The DN80 flange is a type of pipe flange commonly used in industrial applications. It has a nominal diameter of 80 millimeters, making it suitable for connecting pipes with a similar diameter. Flanges play a crucial role in joining pipes or connecting them to various equipment, ensuring a secure and leak-proof connection. The DN80 flange is typically made of durable materials such as carbon steel, stainless steel, or alloy steel, which offer high strength and resistance to corrosion. Its standardized design allows for easy installation and maintenance, making it a preferred choice in many industries for ensuring the efficient and safe transfer of fluids.
Steel DN65 flange can be customized. A flange is a mechanical joint commonly used in piping systems to connect two sections of pipe or other equipment together. It usually consists of a flat, circular disk with evenly spaced holes around its perimeter. The flange is positioned between two pipe ends and secured using bolts, creating a tight seal that prevents leaks. In addition to providing a secure connection, flanges also allow for easy assembly and disassembly of pipes, making maintenance and repairs more convenient. Flanges can be made from a variety of materials, such as carbon steel, stainless steel, or even plastic, depending on the specific requirements of the application. Their design and size vary depending on factors such as pressure rating, temperature, and pipe diameter. If you need customize flange, please leave your message, thanks a lot.
Product name: cnc precision auto parts Services: CNC Machining Services, CNC Machining Parts, Custom Machining Parts, Precision Machining Parts, Prototype Machining Components Process: Rapid prototyping, CNC machining, CNC turning, CNC milling, CNC drilling, CNC tapping, etc Material: Steel, Stainless steel, Aluminum, Copper, Brass, Titanium, Magnesium, Zinc, Plastic, Carbon fiber, etc. Finished: Bead blasting, Anodizing, Polishing, Painting, Plating, Powder coating, Black oxide, etc. As machined: Ra 3.2, break sharp edges and remove burrs. General tolerance: ISO 2768-mK If you want to know more information, please feel free to contact us; Upon receipt of your feedback, we will share you more relevant information and working videos for your reference.
Suitable for Water , Fire Fighting , Paper , Automotive , Chemical , Power , Oil & Gas industries Body : WCB , SGI , SS Pressure Rating : PN16 PN 160 Size Range : DN 15 DN 200 End connection : Flanged or Welded or Threaded Temperature Range : -10 degrees to 400 degrees
Suitable for Water , Fire Fighting , Paper , Automotive , Chemical , Power , Oil & Gas industries Body WCB , SGI , SS Pressure Rating : PN10 PN 100 Size Range : DN 40 DN 600 End connection : Flanged or Welded
Suitable for Water , Fire Fighting , Paper , Automotive , Chemical , Power , Oil & Gas , Chlor-Alkali industries Body : WCB , CF8 , CF8m Pressure Rating : Class 150-300 Body type : Single Piece , Two Piece and Three Piece designs Bore : Reduced Bore and Full Bore Size Range : DN 15 DN 200
Suitable for Water , Paper , Automotive , Chemical , Power , Oil & Gas , Pharma industries Body : CI , SGI, Cast Steel , SS , Gun metal Diaphragm : EPDM , PTFE , Viton Lining : Unlined and lined with PTFE , Rubber , PVDF , PFA , Plastic and Glass lining Body type : Weir A type and KB type Size Range : DN 15 DN 350 Temperature Range : -50 degrees to 175 degrees
Suitable for Water , Sugar , Paper , Automotive , Chemical , Power , Oil & Gas industries Body CI , SS , Disc - SGI , SS Liner replaceable EPDM with solid backing ring, RTFE, TFE Body type Wafer or Lug or double flanged Size Range DN 40 DN 1400 Pressure Rating PN10 , PN 16 , ASME class 150-600
According to IEC60695-2-2, IEC60695-11-5 and GB/T-5169.5, ZY-3/ZY-3S needle flame test equipment is applied in the production and quality control department of lighting products, hyperpiesia electrical apparatus, domestic appliance, machine electric appliance, electrical machine, power tool, electronic instrument, electrician instrument and technical equipment. Also, the apparatus is suitable for the industry of insulation material, engineering plastics and solid combustible material. Specifications: Angle of burner: 45 (when in test) / (when adjust the flame's height) Needle flame burning time: 0~999.9s±0.1s (adjustable, 30s in general) â?¢ After-flame time: 0~999.9s�±0.1s, auto record and pause manually â?¢ Height of flame: 12mm�±1mm (gauge is included) â?¢ Gas: 95% butane â?¢ Test range of temperature: 0~1000â?? â?¢ The temperature rises from 100â??�±2â?? to 700â??�±3â?? within 23.5 seconds�±1s â?¢ Thermocouple: �¦0.5mm K type â?¢ Applied with touch screen and remote control To save the delivery cost for the oversea market, LISUN designed a compact version needle flame test equipment weighing less than 50kg. (Customer need to prepare additional ventilation system for ZY-3S)
The ZRS-3H Glow-wire Test Apparatus is according to IEC60695-2-1, IEC60695-2-10, IEC60695-2-11, IEC60695-2-12, IEC60695-2-13 (GB/T5169.10, GBT5169.11, GBT5169.12, GB/T5169.13) < Basic testing methods of Glow wire, basic testing methods of Glow wire device>, UL 746A, IEC829, DIN695 and VDE0471. What is glow wire test? The Glow wire tester ZRS-3H/ZRS-3HS is suitable for resistance to abnormal heat and fire test on lighting lamps, electronic products and household appliances. It uses high-temperature coating spraying on steel structure and imported instrument display, with easy operation and stable performance. The glow wire testing equipment is applicable to flame resistance test of all levels of QC departments and corresponding enterprises. Specifications: Heating temperature: adjustable continuously within the range of 25~1100C, the accuracy of temperature is 1C, the resolution of temperature is ±3C Glow-wire time: 0.1-999.9s±0.1s(time range is adjustable) Ignition time: 0.1-999.9s, auto record, manual pause Flame-out time: 0.1-999.9s (auto record and manual pause) Glow wire pressure on test specimen: 1±0.2N. Limiting pressure depth is 7mm Glow wire: 4 nickel (80) and chromium (20) Made in specific dimensions. Thermocouple: �?0.5 armored nickel & chromium/nickel-chromium wire, K Type. Automatic departure: While reaching specified glowing time, test specimen will depart from glow wire automatically. To save the delivery cost for the oversea market, LISUN designed a compact version glow-wire tester weighing less than 50kg. (Customer need to prepare additional ventilation system for ZRS-3HS)
The SG61000-5 is an automatic surge generator (also called lightning surge immunity test, combination wave generator, surge current generator/surge voltage generator, combined surge voltage and current generator) . How does a surge generator work? The SG61000-5 surge generator provides a common basis for evaluating the resistance of power cords and internal connectors of different equipment to high energy transient interference caused by natural lightning surge induction and large capacity load switching. It fully meets the IEC 61000-4-5, EN61000-4-5 and GB/T17626.5 standards.
LSRF-3 Lamp start, Run-up time and Light Flickering Analyzer â?? Flicker Tester is equipped with Class A photo detector, so the sampling speed is up to 100kHz. It fully meets the requirement of BASIC, Energy Star V2.1, IEC TR 61547-1:2020 IEC-Pst, CA CEC, ASSIST, CIE TN006-2016 CIE SVM, IEEE Std 1789 standards, etc. It is professional for flicker test of LED lights and lamps, energy-saving lamps, etc. According to EU directives 1194/2012, 2009/125 / EC, SASO2902, COMMISSION DELEGATED REGULATION (EU) 2019/2015, COMMISSION REGULATION (EU) 2019/2020 and IEC60969 â??Self-ballasted Lamps for General Lighting Servicesâ??Performance Requirementsâ?? and other requirements. The LSRF-3 can connects with PC via USB cable. The English version software can be run in Win7, Win8 and Win10, Win11 (The driver was Certificated by Microsoft)
LPCE-2 Integrating Sphere Spectroradiometer LED Testing System is for single LEDs and LED lighting products light measurement. LEDâ??s quality should be tested by checking its photometric, colorimetric and electrical parameters. According to CIE 177, CIE84, CIE-13.3, IES LM-79-19, Optical-Engineering-49-3-033602, COMMISSION DELEGATED REGULATION (EU) 2019/2015, IESNA LM-63-2, IES-LM-80 and ANSI-C78.377, it recommends to using an array spectroradiometer with an integrating sphere to test SSL products. The LPCE-2 system is applied with LMS-9000C High Precision CCD Spectroradiometer or LMS-9500C Scientific Grade CCD Spectroradiometer, and a-molding integrating sphere with holder base. This sphere is more round and the test result is more accruate than the traditional integrating sphere. Measures: â?¢ Colorimetric: Chromaticity coordinates, CCT, Color Ratio, Peak Wavelength, Half Bandwidth, Dominant Wavelength, Color Purity, CRI, CQS, TM-30 (Rf, Rg), Spectrum Test â?¢ Photometric: Luminous Flux, Luminous Efficiency, Radiant Power, WPE, EQE, EEI, Energy Efficiency Class, Pupil Flux, Pupil Flux Efficiency, Pupil Factor, Cirtopic Flux, Plant Growth Lamp PAR and PPF â?¢ Electrical: Voltage, Current, Power, Power Factor, Displacement Factor, Harmonic(Optional) â?¢ LED Light Aging Test according to LM-80: Flux VS time, CCT VS time, CRI VS time, Power VS time, Power Factor VS time, Current VS time and Flux Efficiency VS time. Option: The LPCE-2(LMS-9000C) or LPCE-2(LMS-9500C) work with a IS-1.5MT Constant Temperature Integrating Sphere and TMP-8 Multiplex Temperature Tester can fully meet IES LM-82 High Precision LPCE-2(LMS-9000C) System Configuration (It is suitable for the Middle & Small Manufacturer or General Test Lab): High Precision CCD Spectroradiometer (LMS-9000C), Optical Fiber (CFO-1.5M), Digital Power Meter (LS2050B/LS2050C/LS2012), DC Power Source (DC Series), AC Power Source (LSP-500VARC or LSP-500VARC-Pst), Integrating Sphere (IS-1.5MA and IS-0.3M), Standard Light Source (SLS-50W and SLS-10W), 19 Inch Cabinet (CASE-19IN). You can download the detailed PDF here: LPCE-2 (LMS-9000C) High Precision CCD Spectroradiometer Integrating Sphere System Brochure±0.3nm, Wavelength Reproducibility: ±0.1nm Sample Scanning Steps: ±0.1nm Accuracy of Chromaticity Coordinate (x, y): ±0.002 (under Standard A Lamp) Correlated Color Temperature CCT: 1,500K~100,000K, CCT Accuracy: ±0.3% Color Rendering Index Range: 0~100.0, Accuracy: ±(0.3%rd±0.3) Luminous Flux Range: 0.01-200,000lm; Photometric linear Accuracy: ±0.5% Stray light:
LPCE-3 is a CCD Spectroradiometer Integrating Sphere Compact System for LED Testing. It is suitable for single LED and LED luminaires photometric, colorimetric and electrical measurement. The measured data meets the requirements of CIE 177, CIE84, CIE-13.3, COMMISSION DELEGATED REGULATION (EU) 2019/2015, IES LM-79-19, Optical-Engineering-49-3-033602, IESNA LM-63-2, ANSI-C78.377 and GB standards The Sphere System Configuration: CCD Spectroradiometer (LMS-7000), Optical Fiber (CFO-1.5M), Digital Power Meter (LS2008R), DC Power Source (DC-S Series), AC Power Source (LSP-500VAS), Integrating Sphere (IS-1.5MA-CASE and IS-0.3M), Standard Light Source (SLS-50W and SLS-10W) Measurement: Colorimetric: Chromaticity coordinates, CCT, Color Ratio, Peak Wavelength, Half Bandwidth, Dominant Wavelength, Color Purity, CRI (Ra, R1 to R15), Spectrum Test, TM30 (Rf, Rg), CQS Photometric: Luminous Flux, Luminous Efficiency, Radiant Power, EEI, PAR, PPF Electrical: Voltage, Current, Power, Power Factor, Harmonic (Optional) Specification: Spectral Range Wavelength: 350nm~950nm(LMS-7000VIS) (200~1050nm is optional) Spectral Wavelength Accuracy: ±0.5nm Wavelength Reproducibility: ±0.5nm Sample Scanning Steps: �±0.1nm Accuracy of Chromaticity Coordinate (IOx, y):±0.003 (under Standard A Lamp) â?¢ Correlated Color Temperature CCT: 1,500K~25,000K. CCT Accuracy: ±0.5% Color Rendering Index Range: 0~100.0, Accuracy: ± (0.3%rd±0.3) Photometric linear: �±0.5% Stray light:
The Portable CCD LED Colorimeter Spectroradiometer has the following versions which can measure different parameters
What is the definition of type C goniophotometer? LSG-6000 Moving Detector Goniophotometer (Mirror Type C) was manufactured by LISUN completely meets LM-79-19, IES LM-80-08, COMMISSION DELEGATED REGULATION (EU) 2019/2015, CIE-121, CIE S025, SASO 2902, IS16106 and EN13032-1 clause 6.1.1.3 type 4 requirements. LSG-6000 is the latest upgraded product of LSG-5000 and LSG-3000 in compliance with the requirements of the LM-79-19 standard Clause 7.3.1, its an automatic light distribution intensity 3D curve testing system for measuring light. The darkroom can be designed according to the customerâ??s existing room size. What is the use of goniophotometer? LSG-6000 gonio photometer manufacturer is LISUN, it can measure all types of lighting sources, LED, Plant Lighting or HID luminaires such as indoor and outdoor luminaires, roadway luminaires, street lamps, flood lights and other kinds of luminaires.
100% duty cycle operation; Energy-efficient performance; Advanced control solution; Service maintenance reminder; Lower oil change costs.
Main Features: 100% duty cycle operation Energy-efficient performance Advanced control solution Service maintenance reminder Lower oil change costs
100% duty cycle operation; Energy-efficient performance; Advanced control solution; Service maintenance reminder; Lower oil change costs.
100% duty cycle operation; Energy-efficient performance; Advanced control solution; Service maintenance reminder; Lower oil change costs.