Number:SLADE-GSS Specifications:Thickness 0.12-5mm Classification:Galvanized strip Introduce:Thickness: 0.12mm-5.0mm Width: Customized according to client's request Coil ID: 100mm/508mm Product description Specification of Hot Dip Galvanized Steel Strip: 1) Capacity: about 10,000 ton per month for steel strip/tape product 2) Thickness: from 0.12mm to 5.0mm, all available. 3) Width: Customized according to client's request. 4) Coil weight: from 100kg to 1500kg 5) Zinc coating weight: 30g/m2-600g/m2 6) Spangle : big spangle, normal spangle, small spangle, non-spangle
A threaded flange is a type of flange that uses a screw thread to connect the flange to a pipe. A male thread is cut onto a pipe end whilst a female thread is cut into the bore of the flange; the male threaded pipe is then screwed into the female threaded flange. Threaded flanges are available in a variety of sizes and pressure ratings, and are typically made from Various Materials. Technical Specifications 1. Materials: Carbon steel, stainless steel, alloy steel, 2. Size: �½ inch to 24 inches 3. Classes: 150, 300, 400, 600, 900, 1500, 2500 4. Thread type: NPT, BSP, BSPT, BSPP 5. Face type: Flat, Raised and Ring Joint 6. Dimensions: ANSI B16.5, ASME B16.47, Advantages of Threaded Flanges: A. Easy to install and maintain B. No welding required C. Suitable for a variety of applications D. Available in a variety of sizes and pressure ratings Applications: Threaded flanges are used in a variety of applications, including: a. Water and wastewater systems b. Oil and gas pipelines c. Chemical processing plants d. HVAC systems e. Fire protection systems
Products standard processing and traceability 1. Fermentation period varies by each specialty process 2. The drying period varies with each specialty process (7 - 45 days) 3. 100% Arabica green beans 4. Varieties: Mix (Tim Tim, Bourbon, Ateng Super, P88, Cattimor, Gayo 1, Gayo 2) 5. Altitude: 1500 - 1800 masl (meters above sea level) 6. Moist: 12%, Defect: 4% 7. Passage Trough A Screen, % (w/w) ê?? 5mm: 0 - 5 max 8. Grade 1 double pick / triple pick international grading standard ONLY. 9. Harvesting periods: From February to May & From September to December 10. Specialty Coffee Association standard 11. Quality Reference : SNI.01-2907-2008 / 12. ICO (International Coffee Organization) Terms a) Will process the production until export ready after signing the contract. b) 2 - 3 months depending on quantity and types of specialty beans c) FOB Belawan Port, Medan, Indonesia d) CIF applicable with upfront e) 100% Cash Against Documents (CAD) f) 100% LC by only top reputable banks g) Packaging: Double bags of Jute Bag and Grainpro Bag inside (1 bag = 60 kilogram) Order quantity 1 FCL of 20'â??= >200 bags to max 345 bags LCL with Minimum order quantity per beans (MOQ) = 10 bags = 600 kilograms (can mix) International grading standard: 1. G1 grade beans (Double Pick-DP) Moist 14% and Defect 8%. 2. Premium Grade beans (Triple Pick- TP) Moist 12% and Defect 4%. Only by 60 kg bags MOQ 1 container 20 footer (can mix) Our Gayo Arabica specialty coffee green bean types: -Wet Hulled G1 (commercial grade) -Fully Washed -Natural -Natural on Aerobic -Honey -Winey Soft (Wine Process)
A forged square plug is a type of threaded fitting that is used to block the end of a pipe or tube It is made of a solid piece of metal that is forged into a square shape with a threaded bore The threaded bore allows the plug to be screwed into the end of the pipe or tube Technical Specifications The technical specifications of a forged square plug vary depending on the material used the size and the pressure rating However some common specifications include Specifications 1 Material Steel stainless steel or other metal 2 Standard ASMEANSI B1611 3 Size 12 inch to 4 inches in diameter 4 Pressure rating 100 to 10000 psi 5 Thread NPT SAE or BSPP 6 Finish Black galvanized or other coating Applications Forged square plugs are used in a variety of applications including Oil and gas pipelines Chemical processing plants Water treatment facilities Power plants HVAC systems Marine applications Advantages The advantages of using a forged square plug include Strong and durable construction Threaded bore for easy installation Wide range of materials and sizes available Can be used in highpressure applications Overall a forged square plug is a versatile and reliable type of threaded fitting that can be used in a variety of applications It is a good choice for applications where strength durability and a wide range of materials and sizes are required
S.S steel & titanium.
1.Description: 5x31.5mm/5x28.5mm, clear glass, flat base; conical base with polyspring. 2.High quality with low price. 3.Free samples and prompt delivery. 4.Small order and oem are acceptable. They are packed in pp-trays with plastic film and cover plate, outside packing is carton. Special packing requirement is acceptable.
Thickness:3+0.38+3mm.,4+0.38+4mm,5+0.38+5mm,6+0.38+6mm,etc. PVB color:clear,gray, bronze, blue, green,wilky white, black,red etc. Glass color:clear,euro bronze,euro gray, dark gray, f-green,dark green,dark blue, ford blue,pink,etc. Size:3300*2134mm,2440*1830mm, max:7500*2440mm,also according to customers¡¯ requirement. Laminated glass is one kind of glass that two sheet glass are bound with PVB interlayer.formed under high temperture. The two sheet glass could be float glass, tempered glass, silk printed glass, curved glass,wired glass,low-e glass ,etc. Feature: 1) Sound control: 2) Save energy: 3) Safety:if the glass cracks,spliters will adhere to the interlayer and not scatter. 4) Sound control:PVB interlayer is an effective absorber of sound. Application: curtain wall,shower door,swimng pool fencing ,partitions,shop display windows,etc. Quality standard:CE,ISO9001 Delivery time: about 15days after receieve the prepayment Packing :wooden case.
Orthopedic implants like bone screw, bone plate, cortical screw, cancellous screw, cannuated screw, small DCP plate, interlocking nail, kwire, knail.
Mini Fragment Plates (for 2.0mm Screws) Straight Mini Plate (Finger Plates) Cat. No. : Holes : Length ST131.03 : 3 : 17mm ST131.04 : 4 : 23mm ST131.05 : 5 : 29mm ST131.06 : 6 : 35mm ST131.07 : 7 : 41mm ST131.08 : 8 : 47mm Thickness : 4 holes to 6 holes - 1mm Thickness : 7 holes & 8 holes - 1.5mm Width : 5 mm
ST100.00 Basic Instrument Set for 3.5mm & 4.5mm Screws Contents ST003.02 : Drill Bits (s.s. Quik Coupling End) 2.5mm : 1 no ST992.04-07 : Drill Bits (s.s.) : 2.5 & 3.5 : 2 nos. each ST903.02 : Counter Sink For 6mm : 1 no ST303.00 : Tap Handle : 1 no ST203.04 : Tap : 3.5mm Cortex : 2 nos ST203.05 : Tap : 3.5mm Cancellous : 1 no ST203.06 : Tap : 4mm Cancellous :1 no
Contents Semi Tubular Plate 2 Plates each with 4, 5, 6 & 7 Holes 8 nos. D.C.P. (Narrow) 2 Plates each with 4, 5, 6, 7, 8, 9 & 10 Holes 14 nos. D.C.P. (Broad) 2 Plates each with 6, 7 & 8 Holes 6 nos. 1 Plate each with 9, 10, 11, 12, 14 & 16 Holes 6 nos.
Contents ST091.01 : Single Pin Clamps : 24 nos. ST091.02 :Double Pin Clamps : 6 nos. ST091.03 : Open Clamp : 4 nos. ST091.04 : Connecting Clamp : 8 nos. ST091.05 : Twin Clamp (Straight) : 4 nos. ST091.06 : Twin Clamps (Reverse) : 4 nos. ST002.51 : Schanz Screw : Dia. 4mm : 12 nos. ST002.52 : Schnaz Screw : Dia. 4.5mm : 24 nos. ST002.61 : Schnaz Screw : Dia. 5mm : 12 nos.
AustinMoore Prostheses Size Available in 37mm to 57mm
Indications: Fractures of the clavicle shaft Malunions of the clavicle shaft Non-unions of the clavicle shaft Plate Features: Anatomically pre-shaped, twisted design. Due to Lateral superior placement, there is less need to detach muscles than with anterior placement. Undercuts reduce impairment of blood supply. Good purchase also in osteoporotic bone and in multifragment fractures. Tapered plate tip facilitates percutaneous insertion and prevents soft tissue irritation
Indications: Extra-articular and simple intra-articular distal tibial fractures. Distal tibial fractures, percutaneous or reducible by limited arthrotomy. Distal tibial fracture extending into the diaphyseal area. Plate Features: These Plates can be anatomically contoured to match with the Distal Medial Tibia. These plates are designed for both right and left tibia and are available in a variety of lengths. The head hole allows only 3.5 mm Safty Lock screws, rest holes allow both 3.5 mm Safety Lock and Cortical screws. Screws : For Combi holes - 3.5 Locking, 3.5 Cortical, 4.0 Cancellous. For Round Locking Holes - 3.5 Locking, 2.7 or 3.5 Cortical, 4.0 Cancellous.
As buttress for the femoral condyles with multiple fragment fractures.
Indications: Complex intra-articular and extra-articular olecranon fractures. Pseudoarthrosis of the proximal ulna. Simple olecranon fractures. Repair of the olecranon after osteotomies in distal humerus surgery. Plate Features: Angular stable fixation of fragments regardless of bone quality. Minimised risk of primary and secondary loss of reduction, even under high dynamic loading. Reduced impairment of periosteal blood supply due to the limited plate contact.
Plate Features: Proximal Tibia Safety Lock Plate 3.5mm is used for Non-unions, Malunions, and fractures of Proximal Tibia, including Simple, Comminuted, Lateral wedge, Depression, Medial wedge, Bicondylar, Combination of Lateral wedge and depression and fractures associated with shaft. These plates can be anatomically contoured to match Proximal Lateral Tibia. These plates are designed for both right or left Tibia and are available in a variety of lengths. The head and three Proximal holes allow only 3.5 mm Safety Lock screws, rest holes allow both 3.5 mm Safety Lock and Cortical screws.
Clavicle Hook Safety Lock Plate 3.5 is indicated for Extra-articular and Intra-articular fractures of Lateral Clavicle . Anatomically precontoured: The plate facilitates optimal implant placement and surgery to provide an improved outcome. Rounded shaft profile minimizes the risk of soft tissue irritation between the plate and surrounding soft tissue. Undercuts in shaft reduce impairment of blood supply. The plates are designed for both Right and Left Clavicle bones and are available in a varying lengths and Hook depths. All holes of plate accept 3.5 mm cortex, 3.5mm safety lock and 4.0 mm cancellous screws.
Locking Proximal Humerus Plate is used for complex and unstable fractures. Indications Proximal Humerus Multifragmentary (dislocated) fractures requiring open reduction Unstable subcapital fractures Subcapital pseudarthrosis Osteotomies Suture holes The fixation of additional wireloops or sutures attached to the tubercles (in 3- or 4-fragment fractures) neutralises the muscle tension and helps to maintain reduction. The head of plate allows only 3.5 mm Safety Lock Screws and shaft of the plate allows both 3.5 mm Safety Lock and Cortical screws.