be used for production testing, flow comparison, temporary monitoring, is a necessary tool for flow detection.