ALSTOM Reverse Power Relay CCUM 21 High Res GBCCUM21PF107A DEFINITE TIME REVERSE POWER RELAY MODEL NUMBER CCUM21PF107A CCUM21 AUX. CURRENT OR VOLTAGE 24V DC C.T. SECONDARY 5 AMP C.T. CASE SIZE 1-1/2D VERT. 10T CONTACTS (S/R OR H/R) 1 N/O 1 N/C S/R FLAG YES FREQUENCY 50 HZ MOUNTING FLUSH MTA PHASE-CHAR ANGLE 30 DEGREES TIME DELAY P/U OR D/O 1 - 10 SECS. V.T/P.T SECONDARY 110V AC NAME PLATE-2 RZF9151-601 NAME PLATE-1 RFH9072-604 OUTLINE DRAWING MFJ013 WIRING DIAGRAM MPDZ609-01-2
ALSTOM Reverse Power Relay CCUM 21 High Res GBCCUM21PF111A DEFINITE TIME REVERSE POWER RELAY RELAY MODEL CCUM21PF111A CCUM21 AUX. CURRENT OR VOLTAGE 24V DC C.T. SECONDARY 1 AMP CT. CASE SIZE 1-1/2D VERT. 10T CONTACTS (S/R OR H/R) 2 N/O S/R FLAG YES FREQUENCY 50 HZ MOUNTING FLUSH MTA PHASE-CHAR ANGLE 30 DEGREES TIME DELAY P/U OR D/O 0.5 - 5 SECS. V.T/P.T SECONDARY 110V AC OUTLINE DRAWING MFJ013 NAME PLATE-1 RFH9072-604 NAME PLATE-2 RZF9151-601 WIRING DIAGRAM MPDZ609-01-1
GBCCUM21PF152A DEFINITE TIME REVERSE POWER RELAY Relay model no CCUM21PF152A Relay type - CCUM21(VTT) CASE SIZE 1.5D S/E CURRENT RATING 1 Amps V.T.SECONDARY VOLTAGE 110 V AC FREQUENCY 50 Hz TIMING RANGE ZONE-2 1 to 10 Secs TORQUE ANGLE(M.T.A) 30 DEG LEAD V OPERATING VOLTAGE 48 / 50 V DC CONTACTS 2 N/O S/R FLAG YES EXT.RESISTOR 400 OHMS NAME PLATE-VTT RZF9151 601 NAME PLATE RFH9072 604 OUTLINE DRAWING MFJ 013 WIRING DIAGRAM MPDZ 609.01-1
GBCCUM21PF153A DEFINITE TIME REVERSE POWER RELAY Technical Specifications Model No : CCUM21PF153A CCUM21 Case Size - 1-1/2D VERT. 10T Current Rating Cup unit - 1 Amp CT V.T Secondary Volts - 110 V ac Torque Angle (MTA)I Lead V- 30 Degree Frequency - 50 Hz Aux. Voltage - 48 / 50 V dc Contacts - 2 N/O S/R Flag - Yes Mounting - Flush Timing Range - 2.5 - 25 Secs Ext.Resistor - 400 Ohms 35 Watts Name Plate VTT RZF9151-601 Name Plate RFH9072-604 Outline Diagram MFJ 013 & RFJ0349 Wiring Diagram MPDZ609-01-1
GBCCUM21PF161A DEFINITE TIME REVERSE POWER RELAY Technical Specifications Model No : CCUM21PF161A CCUM21 AUX. CURRENT OR VOLTAGE - 110/125V DC C.T. SECONDARY - 5 AMP C.T. CASE SIZE - 1-1/2D VERT. 10T CONTACTS (S/R OR H/R) - 2 N/O S/R FLAG - YES FREQUENCY - 50 HZ MOUNTING - FLUSH MTA PHASE-CHAR ANGLE - 30 DEGREES TIME DELAY P/U OR D/O - 0.5 - 5 SECS. V.T/P.T SECONDARY - 110V AC External Resistor 1.3 K.OHMS Name Plate RFH9072-604 RZF9151-601 Outline Diagram MFJ013 & FJ0349 Wiring Diagram MPDZ609-01-1
Gbcdd21pf011sbch Self-powered Dir. Inverse Time O/c or E/ Technical Specifications Model No : Cdd21pf011sb(M) Cdd21(Self-powered) Application - E/f Burden - 3va C.t. Secondary - 1 Amp Ct. Case Size - 1-1/2d Vert. 10t Contacts (S/r or H/r) - 2 N/o S/r D.m.t - 3 Sec. E/f or U/v Setting - 10 - 40% E/f Flag - Yes Frequency - 50 Hz Mounting - Flush Mta Phase-char Angle - 45 Degrees O/c or O/v Setting - Not Applicable V.t/p.t Secondary - 63.5 to 190v a.c(E/f) External Resistor Name Plate Rfg9126-035 Outline Diagram Mfj013 Wiring Diagram Mpdz801.23
GBCDD21PF013SBCH DIRECTIONAL IDMT RELAY SELF POWERED Relay model no CDD21PF013SBCH Relay type CDD21 CASE SIZE 1.5D S/E APPLICATION E/F CURRENT RATING 5 AMPS CURRENT SETTING 1 TO 4 AMPS VOLTAGE 63.5 TO 190V AC FREQUENCY 50 HZ BURDEN 3 VA OPERATING TIME 3 SECS MTA I LEAD/LAG VOLT. 60 LAG DEG CONTACTS 3M S/R OUTPUT CONTACTS 2M S/R TAPS STD NAME PLATE RFG9126 035 OUTLINE DRAWING MFJ 013 WIRING DIAGRAM MPDZ 801.23
GBCDD21PF052SBCH DIRECTIONAL IDMT RELAY SELF POWERED Technical specification Relay model no CDD21PF052SBCH Relay type CDD 21 Case size 1.5 S/E Application E/F Current setting 1 to 4 amps C.T.Secondary 5 amps P.T.Sec.voltage 63.5 to 190V ac 50 Hz Burden / Operating time 3 VA / 1.3 secs M.T.A.Lead / Lag volt 45 Lag Contacts 3M S/R Output contacts 2M S/R Taps Std Name plate RFG9125 035 Outline drawing MFJ 013 Wiring diagram MPDZ 801.23
Gbcdd21pf053sbch Directional Idmt Relay Self Powered Technical Specification Cdd21pf053sbch Relay Type Cdd21 Case Size 1.5d S/e Application E/f C.t.secondary 5 Amps Current Setting 1 to 4 Amps Voltage 63.5 to 190v Ac Frequency 50 Hz Burden 3 Va Operating Time 1.3 Secs Mta I Lead/lag Volt. 14 Lag Deg Contacts 3m S/r Output Contacts 2m S/r Taps Std Name Plate Rfg9125 043 Outline Drawing Mfj 013 Wiring Diagram Mpdz801.23
ALSTOM GBCDD21PF055SJCH DIRECTIONAL IDMT RELAY SELF POWERED Technical specification RELAY MODEL NO CDD21PF055SJCH RELAY TYPE - CDD 21 CASE SIZE 1.5D S/E APPLICATION O/C CURRENT RATING 1 Amps CURRENT SETTING 0.5 - 2 Amps VOLTAGE 110V AC 50 Hz BURDEN 3 VA OPERATING TIME 1.3 Secs MTA I LEAD/LAG VOLT. 30 LEAD DEG CONTACTS 2M 2B H/R OUTPUT CONTACTS 2M 1B H/R TAPS STD NAME PLATE RFG 9125 011 OUTLINE DRAWING MFJ 013 WIRING DIAGRAM MPDZ 801.24
ALSTOM GBCDD21PF9054BCH SELF-POWERED DIR. INVERSE TIME O/C OR E/ Technical specification Relay model no CDD21PF9054BCH Relay type CDD 21 Case size 1-1/2D Vert.10T Application E/F Current setting 0.5 - 2.0 amps Aux.current or voltage 100 - 250V dc Burden 3 VA C.T.Secondary 5 amps Contacts (S/R OR H/R) 2 N/O S/R D.M.T 3 secs Taps Std Flag Yes Mounting Flush Frequency 50 Hz MTA Phase-char angle 60 Deg V.T/P.T Secondary 63.5V ac Name plate RFG9126-042 Outline drawing MFJ 013 Wiring diagram MPDZ 801-10-1
GBCDG11AF002SCCH SELF-POWERED INVERSE TIME O/C OR E/F REL Technical Specifications Model No : CDG11AF002SC(M) CDG11 APPLICATION - O/C BURDEN / D.M.T - 3VA / 3 SEC. C.T. SECONDARY - 1 AMP CT. CASE SIZE - 1D V 10T CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R E/F OR U/V SETTING - NOT APPLICABLE FLAG - YES MOUNTING - FLUSH O/C OR O/V SETTING - 0.5-2 Amps. Name Plate RFG9126 771 Outline Diagram MFJ012 Wiring Diagram MADZ802.64-1
ALSTOM GBCDG11AF004SACH SELF-POWERED INVERSE TIME O/C OR E/F REL Technical Specifications Model No CDG11AF004SACH CDG11 APPLICATION - E/F BURDEN - 3VA / 3 SECS. C.T. SECONDARY - 5 AMP C.T. CASE SIZE - 1D V 10T CONTACTS (S/R OR H/R) - 2 N/O S/R E/F OR U/V SETTING - 0.5 - 2 Amps. FLAG - YES MOUNTING - FLUSH O/C OR O/V SETTING - NOT APPLICABLE Name Plate RFG9126-795 Outline Diagram MFJ012 Wiring Diagram MADZ802.63-1
GBCDG11AF013SCCH SELF-POWERED INVERSE TIME O/C OR E/F REL Technical Specifications Model No : CDG11AF013SCCH CDG11 APPLICATION - E/F BURDEN / D.M.T - 3VA / 1.3 SECS. C.T. SECONDARY - 5 AMP C.T. CASE SIZE - 1D V 10T CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R E/F OR U/V SETTING - 1 - 4 Amps. FLAG - YES MOUNTING - FLUSH O/C OR O/V SETTING - NOT APPLICABLE Name Plate RFG9125 796 Outline Diagram MFJ012 Wiring Diagram MADZ802.64-1
ALSTOM GBCDG11AF014SACH SELF-POWERED INVERSE TIME O/C OR E/F REL Technical Specifications Model No : - CDG11AF014SA(M) CDG11 APPLICATION - E/F BURDEN /D.M.T - 3VA /1.3 SECS. C.T. SECONDARY - 5 AMP C.T. CASE SIZE - 1D V 10T CONTACTS (S/R OR H/R) - 2 N/O S/R E/F OR U/V SETTING - 0.5 - 2 Amps. FLAG - YES MOUNTING - FLUSH O/C OR O/V SETTING - NOT APPLICABLE Name Plate RFG9125-795 Outline Diagram MFJ012 Wiring Diagram MADZ802.63-1
ALSTOM GBCDG11AF014SCCH SELF-POWERED INVERSE TIME O/C OR E/F REL Technical Specifications Model No : CDG11AF014SC(M) CDG11 APPLICATION - E/F BURDEN / D.M.T - 3VA / 1.3 SECS. C.T. SECONDARY - 5 AMP C.T. CASE SIZE - 1D V 10T CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R E/F OR U/V SETTING - 0.5 - 2 Amps. FLAG - YES MOUNTING - FLUSH O/C OR O/V SETTING - NOT APPLICABLE Name Plate RFG9125 795 Outline Diagram MFJ012 Wiring Diagram MADZ802-64-1
Alstom Gbcdg21af001zmch Obsoleted Model Ref.gbcdg21af101zmch Obsoleted Model Ref.gbcdg21af101zmch
ALSTOM GBCDG21AF101ZMCH 1 POLE INV.TIME O/C OR E/F RELAY WITH IN Technical Specifications Model No : CDG21AF101ZM(M) CDG21/CAG17(MRK-III) APPLICATION - O/C BURDEN / D.M.T - 3VA / 3 SEC. C.T. SECONDARY - 5 AMP C.T. CASE SIZE - 1D V 10T CONTACTS (S/R OR H/R) - 2 N/O S/R FLAG - YES FREQUENCY - 50 HZ HIGH SET TYPE - CAG17 HIGHSET CONTACTS - 2M S/R HIGHSET O/C SETTING - 12.5-100 Amps. MOUNTING - FLUSH O/C SETTING - 2.5 - 10 Amps. Name Plate RFG9126 674 Outline Diagram MFJ 012 Wiring Diagram MADZ821.31
ALSTOM GBCDG21AF102ZMCH 1 POLE INV.TIME O/C OR E/F RELAY WITH IN Model No : CDG21AF102ZM(M) CDG21/CAG17(MRK-III) APPLICATION - O/C BURDEN / D.M.T - 3 VA / 3 SEC. C.T. SECONDARY - 1 AMP CT. CASE SIZE - 1D V 10T CONTACTS (S/R OR H/R) - 2 N/O S/R FLAG - YES FREQUENCY - 50 HZ HIGH SET TYPE - CAG17 HIGHSET CONTACTS - 2M S/R HIGHSET O/C SETTING - 2.5-20 Amps. MOUNTING - FLUSH O/C OR O/V SETTING - 0.5 - 2 Amps. Name Plate RFG9126 671 Outline Diagram MFJ 012 Wiring Diagram MADZ821.31
GBCDG21AF106ZMCH 1 POLE INV.TIME O/C OR E/F RELAY WITH IN Model No : CDG21AF106ZM(M) CDG21/CAG17(MRK-III) APPLICATION - E/F BURDEN / D.M.T - 3 VA / 3 Secs. C.T. SECONDARY - 1 AMP CT. CASE SIZE - 1D V 10T CONTACTS (S/R OR H/R) - 2 N/O S/R E/F OR U/V SETTING - 0.1-0.4 Amps. FLAG - YES FREQUENCY - 50 HZ HIGH SET TYPE - CAG17 HIGHSET CONTACTS - 2M S/R HIGHSET E/F SETTING - 1 - 8 Amps MOUNTING - FLUSH Name Plate RFG9126 692 Outline Diagram MFJ 012 Wiring Diagram MADZ821.31