Ip/ep converter Ip/ep transducer Electropneumatic transducer Input electrical current:4-20ma, 0-10v Output pressure:20-100kpa Et-500 is electropneumatic transducer equipment, it can decrease supply pressure to produce output pressre which is effectively proportional to input electric signal. Supply pressure range:125kpaí½1000kpa.With bulk augmenter supply big flow (20.4 m3/h). Features: Flow rate: 7.6m3/h when supply pressure is 175kpa 20.0m3/h when supply pressure is 700kpa Min/max. Supply pressure: Minimum-3psig(21kpa) above maximum output Maximum-100psig(700kpa) Sensitivity:
Features: 1. Pressure ranges: 0~10, ..., 0~3000 bar 2. Output signals: 4~20 ma, 0~5 v or 0~10 v 3. High precision: up to 0.05%fso (applicable for range >16barg) 4. Temperature coefficients of zero & span: 0.005%fso 5. Flush membrane available for pressure range > 16 barg 6. Integrated design for 100% pressure seal, no o-ring built in its body 7. Materials: 304 ss (housing); 17-4ph (wetted parts) Oem inner box and carton
Descriptions and gauge configurations Based on piezoresistive effect, bcm semiconductor strain gauges are made from p-type doped silicon wafer, and manufactured in two types: bar-type and backing-type. When gauges are made in the bar-type, they are naked gauges (sn-series), while made in the backing-type, the gauges are backed with phenolic-resin (sb-series). The semiconductor gauges are manufactured of three different dimensions ("1", "2" and "3") and the gauge leads can be finished in different lead-configuration. Illustrated on the top, are some sb-series backed-gauges of type 2 lead-configuration. Oem inner box and carton
Siamatc sitop power.
The platform measures the three orthogonal force components along the X, Y, and Z axes, and the moments about the three axes, producing a total of six outputs. The high sensitivity, low crosstalk, excellent repeatability and long term stability of this platform makes it ideal for research and clinical studies. The JP5050 is easy to use and is available in 5,000 Newton vertical capacity. Fx, Fy Capacity (N): 2.5 KN Fz Capacity (N): 5 KN Mx Capacity (Nm): 1 KNm My Capacity (Nm): 1.5 KNm Mz Capacity (Nm): 0.75 KNm Fx, Fy Sensitivity (µV/[V*N]): 0.30 Fz Sensitivity (µV/[V*N]): 0.12 Mx, My Sensitivity (µV/[V*Nm]): 0.25 Mz Sensitivity (µV/[V*Nm]): 0.37 Safe Temperature Range: 0í½50OC Compensated humidity Range: 20í½70%RH Safe Excitation Voltage: 12V DC Crosstalk: Less than 2% on all channels Sensitivity Change with Temperature:í_1%/ípC Fx, Fy, Fz hysteresis: í_ 1% Full Scale Output Fx, Fy, Fz non-linearity: í_ 1%Full Scale Output 400*600*117mm Net Weight: 35 Kg Packaged in carton
Applications An Electromyography (EMG) use EMG electrodes to pick up the electromyographic signal directly from the skin surface or within the subjects muscle using disposable fine-wire electrodes. Both are typically expressed in SI units micro Volt (mv). The Bioforcen-TB0810 model Biomechanics EMG can be used for biomechanics, engineering, medical research, orthopedics, rehabilitation evaluation, prosthetics, and general industrial uses. Specific uses include gait analysis, testing or stability analysis, neurological analysis, prosthetics fitting, athletic performance, shoe design, and force, power, and work studies. Description The EMG signal from each muscle is individually pre-amplified, band-pass filtered prior to digitization, and then converted to a binary sample for each of the channels. These operations are all performed directly in the subject back-pack to maximize signal quality. The binary information is then sent from the subject back-pack unit, via a single lightweight cable or wireless, to the desktop unit where it checked for transmission accuracy and then converted to an analog signal suitable for almost any analog data recording system. The desktop unit provides full electrical safety isolation for the subject. AMPLIFICATION The Bioforcen-TB0810 model Biomechanics EMG provides excitation and amplification for multiple channels in one convenient package. These amplifiers process the transducer signals and provide outputs suitable for an A/D converter so that the data can be stored and processed by a computer. CALIBRATION Each platform is inspected and tested in JUNE calibration facility. The calibration procedure provides a detailed sensitivity matrix and a complete test of all system components, including the amplifier and the connecting cable if ordered together. SOFTWARE Automated data collection and reduction requires a computer and software. Bioforcen-Analysis, Bioforcen-software package, is specifically designed for biomechanics . EMG channels: 8 High pass filter (1st order): 10 Hz Low pass filter (2nd order): 1000Hz (Butterworth) EMG signal input mode: Raw Signal (¡À3 mV) EMG signal output mode: Signal (0~2 V) EMG channel sample rate 500~4,000 samples per second per channel. Number of event switches: 8 switches, Independent of EMG channels Indicator Lights: USB ok, Status ok Safe Temperature Range: 0í½50OC Compensated humidity Range: 20í½70%RH Safe Excitation Voltage: 9 V DC 180*80*20mm Net Weight: 260g Packaged in aluminum alloy chest
Compression, alloy steel load cell. Mainly used for vehicle scales, platform scale and industrial weighing system. Each loaded 4
Ferrite cores
MQ-70 Impedance analyzer detect all ultrasonic related parameters, application for underwater acoustic area and High Power ultrasonic area such as piezoceramic, piezoelectric crystal, ultrasonic transducer, converter, ultrasonic welding, ultrasonic sensor and so on.
Mq-70 impedance analyzer Mq-70 impedance analyzer detect all ultrasonic related parameters, application for underwater acoustic area and high power ultrasonic area such as piezoceramic, piezoelectric crystal, ultrasonic transducer, converter, ultrasonic welding, ultrasonic sensor and so on.
Power dicecup Unit size=10.5*10.7*7.6cmíín.W=114g, material:as/abs/pp, 2pcs aaa batteriesíúcolorú¦red.Blue, yellow, purpleú¿or consigned colorú¬ Unit size=10.5*10.7*7.6cm
Multilayer ferrite chip beads Excellent in physical properties, such as terminal strength, flexure strengh, soldering resistance and solerability.
Ni-Zn Soft Ferrite Cores Emi suppression generated from round cable used in digital equipment. Emi/rfi suppression, plus and matching transferor, choke, input filters
Introduction AC grid transducer converts an ac voltage or current input into a load independent output signal. With excellent temperature characteristic and good working stability. The unit conforms to IEC 60688. In a addition it meets the insulation requirements of IEC 60255-5, clauses 5, 6 and 8 as well as the high frequency disturbance test of IEC 60255-22 for Class III test voltage.
Introduction DC grid transducer isolate the DC input signal from the DC output signal, which is directly proportional to the input signal. These isolators can be used to prevent earth loops, which occur when a measuring source. It have an advantage over loop powered units, in that if for any reason the output lead should become disconnected, the input will not be saturated. With excellent temperature characteristic and good working stability. Main features ·Input: DC grid customized input ·Output: 0-5V,0-10V,4-20mA, 0-20mA optional (One channel) ·0.2/0.5 measurement accuracy ·100ms response time(T type 1s/500ms) ·Minimum thickness of size (T type) ·35mm Din rail mounting ·Rs485 port optional
Introduction AC power transducer converts ac current and voltage signals into a load independent dc signal proportional to active power (watt) and reactive power (var). Two output signals combination in one transducer. The current and voltage signals are passed into the circuit via precision instrument transformers to provide galvanic isolation between the input circuits and the transducer circuitry. Each pair of current and voltage signals is mathematically multiplied together to produce a product signal proportional to true power and independent of wave shape and phase angle. Main features ·Input AC grid active power(W): 5A(100V) / 1A(100V) / 5A(400V) / 1A(400V) ·Output: 0-5V,0-10V,4-20mA, 0-20mA optional ·Power supply: 85~265VAC/380VAC ·Three phase independent measurement ·RMS measurement and output ·0.5 measurement accuracy ·35mm Din rail mounting ·RS485 port optional ·Support customized parameters
Introduction AC programmable transducer measures a wide range of electrical parameters and generates analog or digital output signals suitable for interfacing with instrumentation and control systems. Total four channel output, with panel key or PC control programmable, user can free to set 4 different data from max 26 electrical parameter for sampling and analog signal output. Have three channel digital inputs and optional RS485-Modbus communication functionality. Can monitor the galvanically isolated DI signal and programmed the transducer with customized SCADA software. Any of the measured parameters can be read out via the optional RS485-Modbus connection. Features ·Input three phase AC grid parameter: 5A(100V) / 1A(100V) / 5A(400V) / 1A(400V) ·Output: 4-20mA/0-20mA; 0-5V/0-10V optional ·85~265VAC/380VAC wide voltage AUX for most country and application ·With 4 channel output (support max 22 types parameter for analog output) ·Front panel with 4 keypad for analog parameter configuration, do not need back ground software. ·With RS 485 port for remote electrical data ·500ms response time ·0.5 measurement accuracy ·35mm Din rail mounting ·Advanced electrical parameter ready optional ·SOE function optional
Introduction BJ-QP series electrical transducer measures a wide range of electrical parameters and generates analog or digital output signals suitable for interfacing with instrumentation and control systems. Have microcontroller technology as the core, using the latest algorithms, to achieve precise measurement. The output signal is based on the a root mean square(rms) measurement of the input signal and hence the transducer can be used with distorted waveforms. Snap on to DIN rail 35 x 7.5 mm complies with DIN-EN 50022 BS 5584 Main features ·Have microcontroller technology as the core, using the latest algorithms, to achieve precise measurement. ·Converts AC/DC electrical parameter input into a load independent output signal. ·Excellent temperature characteristic and good working stability. ·The output signal is based on the a root mean square(rms) measurement of the input signal and hence the transducer can be used with distorted waveforms. ·The unit conforms to IEC 60688. In an addition it meets the insulation requirements of IEC 60255-5, clauses 5, 6 and 8 as well as the high frequency disturbance test of IEC 60255-22 for Class III test voltage.
1.Type: convex array 2.Frequency: 3.5MHz 3.Compatible system: HIVision 6500, HiVision 5500,EUB-6000, EUB-6500 4.Application:Obstetrics,Abdominal 5.Condition: pre-owned one, original, in good working condition 6.With 60 days warranty
Toshiba PVT-661VT Endovaginal 10mm transducer 1.Type: Endovaginal 2.Frequency: 3-9MHz 3.Compatible system: Aplio 50 SSA-700A, Aplio SSA-750A, Xario SSA-660A 4.Condition: pre-owned and original, in good working condition 5.With 60 days warranty