Kind:Through-link needle,pen needle,piping needle Specification: 21G,22G,23G Character: Through-link needle and pen needle 1)the uniquely sharpened faction simplifies penetration of tissue. In comparison with other common needles, painful trauma is considerably reduced. 2)the special design of robber protection jacket reduces the contamination risk in that the distal end of the needle is immediately covered and protected from following removal of the blood. 3)The specially sharpened point results in minimal tissue damage and thromboplastin seepage. 4)The needle coating ensures smooth and gentle penetration when the needle is pierced into the patient vein. Piping needle Compare to the two type of needle before, it has more benefits , for example, Flexible wings improve needle pierce during blood collection and infusion procedures. Translucent shield improves users control of the blood collection and infusion procedures. Packing:50pcs/bag,1200pcs/ctn Weight:G.W.3.7kg/ctn,N.W.2.7kg Dimension:470mm*380mm*216mm
Humanistic design is applied to make this product convenient and sanitary. Its easy to collect, transport and test the stool specimen. Steriled, single packaged Packing:single packed1000pcs/ctn Weight:G.W.10kg/ctn, N.W.8kg/ctn Dimension:595mm*490mm*400mm
(1) Combining with domestic actual production demand, this machine is equipped with completely automatic machinery equipment integrating automatic tube filling, coagulant dosing and atomizing, drying, capping, vacuum capping, tube taking and tray packing; (2) This machine comprehensively adopts programmable control and pneumatic actuator. According to the product feature of vacuum blood collection tube, control all actuation actions of machinery in organic combination form via program and software; (3) This machine is equipped with automatic heat shrink packaging machine, so as to achieve packing automation and fully automatic modular production; (4) This machine adopts South Koreas Sejong bivalve and multi-function software control system to achieve dosing and atomizing; it also adopts two sets of 100-head plug-in hot air dryer, which can grasp the cap conveying device for 100 assembled caps, one full-automatic vacuum compensated-type vacuum capping machine and the tube taking and foam tray mechanism which can grasp 100 finished tubes simultaneously; after removing the tube, insert it into the foam packing tray mechanism, control such mechanism actions via programmable program and execute via pneumatic mechanism, in which way all procedures will be completed fully automatically, including BCA coagulant dosing, drying, capping, vacuum capping, tube taking and tray packing. This machine features high automation degree, high production efficiency, stable performance, low failure rate, easy operation, low maintenance fee, etc. (5) It is able to install oblique foam tray online according to customers demand.
Minimum Order Quantity: 100000 Unit Number of Layers: 3 Disposability: Disposable Usage/Application: Anti Pollution / To avoid Infection Filter: 99% Material: Non Woven Mask Securing Method: Ear loop Color: Blue Shelf Life: 2 Years Features: 1. Number of Layers: 3 Layer 2. Usage: Surgical 3 Ply Mask Without Nose Pin 3. Top layer blue 25 gsm 4. Middle layer white 20gsm 5. Bottom Layer white 25 gsm CE ISO certified & FDA Recommended Additional Information: 1. Delivery Time: Ready Stock 2. Packaging Details: 50pcs/bag, 2000pcs/carton 3. Production Capacity: 5000000
Vacuum tube 1, pro-coagulation tubes Plastic & glass tube are available Specification: 13x75mm, 13x100mm.16x100mm, , red cap 3ml, 5ml, 7ml, 8ml, 9ml 2, sst tube(gel seperate tube) Plastic & glass tube are available Specification: 13x75mm, 13x100mm, yellow cap 4ml, 6ml 3, glucose tube Plastic & glass tube are available Specification: 13x75mm, grey cap 2ml, 3ml, 4ml 4, esr tube Plastic & glass tube are available Specification: 13x75mm, 8*120mm(glass), black cap 1.6ml, 2.4ml 5, citrate tubes Sodium citrate 0.109mol/1(3.2%), 0.129mol/1(3.8%) Plastic & glass tube are available Specification: 13x75mm, 10.25x64mm, blue cap 1.8ml, 2.7ml, 4.5ml 6, heparin tube Heparin sodium or heparin lithium Plastic & glass tube are available Specification: 13x75mm, green ca 2ml, 3ml, 5ml 7, edta tubes Edta k2 or edta k3 available Plastic & glass tube are available Specification: 13x75mm, lavender cap 2ml, 3ml, 5ml 8, no-anticoagulation tube or plain tube Plastic & glass tube are available Specification: 13x75mm, 13x100mm.16x100mm, , red cap 3ml, 5ml, 7ml, 8ml, 9ml 50pcs/rack 1000pcs/ctn 61*43*27cm
SERUM TUBES In order to obtain serum samples from plastic tubes, the tube must have coagulation activator added. As the plastic suface alone is insufficient to trigger the coagulation within an acceptable time, LYBCON VACUTAINER serum tubes have silica particles added for this purpose. CLOTTING TIMES The recommended minimum time for the coagulation of samples from patients who have not been treated with anticoagulants is 30- 45 minutes for serum (red).
LYBCON Vacutainer GEL-SST Advance tubes During the centrifugation of the LYBCON Vacutainer GEL-SST Advance tubes, an inert LYBCON Vacutainer gel separates the serum and the blood clot preventing the contamination of the serum from the separated cellular components. For example, the serum for certain analytes such as potassium, phosphorus and glucose must be separated from the cells within a few hours - otherwise the results will be significantly distorted. Using LYBCON GEL-SST Advance tubes routine analyses in clinical chemistry such as potassium and glucose are still stable after a week of storage at 2-8 C. Clinical evaluations of special chemistry demonstrate a high degree of analyte stability with the acrylic gel in the LYBCON GEL-SST Advance, with detection of >90% of the therapeutic drugs and other special analytes(proteins/peptides, steroids and vitamins) tested. As a result of the type of gel used in the GEL-SST Advance tubes, LYBCON Vacutainer short centrifugation times of 5 minutes at 3000g can be achieved. The stability of the gel barrier is a distinct advantage during transport and storage. The main advantages of gel tubes versus non-gel tubes are: Stable barrier between serum and clotted blood, therefore better analyse stability. Better sample quality. Optimisation of the work flow: Short centrifugation time, sample processing and archiving in the primary tube. No possibility of misidentification due to the use of secondary tubes. CLOTTING TIMES The minimum recommended coagulation time for GEL-SST Advance tubes for patients who have not LYBCON Vacutainer received anticoagulation treatment is 30 minutes. CENTRIFUGING CONDITIONS 1600-2000g for 10 minutes MIXING RECOMMENDATION Serum Separation Tubes should be gently inverted 180 and back 6-8 times. EFFECTS OF TEMPERATURE LYBCON Vacutainer GEL-SST Advance should be stored at 4-25C and protected from direct sunlight during storage. Cooling of the tube by or during centrifuging can affect the movement capability of the gel. The optimum separation of serum and coagulated blood is achieved at a temperature of 20-25C. Serum Separation Tubes should be gently inverted 180 and back 6-8 times. CLOT ACTIVATOR LYBCON Vacutainer GEL-SST Advance tubes contain silica particles. SPECIFICATION Specimen: Serum Additive: Gel & Clot Activator Cap color: Dark yellow Tube Size: 13x75mm Draw Volume: 3.5mL Max. draw volume Tolerance: ±10%
SODIUM CITRATE Trisodium citrate is used as an anticoagulant for coagulation investigations. It works as an anticoagulant as it forms complexes with metal ions such as calcium inhibiting the coagulation cascade. Anticoagulation with trisodium citrate is reversible. LYBCON Vacutainer Citrate tubes contain buffered citrate in accordance with recommendations: 0.105 M or 0.109 M of buffered trisodium citrate solution, equivalent to 3.2% trisodium citrate The blood to additive ratio is 9:1. The citrate solution in the acts as LYBCON Vacutainer a buffer. Therefore, no additional buffer substances are added as these can adversely affect laboratory analysis. LYBCON Vacutainer Citrate tubes are also suitable for carrying out special test procedures such as the platelet function test PFA-100. Special tubes and the associated additional costs are therefore unnecessary. FILL LINE MARKING The significance of the correct ratio of blood to additive for coagulation samples is well documented. The correct fill amount is critical for correct coagulation analysis. All LYBCON Vacutainer coagulation tubes have a mark indicating the minimum fill level. CENTRIFUGING CONDITIONS For coagulation analysis different plasma specifications can be obtained from the citrated blood. Platelet rich plasma:150-200g for 5 minutes at 18-25 C Platelet poor plasma:2000-2500g for 10-15 minutes at 18-25 C Platelet free plasma: >3000g for 15-30 minutes at 18-25 C MIXING RECOMMENDATION Citrate tubes should be gently inverted 180 and back 3-4 times. SPECIFICATION Specimen: Plasma or Whole Additive: Sodium citrate 3.2% or 3.8% (9NC) Cap color: Blue Tube Size: 13x75mm Draw Volume: 1.8mL, 2.7mL Max. draw volume Tolerance: ±10%
The tubes are designed for blood The tubes are designed for blood LYBCON Vacutainer sedimentation without the use of sedimentation pipettes. The blood is taken directly into the tubes and LYBCON Vacutainer turned end-over-end 8-10 times. Immediately before the tubes are placed in the stand for measurement, LYBCON Vacutainer the tubes must be mixed again. After one or two hours the results are read. The stand holds a LYBCON Vacutainer maximum of 10 tubes and has a height Lybcon adjustable zero mark. The measurement results achieved correspond to the Westergren method. MIXING RECOMMENDATION ESR (Erythrocyte Sedimentation Rate) tubes should be gently inverted 180 and back 8-10 times. SPECIFICATION Specimen: Whole Additive: Sodium citrate 3.8% (4NC) Cap color: Black Tube Size: 13x75mm Draw Volume: 1.6mL, 1.8mL Max. draw volume Tolerance: ±10% sedimentation without the use of sedimentation pipettes. The blood is taken directly into the tubes and LYBCON Vacutainer turned end-over-end 8-10 times. Immediately before the tubes are placed in the stand for measurement, LYBCON Vacutainer the tubes must be mixed again. After one or two hours the results are read. The stand holds a LYBCON Vacutainer maximum of 10 tubes and has a height LYBCON Vacutainer adjustable zero mark. The measurement results achieved correspond to the Westergren method. MIXING RECOMMENDATION ESR (Erythrocyte Sedimentation Rate) tubes should be gently inverted 180 and back 8-10 times. SPECIFICATION Specimen: Whole Additive: Sodium citrate 3.8% (4NC) Cap color: Black Tube Size: 13x75mm Draw Volume: 1.6mL, 1.8mL Max. draw volume Tolerance: ±10%
Safety-Lok Blood Collection Set 21 Gauge 3/4 Inch Needle Length Safety Needle 12 Inch Tubing Sterile UOM: 200/CS Product Number: 367281 Manufacturer: BD
Safety-Lok Blood Collection Set 23 Gauge 3/4 Inch Needle Length Safety Needle 12 Inch Tubing Sterile UOM: 200/CS Product Number: 367283 Manufacturer: BD
Water Soluble silicide agent: 250ml Blood Clot activator Powder: 1 kg
Blood Clot activator Powder: Used for vacuum and non vacuum blood clot activator collection tube.
Vacuum Blood Collection Tube introduced by us promises to live up the expectations of the buyers. It is manufactured completely in clean room environment by using the best of the quality materials and assembled on a 100% Automatic assembly Line. We believe in quality and the same has been inculcated in our products. We produce the tubes in two volumes 13 75 mm and 13 100 mm. Variants : K2 EDTA (2 ml - 6 ml) K3 EDTA (2 ml - 6 ml) Clot Activator (2 ml - 6 ml) Sodium Heparin (2 ml - 6 ml) Lithium Heparin (2 ml - 6 ml) Sodium Fluoride (2 ml - 6 ml) Sodium Citrate (2 ml - 6 ml) Gel with Clot Activator (3.5 ml - 5 ml) We follow the colour codes of ISO 6710:2016 for the manufacturing process of the tube.
3 ply face masks with earloop customizations available
Venous Blood Collection Tube Serum Tube Clot Activator Additive 13 X 100 mm 6 mL Red BD Hemogard Closure Plastic Tube UOM: 1000/CS Product Number: 367815 Manufacturer: BD
Endotracheal Tube Mallinckrodt TaperGuard Cuffed Size 7 UOM: 10/BX Product Number: 18770S Manufacturer: Medtronic
Suction Tube Handle McKesson Yankauer Style Non-Vented UOM: 50/CS Product Number: 16-66202 Manufacturer: McKesson
Venous Blood Collection Tube Serum Tube Clot Activator / Separator Gel Additive 16 X 100 mm 8 mL Gold BD Safety Cap Closure Plastic Tube UOM: 1000/CS Product Number: 4850 Manufacturer: ImproVac
Venous Blood Collection Tube Analyte Determination Lithium Heparin / Separator Gel Additive 13 X 100 mm 5 mL Green / Yellow Ring Pull Cap Polyethylene Terephthalate (PET) Tube UOM: 1200/CS Product Number: 456087P Manufacturer: Greiner