CHISON Q8 is a multi-purpose, all digital, portable Color Doppler ultrasound system, which supports up to 256 probe elements. It features superior image quality across wide range of diagnostic applications, such as Abdominal,OB&GYN, Cardiac,Vascular, Small parts, Pediatric, Neonatal and Musculoskeletal. With its cutting-edge technologies, Q8 is one of few pioneers in the world which incorporate sophisticated features like real-time 4D,TDI, TEE scanning into one compact box. A Work-flow oriented User Interface is built to allow user-friendly operation with minimum soft key entry.Ergonomical design of keyboard, double probe connectors, USB and DICOM connectivity makes your scanning FAST and EASY and allow you focus more on your patients. í= 4D upgradeable í= TDI quantities cardiac analysis í= 2 probe connectors í= THI on all probes í= Probe elements up to 256 í= Double Phasing Digital Beam Forming
Acrylic White Color OM Temple ( H-37 x W-27 x L-19CM) Acrylic temple with Om design Made from high-quality acrylic material for durability and clarity Features a beautifully crafted Om symbol, a sacred symbol in Hinduism and Buddhism Adds a spiritual and aesthetic touch to any space Provides a focal point for meditation and mindfulness practices Easy to clean and maintain Lightweight and portable, can be easily moved to different locations Available in various sizes and designs to suit personal preferences Can be customized with different colors or additional embellishments for a personalized touch Ideal as a gift for spiritual or yoga enthusiasts Enhances the positive energy and ambiance of the surroundings Can be placed on a table, shelf, or mounted on a wall for display Creates a serene and peaceful atmosphere in any environment Can be combined with other spiritual or decorative elements for a harmonious arrangement
One Step Fecal Occult Blood (FOB) Rapid Test Cassette (Feces) Cat. No.: RH0301T INTENDED USE The One-Step Fecal Occult Blood (FOB) Diagnostic Kit is a qualitative detection of human occult blood in feces forself-testing. PRINCIPLE The One-Step Fecal Occult Blood (FOB) Diagnostic Kit is an immunochromatographic sandwich method, which employ two specific monoclonal antibodies to selectively identify hemoglobin in test samples. The result is very specific, and easier to interpret than those of guaiac-based test. The sensitivity is very high with the ability to detect 200ng/ml hemoglobin in feces. In addition, the accuracy of the test is not affected by interfering substances, and dietary restriction is not necessary. STORAGE The kits should be stored at temperature 4-30�°C, the sealed pouch for the duration of the shelf life (24 months). Do the test in 1 hour after open the pouch. WARNING AND PRECAUTIONS 1. For in vitro diagnostic use only. 2. Do not use kit beyond the expiration date. 3. Patient specimens may contain infectious agents and should be handled as though capable of transmitting disease. Wear disposable gloves throughout the specimen collection and assay procedures. 4. The test device should not be reused. REAGENTS AND MATERIALS PROVIDED 1. One pouched cassette with desiccant. 2. One operating Instruction MATERIALS REQUIRED BUT NOT PROVIDED 1. Clock or Timer SPECIMEN COLLECTION AND PREPARATION 1. Collect stool sample by using the sample collection device provided. 2. Unscrew the top of the sample collection device, take out the sample collection stick, and collect the sample by dipping the stick into 3 different places of the stool sample. 3. Put the sample collection stick back in the sample collection device and screw together tightly. 4. If the sample cannot be tested on the day of collection, store the stool sample at 4C. Bring the specimen to room temperature before testing. ASSAY PROCEDURE 1. Remove the test device from foil pouch by tearing along the notch. 2. Specimen collection. Please see also SAMPLE COLLECTION AND PREPARATION 3. Shake the sample collection device several times. 4. Holding the sample collection device upright, carefully unscrew the tip of collection device. 5. Squeeze 2-3 drops of the sample solution on the test sample pad. 6. Read the test results in 5 minutes. INTERPRETATION OF RESULTS Negative: Only one colored band appears on the control region (C). No colored band in the test region (T). Positive: In addition to the control band (C), a distinct colored band also appears in the test region (T). Invalid: If no bands appear, or a test band appears without a control band, the test should be repeated using a new test device.
Ultrasound scanner, color doppler, ultrasound machine, ultrasonic diagnostic system, ultrasound probe.
Products - Human Chorionic Gonadotropin (HCG) Test Midstream (Colloidal Gold Immunochromatographic Assay) Product Description - Sensitivity: 25 mIU/ml Accuracy: > 99.5% ISO13485 & CE approved INTENDED USE Easy-Sweet hCG Test Midstream is an in vitro diagnostic (IVD) qualitative test for rapid detection of hCG in urine. This test is designed for self-testing use only. PRINCIPLE Easy-Sweet. hCG Midstream is two-side sandwich immunoassay for the qualitative determination of human chorionic gonadotropin (hCG) in urine. The membrane was precoated with anti alpha hCG capture antibodies on the test band region and goat anti mouse on the control band region. During the test, the urine specimen is allowed to react with anti beta hCG monoclonal antibody-colloid gold conjugate, which was predried on the test Midstream. The mixture then moves forward on the membrane by the capillary action. For a positive specimen, the conjugate binds to the hCG forming an antibody-antigen complex. This complex is captured by anti alpha hCG antibody on the test region to produces a visual pink color band when hCG concentration in specimen is equal to or greater than 25 mIU/ml. Regardless of the presence of hCG, as the mixture continues to move across the membrane to the control band region, the complex is captured by immobilized goat anti mouse antibodies to form a distinct pink colored control band. The presence of the control band indicated: 1) a normal flow is obtained, 2) antibody pre-coated on control line and colloidal gold conjugate are functional. 1 pc/individual pouch , 500pcs/ctn or customized
One Step Troponin Test (Whole blood/Serum/Plasma FOR IN VITRO DIAGNOSTIC USE ONLY SPECIMEN COLLECTION 1. Testing should be performed immediately after the specimens have been collected. Do not leave the specimens at room temperature for prolonged periods. Specimens may be stored at 2-8C for up to 3 days. For long-term storage, specimens should be kept below -20C. 2. Bring specimens to room temperature prior to testing. Frozen specimens must be completely thawed and mixed well prior to testing. Specimens should not be frozen and thawed repeatedly. MATERIALS PROVIDED 1. Test cards individually foil pouched with a desiccant 2. Plastic dropper 3. Package insert MATERIALS REQUIRED BUT NOT PROVIDED 1. Timer/clock 2. Pipette 3. Controls ASSAY PROCEDURE 1. Read package insert carefully before testing. Allow the test devices, whole blood, serum or plasma to equilibrate to room temperature (15-30C) prior to testing. Do not open pouches until ready to perform the assay. 2. Remove the test device from the foil pouch and use it as soon as possible. 3. Place the test device on a clean and level surface. Hold the dropper provided vertically and transfer 3 drops of specimen (100�µl) to the specimen well (S) in the test device. 4. Wait for the red line(s) to appear. The result should be read between 10 to 15 minutes. INTERPRETATION OF RESULTS 1. Positive Two colored lines should be observed in the viewing window. The line in the test region (T) is the probe line; the line in the control region (C) is the control line, which is used to indicate proper performance of the device. The color intensity of the test line may be weaker or stronger than that of the control line. 2. Negative The control line appears in the test window, but the test line is not visible. 3. Invalid No line appears in the control region. Under no circumstances should a positive sample be identified until the control line forms in the viewing area. If the control line does not form, the test result is inconclusive and the assay should be repeated.
Syphilis Test INTRODUCTION Anti-Syphilis Test is a rapid direct binding test for the visual detection of anti-syphilis antibodies in serum as an aid in the diagnosis of syphilis infection. Test results are read visually without any instrument. It is based on the principle of double antigen sandwich immunoassay for determination of syphilis antibodies in serum. Purified recombinant syphilis antigens are employed to identify anti-Syphilis antibodies specifically. This one step test is very sensitive and only takes about 10 to 20 minutes. Syphilis Test SPECIMEN COLLECTION For serum, collect blood into a container without anticoagulant. Allow the blood to clot and separate the serum from the clot. Use the serum for testing. If the specimen cannot be tested on the day of collection, store the serum specimen in a refrigerator or freezer. Bring the specimens to room temperature before testing. Do not freeze and thaw the specimen repeatedly. Syphilis Test PROCEDURE Strip 1.When you are ready to begin testing, open the sealed pouch by tearing along the notch. Remove the test from the pouch. 2. Immerse the strip into the container with the arrow end pointing towards the container. Do not immerse past the MAX (maximum) line. Take the strip out after 8-10 seconds and lay the strip flat on a clean, dry, onabsorbent surface (e.g., mouth of the serum container). 3.Wait 10-15 minutes and read result. Do not read results after 20 minutes. Cassette 1. Open a pouch containing a cassette, lay the cassette. 2. Using the plastic pipettor provided, draw about 2-3 drops (100mL) the sample into the sample well of the cassette. 3. Read results within 10-15 minutes. Do not read results after 20 minutes. INTERPRETATION OF RESULTS Negative: Only one pink band appears on test region of the Cassette. This indicates that there is no detectable Anti-Syphilis in the serum. Positive: Two pink bands appear on test region of the Cassette. This indicates that the specimen contains detectable amount of Anti-Syphilis. Invalid: If without colored band appears on test region, this is an indication of a possible error in performing the test. The test should be repeated using a new device. Syphilis Test PRECAUTION: 1.�Must use fresh specimen and avoid repetitive freezing, the result will be invalid 2.�Use it before expiry date. 3.The package of kit should not be opened until it reaches the room temperature if it taken out from the refrigerator. 4�.Old Serum can not be used. If the serum is thick, it can be used only after being separated. Syphilis Test LIMITATIONS The test is for in-vitro diagnostic use only.
MP-U06 With12 inch high-resolution LED monitor, built in Li-ion battery, delicate appearance, exquisite image quality and excellent stability, our U6 hand-carried ultrasound diagnostic system serves clients whenever, at any place. The most important is that this model can be updated to 4D function.
TRANSDUCERS: - L38xi 10-5 MHz Linear Applications: lung, nerve, small parts, arterial, venous Scan depth: 9 cm - HFL38xi 13-6 MHz Linear Applications: breast, lung, musculoskeletal, nerve, ophthalmic, small parts, arterial, venous Scan depth: 6 cm - HFL50x 15-6 MHz Linear Applications: breast, musculoskeletal, nerve, small parts Scan depth: 6 cm - L25x 13-6 MHz Linear Applications: lung, musculoskeletal, nerve, superficial, arterial, venous, ophthalmic Scan depth: 6 cm - C11x 8-5 MHz Curved Applications: abdominal, neonatal, nerve, arterial, venous, cardiology (vet) Scan depth: 13.5 cm - rC60xi 5-2 MHz Curved Applications: abdominal, musculoskeletal, nerve, ob, gyn Scan depth: 30 cm - ICTx 8-5 MHz Curved Applications: ob, gyn Scan depth: 13 cm - rP19x 5-1 MHz Phased Applications: abdominal, cardiology, lung, ob, orbital, TCD Scan depth: 35 cm - P10x 8-4 MHz Phased Applications: ped. abdominal, ped. cardiology, neonatal head Scan depth: 14 cm - HSL25x 13-6 MHz Linear Applications: lung, musculoskeletal, nerve, superficial, arterial, venous, ophthalmic Scan depth: 6 cm - TEExi 8-3 MHz Multi Applications: adult cardiology, multiplane transesophageal 180 rotation of the imaging plane, providing a 360 field of view Scan depth: 18 cm - L52x (Vet) 10-5 MHz Linear Applications: musculoskeletal, ob, arterial Scan depth: 15 cm - C35x 8-3 MHz Curved Applications: abdominal, musculoskeletal, nerve, ob, spine Scan depth: 15 cm - C8x 8-5 MHz Curved Applications: prostate Scan depth: 11.5 cm - P11x 10-5 MHz Phased Applications: venous, vascular Scan depth: 12 cm
Ultrasound scanner, colposcope, infrared breast diagnose instrument.
Diagnostic Ultrasound.
Product description General --scanning mode: convex / linear / micro-convex --imaging mode: b, b+b, 4b, b+m, m --gray scale: 256 p --fluorescent key board for working in dark room --transducer connector: 2 (standard) --beam-forming: dbf digital beamformer Rdf real time dynamic filtering Dfs dynamic frequency scanning Rda real time dynamic aperture Dfr dynamic receiving focusing --scanning depth: 40-240 (depending on transducer) --cine-loop: 819 frames (max) --image pemanent storage: 32 frames (min) --image conversion: up/down; left/right; black / white --probe selectable: convex, linear, micro-convex, transvaginal, rectum Image processing --scanning angle adjustment, probe automatic identify, digital encoder knobs, gamma corrections, stat, histogram 16 grades scanning depth adjustment, 8 segment tgc adjustment, 128 arrays transducer Measurement& calculation Measurement: distance, circumference, area, volume, ef rate, heart rate Obstetric measurement: bpd, gs, crl, fl, ad, hc, ac, edd, ga, fw etc Body marks: no less than 40 marks Application/software package: abdominal, Ob/gyn, urology, pediatrics cardiology, small parts. Display: 10 inch b/w svga monitor Date, time, name, sex, age, doctor, hospital. Annotation; probe name, probe frequency Measurement values, body marks etc. Standard configuration: R60/3.5mhz convex(2.5 / 3.5 / 5.0mhz) 10 inch b/w svga monitor, usb2.0 port Optional: R13/6.5mhz transvaginal concex(5.0 / 6.5 / 7.5mhz) R20/5.0mhz micro-convex(2.5 / 3.5 / 5.0mhz) 7.5mhz linear(6.5 / 7.5 / 8.0mhz) 6.5mhz rectum linear(5.0 / 6.5 / 7.5mhz) Video printer, trolley, puncture frame Size & weight: N. W.: 11.5kg (inc. One probe) g. W.: 13.5kg Dimensions: 355mm(w)x315mm(l)x255mm(h) Meas: 425mm(w)x395mm(l)x410mm(h)
Product description General --128 arrays, 32 transmitting and receiving channels --scanning mode: convex/linear/micro-convex --imaging mode: b, b+b, 4b, b+m, m --transducer connector: 2 (standard) --scanning depth: 40-250(depending on transducer) --cine-loop: 2000 frames, several frames(b, 2b, 4b, 9b) can played simultaneously, also support b/m, m mode --image conversion: up/down, left/right, black/white --8 segment tgc adjustment, gamma correction, stat, histogram, --probe selectable: convex, linear, micro-convex, transvaginal, rectum Display: --10 inch b/w svga monitor --display: date, time, name, sex, age, doctor, hospital, annotation, probe name, probe fequency, measurement values, body marks etc. Standard configuration: R60/3.5mhz convex(2.5/3.5/6.0mhz) 10 inch b/w svga monitor, usb2.0 port Optional: -- r13/6.5mhz transvaginal concex(5.0/6.5/8.0mhz) -- r20/5.0mhz micro-convex(2.5/3.5/6.0mhz) -- 7.5mhz linear(6.5/7.5/12.0mhz) -- 6.5mhz rectum linear(5.0/6.5/8.0mhz) -- ink jet printer, laser printer, video printer, video recorder -- trolley, puncture frame Size & weight: N. W.: 11.5kg (inc. One probe) g. W.: 13.5kg Dimensions: 355mm(w)x315mm(l)x255mm(h) Meas: 425mm(w)x395mm(l)x410mm(h)
Ultrasound & color dopplers.
Color doppler ultrasound scanner.
Our Rapid Typhoid Testing Kit is a cutting-edge solution for swift and accurate diagnosis of typhoid fever. This advanced kit is designed for quick detection of the Salmonella Typhi bacteria, streamlining the diagnostic process for healthcare professionals. With a user-friendly approach, it requires a small blood sample and delivers results within minutes, enabling rapid treatment decisions. The kit exhibits exceptional sensitivity and specificity, ensuring reliable diagnoses even in low-infection scenarios. Its compact, portable design makes it ideal for remote and resource-limited areas. Trust our Rapid Typhoid Testing Kit for fast, dependable, and life-saving typhoid fever diagnosis, enhancing patient care and containment of this infectious disease.
Full-featured digital imaging on your desktop Organize and integrate your workflow The SONOACE R3 is a full-featured portable digital color ultrasound system with virtually all the imaging capabilities of a cartbased system. Full Spectrum ImagingTM Quick ScanTM Harmonic imaging Freehand 3D Cardiac package Color, power and PW Doppler 15" LCD monitor Two probe ports.
Ultrasound scanner 7" b/w monitor Convex sector/linear scanning Full range of measurements and calculating functions for professional diagnosis Avariety of measurement, image processing, zoom display and depth scrolling Cdf&cda Multi-frequency probe technology featuring high density and broad frequency Two probe connectors with automatically probe switching Optional function of cine loop 585mm*405mm*309mm 12kg/14kg
Ultrasound scanner 10" b/w crt monitor Convex sector/linear scanning Full range of measuring functions including ob table, lmp, cardio function, multi-parameter fetus weight measurement, etc Cda&cdf Svga technology Digital scanning technology including double echo, tgc, dsc and more Digital image processing functions including stc, frame correlation, etc 540mm*420mm*420mm 12/13kg
BRIEF: *Dual power supply system: via adaptor or lithium rechargeable battery; *10.4-inch LCD display helps ease visual tiredness of the user with less harmful radiations *Compact and lightweight for easier carry and outdoor diagnosis *User Friendly operation interface * 2-Probe Connector * Max. Scanning Depth : 250mm * Cineloop: 256 * Image Storage : 16-image permanent storage, USB flash disk connectible * TGC: 6-segment TGC and Overall Gain * Zoom: Partial zoom and picture in picture display * Measurement: Distance, Area/perimeter, Volume (ellipse method), Angle, Heart rate, Time, EF slope, Fetal age , Weight and EDCB * SOFTWARE PACKAGES: Obstetrics: GS, CRL, BPD, HC, AC, FL, and LMP measure EDD etc; Gynecology: Uterus, Left/Right ovary, Endometrial thickness; Urology: Bladder, Left/ Right kidney, Prostate; Cardiology: Left/Right ventricle, Left atrium, Mitral valve, Pulmonary valve;Report generated automatically *VARIOUS PROBE AVAILABLE: 1) 80-element 2.5/3.5/5.0Mhz multi-frequency convex array probe (Standard Configuration) 2) 80-element 5.0/6.5/7.5Mhz multi-frequency transvaginal probe (Optional) 3) 80-element5.0/6.5/7.5Mhz multi-frequency linear array probe (Optional) 4) 80-element 2.5/3.5/5.0Mhz multi-frequency microconvex array probe(Optional) 5) 80-element 5.0/6.5/7.5Mhz multi-frequency microconvex array probe(Optional) Carton Size: 460mm*320mm*370mm N.W/G.W:4.5KG/7.0KG Volumetric Weight:9.0KG