DESCRIPTIOn: Titanx100 RADIOGRAPHY RATING: 25-100mA, stations 45kVp to 100 kVp in 15 steps OUTPUT: 8KW RECTIFICATION: Full Wave Rectified TIMER: 0.06 to 5 sec DIGITAL DISPLAY : Digital Display of mAs, kV & mA X-RAY TUBE: XD-3/Imported POWER SUPPLY: 230 Voltage AC, 15 Amps LINE REGULATION: 10% 0.6max PROTECTION: Electronic overload Protection TUBE STAND counter Balance Mobile
DESCRIPTION: Titanx RADIOGRAPHY RATING: 25-100mA, stations 45kVp to 100 kVp in 15 steps OUTPUT : 8KW RECTIFICATION: Full Wave Rectified TIMER: 0.06 to 5 sec DIGITAL DISPLAY: Digital Display of mAs, kV & mA X-RAY TUBE: XD-3/Imported POWER SUPPLY: 230 Voltage AC, 15 Amps LINE REGULATION: 10% 0.6max PROTECTION: Electronic overload Protection TUBE STAND: Floor to Ceiling Column Stand
DESCRIPTION: Titanx100 RADIOGRAPHY RATING: 25-100mA, stations 45kVp to 100 kVp in 15 steps OUTPUT : 8KW RECTIFICATION: Full Wave Rectified TIMER: 0.06 to 5 sec DIGITAL DISPLAY: Digital Display of mAs, kV & mA X-RAY TUBE: XD-3/Imported POWER SUPPLY: 230 Voltage AC, 15 Amps LINE REGULATION: 10% 0.6max PROTECTION: Electronic overload Protection TUBE STAND: Counter Balance Mobile
DESCRIPTION- TITANX 100 RADIOGRAPHY RATING- 25-100mA, stations 45kVp to 100 kVp in 15 steps OUTPUT 8KW RECTIFICATION- Full Wave Rectified TIMER- 0.06 to 5 sec DIGITAL DISPLAY- Digital Display of mAs, kV & mA X-RAY TUBE- XD-3/Imported POWER SUPPLY- 230 Voltage AC, 15 Amps LINE REGULATION- 10% 0.6max PROTECTION- Electronic overload Protection TUBE STAND- Spring Balance
Portable X-ray Fluoroscopy Instrument PLX5200A Technical parameters of veterinary digital radiography systems : Output power:25kW mAs:360mAs Inverter Frequency:60kHZ mobile x-ray machine 300ma mobile x-ray machine ppt mobile x-ray machine safety
1. When adding up voltage, total current is less than 2a and total power is 500w; 2. The current and voltage of x-ray tubes are fixed in three groups, they are: X exposure voltag (kvp) 60 65 70 X-ray current (ma) 0.5 0.85 1.10 3. When adding up voltage, total current is less than 2a and total power is 500w 4. Drain current and earth resistance are in accordant with the stipulates in gb9706.1 5. The three groups of voltage (60kv, 65kv, 70kv) are adjustable. 6. Wireless remote control in any angles within 10 meters part form the control box 7. The parameter of x-ray generator (bulb tube head) the parameter of x-ray tubes A focus index: 0.3*0.3mm2 B. The voltage of the-highest-voltage generator: 90kv C. The highest inverse peak voltage: 90kv D. Filament characteristic: vf=5v+0.5v, f=3a E. Target surface obliquity: 12 F. The cooling manner of bulb tube head: oil immersion The parameter of x-ray generator (bulb tube head): A. Focus-skin distance: 200mm B.The thickness of filter-ray film: more than 1.5mmal C.The leakage rate of x-ray: no more than 0.002mgy/h (no. 29.204.3 in gb9706.12 prescript that the leakage rate of x-ray is no more than 0.25mgy/h) D. The manner of limiting beam: using planigraphic device
Detecting such as stone ,sand,teflon,fe,sus ,non-fe,harder material and so on in the food stuff
PLX101 Series High Frequency Mobile X-ray Equipment PLX101/101A/101C Rocker safety lock design, make your operate much safer High quality x-ray monoblock assures more details, less dose Symmetrical adjustable collimator for accurate positioning and better exposure protection Aviation aluminum connectors, connection reliable, more safety Advanced dislocation braking system, flexible movement, flexible braking Multifunctional cassette storage box design Features Our high frequency technology assures the best image in every operating condition Along with reduced patient dose and extended x-ray tube life time The generator provide the right amount of penetration, reducing exposure times and retakes. The parameter can be adjusted by the kV and mAs. Multiple security protect function such as over-voltage, over-current. 50 preset exposure programs allow extensive possibilities to optimize the exposure and processing parameters according to your preferences. Fault automatic protection setting and fault alarming display Parameters are automatically storage when power cut off. Adopt rotating beam limiting device to adjust the X-ray field and angle freely. Adopt manual controller and remote controller to do exposure. Optional: PLXF152 mobile table for high frequency mobile X-ray equipment. PLX101D is equipped with built-in battery, can take 200 films when full charged. Rocker can move up and down, automatically balance High quality X-ray monoblock can rotate in ±90 Options PLXF152 Mobile Bed For Mobile X-ray Machine Size: 2000 X 700X 500mm Range of grid box movement 1210mm Size of grid box: 430X 430(17 X 17) Bucky Stand Height: 1770mm Vertical movement range: 470-1470mm Grid density: 103L/inch Grid radio: 10:1 Focus distance: 150cm Maximum grid box: 17 X 17 Technical Parameters
X - Ray Tubes , CT tubes Our products are with german brand NAGO and german technology. We provide X-ray tubes for medical ,industry and inspection systems . The tubes can replace Siemens , Philips , Varian ,Toshiba ,IAE and other brand tubes . We provide also X-ray tube accessories like glassbulb, target , rotor and so on. Offering mechanical parts processing work according to customer's drawing and requirements .
100 mA, 100 KVP Mobile X-ray Machine 100mA, 100 KVP, Mobile X-ray Machine for Radiography only Electronic Timer Electronic Overload Protection Device Stationary Anode X-ray Tube : BEL or Imported Collimator Counter Balanced Mobile Stand Suitable for Bed Side X-rays
Suited to a range of imagers and general radiology applications Five film sizes on 7-mil blue polyester base AIQC system-matched with the DRYVIEW Laser Imagers AIQC ensures contrast and density meet preset user preferences Quality control performed without operator intervention to enhance productivity Storage and Handling of Film Unexposed DRYVIEW DVE Film must be stored at 39 to 75�?�°F (4 to 24�?�°C), at 30 to 50% RH, and properly shielded from x-rays, gamma rays, or other penetrating radiation in order to achieve consistent results up to the expiration date indicated on the film package. Note that DRYVIEW models 8700, 8150 and 8300 are not compatible with DVE Film. To determine if your laser imager needs a software upgrade or is compatible with DVE �¢?? download our information sheet here. Choose from five sizes on 7-mil polyester base to suit your DRYVIEW Laser Imager and imaging applications: 14 x 17 in. (35 x 43 cm.) 11 x 14 in. (28 x 35 cm.) 10 x 12 in. (25 x 30 cm.) 8 x 10 in. (20 x 25 cm.)
There are many different models available for an X-ray baggage scanner, depending on the location and purpose of the X-ray scanner. The tunnels of the x-ray baggage scanner are determined according to the place to be used. 50x30 tunnels are usually suitable for places entered with handbags, such as shopping mall entrances, public institutions, and organizations; as the size of the package to be controlled increases; 65x50, 80x65, or 100x100 will be more convenient. Sites such as airports, bus terminals, hotel entrances should prefer devices with large tunnel measurements.
We're a leading XRay machine and accessories manufacturer company with over 29 years of experience and global presence and distributor network in 7 different countries. We have Line Frequency & High Frequency, APR X-Ray Machine, Dental X-Ray Machine, Mobile 100MA X-Ray Machine, 300MA X-Ray Machine, 500MA XRay Machine, Vertical Bucky, Multi-Position Bucky Table, 4 & 2 Way Floating Bucky Table Etc Beside new machines, we offer complete modification & repairing of any brand XRay machines, Rotating Anode Tube Head, HT 100MA, 300MA, 500MA Etc
Power Output 5.0KW x ray machine Main Inverter frequency 40 KHz X-ray Tube of radiography machine fixed anode focus: 1.5 (X-ray tube for high frequency) Power Supply 220V�±10% 50Hz Inner-resistance â?¤1.0�© Operation Method Wire/wireless control mobile x-ray machine safety mobile x ray machine cost mobile x ray machine price
Power Output 5.0KW Frequency 40KHz Power Supply 220V± 10% 50Hz inner-resistance Operation Method Wire/Wireless control mobile x ray machine cost mobile x ray machine price mobile x ray machines ww1
Mobile 100mA high frequency X-ray system PLX101C for sale Item Contents Environmental Conditions No erosive volatile gas and dust around Temperature +10â??~+40â?? Relative Humidity 30%~75% Atmospheric Pressure 700 hpa~1060hpa Power Output 5.0KW Frequency 50kHz Tube Voltage 40~120KV Power Supply 220V±10% 50/60HZ Internal Resistance less than input power 9kVA Operation Method Wire/Wireless Control Dimension 120cm*62cm*130cm Net Weight 150kg mobile x ray machine cost mobile x ray machine price mobile x ray machine ww1
2.5kw high frequency portable X-ray machines PLX101 x ray tube Fixed Anode Power Output of x ray machine 2.5kW Frequency 25kHz Tube voltage 40~100kV Power Supply 220V�±10%, 50kHZ Operation Method Wire/ Wireless control price list of x-ray machine price of 500ma x-ray machine price of medical x ray machine
brand of surgical x-ray equipment PLX101D mobile x ray machine for sale price of x ray machine mobile x ray machine specifications Power Output 5.0KW x ray machine Main Inverter frequency 40 KHz X-ray Tube of radiography machine fixed anode focus: 1.5 (X-ray tube for high frequency) Power Supply 220V±10% 50Hz Inner-resistance Operation Method Wire/wireless control
Available in all sizes