HKKW2 Series of intelligent frame circuit breakers HKKW2 Series of intelligent universal circuit breaker is mainly used in AC. 50Hz, rated voltage of 400V(380V)íó690V(660V) and rated current between 630A-6300A power distributing work-net to distribute Elec. power and protect equipments from being damaged by over-load, short-circuit, under voltage and grounding fault, having many protective functions and ability of realizing accuracy protective action in selectivity, improving reliability and quality of supplying Elec. power. The breaker is widely used in modern Elec. power distributing network.
Helmets are made of FRP or Poly proplene with different colours and/or decals. Head size from 580 to 600 mm meeting quality standards of Bureau of Indian Standards (BIS), DOT (Select models), These helmets are available in full face, open face and flip type. Suitable for safety of 2 wheeler riders. Each helmet will have either Sun Peak or PP face Cover. Individually packed in Card Board Box and available in different colours and/or stickers.
Mini circuit breaker (1)inb2 (dz47) high-breaking mini circuit breaker The product is mainly used in ac 50/60hz. Voltage up to 400v circuit for overload and short-circuit protection as well as for unfrequent on-and off switching electric equipment and lighting circuit in normal case. The items comply with iec 60898&gb 10963. Rated voltage: 230v, 230/400, 400 v Pole number: 1, 2 ; 1, 2 ; 2, 3, 4 Rated current: 6, 10, 16, 20, 25, 32, 40, 50, 63 a (2)inb1-63 mini circuit breaker The items comply with iec 60898&gb 10963. It is mainly used for overload and short circuit protection in the circuit of ac 50/60hz, rated voltage of single pole up to 230v, two, three or four pole up to 400v. It can also be used for infrequent switch over of the circuit and illumination under normal conditions. (3)inb2-32 mini circuit breaker The items are used in ac 50hz or 60hz, 230v single phase dwelling house circuit for overload and short-circuit protection. The nature wire and live wire can be cut off synchronously to protect the life and avoid the fire. The items comply with iec60898&gb10963. Connection: rigid conductor 16mm2 Flexible conductor 10mm2 Rated voltage: 230v Pole number: 1p+n Rated current: 6, 10, 16, 20, 25, 32 a Breaking capacity: 4500a (4)bh(dz12-63) series mini circuit breaker The items are used in ac circuits 50hz forprotection of overload, short circuit and for circuit change-over in lighting system. Pole number: 1p 2p 3p Rated current: 6, 10, 16, 20, 32, 40, 50, 63 a Rated voltage: ac 120/230, 230/400 v Zhejiang inte industrial electric co., ltd. Was founded in 1984 and is iso 9001: 2000 certified. We mainly manufacture circuit breaker, thermal protector, thermostat and counter etc. Electrical and electronic equipments. Some of our products have got ccc, ul, vde, ce, saso approval. Leave factory packing
Circuit breakers, contactors, solar panels, solar dc breakers, and solar inverter.
DZ47-63 Series High Breaking Capacity Mini Breaker may be used in such occasions with AC 50 or 60Hz, rated working voltage of 415V or below and rated working current of 63A.It can servefor the illumination of office, residential housing and similar buildings and its distribution wires and protect the distribution circuit and equipment against overload and short-circuit.It can also be used for infrequent conversion of circuit under normal conditions. Rated current:1A, 3A, 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A Number of poles:1p, 2p, 3p, 4p Working voltage:From 240V to 415V DZ47LE Series Leakage Circuit Breaker may be used in the circuit with AC 50 or 60Hz, rated voltage of 230V or 400V and rated current of 63A or below. It can prevent personnel from electric shock, protect equipment against leakage and the circuit against overload and short-circuit It can also serve as infrequent conversion of circuit and infrequent startup operation of motor under normal conditions. Number of poles: 1p+n, 2p, 3p, 3p+n, 4p, Working voltage: 240V, 380/400V, 240V, 240/415V Rated current: 1A, 3A, 6A, 10A, 20A, 25A, 32A, 40A, 50A, 63A DZ20 series Moulded Case Circuit Breaker (hereafter refers to as circuit breaker) to be suitable to exchanges 50HZ. The nominal current from 16A to 1250A, fixed insulation voltage 660V, fixed working voltage 380V (400V) and in the below electric circuit makes the infrequent transformation and the electric motor infrequent starting using of. The circuit breaker has the overload, short-circuits and owes the voltage protective device, can protect the line and the power equipment is not damaged. This circuit breaker may be vertical the installment (namely vertical stroke to install), also may the level installment (namely horizontal attire). This circuit breaker carries out the standard: GB14048. 2 and IEC60947-2. Product model: Dz20-100, dz20-225, dz20-400, dz20-630, dz20-800, dz20-1250 Rated current: From 16A to 1250A Rated working voltage: 380V DZ30LE-32 Leakage Protector may be used in single-phase domicile circuit with AC 50 Hz or 60Hz, rated voltage of 220 V and rated current of 32 A. It can prevent personnel from electric shock, and protect vivil electric lines against overload and short-circuit. This product is of such characteristics as small volume, high breaking capacity and cutting off the live and zero lines at the same time. Rated current: 3A, 6A, 10A, 16A, 20A, 25A, 32A Number of poles: 1p+n Working voltage: 220V
HKKC1L Series of Mini. Breakers HKKC1L-63 series of residual Mini breakers is mainly used in AC. 50Hz/60Hz, rated voltage up to 400V below lines to protect load/lines from over-load, short-circuit and Elec. leakage. The product has a beautiful out-looking, light weight, perfect & reliable Elec. performances, high breaking capacity, rapid tripping and reliable mounting channel
JD156(DZ47) series circuit breaker is used in Helmet distribution system or motor distribution system for protection overload and short-circuits in the system. The product is neoteric in structure, light in weight, reliable and excellent in performance. It has high breaking capacity, can trip quickly, and its case and items are adopted by high fire-resistant and shockproof plastics. The product, with long life, is mainly used in AC 50/60HZ single-pole 240 or two, three four-pole 415V circuit for overload and short-circuit protection as well as for unfrequented on íºCand-off switching electric equipment and Helmet circuit in normal case.
C45n series circuit breaker is used in lighting distribution system or motor distribution system for protecting overload and short-circuit in the system. The product is novel in structure, light in weight, reliable and excellent in performance. Its frame and parts adopt plastics of high fire-resistant and shock- proof. The product, with long life, is mainly used in ac 50hz/60hz single-pole 240v or two, three, four- pole 415v circuit for overload and short-circuit prot- ection as well as for unfrequent on-and-off switching electric equipment and lighting circuit in normal case. The products comply with iec 898 & bs 3871.
125v sequence of events (1c31157g02) External power pulse accumulator (1c31150g03) 24v/48v sequence of events (1c31157g01) 125v sequence of events (1c31157g02) 48v on-card contact wetting soe (1c31157g03) Rtd (1c31161g02) Rtd (1c31164g02) Link controller rs232/rs485 (1c31166g01) Rs232 link controller (1c31169g01) Rs485 link controller (1c31169g02) 0-10v ai; 0-10v ao loop interface (1c31174g01) 0-5v ai; 0-10v ao loop interface (1c31174g02) 0-20ma loop interface (1c31174g03) 0-5v electric drive (1c31174g04) Voltage ao loop interface (1c31177g01) Ma local shield loop interface (1c31177g02) Ma remote shield loop interface (1c31177g03) Master - attachment unit electronics (1c31179g01) Master - attachment unit electronics (1c31179g02) Master - attachment unit pmod - 2n (2km) (1c31181g01) Master - attachment unit pmod - 4n (2km) (1c31181g02)
Dxa-6300 -480 960021-02 Dxa-480 dx-480 850021 Dxa-6300 Dxa-8200 Dxa-8300 Dxa-8400 dx-8400 960080-03 Dxe 450 Dxe-208c dxe208c Dxe-208c dxe208c Dxe-316w Dxe-316wb Dxe-4120w 960128-01 a4 Dxe-450b Dxe-455w 960100-01 Dxe-480 Dxm-208 960105-06 Dxm-208 960105-16 Dxm-208c Dxm-308 Dxm-316 Dxm-316c 870360-56 960098-47 Dxm-316w 960098-10 Dxm-316w pg90-020 Dxm-316wb Dxm-340c Dxm-340c 960099-03 Dxm-340c 960099-03 a5 Dxm-340cb Dxm-340w Dxm-4120cb Dxm-4120w Dxm-455c Dxm-490c Dxm-490w Dxm6120 dxm-6120 Dxm-6200 Dxm-71208 Dxm-8200 Dxm-8400 Dxm-8400b 861120-00 Eb-202 Eb-202-00-00 Eb-203-00-000 Ecs-001.5 Ecs-050 Ecs-060 Ecs-15 810503-15 Ecsc-015 Ei-203-00-000 Ei-205-00-000 Eio-005 En-204 en204 En-204-00-000 En-204-00-000 960500-06 En-208 En-208-00-000 en20800000 En-214 Ep202-p00-en00 Ep202-p00-en00 Fm-2 Fm-3dn Fx-208 Fx-208 960135-01 Fx-208 fx208 Fx-316 Fx-316 fx316 401159-01 Fx-340 Fx-340 fx340 Fx-4120 Fx-4120 fx4120 Fx-455 Fx-455 960134-01
KJ2004X1-BA1 Remote Interface Unit
Mini circuit breaker is suitable for wires of AC 50Hz, rated voltage of 400V,rated current of 32A(63A)D, with some protection functions such as leakage because of getting an electric shock, overload, short circuit, etc., and it can add over-voltage protection function according to users’ requirements. It mainly used in building lighting and protection of power distribution system. This product accords with IEC61009 and GB16917.1 standard.
Mini circuit breaker, RCCB, ELCB, RCBO, RCD Mini current circuit breakers are used for protection against indirect touching of parts under voltage, for prevention of lasting voltage on earthed parts which should appear because of a defect in the electrical installation and for protection against direct contacts of parts under voltage in case of in
Vacuum circuit breaker serves in the power system of 10kv and three-phase ac 50hz to function as switching different kinds of loads needing frequent operation, and can protect and control electric equipment in the industrial & mineral enterprise, power plant and substation as well. It can coordinate with the kyn28a-12(gzs1) middle-arranged manual-driven switchgear or xgn- stantionary switchger as well. Main technical parameter: Rated voltage 12kv Rated current 630~3150a Rated short-circuit breaking current 20~40ka Rated peak withstand current 50~100ka Rated short-time withstand current 20~40ka Rated duration short-time 4s Machanical endurance 20000 times Carton package
EZ9R36225 // Easy9 Residual Current Circuit Breaker - 2P - 25 A - 30 mA - AC type - 230 V EZ9F56232 // Miniature circuit breaker, Easy9, 2P, 32 A, C curve, 6000 A
Specifications Description: Very fast-acting, currentlimiting fuse. Dimensions: See page 12 for Class Tdimensions. Construction: Melamine tube with silverfuse element. Ratings: Volts 300Vac (or less) 160Vdc (15-600A) 170Vdc (601-1200A) Amps 1-1200A IR 200,000 RMS Sym. 20,000A dc @ 160Vdc 100,000A dc @ 170Vdc Agency Information: CE, Std. 248-15, Class T, UL Listed, Guide JDDZ, File E4273, CSA Certified, Class 1422-02, File 53787. Features and Benefits Series combination ratings with branch circuit breakers allows broad range of coverage, independent of breaker manufacturer. Current limitation for non-inductive circuits provides Class T current-limiting response to maximum ground fault and short-circuit conditions. 200,000A interrupting rating provides high ratings at all circuit locations. Small footprint allows more efficient use of available space. Typical Applications Large Apartment Complexes Multi-Family Meter Stacks VFD Line Protection JJN-1 JJN-2 JJN-3 JJN-6 JJN-10 JJN-15 JJN-20 JJN-25 JJN-30 JJN-35 JJN-40 JJN-45 JJN-50 JJN-60 JJN-70 JJN-80 JJN-90 JJN-100 JJN-110 JJN-125 JJN-150 JJN-175 JJN-200 JJN-225 JJN-250 JJN-300 JJN-350 JJN-400 JJN-450 JJN-500 JJN-600 JJN-700 JJN-800 JJN-1000 JJN-1200
Standard: IEC/EN61009-1 GB/T16917.1 Instantaneous trip type: B/C/D The number of poles: 1P+N Rated short circuit breaking capacity (Icn): 6kA Leakage protection trip type: Electronic /Electromagnetic Rated working current (In): 6-40A Rated working voltage (Ue): AC 230 Rated operating frequency: 50/60Hz Rated insulation voltage (Ui): 500V Rated residual operating current : 10/30/100/300mA Life : 4000 Times Type of residual current: A/AC
Standard: IEC/EN60898-1 GB/T10963.1 Instantaneous trip type: Electronic /Electromagnetic The number of poles: 1P+N/3P+N Rated limit short circuit breaking capacity (Inc): 6kA Rated working current (In): 16-63A (can be extended to 125A) Rated working voltage (Ue): AC 230/400V Rated operating frequency: 50/60Hz Rated impulse withstand voltage (Uimp): 4kV Rated residual operating current : 10/30/100/300mA Mechanical/electrical life: 4000/4000 Times Type of residual current : A/AC
Standard: IEC/EN61009-1 GB/T16917.1 Instantaneous trip type: B/C/D The number of poles: 1P+N Rated short circuit breaking capacity( Icn): 6kA Release Type of Leakage Protection: Electronic Rated working current In: 6-40A Rated working voltage (Ue): AC 230V Rated operating frequency: 50/60Hz Rated insulation voltage (Ui): 500V Rated residual operating current : 10/30/100/300mA Life :4000 Times Residual current type: A/AC
Standard: IEC/EN61009-1 GB/T16917.1 Instantaneous trip type: B/C/D The number of poles: 1P+N Rated short circuit breaking capacity (Icn): 6kA Leakage protection trip type: Electronic /Electromagnetic Rated working current (In): 6-40A Rated working voltage (Ue): AC 230/400V Rated operating frequency: 50/60Hz Rated insulation voltage (Ui): 500V Rated residual operating current : 10/30/100/300mA Life: 4000 Times Type of residual current : A/AC